transmissores magnetoestrictivos de nível · cônicas para a união de hastes e acessórios. nsvp...
TRANSCRIPT
Manual de operação
Level Plus®
Transmissores magnetoestrictivos de nível de líquidos com tecnologia Temposonics®
CHAMBERED
Índice de conteúdos
1. Dados de contato .............................................................................................................................................. 32. Termos e definições ........................................................................................................................................... 33. Introdução....................................................................................................................................................... 5
3.1 Objetivo e uso desse manual ..................................................................................................................................................................... 53.2 Símbolos e avisos usados ......................................................................................................................................................................... 5
4. Instruções de segurança ...................................................................................................................................... 54.1 Uso pretendido .......................................................................................................................................................................................... 54.2 Uso incorreto previsível ............................................................................................................................................................................. 64.3 Instalação, comissionamento e operação .................................................................................................................................................. 6
5. Visão geral do produto ........................................................................................................................................ 65.1 Componentes ............................................................................................................................................................................................ 65.2 Precisão .................................................................................................................................................................................................... 85.3 Garantia ..................................................................................................................................................................................................... 85.4 Identificação do número do modelo .......................................................................................................................................................... 95.5 Dados técnicos ........................................................................................................................................................................................ 11
6. Instalação e montagem ......................................................................................................................................126.1 Treinamento............................................................................................................................................................................................. 126.2 Ferramentas ............................................................................................................................................................................................ 126.3 Etapas de instalação ................................................................................................................................................................................ 126.4 Montagem ............................................................................................................................................................................................... 12
7. Conexões elétricas ...........................................................................................................................................137.1 Informações básicas ............................................................................................................................................................................... 137.2 Recomendações de segurança ................................................................................................................................................................ 137.3 Topologias industriais.............................................................................................................................................................................. 137.4 Recomendações de cabos ....................................................................................................................................................................... 147.5 Conduíte elétrico ..................................................................................................................................................................................... 147.6 Aterramento ............................................................................................................................................................................................ 157.7 Barreiras de segurança ............................................................................................................................................................................ 15
8. Comissionamento.............................................................................................................................................168.1 Treinamento............................................................................................................................................................................................. 168.2 Ferramentas ............................................................................................................................................................................................ 168.3 Software de configuração ........................................................................................................................................................................ 168.4 Etapas de comissionamento .................................................................................................................................................................... 16
9. Manutenção....................................................................................................................................................179.1 Treinamento............................................................................................................................................................................................. 179.2 Ferramentas ............................................................................................................................................................................................ 179.3 Inspeção .................................................................................................................................................................................................. 179.4 Manutenção preventiva ........................................................................................................................................................................... 17
10. Reparos .......................................................................................................................................................1710.1 Política de RMA (autorização de material devolvido) ............................................................................................................................. 1710.2 Treinamento........................................................................................................................................................................................... 1710.3 Ferramentas .......................................................................................................................................................................................... 1710.4 Detecção e resolução de falhas ............................................................................................................................................................. 1810.5 Software de configuração ...................................................................................................................................................................... 18
11. Peças de reposição .........................................................................................................................................1812. Interface ......................................................................................................................................................18
12.1 MODBUS ............................................................................................................................................................................................... 1812.2 DDA ....................................................................................................................................................................................................... 1812.3 HART® .................................................................................................................................................................................................. 18
13. Informações da agência ....................................................................................................................................1913.1 Visão geral das aprovações ................................................................................................................................................................... 1913.2 Certificados ........................................................................................................................................................................................... 2113.3 FM (NEC) ............................................................................................................................................................................................... 2113.4 FMC (CEC) ............................................................................................................................................................................................. 3113.5 ATEX e IECEx ......................................................................................................................................................................................... 45
Level Plus® CHAMBEREDManual de operação
I 3 I
1. Dados de contato
EUA
Dados geraisTel: +1-919-677-0100Fax: +1-919-677-2343E-mail: [email protected]://www.mtssensors.com
Endereço postal e de envioMTS Systems CorporationSensors Division3001 Sheldon DriveCary, North Carolina, 27513, USA
Atendimento ao clienteTel: +1-800-633-7609Fax: +1-800-498-4442E-mail: [email protected]
Suporte técnico e aplicaçõesSuporte técnico de emergência 24 horasTel: +1-800-633-7609E-mail: [email protected]
Alemanha
Dados geraisTel: +49-2351-9587-0Fax: +49-2351-56491E-mail: [email protected]://www.mtssensors.com
Endereço postal e de envioMTS Sensor Technologie, GmbH & Co. KGAuf dem Schüffel 958513 Lüdenscheid, Germany
Suporte técnico e aplicaçõesTel: +49-2351-9587-0E-mail: [email protected]://www.mtssensors.com
2. Termos e definições
6A Óleos pesados“Óleos crus pesados em geral”, correção de volume a 60 ºF (15.5 °C) por gravidade API.
6B Óleos leves“Produtos generalizados”, correção de volume a 60 ºF (15.5 °C) por gravidade API.
6C ModReferência de temperatura ajustável para definir o VCF.
6C Substâncias químicas“Fatores de correção por volume” (VCF) para aplicações individuais e especiais, correção do volume a 60 ºF (15.5 °C) por coeficientes de expansão térmica.
A
À prova de chamas Tipo de proteção baseada no gabinete onde são colocadas as partes que podem incendiar-se em uma atmosfera explosiva e que podem resistir à pressão desenvolvida durante uma explosão interna devido a uma mistura e que evita que a explosão afete o ambiente ao redor do gabinete.
À prova de explosãoTipo de proteção baseada no gabinete onde são colocadas as partes que podem incendiar-se em uma atmosfera explosiva e que podem resistir à pressão desenvolvida durante uma explosão interna devido a uma mistura e que evita a transmissão da explosão para o ambiente ao redor do gabinete.
C
Capacidade de operação O volume máximo de líquido que o usuário quer que contenha no recipiente é, geralmente, 80% do volume máximo que o recipiente pode hospedar antes de atingir o ponto de extravasamento.
Compensação de esferaUm valor de compensação, que representa o volume extra em uma esfera que apresenta partes geometricamente irregulares, é usado para calcular o volume junto com o raio da esfera.
D
DDA (Direct Digital Access (acesso direto digital))O protocolo digital proprietário desenvolvido pela MTS para usar em áreas intrinsecamente seguras.
Level Plus® CHAMBEREDManual de operação
I 4 I
Densidade Massa dividida pelo volume de um objeto a uma temperatura específica. O valor da densidade deve ser inserido em libras/pés cúbicos.
G
GOVI (Gross Observed Volume Interface (Volume bruto da interface observado))O volume total do tnaque ocupado pelo líquido de interface. O GOVI é obtido apenas quando se faz a medição de dois líquidos e se calcula pela subtração do volume do produto do volume total de líquido no tanque (GOVT – GOVP).
GOVP (Gross Observed Volume of the Product (Volume bruto do produto observado))O volume total do tnaque ocupado pelo líquido do produto. Ao medir apenas um único tipo de líquido, também constitui o volume total de líquido no tanque (GOVT). Ao medir dois líquidos, representa o volume total de líquido no tanque menos o volume do líquido da interface (GOVT – GOVI).
GOVT (Total Gross Observed Volume (Volume bruto total observado))O volume total de líquido no tanque. Ao medir apenas um único tipo de líquido, ele é igual ao volume do produto (GOVP). Ao medir dois líquidos, ele é igual ao volume dos líquidos do produto e da interface (GOVP + GOVI).
GOVU (Gross Observed Volume Ullage (Enchimento do volume bruto observado))A diferença de volume entre a capacidade de operação de um tanque e o volume total no tanque (capacidade de operação – GOVT).
Gravidade API A medição do peso de um líquido de petróleo quando comparado à água. Os valores permitidos variam de 0 a 100 graus API para (6A) e 0 a 85 graus API para (6B).
Gravidade específica A relação de densidade de um líquido perante a densidade da água em condições equivalentes.
H
HART® Um protocolo de comunicação bidirecional que oferece acesso de dados entre instrumentos de campo inteligentes e sistemas host.
I
Interface Adj.; A interface gráfica do usuário (GUI) do software permite que o usuário acesse os protocolos de software (HART®, DDA, MODBUS).
Interface Substantivo; Medição do nível de um determinado líquido quando ele se encontra sob outro líquido.
M
Massa A propriedade de um corpo que indica seu peso dentro de um campo gravitacional, calculada em base à densidade detectada a uma temperatura de referência multiplicada pelo fator de correção por volume (Densidade x VCF).
Método de correção por temperatura Um dos cinco métodos de correção de produto utilizados para corrigir o volume do produto dentro do tanque devido a variações de temperatura de 60 ºF (15.5 °C) que incluem (6A, 6B, 6C, 6C Mod e Tabela personalizada).
Método para cálculo do volume Um dos dois métodos utilizados para medir o volume a partir das medições de nível que incluem esfera e tabela de linearidade.
MODBUS Um protocolo de comunicação em série publicado pela Modicon em 1979 para usar com seus controladores lógicos programáveis (CLPs). Ele se tornou o protocolo de comunicação padrão utilizado na indústria e, atualmente, é o meio mais utilizado para a conexão de dispositivos eletrônicos industriais.
N
NEMA Tipo 4X Um gabinete destinado ao uso em ambientes abertos e fechados que visa oferecer um grau de proteção contra corrosão, poeira, chuva, respingos de água e jatos de água e não deve ser danificado pela formação de gelo no gabinete. Eles não têm a função de proteger contra condições internas como condensação ou congelamento interno.
NPT Norma norte-americana que define a utilização de hastes roscadas cônicas para a união de hastes e acessórios.
NSVP (Net Standard Volume of the Product (Volume líquido padrão do produto))Volume de produto líquido corrigido pela temperatura presente no tanque, requer que o transmissor seja pedido com recursos de medição de temperatura. O NSVP é calculado ao multiplicar o volume do produto líquido pelo fator de correção por volume baseado na temperatura (GOVP x VCF).
Level Plus® CHAMBEREDManual de operação
I 5 I
R
Raio da esfera O raio interno da esfera que contém o líquido e cujo valor é usado para calcular o volume junto com a compensação da esfera.
S
Segurança intrínseca “Intrinsecamente seguro” - Tipo de proteção baseado na restrição de energia elétrica dentro daqueles dispositivos com cabeamento de interconexão que, quando expostos em ambientes com risco de explosão, podem causar a ignição devido ao calor ou às faíscas.
T
Tabela de linearidadeUma tabela de medição em que se estabelece a correlação entre a altura de um recipiente e o volume presente na altura determinada. O transmissor pode conter até 100 pontos.
TEC “Thermal Expansion Coefficient” (coeficiente de expansão térmica) - Valor que estabelece a correlação entre a variação da temperatura de um objeto e a alteração em seu volume. Os valores permitidos variam de 270,0 a 930,0. As unidades TEC são expressas em 10 E-6/Deg F.
Temperatura de referência A temperatura em que é determinada a medição da densidade. Os valores permitidos são 32 °F a 150 °F (0 °C a 66 °C).
V
VCF (Volume Correction Factor (Fator de correção de volume)) Uma tabela de medições que estabelece a correlação entreos pontos de temperatura e os fatores de correção por contração/expansão dos líquidos. O transmissor pode conter até 50 pontos.
3. Introdução
3.1 Objetivo e uso desse manual
Importante:Antes de iniciar a operação do equipamento, leia todo esse documento e siga as informações de segurança.
O conteúdo dessa documentação técnica e de seus diversos anexos pretende fornecer informações sobre montagem, instalação e comissionamento feitos por uma equipe de assistência qualificada de acordo com a norma IEC 60079-14 e as regulamentações locais ou técnicos de assistência treinados pela MTS.
3.2 Símbolos e avisos usados
Os avisos servem para alertar sobre a segurança pessoal e evitar damos ao produto descrito ou dispositivos conectados. Neste documento, os avisos e informações de segurança destinados a evitar perigos que possam prejudicar a vida e a saúde das pessoas ou causar danos materiais estão destacados pelo pictograma definido abaixo.
Símbolo Significado
AVISO Esse símbolo é usado para indicar situações que possam levar a danos materiais e/ou ferimentos pessoais.
4. Instruções de segurança
4.1 Uso pretendido
O transmissor de nível de líquidos deve ser usado para medir o nível de líquido(s) contido(s) em uma estrutura, bem como sua temperatura. O produto pode ser usado somente para as aplicações definidas nos itens 1 a 4 e em conjunto com dispositivos e componentes de terceiros recomendados ou aprovados pela MTS Sensors. Como um pré-requisito para uma operação correta e segura, o produto precisa ser transportado, armazenado, montado e comissionado corretamente e deve ser operado com máximo cuidado.
1. A aplicação não excede a especificação de desempenho do produto no capítulo 5.5.
2. O produto pode ser instalado somente em áreas classificadas como especificadas pelas certificações de aprovação no capítulo 13 seguindo as condições de uso especiais resumidad no capítulo 13 ou em áreas seguras.
3. O(s) líquido(s) que estão sendo medidos são compatíveis com as partes úmidas selecionadas do produto.
4. Os flutuadores MTS devem ser usados para a funcionalidade e aprovações de segurança adequadas.
Level Plus® CHAMBEREDManual de operação
I 6 I
Uso incorreto previsível ConsequênciaConexão incorreta do sensor Possíveis danos a componentes
eletrônicos Consulte o capítulo 7 para conexões elétricas
Instalação incorreta Danos físicos à embalagem Consulte o capítulo 6 para Instalação
Instalação em áreas classificadas não aprovadas
Risco de incêndioConsulte o capítulo 13 para Informações das agências
Temperatura do processo fora da faixa
Degradação do sinal, possíveis danos ao sensor Consulte o capítulo 5.5 para Especificações
Fonte de alimentação fora da faixa Sem comunicação, possíveis danos ao sensor Consulte o capítulo 5.5 para Especificações
Pressão do processo fora da faixa Possíveis danos ao sensor Consulte capítulo 5.5 para Especificações
Compatibilidade com produtos químicos inadequados
Possíveis danos ao sensor, o cliente deve selecionar materiais úmidos que sejam compatíveis com o(s) líquido(s) no tanque
Modificar o sensor Anulação da garantia, anulação da aprovação para áreas classificadas, o cliente deve entrar em contato com a fábrica antes de personalizar a unidade
Aterramento inadequado Possíveis danos ao sensor, toda a proteção comprometida, consulte capítulo 7.6 para Aterramento
Tabela 1: Uso incorreto previsível
4.3 Instalação, comissionamento e operação
1. Use os equipamentos de proteção individual como capacetes, sapatos de segurança, roupas resistentes ao fogo, óculos de segurança, luvas e protetores auriculares.
2. Siga as especificações fornecidas na documentação técnica. 3. Recomenda-se que duas (2) pessoas conduzam a instalação,
o comissionamento e o reparo do transmissor de nível. 4. Certifique-se de que o equipamento usado em um ambiente
classificado seja escolhido e instalado de acordo com as regulamentações que regem a instalação geográfica e a fábrica. Instale somente os equipamentos que estejam em conformidade com os tipos de proteção relevantes às classes, divisões, zonas, categoria, grupo de gás e código de temperatura aplicáveis.
5. Proteja o sensor contra danos mecânicos durante a instalação e a operação.
6. Não use produtos danificados e proteja-os do uso acidental. Identifique os produtos danificados como defeituosos.
7. Conecte o sensor com muito cuidado e preste atenção na polaridade das conexões. A MTS recomenda não fazer conexões quando a energia estiver ligada.
4.2 Uso incorreto previsível 8. Antes de ligar a energia, certifique-se de que a segurança de ninguém será prejudicada ao iniciar o transmissor de líquido e/ou processo.
9. Faça a manutenção preventiva regularmente para evitar riscos à segurança
10. Certifique-se de que nenhum conjunto de cabos esteja solto ou saindo da conexão do borne que pode causar curto-circuito ou outro problema.
11. Certifique-se de nenhum conjunto de cabos, incluindo a blindagem, esteja em contato com o gabinete do módulo eletrônico.
5. Visão geral do produto
O transmissor de nível de líquidos Level Plus® CHAMBERED é um transmissor magnetoestrictivo multifuncional contínuo que fornece nível de produtos, nível de interface e temperatura ao usuário através dos protocolos Modbus, DDA, Analógico (4 a 20 mA) ou HART®. A tecnologia magnetoestritiva é uma das tecnologias de nível mais precisas e repetíveis disponíveis no momento.
A MTS é a criadora e fornecedora de tecnologia magnetoestrictiva e tem atendido as indústrias de nível há mais de 35 anos.
Indústrias• Petrolífera• Gás de petróleo líquido• Farmacêutica• Alimentos e bebidas• Química• Mineração
5.1 Componentes
O transmissor de nível de líquidos Level Plus® CHAMBERED consiste em três componentes principais: um invólucro, haste externa, flutuador e componentes eletrônicos. A variação dos componentes do transmissor permite que o transmissor seja personalizado para quase todas as aplicações.
InvólucrosOs transmissores Level Plus® CHAMBERED estão disponíveis em duas configurações de invólucros: invólucros de cavidade única e de cavidade dupla como mostrado abaixo.As aberturas dos conduítes nos invólucros de cavidade única (opções D, L) e montagem de componentes eletrônicos padrão (7,8) têm abertura NPT 3/4" para aprovações FM e FMC e abertura M20 para aprovações ATEX e IECEx. As aberturas dos conduítes nos invólucros de cavidade única (opções D, L) e montagem de componentes eletrônicos a 90 graus (3,4,5,6) têm abertura NPT 3/4" para todas as aprovações e um adaptador M20 é fornecido para as aprovações ATEX e IECEx. A abertura do conduíte no invólucro de cavidade dupla (opção E) sempre requer a montagem de componentes eletrônicos a 90 graus (3,4,5,6) e é fornecido com uma abertura NPT 3/4" para as aprovações FM e FMC e uma abertura M20 para aprovações ATEX e IECEx.
Level Plus® CHAMBEREDManual de operação
I 7 I
Fig. 1: Invólucro de cavidade única
Fig. 2: Invólucro de cavidade dupla
1
1
2
2
3
3
4
4
A A
B B
C C
D D
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE C LL drawing
1 1
DRAWN BY:
114 mm(4.5 in.)
127 mm(5 in.)
124 mm(4.9 in.)
132 mm(5.2 in.)
87 mm(3.4 in.)
109 mm(4.3 in.)
75 mm(3 in.)
206 mm(8.1 in.)
127 mm(5 in.)
117 mm(4.6 in.)
145 mm(5.7 in.)
1
1
2
2
3
3
4
4
A A
B B
C C
D D
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE C LL drawing
1 1
DRAWN BY:
114 mm(4.5 in.)
127 mm(5 in.)
124 mm(4.9 in.)
132 mm(5.2 in.)
87 mm(3.4 in.)
109 mm(4.3 in.)
75 mm(3 in.)
206 mm(8.1 in.)
127 mm(5 in.)
117 mm(4.6 in.)
145 mm(5.7 in.)
Fig. 3: Invólucro de cavidade única em aço inoxidável
1
1
2
2
3
3
4
4
A A
B B
C C
D D
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE: SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE C
1 1
DRAWN BY:
REV ECO# DESCRIPTION BY DATE
178 mm(7 in.)
135 mm(5.30 in.)
135 mm(5.3 in.)
152 mm(6 in.)
1
1
2
2
3
3
4
4
A A
B B
C C
D D
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE: SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE C
1 1
DRAWN BY:
REV ECO# DESCRIPTION BY DATE
178 mm(7 in.)
135 mm(5.30 in.)
135 mm(5.3 in.)
152 mm(6 in.)
Configurações da haste externaA haste externa é construída de uma variedade de configurações. O CHAMBERED está disponível em uma haste rígida. Para outras hastes, consulte outras opções da MTS como Tank Slayer®, RefineMe®, SoClean®, e/ou USTDII. USTDII.Flutuadores
1
1
2
2
3
3
4
4
A A
B B
C C
D D
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE C Marketing
1 1
DRAWN BY:
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
Order length
304.8mm (12 in)
Pipe diameter16mm (0.625 in)
Tip of transmitter
Tank Flange
1 in NPT Adjustablecompression fitting, male
127mm [5 in ]
Order Length
Pipe diameter (0.625 in. dia)constructed of 316l stainless steel
Sanitary process connection (sanitary cap)
74 mm (2.9 in.) minInactive zone
Order Length
54 mm (2.1 in.)minimum
Fig. 4: Invólucro de cavidade única em aço inoxidável
Os transmissores CHAMBERED oferecem diversos flutuadores para diferentes aplicações como aço inoxidável e Hastelloy tanto para nível de produto e nível de interface. Para detectar o nível de interface de forma precisa, é necessário haver uma diferença de pelo menos 0,05 em gravidades específicas entre o produto e o líquido de interface. Para informações detalhadas sobre os flutuadores, consulte ‘Catálogo de acessórios’, (código de catálogo da MTS 551103).
Para assistência com a seleção de um flutuador específico para sua aplicação, entre em contato Suporte técnico com as seguintes informações:• Gravidade específica de líquido(s) que está sendo medido• Temperatura de processo• Tamanho de abertura do processo• Pressão do recipiente
Level Plus® CHAMBEREDManual de operação
I 8 I
Os transmissores CHAMBERED devem ser usados com um flutuador que tem um peso de compensação e feito de aços inoxidáveis ou Hastelloy® C. Isso permite que o flutuador permaneça em contato com a haste para evitar o acúmulo de uma descarga eletrostática. Para informações detalhadas sobre os flutuadores, consulte ‘Catálogo de acessórios’, (código de catálogo da MTS 551103).
Componentes eletrônicos internosTodos os transmissores são acompanhados por dois componentes eletrônicos de um elemento de detecção e uma unidade controladora. Elementos rígidos de detecção são padrão em CHAMBERED. A unidade controladora consiste em até três placas eletrônicas e um display.
A função de detecção da temperatura é opcional com o transmissor CHAMBERED. O dispositivo de detecção de temperatura é um termômetro digital montado dentro do conjunto de haste externa do transmissor. O CHAMBERED pode ser pedido com os pontos de temperatura 1, 5, 12 ou 16.
DisplayTodos os transmissores de nível líquido da série LP são enviados com um estilo (MTS Código de peça 404108) que deve ser usado para manipular o display. Para invólucros de cavidade simples e dupla, o estilo foi desenvolvido para permitir a programação da unidade sem remover o invólucro. Quando usar o estilo, certifique-se de alinhá-lo com o contorno da forma ao redor dos botões na mesma orientação. Se o estilo não estiver devidamente alinhado, o display pode não funcionar corretamente. A senha para entrar no menu é 27513. Para mais detalhes, consulte manual de interface Modbus específico para o protocolo (Cód. peça MTS 551700), o manual de interface DDA (Cód. peça MTS 551701) e o manual de interface HART® (Cód. peça MTS 551702).
Fig. 5: Estilo (código de peça MTS 404108)
AcessóriosA MTS também oferece uma série de displays, invólucros, conversores e outros acessórios, consulte o ‘Catálogo de acessórios’, (código de catálogo da MTS 551103).
5.2 Precisão
Para transmissores magnetoestrictivo, a precisão inerente é medida em termos de não linearidade. A não linearidade é uma imperfeição nas ondas guiadas que se reflete na linearidade da saída do transmissor. As tolerâncias da MTS refletem uma não linearidade máxima de ±1 mm. A MTS é capaz de alcançar tolerâncias ao produzir todas as suas próprias ondas guiadas com uma liga proprietária e testa todos os transmissores antes que deixem a fábrica.
5.3 Garantia
Importante:Entre em contato com o suporte técnico ou com atendimento ao cliente para obter ajuda se suspeitar que o transmissor não está trabalhando corretamente. O suporte técnico pode auxiliá-lo com a detecção e resolução de falhas, substituição de peças e informações sobre autorização de devolução de materiais (RMA), se necessárias.
Todos os transmissores Level Plus® vêm com dois anos de garantia limitada a partir da data de expedição da fábrica. Porém, é possível adquirir a garantia estendida adicional. Um número de autorização de devolução de materiais (RMA) é necessário e deve acompanhar todos transmissores devolvidos. Qualquer unidade usada em um processo deve estar devidamente limpo de acordo com as normas OSHA antes de serem devolvidos à fábrica. A folha de dados de segurança de materiais (MSDS) também deve acompanhar o transmissor que foi usado em qualquer processo.
Fig. 6: Display
Level Plus® CHAMBEREDManual de operação
I 9 I
5.4 Identificação do número do modelo
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
L P C
a b c d e f g h i j k l m n o p
a Modelo de sensor
L P C Transmissor de Nível CHAMBERED
b Saída
M MODBUS
D DDA
3 1 linha com HART®
6 1 linha com HART® e SIL 2
d Montagem dos componentes eletrônicos
3 dobrar invólucro superior esquerdo 90°
4 dobrar invólucro superior direito 90°
5 dobrar invólucro inferior esquerdo 90°
6 dobrar invólucro inferior direito 90°
7 Montagem superior
8 Montagem inferior
f Materiais de construção (partes úmidas)*
1 316L aço inoxidável
e Haste do sensor
B Haste OD 5/8"
R Haste OD 1/2"
Y Haste OD 10 mm
c Tipo de invólucro
D Cavidade única c/ display
E Cavidade dupla c/ display
L Cavidade única Ç c/ display
*/ Entre em contato com a fábrica para outros materiais
g Tipo de conexão do processo
X Nenhum
h Tamanho de conexão do processo
X Nenhum
i Número de DTs (termômetros digitais)
0 Nenhum
j Colocação do DR
X Nenhum
l Método de proteção
F À prova de explosão / à prova de chamas (somente para o tipo de invólucro D, E ou L)
I Intrinsecamente seguro
X Sem aprovações
m Grupo de combustível
A Grupo A (não está disponível com o órgão notificado “C = CEC (FMC)” e método de proteção “F = à prova de chamas/à prova de explosão”)
B Grupo B
C Grupo C
D Grupo D
3 IIC (intrinsecamente seguro somente)
4 IIB + H2 (à prova de explosão / à prova de chamas somente)
X Nenhum
Continuação na próxima página…
k Órgão notificado
B INMETRO
C CEC (FMC)
E ATEX
F NEC (FM)
I IEC
K KC
N NEPSI
T CML/TIIS
P CCOE
X None
Level Plus® CHAMBEREDManual de operação
I 10 I
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
L P T
a b c d e f g h i j k l m n o p
n Unidade de medição
M Milímetros (métricos)
U Polegadas (EUA tradicional)
p Especial
S Produto padrão
o Comprimento (sem espaços decimais)*
X X X X X Haste rígida: 12 a 144 pol (código de 01200 a 14400)
X X X X X Haste rígida: 305 a 3658 mm (código de 00305 a 03658)
AVISO
Acessórios como flutuadores, cabos e displays remotos devem ser pedidos separadamente. Todos os acessórios são mostrados no Catálogo de acessórios (código de peça MTS 551103).
*/ Entre em contato com a fábrica para comprimentos maiores
Level Plus® CHAMBEREDManual de operação
I 11 I
5.5 Dados técnicos
Saída de nível
Variável medida Product Level (nível de produto)
Protocolo/Sinal de saída Modbus RTU, DDA, analógico (4 à 20 mA), HART®
Comprimento de pedido305 mm (12 pol.) a 3658 mm (144 pol.) (o comprimento de pedido é igual à faixa de medição mais a zona inativa / entre em contato com a fábrica se precisar de comprimentos maiores)
Precisão inerente ±1 mm (0,039 pol.)
Repetibilidade 0,001% F.S. ou 0,381 mm (0,015 pol.), o que for maior * (qualquer direção)
Saída de temperatura
Variável medida Temperaturas médias e multipontos (Modbus, DDA)Temperatura ponto único (analógico, HART®)
Precisão de temperatura (Modbus, DDA) Faixa ±0,2 °C (0,4 °F), −40 a −20 °C (−40 a −4 °F),Faixa ±0,1 °C (0,2 °F), −20 a +70 °C (−4 a +158 °F),Faixa ±0,15 °C (0,3 °F), +70 a +100 °C (+158 a +212 °F),Faixa ±0,5 °C (0,9 °F), +100 a +105 °C (+212 a 221 °F),
Precisão de temperatura (analógica, HART®) Faixa ±0,28 °C (0,5 °F), −40 a +105 °C (−40 a +221 °F)
Componentes eletrônicos
Tensão de entrada 10,5 a 28 Vcc
À prova de falha Alta, escala completa (Modbus, DDA)Baixa, 3,5 mA padrão ou alta, 22,8 mA (analógica, HART®)
Proteção contra polaridade reversa Diodo em série
EMC EN 61326-1, EN 61326-2-3, EN 61326-3-2, EN 61000-6-2, EN 61000-6-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11
Meio ambiente
Grau de proteção do gabinete NEMA Tipo 4X, IP65
Umidade Umidade relativa de 0 a 100%, sem condensação
Temperatura de operação Componentes eletrônicos: −40 a +71 °C (−40 a +160 ºF)Elemento de detecção: −40 a +125 °C (−40 a +257 °F) (entre em contato com a fábrica para as faixas específicas de temperaturas)
Materiais 316L aço inoxidável, alumínio coberto com epóxi
Instalação em campo
Dimensões do invólucro Cavidade única: 145 mm (5,7 pol.) L × cerca de 127 mm (5 pol.) P × 109 mm (4,3 pol.) HCavidade dupla: 117 mm (4,6 pol.) L × cerca de 127 mm (5 pol.) P × 206 mm (8,1 pol.) HCavidade única em aço inoxidável: 178 mm (7,1 pol.) L × cerca de 135 mm (5,3 pol.) P × 153 mm (6 pol.) H
Montagem
Mangueira flexível 1 pol. Conexão MNPT ou BSPP ajustável, montagem em flange
Fiação
Conexões Cabo blindado com 4 fios ou par trançado
Conexões elétricas
Cavidade única e dupla ¾ pol. Abertura do conduíte, M20 para versão ATEX/IECEx
NEMA Tipo 4X ½ pol. Abertura do conduíte FNPT
Display
Variáveis medidas Nível do produto, nível de interface e temperatura
*/ Apenas com flutuadores MTS recomendados
Level Plus® CHAMBEREDManual de operação
I 12 I
Inactive Zone74 mm (2.9 in.)
Inactive Zone54 mm (2.1 in.)
Orderlength
MeasuringRange
127 mm(5 in.)
(Circle one)4 mA or 20 mA
Setpoint
(Circle one)4 mA or 20 mA
Setpoint
Order LengthStandard
74 mm (2.9 in.)Standard
Level Plus
145 mm(5.7 in.)
PressureBarrier
ElectronicHead 155 mm
(6.1 in.)Protection
MethodI or X
195 mm(7.7 in.)
Protection Method
F
6. Instalação e montagem
6.1 Treinamento
Aviso: Quando a haste/mangueira do transmissor de nível da Série LP for instalado ou removido do tanque, ocorre a liberação de vapores inflamáveis. Tome todos os cuidados necessários quando instalar ou remover o transmissor de nível por causa da liberação dos vapores inflamáveis.
A instalação deve ser feita por uma equipe qualificada de acordo com a norma IEC 60079-14 e as regulamentações locais ou por técnicos treinados da MTS. A MTS oferece treinamento presencial e baseado em web para instalação, comissionamento, manutenção e reparo. A MTS também oferece serviços direto da fábrica para essas mesmas funções. Entre em contato com a MTS para discutir as opções de treinamento ou atendimento direto antes de começar.
6.2 Ferramentas
• Alicate bico de papagaio• Chave de fenda comum• Ferramentas adicionais podem ser necessárias, dependendo do
fabricante do MLG
6.3 Etapas de instalação
CuidadoRecomendamos não fazer a montagem e a instalação desse transmissor sozinho. Para assegurar a montagem correta e segura do transmissor CHAMBERED, são necessárias pelos menos duas (2) pessoas. Além disso, o uso de luvas é recomendado. EPIs, como sapatos, óculos de segurança, capacete e roupas antichamas, podem ser necessários nas áreas de trabalho.
1. Consulte a Seção 4.3 antes de iniciar. 2. Execute as etapas 1 a 9 na seção 8.4.1 para Modbus ou DDA.
Execute as etapas 1 a 8 na seção 8.4.2 para analógico. 3. CHAMBERED deve ser instalado na câmara do MLG. Instalação
típica usa um suporte de montagem ou braçadeiras de mangueira para prender o CHAMBERED ao MLG. Contate o fabricante do MLG para obter detalhes de instalação.
6.4 Montagem
O método de montagem do transmissor depende de qual MLG está sendo usado. Montagem típica do CHAMBERED diretamente ao MLG.
Fig. 7: Montagem do CHAMBERED, flange inferior
CuidadoQuando montar o transmissor de nível em um MLG, o espaçamento mínimo de 5 polegadas deve ser mantido entre o cabeçote do gabinete e a barreira de pressão. O gabinete e a barreira de pressão são identificados na imagem a seguir.
CuidadoA classificação da temperatura ambiente, Ta= -40 °C (-40 °F) a 71 °C (160 °F), não deve ser excedida por causa da montagem do transmissor de nível no MLG e da exposição à temperatura do processo.
Montagem diretaNa maior parte das aplicações, o transmissor CHAMBERED pode ser montado diretamente ao MLG através de braçadeiras de mangueira. Consulte o fabricante do MLG para detalhes.
Level Plus® CHAMBEREDManual de operação
I 13 I
Fig. 10: Montagem do CHAMBERED, flange superior e inferior
(Circle one)
PressureBarrier
ElectronicHead
4 mA or 20 mA
Setpoint
Order LengthStandard
(Circle one)4 mA or 20 mA
Setpoint
74 mm (2.9 in.)Standard
74 mm (2.9 in.)
54 mm (2.1 in.)
114 mm(4.5 in.)
145 mm(5.7 in.)
127 mm(5 in.)Level Plus
7. Conexões elétricas
7.1 Informações básicas
Uma conexão intrinsecamente segura típica para o transmissor Level Plus® CHAMBERED inclui barreiras protetoras de segurança, uma fonte de alimentação e um dispositivo de leitura ou monitoração. Consulte as informações da agência no capítulo 13.
Uma típica conexão à prova de explosão/à prova de chamas para o transmissor Level Plus® CHAMBERED inclui uma fonte de alimentação e um dispositivo de leitura ou monitoração. Todo o cabeamento deve ser feito em conduítes aprovados com isolamentos como especificado pelo código para instalações elétricas local. Consulte as informações da agência no capítulo 13.
7.2 Recomendações de segurança
Certifique-se de que: 1. Siga sempre os códigos para instalações elétricas nacionais
e locais e observe a polaridade ao fazer as conexões elétricas. 2. Nunca faça conexões elétricas com o transmissor CHAMBERED
ligado à rede de energia. 3. Certifique-se de que nenhum conjunto de cabos esteja solto ou
saindo da conexão do borne que pode causar curto-circuito ou outro problema.
4. Certifique-se de nenhum conjunto de cabos, incluindo a blindagem, esteja em contato com o gabinete do módulo eletrônico.
5. O gabinete do módulo eletrônico é aterrado através de um circuito interno e é eletricamente isolado do invólucro à prova de explosão.
7.3 Topologias industriais
Existem quatro topologias que estão descritas e ilustradas a seguir. Porém, a MTS não recomenda a topologia daisy chain (encadeamento).
Ponto a pontoA topologia ponto a ponto consiste em ter apenas um dispositivo na linha como mostrado na Fig. 8. Essa topologia, geralmente, não é usada com uma rede do barramento porque ele não aproveita a vantagem de ter vários dispositivos em uma linha.
PLC
Fig. 8: Topologia ponto a ponto
Barramento com antenaO barramento com topologia com antena tem um cabo tronco principal em que os dispositivos são conectados através de sua própria antena em uma caixa de junção como mostrado na Fig. 9. As topologias barramento com antena e árvore também podem ser usada juntas para formar uma topologia híbrida.
Fig. 9: Topologia barramento com antena
PLC
Level Plus® CHAMBEREDManual de operação
I 14 I
Alinhamento da árvoreA topologia em árvore é muito semelhante à topologia barramento com antena, mas a diferença principal é que a topologia em árvore utiliza uma caixa central comum a todos os transmissores, como mostrado na Fig. 11. Os barramentos com topologia com antena e em árvore também podem ser usados juntos para formar uma topologia híbrida.
Fig. 11: Topologia em árvore
PLC
Daisy chain (encadeamento)A topologia daisy-chain utiliza um único cabo que é conectado a todos os transmissores com o calor interconectado a todos os dispositivos de campo. Quando usar essa topologia, certifique-se de que a prática de fiação permita que um transmissor seja desconectado sem desligar a linha toda como mostrado na Fig. 12. A MTS não recomenda a topologia daisy-chain (encadeamento).
Fig. 12: Topologia Daisy-chain (encadeamento)
PLC
Fig. 13: Instalação do conduíte elétrico
Tabela 2: Especificações e parâmetros do cabo
7.4 Recomendações de cabos
Consulte a “Tabela 2” abaixo para obter as especificações gerais dos tipos de cabos para o transmissor Level Plus® CHAMBERED.
Especificações de cabo
7.5 Conduíte elétrico
Parâmetro Especificação
Bitola mínima do cabo Ø 0,51 a 1,6 mm (24 a 14 AWG)
Tipo de caboPar trançado simples ou múltiplo com blindagem comum; espessura mínima de isolamento 0,25 mm (0,010 pol.)
Capacitância Menos de 98 pF/m (30 pF/pés)
AVISO
1. Aperte a tampa do invólucro (as tampas frontal e traseira se for cavidade dupla) para parada total contra o O-ring.
2. Use apenas a entrada lateral do conduíte. 3. Em áreas muito úmidas, use uma conexão de vedação do
conduíte com respiro para reduzir a entrada de umidade. 4. Para Instalações de divisão, uma vedação de conduíte aprovada
é necessária em 457 mm (18 pol.) do gabinete. 5. Para Instalações em zonas, uma vedação de conduíte aprovada
é necessária em 50 mm (2 pol.) do gabinete.
Conduit sealing fitting
NPT or BSPP FittingDo not over-tightencompression fitting!
Interface float(ordered
separately)
Product float(ordered
separately)
View shown withcover removed
Plugged entryDo not use(see notes)
3/4 NPT or M20 conduit accessUse NPT conduit fitting only!
Conduit(flexible or rigid)
Conduit fromcontrol room
Level Plus®
Do not remove cover with circuit energized in hazardous locations!
Follow safe work procedures.
Level Plus® CHAMBEREDManual de operação
I 15 I
7.6 Aterramento
7.6.1 Aterramento de segurança
Aviso:O aterramento do transmissor através de uma conexão de conduíte roscado não atende os requisitos como um aterramento de segurança para o sensor.
Há dois métodos para fazer uma conexão de aterramento dos componentes eletrônicos. Porém, o método deve resultar em uma resistência inferior a 1 Ω. Consulte a ‘Tabela 3’ para referências de barreira de segurança.
• Passe uma conexão de aterramento pelo conduíte e conecte-o diretamente a terminal de aterramento dentro do invólucro.
• Passe uma conexão de aterramento diretamente ao terminal de aterramento na parte externa do invólucro.
7.6.2 Aterramento blindado
Aviso:O aterramento da blindagem não atende as especificações de segurança para o sensor.
O desempenho de imunidade do sensor de fontes externas de pico, queima, radiofrequência, emissões radiadas e outros ruídos depende de um aterramento adequado da blindagem do cabo de comunicação. A blindagem do cabo de comunicação deve ser do tipo trançada e conectada ao terminal de aterramento interno ao invólucro do sensor.
Passe-a por um conduíte metálico contínuoO conduíte metálico contínuo dedicado propicia ao invólucro do sensor um nível de proteção de blindagem contra interferência externa e um nível de aterramento. Nesse caso, um cabo lindado tipo película com um dreno conectado ao terminal de aterramento interno pode ser suficiente. O compartilhamento do conduíte metálico com outros cabos prejudicará o desempenho da blindagem do cabo de comunicação e, consequentemente, do sensor. Nesse caso, recomenda-se um cabo blindado trançado conectado ao terminal de aterramento interno. Em todos os casos, o cabo de comunicação deve ficar em paralelo a qualquer cabo que gere interferências em um conduíte ou a cabos que gerem interferência próximos ao conduíte que podem prejudicar o desempenho do sensor.
Instalação sem um conduíteEm poucas aplicações ou quando a segurança não for necessária, não é necessário usar um conduíte metálico. A blindagem do cabo de comunicação deve ser do tipo trançada e conectada ao terminal de aterramento interno ao invólucro do sensor. Alternativamente, pode usar uma glande do cabo EMC com aprovação de segurança para aterrar a blindagem. Entre em contato com a MTS para informações antes de usar um desses prensa-cabos.
NECCorrentes não desejadas (linhas de aterramento) é uma violação ao código NEC e um risco à segurança.
7.7 Barreiras de segurança
Consulte a Tabela 3 para os parâmetros da entidade e a Tabela 4 para exemplo de barreiras de segurança.
Parâmetros da entidade
Fonte digital(1 por LT)
Ui = 28 Vcc
Ii = 100 mA
Ci = 0,0 µF
Li = O mH
Pi = 700 mW
Comunicação digital(2 por LT)
Ui = 8,6 Vcc
Ii = 10 mA
Ci = 0,0 µF
Li = 0,0 mH
Pi = 21,5 mW
Analógico(1 por linha)
Ui = 28 Vcc
Ii = 120 mA
Ci = 0 µF
Li = 5 µH
Pi = 840 mW
Tabela 3: Referências de parâmetros de entidade da barreira de segurança
Tabela 4: Referências de parâmetros de entidade da barreira de segurança
Fornecedor STAHL STAHL STAHL
Tipo9001/01-280-100-101
9001/51-280-110-141
9001/01-086-010-101
Tensão máxima 28 Vcc 28 Vcc 8,6 VccCorrente máxima(cada canal) 100 mA 110 mA 10 mA
Potência máxima(cada canal) 700 mW 770 mW 21,5 mW
Número de canais 1 1 1
Interface Modbus/DDA HART® Modbus/DDA
Level Plus® CHAMBEREDManual de operação
I 16 I
8. Comissionamento
8.1 Treinamento
O comissionamento deve ser feito por uma equipe qualificada de acordo com a norma IEC 60079-14 e as regulamentações locais ou por técnicos treinados da MTS. A MTS oferece treinamento presencial e baseado em web para instalação, comissionamento, manutenção e reparo. A MTS também oferece serviços direto da fábrica para essas mesmas funções. Entre em contato com a MTS para discutir as opções de treinamento ou atendimento direto antes de começar.
8.2 Ferramentas
• Alicate bico de papagaio• Conversor RS485 em USB (Cód. peça MTS 380114)[Modbus e DDA]• PC com Windows instalado• Fonte de alimentação linear e regulamentada• Software de configuração da MTS• Conversor HART® em USB (Cód. peça MTS 380068)
8.3 Software de configuração
A MTS oferece um software de configuração que é enviado com o transmissor de nível e também está disponível em www.mtssensors.com. O software de configuração deve ser usado para instalação, comissionamento e detecção e resolução de falhas. Para mais detalhes sobre como usar o software de configuração, consulte o manual de interface Modbus (Cód. peça MTS 551700), o manual de interface DDA (Cód. peça MTS 551701) e o manual de interface HART® (Cód. peça MTS 551702).
8.4 Etapas de comissionamento
8.4.1 Modbus ou DDA
1. Consulte a Seção 4.3 antes de iniciar. 2. Remova o transmissor de nível da embalagem de entrega. 3. Monte no MLG e a unidade de teste com o flutuador do MLG. 4. Conecte a energia, conversor RS485 à USB e PC. 5. Abra o software de configuração da MTS. 6. Estabeleça a comunicação. 7. Para interface DDA – Configure um endereço. Padrão 192. 8. Para a interface Modbus – Configure um endereço, endereço
padrão 247. 9. Desconecte a energia e a comunicação.
10. Instalação completa na seção 6.4. 11. Um técnico qualificado deve realizar a medição manual. Insira
a medição manual no software de configuração MTS e calibre. 12. Salve todas as configurações com um arquivo de backup de
acordo com o nome do local e número do tanque.
8.4.2 HART®
1. Consulte a Seção 4.3 antes de iniciar. 2. Remova o transmissor de nível da embalagem de entrega. 3. Monte no MLG e a unidade de teste com o flutuador do MLG. 4. Conecte a energia, conversor HART® à USB e PC 5. Abra o software de configuração da MTS. 6. Estabeleça a comunicação. 7. Configure/atualize os valores de referência 4 e 20 mA. 8. Desconecte a energia e a comunicação. 9. Instalação completa na seção 6.4.
10. Um técnico qualificado deve realizar a medição manual. Insira a medição manual no software de configuração MTS e calibre.
11. Salve todas as configurações com um arquivo de backup de acordo com o nome do local e número do tanque
AVISO
Para mais detalhes, consulte manual de interface Modbus específico para o protocolo (Cód. peça MTS 551700), o manual de interface DDA (Cód. peça MTS 551701) e o manual de interface HART® (Cód. peça MTS 551702).
Level Plus® CHAMBEREDManual de operação
I 17 I
9. Manutenção
9.1 Treinamento
A manutenção deve ser feita por uma equipe qualificada de acordo com a norma IEC 60079-14 e as regulamentações locais ou por técnicos treinados da MTS. A MTS oferece treinamento presencial e baseado em web para instalação, comissionamento, manutenção e reparo. A MTS também oferece serviços direto da fábrica para essas mesmas funções. Entre em contato com a MTS para discutir as opções de treinamento ou atendimento direto antes de começar.
9.2 Ferramentas
• Alicate bico de papagaio• Chave de fenda comum
9.3 Inspeção
Abaixo, estão alguns itens padrão que devem ser inspecionados regularmente para garantir que o transmissor de nível e o ambiente ao redor estejam em condições de operação.
• A etiqueta de área classificada está presente e legível• A aprovação da área está correta para instalação• Não há modificações não autorizadas visíveis• As conexões elétricas estão firmes• O gabinete do O-ring está em boas condições• Não entrada de água (pó branco)• Não danos visíveis ao cabo• A vedação do conduíte ou do prensa-cabo está em boas condições• O aterramento está em boas condições• As roscas do gabinete de cavidade única ou dupla não
estão danificadas• O invólucro e o o-ring não estão danificados nem trincados• Não há corrosão na partes visíveis• As placas de circuito interno estão limpas e sem danos
9.4 Manutenção preventiva
Geralmente, os transmissores de nível Level Plus® não precisam de manutenção preventiva, mas isso depende da aplicação. Para aplicações de uso geral, em que não há risco de acúmulo na mangueira flexível e/ou no flutuador, a manutenção preventiva não é necessária, mas recomenda-se uma inspeção regular. Para aplicações em que há o potencial de acúmulo na mangueira flexível e/ou nos flutuadores, a manutenção preventiva é necessária.
10. Reparos
10.1 Política de RMA (autorização de material devolvido)
Todos os transmissores Level Plus® vêm com dois anos de garantia limitada a partir da data de expedição da fábrica. Um número de autorização de devolução de materiais (RMA) é necessário e deve acompanhar todos transmissores devolvidos. Qualquer unidade usada em um processo deve estar devidamente limpo de acordo com as normas OSHA antes de serem devolvidos à fábrica. A folha de dados de segurança de materiais (MSDS) também deve acompanhar o transmissor que foi usado em qualquer processo.
10.2 Treinamento
Os reparos devem ser feitos por uma equipe qualificada de acordo com a norma IEC 60079-14 e as regulamentações locais ou por técnicos treinados da MTS. A MTS oferece treinamento presencial e baseado em web para instalação, comissionamento, manutenção e reparo. A MTS também oferece serviços direto da fábrica para essas mesmas funções. Entre em contato com a MTS para discutir as opções de treinamento ou atendimento direto antes de começar.
10.3 Ferramentas
• Alicate bico de papagaio• Chave Phillips, chave de fenda• Chave de fenda comum• Conversor RS485 em USB (Cód. peça MTS 380114)
[Modbus e DDA]• PC com Windows instalado• Fonte de alimentação linear e regulamentada• Conversor HART® em USB (Cód. peça MTS 380068)
Importante:Entre em contato com o suporte técnico ou com atendimento ao cliente para obter ajuda se suspeitar que o transmissor não está trabalhando corretamente. O suporte técnico pode auxiliá-lo com a detecção e resolução de falhas, substituição de peças e informações sobre autorização de devolução de materiais (RMA), se necessárias.
Level Plus® CHAMBEREDManual de operação
I 18 I
10.4 Detecção e resolução de falhas
10.5 Software de configuração
A MTS oferece um software de configuração que é enviado com o transmissor de nível e também está disponível em www.mtssensors.com. O software de configuração deve ser usado para instalação, comissionamento e detecção e resolução de falhas. Para mais detalhes sobre como usar o software de configuração, consulte o manual de interface Modbus (Cód. peça MTS 551700), o manual de interface DDA (Cód. peça MTS 551701) e o manual de interface HART® (Cód. peça MTS 551702).
Indício Possível causa AçãoSem comunicação com o transmissor
Sem energia Verifique a tensão no transmissor
Fiação incorreta Diagrama de instalação de referência capítulo 13
Endereço incorreto Padrão de fábrica de DDA é ‘192’, para o Modbus é ‘247’
Software incorreto Confirme o software corretoProtocolo incorreto Confirme se o software
e o transmissor têm o mesmo protocolo
Faltaerro do ímãou saída de alarme
O flutuador não é reconhecido
Confirme se o flutuador está conectado
O flutuador está na zona morta
Levante o flutuador para ver se o erro é eliminado
Número incorreto de flutuadores selecionado
Confirme se a quantidade de flutuadores no transmissor e a quantidade de flutuadores que o transmissor está procurando é a mesma.
Erro no nível de disparo
É necessário ajustar o ganho
Entre em contato com a fábrica
SE é danificado Entre em contato com a fábrica
Nível mín. de disparo muito alto
Entre em contato com a fábrica
Erro de cálculo de volume
Nenhuma tabela de linearidade inserida
Insira uma tabela de linearidade
Nível fora da tabela de linearidade
Insira os pontos extras na tabela de linearidade
Tabela de linearidade incorreta
Verifique as entradas dos valores
Erro de VCF Nenhuma tabela de VCF inserida
Insira a tabela de VCF
Tabela de VCF incorreta
Verifique as entradas do valor de VCF
Tabela 5: Referência de detecção e resolução de falhas
11. Peças de reposição
Abaixo está a lista de peças de reposição para as série LP como display, módulo eletrônico, elemento de detecção e mangueira flexível. Entre em contato com o suporte técnico da MTS se houver alguma dúvida.
12. Interface
O CHAMBERED está disponível com várias saídas incluindo Modbus, DDA e HART®. Esse Manual de operação e instalação inclui todas essas saídas. Cada saída tem seu próprio Manual de interface especializado que deve ser consultado para informações extras sobre a saída específica. Para a norma SIL, consulte o manual de segurança SIL, (Cód. peça MTS 551851).
12.1 MODBUS
A MTS oferece Modbus RTU em uma rede half-duplex RS485. Para mais informações, consulte o Manual de interface Modbus (Cód. de peça MTS 551700).
12.2 DDA
A MTS oferece DDA (acesso digital direto) em uma rede half-duplex RS485. Para informações adicionais, consulte o Manual de interface DDA, (cód. de peça MTS 551701).
12.3 HART®
A MTS oferece HART® em um sinal de 4 a 20 mA. Para mais informações, consulte o Manual de interface HART® (Cód. peça MTS 551702).
Elemento de detecçãoMude o terceiro dígito no número do modelo de T para E. Por exemplo, o elemento de detecção para o número do modelo LPTME1N11B5FFIAU50000S ficaria LPEME1N11B5FFIAU50000S.
Mangueira flexívelMude o terceiro dígito no número do modelo de T para P. Por exemplo, a substituição da mangueira flexível para o número do modelo LPTME1N11B5FFIAU50000S seria LPPME1N11B5FFIAU50000S.
Peças de reposição Cód. peça
Display 254732
Saída Invólucro Cód. peça
Linha simples HART® A, B, C, D, E 254731-1
Linha dupla HART® A, B, C, D, E 254731-2
MODBUS A, B, C, D, E 254731-3
DDA A, B, C, D, E 254731-4
Linha simples HART® L 254731-5
Linha dupla HART® L 254731-6
MODBUS L 254731-7
DDA L 254731-8
Linha simples SIL A, B, C, D, E 254850-1
Linha dupla SIL A, B, C, D, E 254850-2
Linha simples SIL L 254850-5
Linha dupla SIL L 254850-6
Level Plus® CHAMBEREDManual de operação
I 19 I
Órgão notificado Método de proteção Classificação PadrãoC = CEC I = Segurança
intrínsecaClasse I, Divisão 1, Grupos ABCD T4Classe I, Zona 0/1, Ex ia IIC T4Ta = -50 °C a 71 °C IP65
CAN C22.2 Nº 157-92:2012CSA C22.2 Nº 1010.1:2004CAN/CSA C22.2 Nº 60079-0:2011CAN/CSA C22.2 Nº 60079-11:2014CAN/CSA C22.2 Nº 60529:2005
F = À prova de explosão / à prova de chamas
Classe I, Divisão 1, Grupo BCD T6 a T3Ex db IIB+H2 T6 a T3 Ga/GbTa = -40 °C a 71 °C IP65
CSA C22.2 Nº 0.4-04:R2013CSA C22.2 Nº 0.5:R2012CSA C22.2 Nº 0-10:R2015CSA C22.2 Nº 30:R2012CAN/CSA C22.2 Nº 60079-0:2015CAN/CSA C22.2 Nº 60079-1:2016CAN/CSA 622.2 Nº 60079-26:2016CAN/CSA C22.2 Nº 61010.1:2012CSA C22.2 Nº 60529:R2010
E = ATEX I = Segurança intrínseca
II 1/2 G Ex ia IIC T4Ta = -50 °C a 71 °C IP65
EN 60079-0:2012EN 60079-11:2012EN 60529:1991 + A1:2000
F = À prova de explosão
II 1/2 G Ex db IIB+H2 T6 a T3 Ga/GbTa = -40 °C a 71 °C IP65
EN 60079-0:2012+A11:2013EN 60079-1:2014EN 60079-26:2015EN 60529:1991 + A2:2013
F = NEC I = Segurança intrínseca
Classe I, Divisão 1, Grupos ABCD T4Classe I, Zona 0/1, AEx ia IIC T4Ta = -50 °C a 71 °C IP65
FM 3600:2011FM 3610:2010FM 3810:2005ANSI/ISA 60079-0:2013ANSI/ISA 60079-11:2014ANSI/IEC 60529:2004
F = à prova de explosão /À prova de chamas
Classe I, Divisão 1, Grupos ABCD T6 a T3Classe I, Divisão 1, Grupo BCD T6 a T3Classe I, Zona 0/1, AEx db IIB+H2 T6 a T3 Ga/GbTa = -40 °C a 71 °C IP65
FM 3600:2011FM 3615:2006FM 3810:2005ANSI/ISA 60079-0:2013ANSI/UL 60079-1:2015ANSI/UL 60079-26:2017ANSI/IEC 60529:2004
I = IEC I = Segurança intrínseca
Ex ia IIC T4 Ga/GbTa = -50 °C a 71 °C IP65
IEC 60079-0:2011IEC 60079-11:2011
F = À prova de explosão
Ex db IIB+H2 T6 a T3 Ga/GbTa = -40 °C a 71 °C IP65
IEC 60079-0:2007-10IEC 60079-1:2007-04IEC 60079-26:2014-10IEC 60529:2013
B = INMETRO I = Segurança intrínseca
Ex ia IIC T4 Ga/GbTa = -50 °C a 71 °C IP65
ABNT NBR IEC 60079-0ABNT NBR IEC 60079-11ABNT NBR IEC 60529
F = À prova de chamas
Ex db IIB+H2 T6 a T3 Ga/GbTa = -40 °C a 71 °C IP65
ABNT NBR IEC 60079-0ABNT NBR IEC 60079-1ABNT NBR IEC 60079-26ABNT NBR IEC 60529
Continuação na próxima página…
13. Informações da agência
13.1 Visão geral das aprovações
O órgão notificado está designado no 13º dígito do número do modelo e o método de proteção é designada no 14º dígito do número do modelo. Esses dois dígitos do número do modelo especificam a aprovação da área classificada fornecida com o transmissor de nível selecionado.Abaixo, estão as informações detalhadas sobre as aprovações NEC, CEC, IEC E ATEX. A MTS também tem as aprovações do INMETRO, NEPSI, KC, CCoE e CML (Japão). Entre em contato com a MTS se tiver alguma dúvida sobre a aprovação de perigos necessária.
Tabela 6: Aprovações das agências, parte 1
Level Plus® CHAMBEREDManual de operação
I 20 I
Tabela 7: Aprovações das agências, parte 2
Órgão notificado Método de proteção Classificação PadrãoN = NEPSI I = Segurança
intrínsecaEx ia IIC T4 Ga/GbTa = -50 °C a 71 °C IP65
GB 3836.1-2010GB 3836.4-2010GB 3836.20-2010
F = À prova de chamas
Ex db IIB+H2 T6 a T3 Ga/GbTa = -40 °C a 71 °C IP65
GB 3836.1-2010GB 3836.2-2010
C = CCoE/PESO I = Segurança intrínseca
Ex ia IIC T4 Ga/GbTa = -50 °C a 71 °C IP65
IEC 60079-0:2011IEC 60079-11:2011Regras de petróleo 2002
F = À prova de chamas
Ex db IIB+H2 T6 a T3 Ga/GbTa = -40 °C a 71 °C IP65
IEC 60079-0:2007-10IEC 60079-1:2007-04IEC 60079-26:2014-10IEC 60529:2013Regras de petróleo 2002
T = CML/TIIS I = Segurança intrínseca
Ex ia IIC T4 Ga/GbTa = -50 °C a 71 °C IP65
IEC 60079-0:2011IEC 60079-11:2011
F = À prova de chamas
Ex db IIB+H2 T6 a T3 Ga/GbTa = -40 °C a 71 °C IP65
IEC 60079-0:2007-10IEC 60079-1:2007-04IEC 60079-26:2014-10IEC 60529:2013
K = KC I = Segurança intrínseca PENDENTE PENDENTE
F = À prova de chamas PENDENTE PENDENTE
Level Plus® CHAMBEREDManual de operação
I 21 I
13.2 Certificados
É possível baixar as cópias de todos os certificados que estão localizados em www.mtssensors.com. e também na página inicial específica do produto. Se tiver problemas para obter o certificado na, entre em contato com o suporte técnico da MTS e eles serão enviados eletronicamente.
13.3 FM (NEC)
13.3.1 Intrinsecamente seguro
13.3.1.1 Condições especificas de uso seguro 1. O gabinete do aparelho contém alumínio e é considerado
um risco potencial de incêndio por impacto ou atrito. Tome cuidado durante a instalação e evitar o impacto ou o atrito. (Quando instalado em uma aprovação Ga).
2. A temperatura ambiente máxima permitida do transmissor de nível digital/analógica Level Plus é de 71 °C. Para evitar os efeitos da temperatura do processo e outros efeitos térmicos, tome cuidado para assegurar que o ambiente ao redor e dentro do invólucro do transmissor não exceda 71 °C.
3. Alguns modelos contêm um gabinete com partes não metálicas para evitar o risco de faíscas por eletrostática, a superfície não metálica deve ser limpa somente com um pano úmido.
13.3.1.2 Etiquetas
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES
0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE 551629-1 B
1 2
DRAWN BY: NJ
A NJ
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
INTRINSICALLY SAFECL. I, Div. 1, GR. ABCDCL. I, Zone 0/1, AEx ia IIC T4Ta = -50°C to +71°C ; IP65when connected in accordance with FM approved installa on drawing # 651543-1
WARNING: REFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGS
Model No: Serial No: Date :
MTS Systems CorporationSensors Division3001 Sheldon Dr.Cary, NC 27513
Level Plus Transmitter
USE MTS LOGO ARTWORK
10 POINT SIZE
8 POINT TEXT SIZE
4.5 POINT TEXT SIZE
MTS TO PRINTMODEL NO.SERIAL NO.
DATE CODE.
ENTITY PARAMETERS:SEE PRINT REFERENCE CHART
4.5 POINT TEXT SIZE
FM APPROVED
USE FM LOGO ARTWORK
US
LEVEL
1:1
7570 RELEASE TO PRODUCTION
(ACP) LABEL, LP, IS US - DIGITAL
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES.3. MATERIAL: 3M 7883 METALLIZED POLYESTER FOIL W/GAS RESISTANT INK.
P/N 551629-1 Rev B
10/24/14
86.30 [3.40]
1.78 [.07]
34.69 [1.37]
1.78 [.07]
69.85 [2.75]
R3.30 [.13]
28.70 [1.13]
15.80 [.62]
12/02/14NJB 7847 IP RATING WAS 66
®
Fig. 14: Etiqueta FM intrinsecamente segura, invólucro Modbus ou DDA, NEMA
Fig. 15: Etiqueta FM intrinsecamente segura, HART®, invólucro NEMA
Fig. 16: Etiqueta FM intrinsecamente segura, Modbus ou DDA, invólucro com cavidade única ou dupla
Fig. 17: Etiqueta FM intrinsecamente segura, HART®, invólucro com cavidade única ou dupla
1
1
2
2
A A
B B
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE: SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551642- C
1 1
DRAWN BY: NJ
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
INTRINSICALLY SAFECL. I, Div. 1, GR. ABCDCL. I, Zone 0/1, AEx ia IIC T4Ta = -50°C TO +71°C ; IP65WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETYREFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGS
INSTALL PER DRAWING # 651544-1SUPPLY VOLTAGE: 28 VDC
Level Plus Transmitter
35.05 [1.38]
"L1"∆ "L2"
17.53 [.69]
7.5 POINT SIZEMTS TO PRINTMODEL NO.
SERIAL NO./DATE CODE
"D1"
4.0 POINT TEXT SIZE(TYP.)
8.97 [.35] 3.47 [.1
(ACP) LABEL, LP, IS US - ANALOG
FM LOGO ARTWORK4.5 POINT TEXT SIZE
R
FM
USE MTS LOGO ARTWORK14.0 POINT SIZE
LEVEL
1:1
APPROVED
P/N 551642-X Rev C
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. MATERIAL TO BE SCREEN PRINTED ALUMINUM WITH SATIN BACKGROUND AND BLACK TEXT OR LASER ETCHED ALUMINUM.3. ∆ INDICATES CRITICAL DIMENSIONS.4. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES5. MATERIAL: .8 [.03] THICK ALUMINUM6. REFER TO TABLE 1 FOR "L1" & "L2" DIMENSIONS.
SEE TABLE 1 FOR DASH #.
TABLE 1DASH
# HOUSING "L1" "L2" "D1"
-1 ADALET85.85 [3.38]
69.85 [2.75]
Ø2.35 [.09]x2
-2LIMATHE
RM65 [2.56]
58 [2.28]
Ø 3.05 [.12] x2
C 8256 ADDED "D1" MS 2/22/17B 7847 IP RATING WAS 66 NJ 12/2/14A 7570 RELEASE FOR PRODUCTION NJ 10/24/14
REV ECO# DESCRIPTION BY DATE
1
1
2
2
A A
B B
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE: SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551634- C
1 1DRAWN BY: NJ
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
INTRINSICALLY SAFECL. I, Div. 1, GR. ABCDCL. I, Zone 0/1, AEx ia IIC T4Ta = -50°C TO +71°C ; IP65WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETYREFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGS
INSTALL PER DRAWING # 651543-1SUPPLY VOLTAGE: 28 VDC
Level Plus Transmitter
35.05 [1.38]
"L1"∆ "L2"
17.53 [.69]
7.5 POINT SIZEMTS TO PRINTMODEL NO.
SERIAL NO./DATE CODE
"D1"
4.0 POINT TEXT SIZE(TYP.)
8.97 [.35] 3.47 [.14]
(ACP) LABEL, LP, IS US - DIGITAL
FM LOGO ARTWORK4.5 POINT TEXT SIZE
R
FM
USE MTS LOGO ARTWORK14.0 POINT SIZE
LEVEL
1:1
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. MATERIAL TO BE SCREEN PRINTED ALUMINUM WITH SATIN BACKGROUND AND BLACK TEXT OR LASER ETCHED ALUMINUM.3. ∆ INDICATES CRITICAL DIMENSIONS.4. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES.5. MATERIAL: .8 [0.03] THICK ALUMINUM6. REFER TO TABLE 1 FOR "L1" & "L2" DIMENSIONS.
APPROVED
P/N 551634-X Rev C
SEE TABLE 1 FOR DASH #.
TABLE 1DASH
# HOUSING "L1" "L2" "D1"
-1 ADALET85.85[3.38]
69.85 [2.75]
Ø2.35 [.09]x2
-2 LIMATHERM65
[2.56]58
[2.28]Ø 3.05 [.12] x2
C 8256 ADDED "D1" MS 2/22/1766 SAW GNITAR PI7487B NJ 12/2/14
A 7570 RELEASE FOR PRODUCTION NJ 10/24/14ETADYBNOITPIRCSED#OCEVER
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES
0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE 551629-1 B
1 2
DRAWN BY: NJ
A NJ
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
INTRINSICALLY SAFECL. I, Div. 1, GR. ABCDCL. I, Zone 0/1, AEx ia IIC T4Ta = -50°C to +71°C ; IP65when connected in accordance with FM approved installa on drawing # 651543-1
WARNING: REFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGS
Model No: Serial No: Date :
MTS Systems CorporationSensors Division3001 Sheldon Dr.Cary, NC 27513
Level Plus Transmitter
USE MTS LOGO ARTWORK
10 POINT SIZE
8 POINT TEXT SIZE
4.5 POINT TEXT SIZE
MTS TO PRINTMODEL NO.SERIAL NO.
DATE CODE.
ENTITY PARAMETERS:SEE PRINT REFERENCE CHART
4.5 POINT TEXT SIZE
FM APPROVED
USE FM LOGO ARTWORK
US
LEVEL
1:1
7570 RELEASE TO PRODUCTION
(ACP) LABEL, LP, IS US - DIGITAL
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES.3. MATERIAL: 3M 7883 METALLIZED POLYESTER FOIL W/GAS RESISTANT INK.
P/N 551629-1 Rev B
10/24/14
86.30 [3.40]
1.78 [.07]
34.69 [1.37]
1.78 [.07]
69.85 [2.75]
R3.30 [.13]
28.70 [1.13]
15.80 [.62]
12/02/14NJB 7847 IP RATING WAS 66
®
651544-1
551641-1
Level Plus® CHAMBEREDManual de operação
I 22 I
13.3.1.3 Diagrama de instalação
Fig. 18: Diagrama de instalação FM intrinsecamente segura, Modbus e DDA, Página 1
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651543-1
1 2
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
24 VDC
COMM
ON- >
Rx /Tx+
Rx /Tx-
GROUND
EARTH GROUND(SEE NOTE 4)
EARTH GROUND(SEE NOTE 4)
Rx/Tx-
Rx/Tx+
GND
+24V
SAFETY BARRIER SAFETY BARRIER
SAFETY BARRIER
NO
TES:1.ALL N
ATION
AL AND
LOC
AL CO
DES AN
D R
EGU
LATION
S MU
ST BE ADH
ERED
TO W
HEN
INSTALLIN
G TH
E LEVEL SENSO
R IN
HAZAR
DO
US EN
VIRO
NM
ENTS.
SEAL ALL CO
ND
UITS W
ITHIN
457 MM
(18"). 2.LO
OP C
ABLE MU
ST BE 24 AWG
TO 14 AW
G (.511M
M² to 1.6M
M²)
SHIELD
ED TW
ISTED PAIR
CABLE W
ITH SH
IELD. C
ABLE CAPAC
ITANC
E MU
ST BE LESS TH
AN 30 pF PER
FOO
T (98 pF PER M
). CABLE SH
IELD IS C
ON
NEC
TED TO
SYSTEM G
RO
UN
D IN
NO
N-H
AZARD
OU
S AREA. SEE IN
STALLATION
MAN
UAL FO
R
ADD
ITION
AL CABLE IN
FOR
MATIO
N.
3.THE R
ESISTANC
E BETWEEN
EARTH
GR
OU
ND
AND
THE IN
TRIN
SICALLY SAFE G
RO
UN
D M
UST BE LESS TH
AN 1 O
HM
. 4.TH
E TRAN
SDU
CER
FRAM
E SHALL BE G
RO
UN
DED
TO EAR
TH G
RO
UN
D D
IREC
TLY OR
THR
OU
GH
THE EQ
UIPM
ENT O
N W
HIC
H IT IS M
OU
NTED
. 5. C
ON
TRO
L EQU
IPMEN
T CO
NN
ECTED
TO ASSO
CIATED
APPARATU
S MU
ST N
OT U
SE OR
GEN
ERATE M
OR
E THAN
250 VRM
S OR
VDC
6.ASSOC
IATED APPAR
ATUS M
ANU
FACTU
RER
'S INSTALLATIO
N D
RAW
ING
MU
ST BE FO
LLOW
ED W
HEN
INSTALLIN
G TH
IS EQU
IPMEN
T. 7.O
NLY U
SE NEC
(e.g FM) APPR
OVED
BARR
IERS.
8.ENTITY PAR
AMETER
S: SU
PPLY: Rx/Tx-: R
x/Tx+: U
i = 28VDC
Ui= 8.6V U
i= 8.6V Ii = 100m
A Ii = 10mA Ii = 10m
A C
i = 0 µF Ci = 0 µF C
i = 0 µF Li = 0 µH
Li = 0 µH Li = 0 µH
Pi = 0.7 W Pi= 0.0215 W
P i= 0.0215 W 9.TH
E ENTITY C
ON
CEPT ALLO
WS IN
TERC
ON
NEC
TION
OF IN
TRIN
SICALLY SAFE APPAR
ATUS
WITH
ASSOC
IATED APPAR
ATUS W
HEN
THE FO
LLOW
ING
IS TRU
E: Vm
ax or Ui ≥ Voc, Vt or U
o; Im
ax or Ii ≥ Isc, It or Io; Pm
ax or Pi ≥ Po; C
a ≥ Ci + C
cable; La ≥ Li + Lcable. 10.D
UAL-C
AVITY ENC
LOSU
RES:
CU
STOM
ER C
ON
NEC
TION
S WILL BE M
ADE AT TER
MIN
AL BLOC
K ON
POW
ER SID
E O
F HO
USIN
G (N
OT TO
TERM
INAL BLO
CK O
N IN
TERC
ON
NEC
T BOAR
D).
11.INSTALLATIO
N SH
OU
LD BE IN
ACC
OR
DAN
CE W
ITH AN
SI/ISA RP12.06.01 "IN
STALLATION
OF
INTR
INSIC
ALLY SAFE SYSTEMS FO
R H
AZARD
OU
S (CLASSIFIED
) LOC
ATION
S" AN
D TH
E NATIO
NAL ELEC
TRIC
AL CO
DE (AN
SI/NFPA 70).
12.THE M
AXIMU
M PER
MITTED
AMBIEN
T TEMPER
ATUR
E OF TH
E LEVEL PLUS D
IGITAL/AN
ALOG
LEVEL TR
ANSM
ITTER IS 71 °C
. TO AVO
ID TH
E EFFECTS O
F PRO
CESS TEM
PERATU
RE AN
D
OTH
ER TH
ERM
AL EFFECTS C
ARE SH
ALL BE TAKEN TO
ENSU
RE TH
E SUR
RO
UN
DIN
G AM
BIENT
AND
THE AM
BIENT IN
SIDE TH
E TRAN
SMITTER
HO
USIN
G D
OES N
OT EXC
EED 71°C
13.CAU
TION
: FLEXIBLE GAU
GES H
AVE A MIN
IMU
M BEN
D R
ADIU
S OF 381M
M(15")
14.WAR
NIN
G: TH
E APPARATU
S ENC
LOSU
RE C
ON
TAINS ALU
MIN
UM
AND
IS CO
NSID
ERED
TO C
ON
STITUTE A PO
TENTIAL R
ISK OF IG
NITIO
N BY IM
PACT O
R FR
ICTIO
N. C
ARE M
UST BE TAKEN
IN
TO AC
CO
UN
T DU
RIN
G IN
STALLATION
AND
USE TO
PREVEN
T IMPAC
T OR
FRIC
TION
15.WAR
NIN
G: SU
BSTITUTIO
N O
F CO
MPO
NEN
TS MAY IM
PAIR IN
TRIN
SIC SAFETY.
16.WAR
NIN
G: TO
PREVEN
T IGN
ITION
OF FLAM
MABLE O
R C
OM
BUSTIBLE ATM
OSPH
ERES,
DISC
ON
NEC
T POW
ER BEFO
RE SER
VICIN
G
17.WAR
NIN
G: TH
E EQU
IPMEN
T CO
NTAIN
S NO
N-M
ETALLIC EN
CLO
SUR
E PARTS, TO
PREVEN
T TH
E RISK O
F ELECTR
OSTATIC
SPARKIN
G. TH
E NO
N-M
ETALLIC SU
RFAC
E SHO
ULD
ON
LY BE C
LEANED
WITH
A DAM
P CLO
TH.
NON HAZARDOUS LOCATIONHAZARDOUS LOCATION
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(US). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
EARTH TERMINAL
(ACP) INSTALLATIN DWG LP DIGITAL
INTRINSICALLY SAFE FOR US
LEVEL
FM
APPROVED US
N/A
INTRINSICALLY SAFECL. I, DIV. 1, GR. ABCDCL. I Zone 0/1 AEx ia IIC T4 Ta =
-50 to 71°C ; IP65
Level Plus® CHAMBEREDManual de operação
I 23 I
Fig. 19: Diagrama de instalação FM intrinsecamente segura, Modbus e DDA, Página 2
DETAIL ASCALE 1.60 : 1
DETAIL CSCALE 3 : 1
DETAIL DSCALE 1.2
DETAIL ESCALE 1 : 1
A
C
D
E
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651543-1
2 2
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
+24V GNDEARTHTX/RX+TX/RX-
GND+24V
TX/RX-TX/RX+EARTH
GND+24V
TX/RX-
TX/RX+
EARTH
FIGU
RE 1
SING
LE CAVITY & N
EMA H
OU
SING
FIGU
RE 2
DU
AL CAVITY H
OU
SING
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: C
ON
DU
IT SEALS REQ
UIR
ED W
ITHIN
457 MM
(18") OF H
OU
SING
.
(ACP) INSTALLATIN DWG LP DIGITAL
INTRINSICALLY SAFE FOR US
+24V GND EARTH Tx/Rx+ Tx/Rx-
WIRE COLOR
SIGNALRED
24 V PWR
BLACK 0 V PW
RBLUE
N/AW
HITERX TX +
GREENRX TX -
DRAIN WIRE
EARTH GROUND
WIRING CHART (FOR NEM
A GAUGE)
PIN #SIGNAL
PIN 124 V PW
RPIN 2
0 V PWR
PIN 3N/A
PIN 4RX TX+
PIN 5RX TX-
PIN 6EARTH GROUND
PIN WIRING CHART (FOR NEM
A GAUGE)
LEVEL
Level Plus® CHAMBEREDManual de operação
I 24 I
Fig. 20: Diagrama de instalação FM intrinsecamente segura, HART®, Página 1
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651544-1LEVEL
1 2
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
NO
N H
AZARD
OU
S LOC
ATION
HAZAR
DO
US LO
CATIO
N
NO
TES: 1. ALL N
ATION
AL AND
LOC
AL CO
DES AN
D R
EGU
LATION
S MU
ST BE ADH
ERED
TO W
HEN
INSTALLIN
G TH
E MTS LP SEN
SOR
IN H
AZARD
OU
S ENVIR
ON
MEN
TS. SEAL ALL C
ON
DU
ITS WITH
IN 457 M
M (18").
2. LOO
P CABLE M
UST BE 24 AW
G TO
14 AWG
(.511MM
² to 1.6MM
²) SH
IELDED
TWISTED
PAIR C
ABLE WITH
SHIELD
. CABLE C
APACITAN
CE M
UST
BE LESS THAN
30 pF PER FO
OT (98 pF PER
m). C
ABLE SH
IELD IS C
ON
NEC
TED TO
SYSTEM G
RO
UN
D IN
NO
N-H
AZARD
OU
S AREA. SEE IN
STALLATION
MAN
UAL FO
R
ADD
ITION
AL CABLE IN
FOR
MATIO
N.
3. THE R
ESISTANC
E BETWEEN
EARTH
GR
OU
ND
AND
THE IN
TRIN
SICALLY SAFE G
RO
UN
D M
UST BE LESS TH
AN 1 O
HM
. 4. TH
E TRAN
SDU
CER
FRAM
E SHALL BE G
RO
UN
DED
TO EAR
TH G
RO
UN
D D
IREC
TLY OR
THR
OU
GH
THE EQ
UIPM
ENT O
N W
HIC
H IT IS M
OU
NTED
. 5. C
ON
TRO
L EQU
IPMEN
T CO
NN
ECTED
TO ASSO
CIATED
APPARATU
S MU
ST N
OT U
SE OR
GEN
ERATE M
OR
E THAN
250 VRM
S OR
VDC.
6. ASSOC
IATED APPAR
ATUS M
ANU
FACTU
RER
'S INSTALLATIO
N D
RAW
ING
MU
ST BE FO
LLOW
ED W
HEN
INSTALLIN
G TH
IS EQU
IPMEN
T 7. O
NLY U
SE NEC
(e.g FM) APPR
OVED
BARR
IERS.
8. APPRO
VED LO
OP SEPAR
ATION
METH
OD
S: *R
UN
LOO
PS IN SEPAR
ATE CABLES
*RU
N LO
OPS IN
SEPARATE G
RO
UN
DED
SHIELD
S 9. EN
TITY PARAM
ETERS EAC
H LO
OP:
Ui = 28 VD
C Ii = 120 m
A C
i = 0 µF Li = 5 µH Pi = 840 m
W 10. D
UAL-C
AVITY ENC
LOSU
RES:
CU
STOM
ER C
ON
NEC
TION
S WILL BE M
ADE AT TER
MIN
AL BLOC
K ON
POW
ER SID
E O
F HO
USIN
G (N
OT TO
TERM
INAL BLO
CK O
N IN
TERC
ON
NEC
T BOAR
D)
11 INSTALLATIO
N SH
OU
LD BE IN
ACC
OR
DAN
CE W
ITH AN
SI/ISA RP12.06.01 "IN
STALLATION
OF
INTR
INSIC
ALLY SAFE SYSTEMS FO
R H
AZARD
OU
S (CLASSIFIE
D) LO
CATIO
NS"
AND
THE N
ATION
AL ELECTR
ICAL C
OD
E (ANSI/N
FPA 70). 12.TH
E MAXIM
UM
PERM
ITTED AM
BIENT TEM
PERATU
RE O
F THE LEVEL PLU
S DIG
ITAL/ANALO
G
LEVEL TRAN
SMITTER
IS 71 °C. TO
AVOID
THE EFFEC
TS OF PR
OC
ESS TEMPER
ATUR
E AND
O
THER
THER
MAL EFFEC
TS CAR
E SHALL BE TAKEN
TO EN
SUR
E THE SU
RR
OU
ND
ING
AMBIEN
T AN
D TH
E AMBIEN
T INSID
E THE TR
ANSM
ITTER H
OU
SING
DO
ES NO
T EXCEED
71°C 13.C
AUTIO
N: FLEXI BLE G
AUG
ES HAVE A M
INIM
UM
BEND
RAD
IUS O
F 381MM
(15") 14. W
ARN
ING
: THE APPAR
ATUS EN
CLO
SUR
E CO
NTAIN
S ALUM
INU
M AN
D IS C
ON
SIDER
ED TO
CO
NSTITU
TE A POTEN
TIAL RISK O
F IGN
ITION
BY IMPAC
T OR
FRIC
TION
. CAR
E MU
ST BE TAKEN
INTO
ACC
OU
NT D
UR
ING
INSTALLATIO
N AN
D U
SE TO PR
EVENT IM
PACT O
R FR
ICTIO
N 15.W
ARN
ING
: SUBSTITU
TION
OF C
OM
PON
ENTS M
AY IMPAIR
INTR
INSIC
SAFETY. 16.W
ARN
ING
: TO PR
EVENT IG
NITIO
N O
F FLAMM
ABLE O
R C
OM
BUSTIBLE ATM
OSPH
ERES.
DISC
ON
NEC
T POW
ER BEFO
RE SER
VICIN
G.
17.WAR
NIN
G: TH
E EQU
IPMEN
T CO
NTAIN
S NO
N-M
ETALLIC EN
CLO
SUR
E PARTS, TO
PREVEN
T TH
E RISK O
F ELECTR
OSTATIC
SPARKIN
G. TH
E NO
N-M
ETALLIC SU
RFAC
E SHO
ULD
ON
LY BE C
LEANED
WITH
A DAM
P CLO
TH.
EARTH
GR
OU
ND
LUG
NO
TE 3
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(US). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
24 VDC
CO
NTR
OL
INPU
T 1
CO
NTR
OL
INPU
T 2
APPRO
VED SAFETY
BARR
IER
APPRO
VED SAFETY
BARR
IER
LOO
P VOLTAG
E
SHIELD
SHIELD
LOO
P 1+
LOO
P 1-
LOO
P 2+
LOO
P 2-
FM
APPROVED US
(ACP) INSTALLATIN DWG LP ANALOG
INTRINSICALLY SAFE FOR US
SING
LE OR
DU
AL CAVITY
NEM
A HO
USIN
G
F
INTRINSICALLY SAFECL. I, DIV. 1, GR. ABCDCL. I Zone 0/1 AEx ia IIC T4 Ta =
-50 to 71°C ; IP65
EARTH
GR
OU
ND
(SEE NO
TE 4)
EARTH
GR
OU
ND
(SEE NO
TE 4)
Level Plus® CHAMBEREDManual de operação
I 25 I
Fig. 21: Diagrama de instalação FM intrinsecamente segura, HART®, Página 2
DETAIL D
SCALE 3
DETAIL E
SCALE 1.60
DETAIL F
SCALE 1.2
DETAIL H
SCALE 1 : 1
D
E
F
H
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651544-1LEVEL
2 2
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
LOOP 2-
LOOP 2+
EARTH
LOOP 1-
LOOP 1+
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: C
ON
DU
IT SEALS REQ
UIR
ED W
ITHIN
457 MM
(18") OF H
OU
SING
.
FIGU
RE 2
DU
AL CAVITY H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
FIGU
RE 1
SING
LE CAVITY & N
EMA H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
(ACP) IN
STALLATION
DW
G LP AN
ALGO
IN
TRIN
SICALLY SAFE ATEX/IEC
E
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
F
PIN #SIGNAL
PIN 1LOOP 1-
PIN 2LOOP 1+
PIN 3LOOP 2-
PIN 4LOOP 2+
PIN 5N/A
PIN 6EARTH GROUND
WIRE COLOR
SIGNALRED
LOOP 1+BLACK
LOOP 1-BLUE
LOOP 2-W
HITELOOP 2+
GREENN/A
DRAIN WIRE
EARTH GROUND
PIN WIRING CHART (FOR NEM
A GAUGE)
WIRING CHART(FOR NEM
A GAUGE)
Level Plus® CHAMBEREDManual de operação
I 26 I
13.3.2 À prova de explosão / à prova de chamas
13.3.2.1 Condições especificas de uso seguro
1. Aviso: O equipamento contém um gabinete com partes não metálicas e parte de processo para evitar o risco de faíscas por eletrostática, a superfície não metálica deve ser limpa somente com um pano úmido.A superfície pintada do equipamento pode armazenar descarga eletrostática e tornar-se uma fonte de ignição em aplicações com umidade relativa baixa (<~30%) em que a superfície pintada é relativamente livre de contaminação da superfície como sujeiras, poeira ou óleo. A limpeza da superfície pintada deve ser feita apenas com um pano úmido.
2. Os cabos devem ter a classificação > 5 °C acima da temperatura ambiente máxima.
3. Para manter a classificação de proteção contra entrada do IP65, a fita Teflon™ (3 voltas) ou cola para canos deve ser usada. Consulte as instruções de instalação.
4. O equipamento pode ser instalado na parede entre uma área Zona 0 e uma área Zona 1 menos perigosa. Nessa configuração, a conexão do processo está instalada em uma área Zona 0 e o invólucro do transmissor está em uma área Zona 1. Consulte as instruções de instalação.
5. Os medidores flexíveis têm um raio de curvatura mínimo de 381 mm (15 pol.).
6. Caminho da chama não para reparo. 7. A classe de temperatura aplicável, faixa de temperatura de
processo e a faixa de temperatura ambiente do equipamento estão abaixo: • T3 com a faixa de temperatura de processo −40 °C a +150 °C • T4 com a faixa de temperatura de processo −40 °C a +135 °C• T5 com a faixa de temperatura de processo −40 °C a +100 °C• T6 com a faixa de temperatura de processo −40 °C a +85 °C
A faixa de temperatura ambiente é de −40 °C≤Ta≤71 °C 8. Quando montar em um MLG (medidor magnético de nível),
certifique-se o cabeçote eletrônico e a barreira de pressão têm um espaçamento mínimo de 5 pol. Consulte o Manual de instalação para detalhes.
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551474- A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 7/28/16
Level Plus Transmitter
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
FM16US0242X
EXPLOSION PROOF FOR CL. I, DIV. 1, GR BCD T6...T3.
(B, C, D)
CL. I, ZONE 0/1, AEx db IIB+H2 T6...T3 Ga/GbTa = -40°C TO +71°C ; IP 65INPUT: 28V (120mA) maxOUTPUT: RS485 WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. FOR ZONE INSTALLATIONS, A SEAL SHALL BE INSTALLED WITHIN 50mm OF THE ENCLOSURE. FOR DIVISION INSTALLATIONS A SEAL SHALL BE INSTALLED WITHIN 18 INCHESOF THE ENCLOSURE
INSTALL PER # 651552-1MAX. PRESSURE 1000 PSI (RIGID SENSOR)
MAX. PRESSURE 435 PSI (FLEX SENSOR)
7957 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP US - DIGITAL
FM
LEVEL
1:1
APPROVED
P/N 551474-1 Rev A
R
!
Fig. 22: À prova de explosão, etiqueta FM, Modbus ou DDA, opções de invólucro G, H ou L
Fig. 23: À prova de explosão, etiqueta FM, Modbus ou DDA, opções de invólucro D, E
Fig. 24: À prova de explosão, etiqueta FM, HART®, opções de invólucro G, H ou L
Fig. 25: À prova de explosão, etiqueta FM, HART®, opções de invólucro D, E
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551474- A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 7/28/16
Level Plus Transmitter
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
FM16US0242X
EXPLOSION PROOF FOR CL. I, DIV. 1, GR. CL. I, ZONE 0/1, AEx db IIB+H2 T6...T3 Ga/GbTa = -40
ABCD T6...T3
°C TO +71°C ; IP 65INPUT: 28V (120mA) maxOUTPUT: RS485 WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. FOR ZONE INSTALLATIONS, A SEAL SHALL BE INSTALLED WITHIN 50mm OF THE ENCLOSURE. FOR DIVISION INSTALLATIONS A SEAL SHALL BE INSTALLED WITHIN 18 INCHESOF THE ENCLOSURE
INSTALL PER # 651552-1MAX. PRESSURE 1000 PSI (RIGID SENSOR)
MAX. PRESSURE 435 PSI (FLEX SENSOR)
7957 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP US - DIGITAL
FM
LEVEL
1:1
APPROVED
P/N 551474-2 Rev A
R
!
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551495- A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 7/28/16
Level Plus TransmitterFM16US0242X
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
EXPLOSION PROOF FOR CL. I, DIV. 1, GR.
(A, B, C, D)
BCD T6...T3CL. I, ZONE 0/1, AEx db IIB+H2 T6...T3 Ga/GbTa = -40°C TO +71°C ; IP 65INPUT: 28V (120mA) maxOUTPUT: 4-20mA WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. FOR ZONE INSTALLATIONS, A SEAL SHALL BE INSTALLED WITHIN 50mm OF THE ENCLOSURE. FOR DIVISION INSTALLATIONS A SEAL SHALL BE INSTALLED WITHIN 18 INCHESOF THE ENCLOSURE
INSTALL PER # 651553-1MAX. PRESSURE 1000 PSI (RIGID SENSOR)MAX. PRESSURE 435 PSI (FLEX SENSOR)
7957 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP US - ANALOG
FM
LEVEL
1:1
APPROVED
P/N 551495-1 Rev A
R
!
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551495- A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 7/28/16
Level Plus TransmitterFM16US0242X
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
EXPLOSION PROOF FOR CL. I, DIV. 1, GR.
(A, B, C, D)
BCD T6...T3CL. I, ZONE 0/1, AEx db IIB+H2 T6...T3 Ga/GbTa = -40°C TO +71°C ; IP 65INPUT: 28V (120mA) maxOUTPUT: 4-20mA WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. FOR ZONE INSTALLATIONS, A SEAL SHALL BE INSTALLED WITHIN 50mm OF THE ENCLOSURE. FOR DIVISION INSTALLATIONS A SEAL SHALL BE INSTALLED WITHIN 18 INCHESOF THE ENCLOSURE
INSTALL PER # 651553-1MAX. PRESSURE 1000 PSI (RIGID SENSOR)MAX. PRESSURE 435 PSI (FLEX SENSOR)
7957 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP US - ANALOG
FM
LEVEL
1:1
APPROVED
P/N 551495-1 Rev A
R
!
13.3.2.2 Etiquetas
Level Plus® CHAMBEREDManual de operação
I 27 I
13.3.2.3 Diagrama de instalação
Fig. 26: À prova de explosão, diagrama de instalação FM, Modbus e DDA, Página 1
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651553-1B
LEVEL1
2 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***B
MS
10/22/15RELEASE TO PRODUCTION
8482UPDATED W
IRING DWG TO ANALOG
MS
5/17/18A
7957
EARTH GROUND
LOOP 2-
LOOP 2+
EARTH GROUND
LOOP 1-
LOOP 1+
ZONE 1
ZONE 0SEE NOTE 8
EARTH
GR
OU
ND
LUG
NO
TE 3
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(US). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
FM
APPROVED
(ACP) INSTALLATIN DWG LP ANALOG
EXPLOSION PROOF US
SING
LE OR
DU
AL CAVITY
FM US- FM
16US0242XEXPLOSION PROOFCL. I, DIV. 1, GR. ABCD T6...T3CL. I, DIV. 1, GR. BCD T6...T3CL. 1, ZN. 0/1, AEx db IIB+H2 T6...T3 Ga/GbTa =
-40°C to +71°C ; IP65
HAZARDOUS LOCATIONNON HAZARDOUS LOCATION
CO
ND
UIT SEAL
CO
ND
UIT
SEE NO
TE 1
CO
ND
UIT SEAL
5" [127mm
] Minim
um
NO
TES:1.ALL N
ATION
AL AND
LOC
AL CO
DES AN
D R
EGU
LATION
S MU
ST BE ADH
ERED
TO W
HEN
INSTALLIN
G TH
E LEVEL SENSO
R IN
HAZAR
DO
US EN
VIRO
NM
ENTS.
FOR
ZON
E INSTALLATIO
NS, A SEAL SH
ALL BE INSTALLED
WITH
IN 50m
m O
F THE
ENC
LOSU
RE. FO
R D
IVISION
INSTALLATIO
NS, A SEAL SH
ALL BE INSTALLED
WITH
IN 18 IN
CH
ES OF TH
E ENC
LOSU
RE.
2.DU
AL-CAVITY EN
CLO
SUR
ES: C
USTO
MER
CO
NN
ECTIO
NS W
ILL BE MAD
E AT TERM
INAL BLO
CK O
N PO
WER
SIDE
OF H
OU
SING
(NO
T TO TER
MIN
AL BLOC
K ON
INTER
CO
NN
ECT BO
ARD
). SEE FIGU
RE 2 O
N PAG
E 23. C
AUTIO
N: FLEXIBLE G
AUG
ES HAVE A M
INIM
UM
BEND
RAD
IUS O
F 381mm
(15")4.W
ARN
ING
: TO PR
EVENT IG
NITIO
N O
F FLAMM
ABLE OR
CO
MBU
STIBLE ATMO
SPHER
ES, D
ISCO
NN
ECT PO
WER
BEFOR
E SERVIC
ING
5.W
ARN
ING
: THE EQ
UIPM
ENT C
ON
TAINS N
ON
-METALLIC
ENC
LOSU
RE AN
D PR
OC
ESS PARTS, TO
PREVEN
T TH
E RISK O
F ELECTR
OSTATIC
SPARKIN
G. TH
E N ON
-METALLIC
SUR
FACE AN
D PR
OC
ESS PARTS SH
OU
LD O
NLY
BE CLEAN
ED W
ITH A D
AMP C
LOTH
. PAINTED SURFACE OF THE EQUIPMENT M
AY STORE ELECTROSTATIC CHARGE AND BECOM
E A SOURCE OF IGNITION IN APPLICATIONS WITH A LOW
RELATIVE HUMIDITY <
~30% RELATIVE
HUMIDITY W
HERE THE PAINTED SURFACE IS RELATIVELY FREE OF SURFACE CONTAMINATION
SUCH AS DIRT, DUST OR OIL. CLEANING OF THE PAINTED SURFACE SHOULD ONLY BE DONE W
ITH A DAMP CLOTH.
6. CABLES SH
ALL BE RATED
> 5C ABO
VE MAXIM
UM
AMBIEN
T TEMPER
ATUR
E. 7. TO
MAIN
TAIN TH
E ING
RESS PR
OTEC
TION
RATIN
G O
F IP65, TEFLON
TAPE (3 WR
APS) OR
PIPE DO
PE SHALL
BE USED
. REFER
TO IN
STALLATION
INSTR
UC
TION
S.8. TH
E EQU
IPMEN
T CAN
BE INSTALLED
IN TH
E BOU
ND
ARY W
ALL BETWEEN
A ZON
E 0 AREA AN
D TH
E LESS H
AZARD
OU
S AREA, ZO
NE 1. IN
THIS C
ON
FIGU
RATIO
N, TH
E PRO
CESS C
ON
NE C
TION
IS INSTALLED
IN
A ZON
E 0 AREA, W
HILE TH
E TRAN
SMITTER
HO
USIN
G IS IN
STALLED IN
A ZON
E 1 AREA.
9. THE APPLIC
ABLE TEMPER
ATUR
E CLASS O
F THE EQ
UIPM
ENT, AM
BIENT TEM
PERATU
RE R
ANG
E, AN
D M
AXIMU
M PR
OC
ESS TEMPER
ATUR
E OF TH
E EQU
IPMEN
T IS AS FOLLO
WS;
T3 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +150°C T4 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +135°C
T5 WITH
PRO
CESS TEM
PERAT U
RE R
ANG
E OF -40°C
to +100°C T6 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +85°C
AMBIEN
T TEMPER
ATUR
E RAN
GE -40°C Ta+71°C
10. WH
EN M
OU
NTIN
G O
N A M
AGN
ETIC LEVEL G
AUG
E MAKE SU
RE TH
E ELECTR
ON
IC H
EAD AN
D PR
ESSUR
E BAR
RIER
HAVE A M
INIM
UM
SPACIN
G O
F 5 INC
HES. SEE IN
STALLATION
MAN
UAL FO
R D
ETAIL11. FLAM
EPATHS AR
E NO
T FOR
REPAIR
Level Plus® CHAMBEREDManual de operação
I 28 I
Fig. 27: À prova de explosão, diagrama de instalação FM, Modbus e DDA, Página 2
DETAIL D
SCALE 3
DETAIL E
SCALE 1.60
DETAIL F
SCALE 1.2
D
E
F
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651553-1B
LEVEL2
2 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***B
MS
5/17/18RELEASE TO PRODUCTION
8482UPDATED W
IRING DWG TO ANALOG
MS
5/17/18A
7957
LOOP 2-
LOOP 2+
EARTH
LOOP 1-
LOOP 1+
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: FO
R ZO
NE IN
STALLATION
S, A SEAL SHALL BE IN
STALLED W
ITHIN
50mm
OF TH
E EN
CLO
SUR
E. FOR
DIVISIO
N IN
STALLATION
S, A SEAL SHALL BE IN
STALLED W
ITHIN
18 INC
HES O
F THE EN
CLO
SUR
E.
FIGU
RE 2
DU
AL CAVITY H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
FIGU
RE 1
SING
LE CAVITY H
OU
SING
(ACP) IN
STALLATION
DW
G LP AN
ALOG
IN
TRIN
SICALLY SAFE U
S
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
Level Plus® CHAMBEREDManual de operação
I 29 I
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
EC
O #
DESC
RIP
TION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LES
S OTH
ER
WISE
SPEC
IFIED
TOLER
ANC
ES0 P
LACE
SM
M1 PLA
CE
MM
AN
GLE
S
0.5
0.1
- THR
EA
D D
EP
THS
AR
E TO
MIN
. FULL TH
DS
- DR
ILL DE
PTH
S A
RE
TO FU
LL DIA
.- R
EM
OV
E B
UR
RS
AN
D S
HA
RP
ED
GE
S- D
O N
OT S
CA
LE P
RIN
T- M
AC
HIN
ED
SU
RFA
CE
FINIS
H 3.2uM
[125 uIn]
PRO
PRIETA
RY D
ATA
THE
INFO
RM
ATIO
N A
ND
DE
SIG
N(S
) DIS
CLO
SE
DH
ER
EIN
AR
E TH
E P
RO
PE
RTY
OF M
TS S
YS
TEM
SC
OR
PO
RA
TION
AN
D M
AY
NO
T BE
US
ED
,R
EP
RO
DU
CE
D O
R D
ISC
LOS
ED
IN A
NY
FOR
ME
XC
EP
T AS
GR
AN
TED
IN W
RITIN
G B
Y M
TSS
YS
TEM
S C
OR
PO
RA
TION
. THIS
RE
STR
ICTIO
NE
XC
LUD
ES
INFO
RM
ATIO
N TH
AT IS
IN TH
E
PU
BLIC
DO
MA
IN O
R W
AS
LEG
ITIMA
TELY
IN TH
EP
RIO
R P
OS
SE
SS
ION
OF TH
E R
EC
IPIE
NT.
mM
TS SYS
TEMS
CO
RP
OR
ATIO
NS
ENSO
RS D
IVISIO
N3001 SH
ELDO
N D
RIVE
, CA
RY, N
C 27513
METRIC
FIRST
ANG
LED
651552-1A
1
2 D
RAW
N BY:
MS
***NO
RE
VISION
S SHALL BE
MA
DE
WITH
OU
T THE
NO
TIFICA
TION
TO A
PPRO
VAL AG
EN
CY(S).***
AM
S6/22/16
RELEASE TO PRO
DU
CTION
24 VDC
COM
MO
N-
Rx /Tx+
Rx /Tx-
EARTH G
ROU
ND
EARTH G
ROU
ND
ZON
E 1
ZON
E 0
SEE NO
TE 8
NO
N H
AZARDO
US LO
CATION
HAZARD
OU
S LOCATIO
N
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(US). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
EARTH TERM
INAL
(ACP) INSTALLATIO
N D
WG
LP DIG
ITAL EXPLO
SION
PROO
F US
7957
LEVEL
FM
APPROVED
N/A
EXPLOSIO
N PRO
OF
CL. I, DIV. 1, G
R. ABCD T6...T3
CL. I, DIV. 1, G
R. BCD T6...T3
CL. 1, ZN. 0/1, AEx db IIB+
H2 T6...T3 G
a/Gb
Ta = -40°C to +
71°C ; IP65
NO
TES:1.A
LL NATIO
NAL AN
D LO
CAL C
OD
ES AND
REG
ULATIO
NS M
UST BE AD
HER
ED TO
WH
EN IN
STALLING
THE LEVEL SEN
SOR
IN H
AZAR
DO
US EN
VIRO
NM
ENTS.
FOR
ZON
E INSTALLATIO
NS, A SEAL SH
ALL BE INSTALLED
WITH
IN 50m
m O
F THE
ENC
LOSU
RE
. FOR
DIVISIO
N IN
STALLA TION
S, A SEAL SHALL BE IN
STALLED W
ITHIN
18 INC
HES O
F THE EN
CLO
SUR
E.2.D
UAL-C
AVITY ENC
LOSU
RES:
CU
STOM
ER C
ON
NEC
TION
S WILL BE M
ADE AT TER
MIN
AL BLOC
K ON
POW
ER SID
E O
F HO
US
ING
(NO
T TO TER
MIN
AL BLO
CK O
N IN
TERC
ON
NEC
T BO
ARD
). SEE FIGU
RE 2 O
N PAG
E 23. C
AUTIO
N: FLEX
IBLE G
AUG
ES HAVE A M
INIM
UM
BEND
RAD
IUS O
F 381mm
(15")4.W
ARN
ING
: TO PR
EVENT IG
NITIO
N O
F FLAMM
ABLE OR
CO
MBU
STIBLE ATMO
SPHER
ES, D
ISCO
N NEC
T POW
ER BE
FOR
E SERVIC
ING
5.W
ARN
ING
: THE EQ
UIPM
ENT C
ON
TAINS
NO
N-M
ETALLIC E
NC
LOSU
RE
AND
PRO
CESS PAR
TS, TO PR
EVENT
THE R
ISK OF ELEC
TRO
STATIC SPAR
KING
. THE N
ON
-METALLIC
SUR
FAC
E AND
PRO
CES
S PARTS SH
OU
LD O
NLY
BE CLEAN
ED W
ITH A
DAM
P CLO
TH. PAIN
TED SU
RFACE OF TH
E EQU
IPMEN
T MAY STO
RE ELECTROSTATIC CH
ARG
E AN
D BECO
ME A SO
URCE O
F IGN
ITION
IN APPLICATIO
NS W
ITH A LO
W RELATIVE H
UM
IDITY <
~30%
RELATIVE H
UM
IDITY W
HERE TH
E PAINTED
SURFACE IS R
ELATIVELY FREE OF SU
RFACE CON
TAMIN
ATION
SUCH
AS DIRT, D
UST O
R OIL. CLEAN
ING
OF TH
E PAINTED
SURFACE SH
OU
LD O
NLY BE D
ON
E W
ITH A D
AMP CLO
TH.
6. CABLES SH
ALL BE RATED
> 5C ABO
VE MAXIM
UM
AMBIEN
T TEMPER
ATU
RE.
7. TO M
AINTAIN
THE IN
GR
ESS PR
OTEC
TION
RATIN
G O
F IP65, TEFLON
TAPE (3 WR
APS) OR
PIPE DO
PE SHALL
BE USED
. REFER
TO IN
STALLA
TION
INSTR
UC
TION
S.8. TH
E EQ
UIP
ME
NT C
AN BE IN
STALLED IN
THE BO
UN
DAR
Y WALL BETW
EEN A ZO
NE 0 A
REA AN
D TH
E LESS H
AZARD
OU
S AREA, ZO
NE 1. IN
THIS C
ON
FIGU
RATIO
N, TH
E PRO
CE
SS CO
NN
ECTIO
N IS IN
STALLED
IN
A ZON
E 0 AREA, W
HILE TH
E TR
ANS
MITTER
HO
US
ING
IS INSTALLED
IN A ZO
NE 1 AR
EA. 9. TH
E APPLIC
ABLE TEM
PERATU
RE C
LASS O
F THE
EQ
UIP
MEN
T, AM
BIEN
T TEMPER
ATUR
E RA
NG
E,
AND
MAX
IMU
M PR
OC
ESS TEM
PERATU
RE O
F THE EQ
UIPM
ENT IS AS FO
LLOW
S; T3 W
ITH P
RO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +150°C T4 W
ITH P
RO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +135°C T5 W
ITH P
RO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +100°C T6 W
ITH P
RO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +85°C AM
BIENT TEM
PERATU
RE
RAN
GE -40°C Ta+71°C
10. WH
EN M
OU
NTIN
G O
N A M
AG
NETIC
LEVEL G
AU
GE M
AKE S
UR
E TH
E ELEC
TRO
NIC
HEA
D AN
D PR
ESS
UR
E
BAR
RIE
R H
AVE
A MIN
IMU
M SP
AC
ING
OF 5 IN
CH
ES. S
EE IN
STALLATIO
N M
AN
UAL FO
R D
ETAIL
11. FLAM
EPA
THS A
RE N
OT FO
R R
EPA
IR
FM U
S- FM16U
S0242X
CON
DU
IT SEALCON
DU
IT
SEE NO
TE 1
CON
DU
IT SEAL
Fig. 28: À prova de explosão, diagrama de instalação FM, HART®, Página 1
Level Plus® CHAMBEREDManual de operação
I 30 I
DETAIL F
SCALE 1.60 : 1
DETAIL G
SCALE 3 : 1
DETAIL H
SCALE 1.2
F
G
H
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD D
EPTHS AR
E TO M
IN. FU
LL THD
S- D
RILL D
EPTHS AR
E TO FU
LL DIA.
- REM
OVE BU
RR
S AND
SHAR
P EDG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE FIN
ISH 3.2uM
[125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIGN
(S) DISC
LOSED
HER
EIN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RA TIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN AN
Y FOR
MEXC
EPT AS GR
ANTED
IN W
RITIN
G BY M
TSSYSTEM
S CO
RPO
RATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THAT IS IN
THE
PUBLIC
DO
MAIN
OR
WAS LEG
ITIMATELY IN
THE
PRIO
R PO
SSESSION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651552-1A
2
2 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***A
MS
10/24/14RELEASE TO
PROD
UCTIO
N
+24V GNDEARTHTX/RX+TX/RX-
GND
+24V
TX/RX-
TX/RX+
EARTH
FIGU
RE 1
SING
LE CAVITY
FIGU
RE 2
DU
AL CAVITY H
OU
SING
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: FO
R ZO
NE IN
STALLATION
S, A SEAL SHALL BE IN
STALLED W
ITHIN
50mm
OF TH
EEN
CLO
SUR
E. FOR
DIVISIO
N IN
STALLATION
S, A SEAL SHALL BE IN
STALLED W
ITHIN
18 INC
HES O
F THE EN
CLO
SUR
E.
(ACP) INSTALLATIO
N D
WG
LP DIG
ITAL EXPLO
SION
PROO
F U.S.A
+24V GND EARTH Tx/Rx+ Tx/Rx-
7957
Fig. 29: À prova de explosão, diagrama de instalação FM, HART®, Página 2
Level Plus® CHAMBEREDManual de operação
I 31 I
13.4 FMC (CEC)
13.4.1 Intrinsecamente seguro
13.4.1.1 Condições especificas de uso seguro 1. O gabinete do aparelho contém alumínio e é considerado
um risco potencial de incêndio por impacto ou atrito. Tome cuidado durante a instalação e evitar o impacto ou o atrito. (Quando instalado em uma aprovação Ga).
2. A temperatura ambiente máxima permitida do transmissor de nível digital/analógica Level Plus® é de 71 °C. Para evitar os efeitos da temperatura do processo e outros efeitos térmicos, tome cuidado para assegurar que o ambiente ao redor e dentro do invólucro do transmissor não exceda 71 °C.
3. Alguns modelos contêm um gabinete com partes não metálicas para evitar o risco de faíscas por eletrostática, a superfície não metálica deve ser limpa somente com um pano úmido.
13.4.1.2 Etiquetas
Fig. 30: Etiqueta FMC intrinsecamente segura, Modbus e DDA, invólucro NEMA
Fig. 31: Etiqueta FMC intrinsecamente segura, HART®, invólucro NEMA
Fig. 32: Etiqueta FMC intrinsecamente segura, Modbus e DDA, invólucro com cavidade única ou dupla
Fig. 33: Etiqueta FMC intrinsecamente segura, HART®, invólucro com cavidade única e dupla
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE 551629-2 D
LEVEL1 2
(ACP) LABEL, LP, IS CANADA-DIGITAL
DRAWN BY: NJ
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
C 8037 ADDED FRENCH TRANSLATION DR 10/12/15B 7847 IP RATING WAS 66 NJ 12/02/14
1:1
D 8183 ADDED CL I, ZONE0/1 MS 8/18/16
INTRINSICALLY SAFECL. I, Div. 1, GR. ABCD CL.I, ZONE 0/1, Ex ia IIC T4 Ta = -50°C to +71°C ; IP66
when connected in accordance with FM approved installation drawing # 651543-2lorsqu'il est connecté en conformité avec FM approuvé le plan d'installation # 651543-2
WARNING: REFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGSAVERTISSEMENT : se référer au schéma d'installation à la prudence / AVERTISSEMENTS
MTS Systems CorporationSensors Division3001 Sheldon Dr.Cary, NC 27513
Model No: Modèle No:
Serial No:Numéro de série:
Date:
R
8 POINT TEXT SIZE
MTS TO PRINTMODEL NO.SERIAL NO.
DATE CODE.
ENTITY PARAMETERS:SEE PRINT REFERENCE CHART
4.5 POINT TEXT SIZE
FM APPROVED
USE FM LOGO ARTWORK
C
Level Plus Transmitter
NOTES:
1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.
2. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES.
3. MATERIAL: 3M 7883 METALLIZED POLYESTER FOIL W/GAS RESISTANT
P/N: 551629-2 Rev D
®
1
1
2
2
A A
B B
ECO # DESCRIPTION
C 8037 ADDED FRENCH TRANSLATION DR 10/12/15
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
(ACP) LABEL, LP, IS CANADA-ANALOGMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
B 7847 IP RATING WAS 66 NJ 12/02/14
PRODUCT LINE
FIRST ANGLE
mANGLES
SIZE
LEVEL1:1 METRICSCALE:
DRAWN BY:
DWG NO.
1
DATEBY
2OF
D551641-2REV
SHEET
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
1 PLACEMM
0.1
0 PLACESMM
0.5
THE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
PROPRIETARY DATA TOLERANCESUNLESS OTHERWISE SPECIFIED TITLE
REV
D 8183 ADDED CL. I Zone 0/1 MS 8/8/16
WARNING: REFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGSAVERTISSEMENT : se référer au schéma d'installation à la prudence / AVERTISSEMENTS
INTRINSICALLY SAFECL. I, Div. 1, GR. ABCD CL.I Zone 0/1 Ex ia IIC T4 Ta = -50°C to +71°C ; IP65
when connected in accordance with FM approvedinstallation drawing # 651544-2 lorsqu'il est connecté en conformité avec FM approuvéedessin d'installation # 651544-2
MTS Systems CorporationSensors Division3001 Sheldon Dr.Cary, NC 27513
Model No: Modèle No:
Serial No:Numéro de série:
Date:
R
USE MTS LOGOARTWORK
10 POINT SIZE
8 POINT TEXT SIZE
4.5 POINT TEXT SIZE
MTS TO PRINTMODEL NO.SERIAL NO.DATE CODE
ENTITY PARAMETERS:SEE PRINT REFERENCE CHART
4.5 POINT TEXT SIZE
FM APPROVED
USE FM LOGO ARTWORK
C
Level Plus Transmitter
P/N: 551641-2 Rev D
NOTES:
1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.
2. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES.
3. MATERIAL: 3M 7883 METALLIZED POLYESTER FOIL W/GAS RESISTANT INK.
1.78 [.07]
1.78 [.07]
28.70 [1.13]
15.80 [.62]
34.69 [1.37]
86.30 [3.40]
69.85 [2.75]
R3.30 [.13]
®
1
1
2
2
A A
B B
551704-LEVEL
METRIC
(ACP) LABEL, LP, IS CANADA-ANALOGMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
FIRST ANGLE E- THREAD DEPTHS ARE TO MIN. FULL THDS
- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
mTHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
PROPRIETARY DATA
NJDRAWN BY:
REV
SHEET
DWG NO.
1:1 11 OF
TITLEUNLESS OTHERWISE SPECIFIED
ANGLES
SIZE
SCALE:PRODUCT LINE
1 PLACEMM
TOLERANCES0 PLACES
MM 0.1 0.5
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
MTS Systems Corp. Sensors Division3001 Sheldon Drive, Cary, N.C. 27513
INTRINSICALLY SAFE: CL. I, Div. 1, GR. ABCD, CL.I Zone 0/1 Ex ia IIC T4Ta = -50°C TO +71°C ; IP65
REFER TO INSTALLATION DWG #651544-2 FOR CAUTION/WARNINGS WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY
Avertissement : Se référer au document DWG # 651544-2 précautions d'installations ATTENTION : La substitution de composants peut compromettre la sécurité intrinsèque
LPXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XX-XX 35.05 [1.38]
"L1"∆ "L2"
17.53 [.69]
8.97 [.35]
3.47 [.14] R
FM C
NOTES:
1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.
2. MATERIAL TO BE SCREEN PRINTED ALUMINUM WITH SATIN BACKGROUND AND BLACK TEXT OR LASER ETCHED ALUMINUM.
3. ∆ INDICATES CRITICAL DIMENSIONS.
4. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES.
5. MATERIAL: .8 [.03] THICK ALUMINUM.
6. REFER TO TABLE 1 FOR "L1" & "L2" DIMENSIONS.
APPROVED
Level Plus Transmitter
P/N 551704-X Rev E
4.0 POINT TEXT SIZE (TYP.)
SEE TABLE 1 FOR DASH #
FM LOGO ARTWORK4.5 POINT TEXT SIZE
7.5 POINT SIZE
USE MTS LOGO ARTWORK14.0 POINT SIZE
SERIAL NO./DATE CODEMTS TO PRINT MODEL NO.
"D1"
TABLE 1
DASH # HOUSING "L1" "L2" "D1"
-1 ADALET85.85 [3.38]
69.85 [2.75]
Ø2.35 [.09]x2
-2 LIMATHERM 65 [2.56] 58 [2.28] Ø 3.05 [.12] x2
E 8256 ADDED "D1" MS 2/22/17D 8183 ADDED CL 1 ZONE 0/1 MS 8/8/16C 8037 ADDED FRENCH TRANSLATION DR 10/12/15
66 SAW GNITAR PI7487B NJ 12/2/14ETADYBNOITPIRCSED#OCEVER
1
1
2
2
A A
B B
551702-
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
LEVELMETRIC
(ACP) LABEL, LP, IS CANADA-DIGITALMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
FIRST ANGLE E- THREAD DEPTHS ARE TO MIN. FULL THDS
- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
mTHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
PROPRIETARY DATA
NJDRAWN BY:
REV
SHEET
DWG NO.
1:1 11 OF
TITLEUNLESS OTHERWISE SPECIFIED
ANGLES
SIZE
SCALE:PRODUCT LINE
1 PLACEMM
TOLERANCES0 PLACES
MM 0.1 0.5
MTS Systems Corp. Sensors Division3001 Sheldon Drive, Cary, N.C. 27513
INTRINSICALLY SAFE: CL. I, Div. 1, GR. ABCD, CL. I Zone 0/1 Ex ia IIC T4 Ta = -50°C TO +71°C ; IP65
REFER TO INSTALLATION DWG #651543-2 FOR CAUTION/WARNINGS WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY
Avertissement : Se référer au document DWG # 651543-2 précautions d'installations ATTENTION : La substitution de composants peut compromettre la sécurité intrinsèque
LPXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XX-XX 35.05 [1.38]
"L1"∆ "L2"
17.53 [.69]
8.97 [.35]
3.47 [.14] R
FM C
NOTES:
1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.
2. MATERIAL TO BE SCREEN PRINTED ALUMINUM WITH SATIN BACKGROUND AND BLACK TEXT OR LASER ETCHED ALUMINUM.
3. ∆ INDICATES CRITICAL DIMENSIONS.
4. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES.
5. MATERIAL: .8 [.03] THICK ALUMINUM.
6. REFER TO TABLE 1 FOR "L1" & "L2" DIMENSIONS.
APPROVED
Level Plus Transmitter
P/N 551702-X Rev E
4.0 POINT TEXT SIZE (TYP.)
SEE TABLE 1 FOR DASH #
FM LOGO ARTWORK4.5 POINT TEXT SIZE
7.5 POINT SIZE
USE MTS LOGO ARTWORK14.0 POINT SIZE
SERIAL NO./DATE CODEMTS TO PRINT MODEL NO.
"D1"
TABLE 1
DASH # HOUSING "L1" "L2" "D1"
-1 ADALET85.85 [3.38]
69.85[2.75]
Ø2.35 [.09]x2
-2 LIMATHERM 65 [2.56] 58 [2.28] Ø 3.05 [.12] x2
E 8256 ADDED "D1" MS 2/22/17D 8183 ADDED CL 1 ZONE 0/1 MS 8/8/16C 8037 ADDED FRENCH TRANSLATION DR 10/12/15
66 SAW GNITAR PI7487B NJ 12/2/14ETADYBNOITPIRCSED#OCEVER
Level Plus® CHAMBEREDManual de operação
I 32 I
13.4.1.3 Diagrama de instalação
Fig. 34: Diagrama de instalação FMC intrinsecamente segura, Modbus e DDA, Página 1
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651543-2
1 3
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
24 VDC
COMM
ON- >
Rx/Tx+
Rx /Tx-
GROUND
EARTH GROUND(SEE NOTE 4) TERRE( Voir note 4 )
EARTH GROUND(SEE NOTE 4) TERRE( Voir note 4 )
Rx/Tx-
Rx/Tx+
GND
+24V
SAFETY BARRIER Barrière de sécurité
SAFETY BARRIER Barrière de sécurité
SAFETY BARRIER Barrière de sécurité
NO
TES: (FOR
NO
TES IN FR
ENC
H SEE PAG
E 3, NO
TES POU
R VO
IR EN
FRAN
ÇAIS PAG
E 3) 1.ALL N
ATION
AL AND
LOC
AL CO
DES AN
D R
EGU
LATION
S MU
ST BE ADH
ERED
TO W
HEN
INSTALLIN
G TH
E LEVEL SENSO
R IN
HAZAR
DO
US EN
VIRO
NM
ENTS.
SEAL ALL CO
ND
UITS W
ITHIN
457 MM
(18"). 2.LO
OP C
ABLE MU
ST BE 24 AWG
TO 14 AW
G (.511M
M² to 1.6M
M²)
SHIELD
ED TW
ISTED PAIR
CABLE W
ITH SH
IELD. C
ABLE CAPAC
ITANC
E MU
ST BE LESS TH
AN 30 pF PER
FOO
T (98 pF PER M
). CABLE SH
IELD IS C
ON
NEC
TED TO
SYSTEM G
RO
UN
D IN
NO
N-H
AZARD
OU
S AREA. SEE IN
STALLATION
MAN
UAL FO
R
ADD
ITION
AL CABLE IN
FOR
MATIO
N.
3.THE R
ESISTANC
E BETWEEN
EARTH
GR
OU
ND
AND
THE IN
TRIN
SICALLY SAFE G
RO
UN
D M
UST BE LESS TH
AN 1 O
HM
. 4.TH
E TRAN
SDU
CER
FRAM
E SHALL BE G
RO
UN
DED
TO EAR
TH G
RO
UN
D D
IREC
TLY OR
THR
OU
GH
THE EQ
UIPM
ENT O
N W
HIC
H IT IS M
OU
NTED
. 5. C
ON
TRO
L EQU
IPMEN
T CO
NN
ECTED
TO ASSO
CIATED
APPARATU
S MU
ST N
OT U
SE OR
GEN
ERATE M
OR
E THAN
250 VRM
S OR
VDC
6.ASSOC
IATED APPAR
ATUS M
ANU
FACTU
RER
'S INSTALLATIO
N D
RAW
ING
MU
ST BE FO
LLOW
ED W
HEN
INSTALLIN
G TH
IS EQU
IPMEN
T. 7.O
NLY U
SE CEC
APPRO
VED BAR
RIER
S. 8.EN
TITY PARAM
ETERS:
SU
PPLY: Rx/Tx- : R
x/Tx+ : U
i = 28VDC
Ui= 8.6V U
i= 8.6V Ii = 100m
A Ii = 10mA Ii = 10m
A C
i = 0 µF Ci = 0 µF C
i = 0 µF Li = 0 µH
Li = 0 µH Li = 0 µH
Pi = 0.7 W Pi= 0.0215 W
P i= 0.0215 W 9.TH
E ENTITY C
ON
CEPT ALLO
WS IN
TERC
ON
NEC
TION
OF IN
TRIN
SICALLY SAFE APPAR
ATUS
WITH
ASSOC
IATED APPAR
ATUS W
HEN
THE FO
LLOW
ING
IS TRU
E: Vm
ax or Ui ≥ Voc, Vt or U
o; Im
ax or Ii ≥ Isc, It or Io; Pm
ax or Pi ≥ Po; C
a ≥ Ci + C
cable; La ≥ Li + Lcable. 10.D
UAL-C
AVITY ENC
LOSU
RES:
CU
STOM
ER C
ON
NEC
TION
S WILL BE M
ADE AT TER
MIN
AL BLOC
K ON
POW
ER SID
E O
F HO
USIN
G (N
OT TO
TERM
INAL BLO
CK O
N IN
TERC
ON
NEC
T BOAR
D).
11.FOR
INSTALLATIO
N W
ITHIN
CAN
ADA SEE, C
ANAD
IAN ELEC
TRIC
AL CO
DE,
CSA N
o. C22.1.
12.THE M
AXIMU
M PER
MITTED
AMBIEN
T TEMPER
ATUR
E OF TH
E LEVEL PLUS D
IGITAL/AN
ALOG
LEVEL TR
ANSM
ITTER IS 71 °C
. TO AVO
ID TH
E EFFECTS O
F PRO
CESS TEM
PERATU
RE AN
D
OTH
ER TH
ERM
AL EFFECTS C
ARE SH
ALL BE TAKEN TO
ENSU
RE TH
E SUR
RO
UN
DIN
G AM
BIENT
AND
THE AM
BIENT IN
SIDE TH
E TRAN
SMITTER
HO
USIN
G D
OES N
OT EXC
EED 71°C
13.CAU
TION
: FLEXIBLE GAU
GES H
AVE A MIN
IMU
M BEN
D R
ADIU
S OF 381M
M(15")
14.WAR
NIN
G: TH
E APPARATU
S ENC
LOSU
RE C
ON
TAINS ALU
MIN
UM
AND
IS CO
NSID
ERED
TO C
ON
STITUTE A PO
TENTIAL R
ISK OF IG
NITIO
N BY IM
PACT O
R FR
ICTIO
N. C
ARE M
UST BE TAKEN
IN
TO AC
CO
UN
T DU
RIN
G IN
STALLATION
AND
USE TO
PREVEN
T IMPAC
T OR
FRIC
TION
15.WAR
NIN
G: SU
BSTITUTIO
N O
F CO
MPO
NEN
TS MAY IM
PAIR IN
TRIN
SIC SAFETY.
16.WAR
NIN
G: TO
PREVEN
T IGN
ITION
OF FLAM
MABLE O
R C
OM
BUSTIBLE ATM
OSPH
ERES,
DISC
ON
NEC
T POW
ER BEFO
RE SER
VICIN
G
17.WAR
NIN
G: TH
E EQU
IPMEN
T CO
NTAIN
S NO
N-M
ETALLIC EN
CLO
SUR
E PARTS, TO
PREVEN
T TH
E RISK O
F ELECTR
OSTATIC
SPARKIN
G. TH
E NO
N-M
ETALLIC SU
RFAC
E SHO
ULD
ON
LY BE C
LEANED
WITH
A DAM
P CLO
TH.
NON HAZARDOUS LOCATION NON ZONE DANGEREUSE
HAZARDOUS LOCATION ZONE DANGEREUSE
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(CAN
ADA). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
AGEN
CE D
ESSIN contrôlée ( C
ANAD
A ) . AUC
UN
CH
ANG
EMEN
T sans l'accord préalable AGEN
CE APPR
OBATIO
N
EARTH TERMINAL
BORNE DE TERRE
(ACP) INSTALLATIN DWG LP DIGITAL
INTRINSICALLY SAFE FOR CANADA
LEVEL
FM
APPROVED
C
N/A
INTRINSICALLY SAFE (INTRINSÈQUEMENT SÛR)
CL. I, DIV. 1, GR. ABCDCL. I Zone 0/1 Ex ia IIC T4 Ta =
-50 to 71°C ; IP65
Level Plus® CHAMBEREDManual de operação
I 33 I
Fig. 35: Diagrama de instalação FMC intrinsecamente segura, Modbus e DDA, Página 2
DETAIL ASCALE 1.60 : 1
DETAIL CSCALE 3 : 1
DETAIL DSCALE 1.2
DETAIL ESCALE 1 : 1
A
C
D
E
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651543-2
2 3
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
+24V GNDEARTHTX/RX+TX/RX-
GND+24V
TX/RX-TX/RX+EARTH
GND+24V
TX/RX-
TX/RX+
EARTH
FIGU
RE 1
SING
LE CAVITY & N
EMA H
OU
SING
(Seule cavité & NEM
A LOG
EMEN
T)FIG
UR
E 2D
UAL C
AVITY HO
USIN
G(C
avité double LOG
EMEN
T)
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM Le client doit relier la m
asse LUG
à l'extérieur pour le système au sol SÉC
UR
ITÉ DE TER
RE
WAR
NIN
G:
CO
ND
UIT SEALS R
EQU
IRED
WITH
IN 457 M
M (18") O
F HO
USIN
G.
Étanchéité des conduits requis dans les 457 mm
( 18 " ) DU
LOG
EMEN
T
(ACP) INSTALLATIN DWG LP DIGITAL
INTRINSICALLY SAFE FOR CANADA
+24V GND EARTH Tx/Rx+ Tx/Rx-
PIN WIRING CHART (FOR NEM
A GAGUE)
WIRING CHART (FOR NEM
A GAUGE)
LEVEL
WIRE COLOR
SIGNALRED
24 V PWR
BLACK 0 V PW
RBLUE
N/AW
HITERX TX +
GREENRX TX -
DRAIN WIRE
EARTH GROUND
PIN #SIGNAL
PIN 124 V PW
RPIN 2
0 V PWR
PIN 3N/A
PIN 4RX TX+
PIN 5RX TX-
PIN 6EARTH GROUND
Level Plus® CHAMBEREDManual de operação
I 34 I
Fig. 36: Diagrama de instalação FMC intrinsecamente segura, Modbus e DDA, Página 3
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651543-2
3 3
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
NO
TES:1. La réglem
entation doit être respectée suivant les codes locaux et nationaux LO
RS D
'INSTALLATIO
N D
U C
APTEUR
DE N
IVEAU D
ANS D
ES ENVIR
ON
NEM
ENTS D
ANG
EREU
X.Sceller tous les conduits à m
oins de 457 mm
(18 " ). 2. Boucle de câble doit être de 24 AW
G à 14 AW
G (.511M
M2 à 1.6M
M2)
Paire Torsadée Blindée avec le bouclier. La capacité du câble devraÊtre inférieure à 30 pF PAR
PIED (98 pF PAR
M). Le blindage du câble est raccordé
À la terre EN ZO
NE N
ON
DAN
GER
EUSE. VO
IR m
anuel d'installationIN
FOR
MATIO
NS de câble supplém
entaire. 3. La résistance entre la TER
RE ET la zone IN
TRIN
SEQU
ED
oit être inférieure à 1 ohm.
4. Le boîtier du capteur doit être relié à la TERR
E directement ou par
L'équipement sur lequel il est m
onté. 5. Equipem
ent de comm
ande relié à l'appareil associé ne doit pas utiliser ou générer plus de 250 VRM
S OU
VDC
6 Le plan d'installation associé du fabricant de l'appareil doit être suivi lors de l'installation de cet équipement
7. UTILISER
UN
IQU
EMEN
T DES BAR
RIER
ES APPRO
UVÉES C
EC.
8. PARAM
ÈTRES :
SUPPLY: R
x/Tx- : Rx/Tx+ :
Ui = 28VD
C U
i= 8.6V Ui= 8.6V
Ii = 100mA Ii = 10m
A Ii = 10mA
Ci = 0 µF C
i = 0 µF Ci = 0 µF
Li = 0 µH Li = 0 µH
Li = 0 µHPi = 0.7 W
Pi= 0.0215 W Pi= 0.0215 W
9. Le concept de l'entité permet l'interconnexion de l'appareil de sécurité intrinsèque avec un appareil associé lorsque la suivante est vraie :
Vmax or U
i > Voc, Vt or Uo;
Imax or Ii > Isc, It or Io;
Pmax or Pi > Po;
Ca > C
i + Ccable;
La > Li + Lcable. 10. EN
CEIN
TES à cavité double : Les raccordements clients, seront effectués au bornier d'alim
entation sur le côté du LOG
EMEN
T boîtier (pas au bornier carte d'interconnexion) 11. Pour une IN
STALLATION
AU C
ANAD
A, suivre LE CO
DE C
ANAD
IEN D
E L'ÉLECTR
ICITÉ,
CSA N
o C22.1.
12. La TEMPÉR
ATUR
E AMBIAN
TE maxim
um autorisé pour le capteur LEVEL PLU
S version DIG
ITAL ou ANALO
GIQ
UE est de 71 C
°. Pour éviter les effets de la tem
pérature sur le processus des protections thermiques doivent être prises pour assurer la tem
pérature ambiante environnante et ainsi qu'à l'intérieur
du boîtier du capteur la température ne doit pas dépasser 71 C
° 13. ATTEN
TION
: Le flexible du capteur a un rayon minim
um de courbure de 381 m
m (15 ")
14. ATTENTIO
N : Le boîtier de l'appareil contient de l'alum
inium et est considéré
CO
NSTITU
ER U
N R
ISQU
E potentiel de générer des étincelles en cas de choc ou de frottement. VEU
ILLEZ EN TEN
IR C
OM
PTE LOR
S DE
L'INSTALLATIO
N ET U
TILISATION
POU
R ÉVITER
choc ou frottement
15. ATTENTIO
N : La substitution de com
posants peut comprom
ettre la sécurité intrinsèque. 16. ATTEN
TION
: Pour éviter l'inflamm
ation d'atmosphères inflam
mables ou com
bustibles,D
ÉBRAN
CH
EZ L'ALIMEN
TATION
AVANT D
'INTER
VENIR
17. ATTENTIO
N : l'équipem
ent contient DES PIEC
ES NO
N M
ETALLIQU
E, POU
R EVITER
LE RISQ
UE ÉLEC
TRO
STATIQU
E, étincelles. La surface non métallique doit SEU
LEMEN
T Être nettoyée avec un chiffon humid
(ACP) INSTALLATIN DWG LP DIGITAL
INT RINSICALLY SAFE FOR CANADA
LEVEL
Level Plus® CHAMBEREDManual de operação
I 35 I
Fig. 37: Diagrama de instalação FMC intrinsecamente segura, HART®, Página 1
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651544-2LEVEL
1 3
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
NO
N H
AZARD
OU
S LOC
ATION
NO
N ZO
NE D
ANG
EREU
SEH
AZARD
OU
S LOC
ATION
ZON
E DAN
GER
EUSE
NO
TES: (FOR
NO
TES IN FR
ENC
H SEE PAG
E 3, NO
TES POU
R VO
IR EN
FRAN
AIS PAGE 3)
1. ALL NATIO
NAL AN
D LO
CAL C
OD
ES AND
REG
ULATIO
NS M
UST BE AD
HER
ED TO
WH
EN IN
STALLING
THE M
TS LP SENSO
R IN
HAZAR
DO
US EN
VIRO
NM
ENTS.
SEAL ALL CO
ND
UITS W
ITHIN
457 MM
(18"). 2. LO
OP C
ABLE MU
ST BE 24 AWG
TO 14 AW
G (.511M
M² to 1.6M
M²)
SHIELD
ED TW
ISTED PAIR
CABLE W
ITH SH
IELD. C
ABLE CAPAC
ITANC
E MU
ST BE LESS TH
AN 30 pF PER
FOO
T (98 pF PER m
). CABLE SH
IELD IS C
ON
NEC
TED TO
SYSTEM G
RO
UN
D IN
NO
N-H
AZARD
OU
S AREA. SEE IN
STALLATION
MAN
UAL FO
R
ADD
ITION
AL CABLE IN
FOR
MATIO
N.
3. THE R
ESISTANC
E BETWEEN
EARTH
GR
OU
ND
AND
THE IN
TRIN
SICALLY SAFE G
RO
UN
D M
UST BE LESS TH
AN 1 O
HM
. 4. TH
E TRAN
SDU
CER
FRAM
E SHALL BE G
RO
UN
DED
TO EAR
TH G
RO
UN
D D
IREC
TLY OR
THR
OU
GH
THE EQ
UIPM
ENT O
N W
HIC
H IT IS M
OU
NTED
. 5. C
ON
TRO
L EQU
IPMEN
T CO
NN
ECTED
TO ASSO
CIATED
APPARATU
S MU
ST N
OT U
SE OR
GEN
ERATE M
OR
E THAN
250 VRM
S OR
VDC.
6. ASSOC
IATED APPAR
ATUS M
ANU
FACTU
RER
'S INSTALLATIO
N D
RAW
ING
MU
ST BE FO
LLOW
ED W
HEN
INSTALLIN
G TH
IS EQU
IPMEN
T 7. O
NLY U
SE CEC
APPRO
VED BAR
RIER
S. 8. APPR
OVED
LOO
P SEPARATIO
N M
ETHO
DS:
*RU
N LO
OPS IN
SEPARATE C
ABLES *R
UN
LOO
PS IN SEPAR
ATE GR
OU
ND
ED SH
IELDS
9. ENTITY PAR
AMETER
S EACH
LOO
P: U
i = 28 VDC
Ii = 120 mA
Ci = 0 µF
Li = 5 µH Pi = 840 m
W 10. D
UAL-C
AVITY ENC
LOSU
RES:
CU
STOM
ER C
ON
NEC
TION
S WILL BE M
ADE AT TER
MIN
AL BLOC
K ON
POW
ER SID
E O
F HO
USIN
G (N
OT TO
TERM
INAL BLO
CK O
N IN
TERC
ON
NEC
T BOAR
D)
11 FOR
INSTALLATIO
N W
ITHIN
CAN
ADA, SEE C
AN
ADIAN
ELECTR
ICAL C
OD
E, CSA N
o C22.1.
12.THE M
AXIMU
M PER
MITTED
AMBIEN
T TEMPER
ATUR
E OF TH
E LEVEL PLUS D
IGITAL/AN
ALOG
LEVEL TR
ANSM
ITTER IS 71 °C
. TO AVO
ID TH
E EFFECTS O
F PRO
CESS TEM
PERATU
RE AN
D
OTH
ER TH
ERM
AL EFFECTS C
ARE SH
ALL BE TAKEN TO
ENSU
RE TH
E SUR
RO
UN
DIN
G AM
BIENT
AND
THE AM
BIENT IN
SIDE TH
E TRAN
SMITTER
HO
USIN
G D
OES N
OT EXC
EED 71°C
13.CAU
TION
: FLEXIBLE GAU
GES H
AVE A MIN
IMU
M BEN
D R
ADIU
S OF 381M
M(15")
14. WAR
NIN
G: TH
E APPARATU
S ENC
LOSU
RE C
ON
TAINS ALU
MIN
UM
AND
IS CO
NSID
ERED
TO C
ON
STITUTE A PO
TENTIAL R
ISK OF IG
NITIO
N BY IM
PACT O
R FR
ICTIO
N. C
ARE M
UST BE TAKEN
IN
TO AC
CO
UN
T DU
RIN
G IN
STALLATION
AND
USE TO
PREVEN
T IMPAC
T OR
FRIC
TION
15.WAR
NIN
G: SU
BSTITUTIO
N O
F CO
MPO
NEN
TS MAY IM
PAIR IN
TRIN
SIC SAFETY.
16.WAR
NIN
G: TO
PREVEN
T IGN
ITION
OF FLAM
MABLE O
R C
OM
BUSTIBLE ATM
OSPH
ERES
. D
ISCO
NN
ECT PO
WER
BEFOR
E SERVIC
ING
. 17.W
ARN
ING
: THE EQ
UIPM
ENT C
ON
TAINS N
ON
-METALLIC
ENC
LOSU
RE PAR
TS, TO PR
EVENT
THE R
ISK OF ELEC
TRO
STATIC SPAR
KING
. THE N
ON
-METALLIC
SUR
FACE SH
OU
LD O
NLY
BE CLEAN
ED W
ITH A D
AMP C
LOTH
.
EARTH
GR
OU
ND
LUG
NO
TE 3
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(Canada). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
AGEN
CE D
ESSIN contrôlée ( C
ANAD
A ) . AUC
UN
CH
ANG
EMEN
T sans l'accord préalable AGEN
CE APPR
OBATIO
N
24 VDC
CO
NTR
OL
INPU
T 1
CO
NTR
OL
INPU
T 2
APPRO
VED SAFETY
BARR
IER sécurité approuvé BAR
RIÈR
ELO
OP VO
LTAGE
SHIELD
SHIELD
LOO
P 1+
LOO
P 1-
LOO
P 2+
LOO
P 2-
FM
APPROVED
C
(ACP) INSTALLATIN DWG LP ANALOG
INTRINSICALLY SAFE FOR CANADA
SING
LE OR
DU
AL CAVITY
NEM
A HO
USIN
G
F
INTRINSICALLY SAFECL. I, DIV. 1, GR. ABCDCL.I Zone 0/1 Ex ia IIC T4Ta =
-50 to 71°C ; IP65
APPRO
VED SAFETY
BARR
IER sécurité approuvé BAR
RIÈR
E
EARTH GROUND(SEE NOTE 4) TERRE( Voir note 4 )
EARTH GROUND(SEE NOTE 4) TERRE( Voir note 4 )
Level Plus® CHAMBEREDManual de operação
I 36 I
Fig. 38: Diagrama de instalação FMC intrinsecamente segura, HART®, Página 2
DETAIL D
SCALE 3
DETAIL E
SCALE 1.60
DETAIL F
SCALE 1.2
DETAIL H
SCALE 1 : 1
D
E
F
H
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651544-2LEVEL
2 3
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
LOOP 2-
LOOP 2+
EARTH
LOOP 1-
LOOP 1+
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM Le client doit relier la m
asse LUG
à l'extérieur pour le système au sol SÉC
UR
ITÉ DE TER
RE
WAR
NIN
G:
CO
ND
UIT SEALS R
EQU
IRED
WITH
IN 457 M
M (18") O
F HO
USIN
G.
Étanchéité des conduits requis dans les 457 mm
( 18 " ) DU
LOG
EMEN
T.
FIGU
RE 2
DU
AL CAVITY H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
FIGU
RE 1
SING
LE CAVITY & N
EMA H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
F
PIN WIRING CHART (FOR NEM
A GAUGE)
WIRING CHART(FOR NEM
A GAUGE)
(ACP) INSTALLATIN DWG LP ANALOG
INTRINSICALLY SAFE FOR CANADA
WIRE COLOR
SIGNALRED
LOOP 1+BLACK
LOOP 1-BLUE
LOOP 2-W
HITELOOP 2+
GREENN/A
DRAIN WIRE
EARTH GROUND
PIN #SIGNAL
PIN 1LOOP 1-
PIN 2LOOP 1+
PIN 3LOOP 2-
PIN 4LOOP 2+
PIN 5N/A
PIN 6EARTH GROUND
Level Plus® CHAMBEREDManual de operação
I 37 I
Fig. 39: Diagrama de instalação FMC intrinsecamente segura, HART®, Página 3
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651544-2LEVEL
3 3
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
NO
TES:1. La réglem
entation doit être respectée suivant les codes locaux et nationaux LO
RS D
'INSTALLATIO
N D
U C
APTEUR
DE N
IVEAU D
ANS D
ES ENVIR
ON
NEM
ENTS D
ANG
EREU
X.Sceller tous les conduits à m
oins de 457 mm
(18 " ). 2. Boucle de câble doit être de 24 AW
G à 14 AW
G (.511M
M2 à 1.6M
M2)
Paire Torsadée Blindée avec le bouclier. La capacité du câble devraÊtre inférieure à 30 pF PAR
PIED (98 pF PAR
M). Le blindage du câble est raccordé
À la terre EN ZO
NE N
ON
DAN
GER
EUSE. VO
IR m
anuel d'installationIN
FOR
MATIO
NS de câble supplém
entaire. 3. La résistance entre la TER
RE ET la zone IN
TRIN
SEQU
ED
oit être inférieure à 1 ohm.
4. Le boîtier du capteur doit être relié à la TERR
E directement ou par
L'équipement sur lequel il est m
onté. 5. Equipem
ent de comm
ande relié à l'appareil associé ne doit pas utiliser ou générer plus de 250 VRM
S OU
VDC
6 Le plan d'installation associé du fabricant de l'appareil doit être suivi lors de l'installation de cet équipement
7. UTILISER
UN
IQU
EMEN
T DES BAR
RIER
ES APPRO
UVÉES C
EC 8. approuvent les m
éthodes de séparation Loop: * BO
UC
LES RU
N dans des câbles séparés
* BOU
CLES R
UN
Shields terre séparés 9. Param
ètres d'entité chaque boucle: U
i = 28 VDC
Ii = 120 mA
Ci = 0 µF
Li = 5 µH Pi = 840 m
W 10. EN
CEIN
TES à cavité double : Les raccordements clients, seront effectués au bornier d'alim
entation sur le côté du LO
GEM
ENT boîtier (pas au bornier carte d'interconnexion)
11. Pour une INSTALLATIO
N AU
CAN
ADA, suivre LE C
OD
E CAN
ADIEN
DE L'ÉLEC
TRIC
ITÉ,C
SA No C
22.1. 12. La TEM
PÉRATU
RE AM
BIANTE m
aximum
autorisé pour le capteur LEVEL PLUS version D
IGITAL ou
ANALO
GIQ
UE est de 71 C
°. Pour éviter les effets de la température sur le processus des protections therm
iques doivent être prises pour assurer la tem
pérature ambiante environnante et ainsi qu'à l'intérieur du boîtier du capteur la
température ne doit pas dépasser 71 C
° 13. ATTEN
TION
: Le flexible du capteur a un rayon minim
um de courbure de 381m
m (15 ")
14. ATTENTIO
N : Le boîtier de l'appareil contient de l'alum
inium et est considéré
CO
NSTITU
ER U
N R
ISQU
E potentiel de générer des étincelles en cas de choc ou de frottement. VEU
ILLEZ EN TEN
IR
CO
MPTE LO
RS D
E L'INSTALLATIO
N ET U
TILISATION
POU
R ÉVITER
choc ou frottement
15. ATTENTIO
N : La substitution de com
posants peut comprom
ettre la sécurité intrinsèque. 16. ATTEN
TION
: Pour éviter l'inflamm
ation d'atmosphères inflam
mables ou com
bustibles,D
ÉBRAN
CH
EZ L'ALIMEN
TATION
AVANT D
'INTER
VENIR
17. ATTENTIO
N : l'équipem
ent contient DES PIEC
ES NO
N M
ETALLIQU
E, POU
R EVITER
LE RISQ
UE ÉLEC
TRO
STATIQU
E, étincelles. La surface non métallique doit SEU
LEMEN
T Être nettoyée avec un chiffon hum
id
F
(ACP) INSTALLATIN DWG LP ANALOG
INTRINSICALLY SAFE FOR CANADA
Level Plus® CHAMBEREDManual de operação
I 38 I
13.4.2 À prova de explosão / à prova de chamas
13.4.2.1 Condições especificas de uso seguro
1. Aviso: O equipamento contém um gabinete não metálica e parte do processo para evitar o risco de faísca eletrostática. A superfície não metálica deve ser limpa apenas com um pano úmido. A superfície pintada do equipamento pode armazenar descarga eletrostática e tornar-se uma fonte de ignição em aplicações com umidade relativa baixa (<~30%) em que a superfície pintada é relativamente livre de contaminação da superfície como sujeiras, poeira ou óleo. A limpeza da superfície pintada deve ser feita apenas com um pano úmido.
2. Os cabos devem ter a classificação > 5 °C acima da temperatura ambiente máxima.
3. Para manter a classificação de proteção contra entrada do IP65, a fita Teflon™ (3 voltas) ou cola para canos deve ser usada. Consulte as instruções de instalação.
4. O equipamento pode ser instalado na parede entre uma área EPL Ga e uma área menos perigosa, EPL Gb. Nessa configuração, a conexão do processo está instalada em EPL Ga, enquanto o invólucro do transmissor está instalado no EPL Gb. Consulte as instruções de instalação.
5. Os medidores flexíveis têm um raio de curvatura mínimo de 381 mm (15 pol.).
6. Caminho da chama não para reparo. 7. A classe de temperatura aplicável, faixa de temperatura
de processo e a faixa de temperatura ambiente do equipamento estão abaixo:• T3 com a faixa de temperatura de processo −40 °C a +150 °C • T4 com a faixa de temperatura de processo −40 °C a +135 °C• T5 com a faixa de temperatura de processo −40 °C a +100 °C• T6 com a faixa de temperatura de processo −40 °C a +85 °C• A faixa de temperatura ambiente é de −40 °C ≤ Ta ≤ 71 °C
8. Quando montar em um MLG (medidor magnético de nível), certifique-se o cabeçote eletrônico e a barreira de pressão têm um espaçamento mínimo de 5 pol. Consulte o Manual de instalação para detalhes.
Fig. 40: À prova de explosão, etiqueta FMC, Modbus ou DDA, opções de invólucro G, H ou L
Fig. 41: À prova de explosão, etiqueta FMC, Modbus ou DDA, opções de invólucro D, E
Fig. 42: À prova de explosão, etiqueta FMC, HART®, opções de invólucro G, H ou L
Fig. 43: À prova de explosão, etiqueta FMC, HART®, opções de invólucro D, E
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551706-x A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 7/28/16
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
Level Plus Transmitter
FM16CA0130X
INSTALL PER # 651552-2MAX. PRESSURE 1000 PSI (RIGID SENSOR)MAX. PRESSURE 435 PSI (FLEX SENSOR)INPUT: 28V (120mA)max OUTPUT: RS485
WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. FOR ZONE INSTALLATIONS, A SEAL SHALL BE INSTALLED WITHIN 50mm OF THE ENCLOSURE. FOR DIVISION INSTALLATIONS A SEAL SHALL BE INSTALLED WITHIN 18 INCHESOF THE ENCLOSURE ATTENTION : NE PAS OUVRIR UNE ATMOSPHÈRE EXPLOSIVE PRESENT.POUR INSTALLATIONS DE ZONE, UN SORTIE EST INSTALLÉ DANS LES 50 mm DE L'ENCEINTE. POUR INSTALLATIONS DE DIVISION ALE SORTIE EST INSTALLÉ DANS LES 18 POUCES DE L'ENCEINTE
EXPLOSIONPROOF CL. I, DIV. 1, GR BCD T6...T3. Ex db IIB+H2 T6...T3 Ga/Gb Ta = -40°C to +71°C ; IP 65
7957 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP CANADA - DIGITAL
R FM APPROVED
P/N 551706-1 REV A
LEVEL
1:1
!
C 1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551706-x A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 7/28/16
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
Level Plus Transmitter
FM16CA0130X
INSTALL PER # 651552-2MAX. PRESSURE 1000 PSI (RIGID SENSOR)MAX. PRESSURE 435 PSI (FLEX SENSOR)INPUT: 28V (120mA)max OUTPUT: RS485
WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. FOR ZONE INSTALLATIONS, A SEAL SHALL BE INSTALLED WITHIN 50mm OF THE ENCLOSURE. FOR DIVISION INSTALLATIONS A SEAL SHALL BE INSTALLED WITHIN 18 INCHESOF THE ENCLOSURE ATTENTION : NE PAS OUVRIR UNE ATMOSPHÈRE EXPLOSIVE PRESENT.POUR INSTALLATIONS DE ZONE, UN SORTIE EST INSTALLÉ DANS LES 50 mm DE L'ENCEINTE. POUR INSTALLATIONS DE DIVISION ALE SORTIE EST INSTALLÉ DANS LES 18 POUCES DE L'ENCEINTE
EXPLOSIONPROOF CL. I, DIV. 1, GR. BCD T6...T3 Ex db IIB+H2 T6...T3 Ga/Gb Ta = -40°C to +71°C ; IP 65
7957 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP CANADA - DIGITAL
R FM APPROVED
P/N 551706-2 REV A
LEVEL
1:1
!
C 1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551708-x A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 7/28/16
Level Plus TransmitterFM16CA0130X
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. FOR ZONE INSTALLATIONS, A SEAL SHALL BE INSTALLED WITHIN 50mm OF THE ENCLOSURE. FOR DIVISION INSTALLATIONS A SEAL SHALL BE INSTALLED WITHIN 18 INCHESOF THE ENCLOSURE. ATTENTION : NE PAS OUVRIR UNE ATMOSPHÈRE EXPLOSIVE PRESENT POUR INSTALLATIONS DE ZONE, UN SORTIE EST INSTALLÉ DANS LES 50 mm DE L'ENCEINTE. POUR INSTALLATIONS DE DIVISION ALE SORTIE EST INSTALLÉ DANS LES 18 POUCES DE L'ENCEINTE
EXPLOSIONPROOF CL. I, DIV. 1, GR.Ex db IIB+H2 T6...T3 Ga/Gb Ta = -40°C to +71°C ; IP 65
INSTALL PER # 651553-2MAX. PRESSURE 1000 PSI (RIGID SENSOR)MAX. PRESSURE 435 PSI (FLEX SENSOR)INPUT: 28V (120mA)max OUTPUT: 4-20mA
7957 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP CANADA - ANALOG
BCD T6...T3
FM APPROVED
P/N 551708-1 Rev A
LEVEL
1:1
R
!
C 1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551708-x A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 7/28/16
Level Plus TransmitterFM16CA0130X
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. FOR ZONE INSTALLATIONS, A SEAL SHALL BE INSTALLED WITHIN 50mm OF THE ENCLOSURE. FOR DIVISION INSTALLATIONS A SEAL SHALL BE INSTALLED WITHIN 18 INCHESOF THE ENCLOSURE. ATTENTION : NE PAS OUVRIR UNE ATMOSPHÈRE EXPLOSIVE PRESENT POUR INSTALLATIONS DE ZONE, UN SORTIE EST INSTALLÉ DANS LES 50 mm DE L'ENCEINTE. POUR INSTALLATIONS DE DIVISION ALE SORTIE EST INSTALLÉ DANS LES 18 POUCES DE L'ENCEINTE
EXPLOSIONPROOF CL. I, DIV. 1, GR. BCD T6...T3Ex db IIB+H2 T6...T3 Ga/Gb Ta = -40°C to +71°C ; IP 65
INSTALL PER # 651553-2MAX. PRESSURE 1000 PSI (RIGID SENSOR)MAX. PRESSURE 435 PSI (FLEX SENSOR)INPUT: 28V (120mA)max OUTPUT: 4-20mA
7957 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP CANADA - ANALOG
FM APPROVED
P/N 551708-2 Rev A
LEVEL
1:1
R
!
C
13.4.2.2 Etiquetas
Level Plus® CHAMBEREDManual de operação
I 39 I
13.4.2.3 Diagrama de instalação
Fig. 44: À prova de explosão, diagrama de instalação FMC, Modbus e DDA, Página 1
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651553-2B
LEVEL1
3 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***B
MS
10/22/15RELEASE TO PRODUCTION
8482UPDATED W
IRING DWG TO ANALOG
MS
5/17/18A
7957
LOOP 2+
LOOP 2-
EARTH GROUND
LOOP 1+
LOOP 1-
EARTH GROUND
SEE NOTE 8EPL Ga
EPL Gb
NO
N H
AZARD
OU
S LOC
ATION
HAZAR
DO
US LO
CATIO
N
EARTH
GR
OU
ND
LUG
NO
TE 3
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(Canada). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
FM
APPROVED
C
(ACP) INSTALLATION DWG LP ANALOG
EXPLOSION PROOF CANADA
SING
LE OR
DU
AL CAVITY
FM Canada - FM
16CA0130X
EXPLOSION PROOFCL. I, DIV. 1, GR. BCD T6...T3Ex db IIB+H2 T6...T3 Ga/GbTa = -40°C to +71°C ; IP65
CO
ND
UIT SEAL
CO
ND
UIT
CO
ND
UIT SEAL
SEE NO
TE 1
NO
TES:1.ALL N
ATION
AL AND
LOC
AL CO
DES AN
D R
EGU
LATION
S MU
ST BE ADH
ERED
TO W
HEN
INSTALLIN
G TH
E LEVEL SENSO
R IN
HAZAR
DO
US EN
VIRO
NM
ENTS.
FOR
ZON
E INSTALLATIO
NS, A SEAL SH
ALL BE INSTALLED
WITH
IN 50m
m O
F THE
ENC
LOSU
RE. FO
R D
IVISION
INSTALLATIO
NS, A SEAL SH
ALL BE INSTALLED
WITH
IN 18 IN
CH
ES OF TH
E ENC
LOSU
RE.
2.DU
AL-CAVITY EN
CLO
SUR
ES: C
USTO
MER
CO
NN
ECTIO
NS W
ILL BE MAD
E AT TERM
INAL BLO
CK O
N PO
WER
SIDE
OF H
OU
SING
(NO
T TO TER
MIN
AL BLOC
K ON
INTER
CO
NN
ECT BO
ARD
). SEE FIGU
RE 2 O
N PAG
E 23. C
AUTIO
N: FLEXIBLE G
AUG
ES HAVE A M
INIM
UM
BEND
RAD
IUS O
F 381mm
(15")4.W
ARN
ING
: TO PR
EVENT IG
NITIO
N O
F FLAMM
ABLE OR
CO
MBU
STIBLE ATMO
SPHER
ES, D
ISCO
NN
ECT PO
WER
BEFOR
E SERVIC
ING
5.W
ARN
ING
: THE EQ
UIPM
ENT C
ON
TAINS N
ON
-METALLIC
ENC
LOSU
RE AN
D PR
OC
ESS PARTS, TO
PREVEN
T TH
E RISK O
F ELECTR
OSTATIC
SPARK IN
G. TH
E NO
N-M
ETALLIC SU
RFAC
E AND
PRO
CESS PAR
TS SHO
ULD
ON
LY BE C
LEANED
WITH
A DAM
P CLO
TH. PAINTED SURFACE OF THE EQUIPM
ENT MAY STORE ELECTROSTATIC CHARGE
AND BECOME A SOURCE OF IGNITION IN APPLICATIONS W
ITH A LOW RELATIVE HUM
IDITY <~30% RELATIVE
HUMIDITY W
HERE THE PAINTED SURFACE IS RELATIVELY FREE OF SURFACE CONTAMINATION
SUCH AS DIRT, DUST OR OIL. CLEANING OF THE PAINTED SURFACE SHOULD ONLY BE DONE W
ITH A DAMP CLOTH.
6. CABLES SH
ALL BE RATED
> 5C ABO
VE MAXIM
UM
AMBIEN
T TEMPER
ATUR
E. 7. TO
MAIN
TAIN TH
E ING
RESS PR
OTEC
TION
RATIN
G O
F IP65, TEFLON
TAPE (3 WR
APS) OR
PIPE DO
PE SHALL
BE USED
. REFER
TO IN
STALLATION
INSTR
UC
TION
S.8. TH
E EQU
IPMEN
T CAN
BE INSTALLED
IN TH
E BOU
ND
ARY W
ALL BETWEEN
A ZON
E 0 AREA AN
D TH
E LESS H
AZARD
OU
S AREA, ZO
NE 1. IN
THIS C
ON
FIGU
RATIO
N, TH
E PRO
CESS C
ON
NEC
TION
IS INSTALLED
IN
A ZON
E 0 AREA, W
HILE TH
E TRAN
SMITTER
HO
USIN
G IS IN
STALLED IN
A ZON
E 1 AREA.
9. THE APPLIC
ABLE TEMPER
ATUR
E CLASS O
F THE EQ
UIPM
ENT, AM
BIENT TEM
PERATU
RE R
ANG
E, AN
D M
AXIMU
M PR
OC
ESS TEMPER
ATUR
E OF TH
E EQU
IPMEN
T IS AS FOLLO
WS;
T3 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +150°C T4 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +135°C
T5 WITH
PRO
CES S TEM
PERATU
RE R
ANG
E OF -40°C
to +100°C T6 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +85°C
AMBIEN
T TEMPER
ATUR
E RAN
GE -40°C Ta+71°C
10. WH
EN M
OU
NTIN
G O
N A M
AGN
ETIC LEVEL G
AUG
E MAKE SU
RE TH
E ELECTR
ON
IC H
EAD AN
D PR
ESSUR
E BAR
RIER
HAVE A M
INIM
UM
SPACIN
G O
F 5 INC
HES. SEE IN
STALLATION
MAN
UAL FO
R D
ETAIL11. FLAM
EPATHS AR
E NO
T FOR
REPAIR
5"[127mm
] Minim
um
Level Plus® CHAMBEREDManual de operação
I 40 I
Fig. 45: À prova de explosão, diagrama de instalação FMC, Modbus e DDA, Página 2
DETAIL D
SCALE 3
DETAIL E
SCALE 1.60
DETAIL F
SCALE 1.2
D
E
F
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651553-2B
LEVEL2
3 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***B
MS
10/22/15RELEASE TO PRODUCTION
8482UPDATED W
IRING DWG TO ANALOG
MS
5/17/18A
7957
LOOP 2-
LOOP 2+
EARTH
LOOP 1-
LOOP 1+
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: W
HEN
INSTALLIN
G TH
E LEVEL SENSO
R IN
HAZAR
DO
US EN
VIRO
NM
ENTS.
FOR
ZON
E INSTALLATIO
NS, A SEAL SH
ALL BE INSTALLED
WITH
IN 50m
m O
F THE
ENC
LOSU
RE. FO
R D
IVISION
INSTALLATIO
NS, A SEAL SH
ALL BE INSTALLED
WITH
IN 18 IN
CH
ES OF TH
E ENC
LOSU
RE.
FIGU
RE 2
DU
AL CAVITY H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
FIGU
RE 1
SING
LE CAVITY H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
(ACP) INSTALLATION DWG LP ANALOG
EXPLOSION PROOF CANADA
Level Plus® CHAMBEREDManual de operação
I 41 I
Fig. 46: À prova de explosão, diagrama de instalação FMC, Modbus e DDA, Página 3
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651553-2B
LEVEL3
3 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***B
MS
10/22/15RELEASE TO PRODUCTION
8482UPDATED W
IRING DWG TO ANALOG
MS
5/17/18A
7957
NO
TES:1. La réglem
entation doit être respectée suivant les codes locaux et nationaux LO
RS D
'INSTALLATIO
N D
U C
APTEUR
DE N
IVEAU D
ANS D
ES ENVIR
ON
NEM
ENTS D
ANG
EREU
X. PO
UR
INSTALLATIO
NS D
E ZON
E, UN
SOR
TIE EST INSTALLÉ D
ANS LES 50 m
m D
E L'ENC
EINTE.
POU
R IN
STALLATION
S DE D
IVISION
ALE SOR
TIE EST INSTALLÉ D
ANS LES 18 PO
UC
ES DE L'EN
CEIN
TE2. EN
CEIN
TES à cavité double : Les raccordements clients, seront effectués au bornier d'alim
entation sur le côté du LOG
EMEN
T boîtier (pas au bornier carte d'interconnexion) 3. ATTEN
TION
: LES INSTR
UM
ENTS FLEXIBLES AVEC
UN
RAD
IOD
E MIN
IMU
M D
E 381mm
(15 ")4. ATTEN
TION
: Pour éviter l'inflamm
ation d'atmosphères inflam
mables ou com
bustibles , D
ÉBRAN
CH
EZ L'ALIMEN
TATION
AVANT D
'INTER
VENIR
5. AVERTISSEM
ENT: L'ÉQ
UIPEM
ENT C
ON
TENU
E DES PIÈC
ES ET PRO
CÉD
ÉS NO
N-M
ETALLIQU
ES POU
R PR
ÉVENIR
LE RISQ
UE D
'ÉCLAIR
AGE ÉLEC
TRO
STATIQU
E. LA SUR
FACE ET LES PIÈC
ES DE PR
OC
ÉDU
RE N
ON
MÉTALLIQ
UES D
OIVEN
T SEULEM
ENT
EFFECTEZ U
N PAN
NEAU
DE PLAISIR
. LA SUR
FACE PEIN
TÉE DE L'ÉQ
UIPEM
ENT PEU
T CO
NSER
VER LE C
HAR
GE ÉLEC
TRO
STATIQU
E ET D
EVENIR
UN
E SOU
RC
E D'A LLU
MAG
E DAN
S DES APPLIC
ATION
S AVEC U
NE H
UM
IDITÉ BASSE R
ELATIVE <~ 30% R
ELATIVE H
UM
IDITE O
Ù LA SU
RFAC
E PEINTU
RE EST R
ELATIVEMEN
T LIBRE D
E CO
NTAM
INATIO
N D
E SUR
FACE
TELS QU
E LA VIAND
E, LA POU
SSIÈRE O
U L'H
UILE. LE N
ETTOYAG
E DE LA SU
RFAC
E PEINTU
RE D
OIT ÊTR
E FAIT AVEC
UN
PANN
EAU D
E PLAISIR.
6. CABLES doit être évalué> 5C
DESSU
S MAXIM
UM
TEMPER
ATUR
E AMBIAN
TE.7. PO
UR
MAIN
TENIR
LA NO
TATION
DE PR
OTEC
TION
DE IN
GR
ESS IP65, du ruban téflon (3 BAND
ES) ou PIPE DO
PE DEVR
A ÊTRE U
TILISÉ. CO
NSU
LTER LES IN
STRU
CTIO
NS D
'INSTALLATIO
N.
8. L'ÉQU
IPEMEN
T PEUT ÊTR
E INSTALLÉ D
ANS LE M
UR
DE LIM
ITE ENTR
E UN
E ZON
E 0 ET LA ZO
NE M
OIN
S DAN
GER
EUSE, ZO
NE 1. D
ANS C
ETTE CO
NFIG
UR
ATION
, LA CO
NN
EXION
DU
PRO
CESSU
S EST INSTALLEE
DAN
S UN
E ZON
E 0, LOR
SQU
E LE BOITIER
DE L'EM
ETTEUR
EST INSTALLE D
ANS U
NE ZO
NE D
E LA ZON
E 1. 9. LA TEM
PERATU
RE C
LASSE APPLICABLE D
E L'ÉQU
IPEMEN
T , TEMPER
ATUR
E AMBIAN
TE RAN
GE,
ET MAXIM
UM
PRO
CESSU
S TEMPER
ATUR
E DE L'APPAR
EIL EST CE Q
UI SU
IT ; T3 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +150°C
T4 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +135°C T5 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +100°C
T6 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +85°C AM
BIE NT TEM
PERATU
RE R
ANG
E -40°CTa+71°C 10.LO
RS D
U M
ON
TAGE SU
R U
NE JAU
GE D
E NIVEAU
MAG
NÉTIQ
UE, ASSU
REZ-VO
US Q
UE LA TÊTE ÉLEC
TRO
NIQ
UE ET LA PR
ESSION
BARR
IÈRE A U
N ESPAC
EMEN
T MIN
IMU
M D
E 5 POU
CES. VO
IR LE M
ANU
EL D'IN
STALLATION
POU
R D
ETAIL11.C
HEM
IN D
E FLAMM
E NE SO
NT PAS À R
ÉPARER
(ACP) INSTALLATION DWG LP ANALOG
EXPLOSION PROOF CANADA
Level Plus® CHAMBEREDManual de operação
I 42 I
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
EC
O #
DESC
RIP
TION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LES
S OTH
ER
WISE
SPEC
IFIED
TOLER
ANC
ES0 P
LACE
SM
M1 PLA
CE
MM
AN
GLE
S
0.5
0.1
- THR
EA
D D
EP
THS
AR
E TO
MIN
. FULL TH
DS
- DR
ILL DE
PTH
S A
RE
TO FU
LL DIA
.- R
EM
OV
E B
UR
RS
AN
D S
HA
RP
ED
GE
S- D
O N
OT S
CA
LE P
RIN
T- M
AC
HIN
ED
SU
RFA
CE
FINIS
H 3.2uM
[125 uIn]
PRO
PRIETA
RY D
ATA
THE
INFO
RM
ATIO
N A
ND
DE
SIG
N(S
) DIS
CLO
SE
DH
ER
EIN
AR
E TH
E P
RO
PE
RTY
OF M
TS S
YS
TEM
SC
OR
PO
RA
TION
AN
D M
AY
NO
T BE
US
ED
,R
EP
RO
DU
CE
D O
R D
ISC
LOS
ED
IN A
NY
FOR
ME
XC
EP
T AS
GR
AN
TED
IN W
RITIN
G B
Y M
TSS
YS
TEM
S C
OR
PO
RA
TION
. THIS
RE
STR
ICTIO
NE
XC
LUD
ES
INFO
RM
ATIO
N TH
AT IS
IN TH
E
PU
BLIC
DO
MA
IN O
R W
AS
LEG
ITIMA
TELY
IN TH
EP
RIO
R P
OS
SE
SS
ION
OF TH
E R
EC
IPIE
NT.
mM
TS SYS
TEMS
CO
RP
OR
ATIO
NS
ENSO
RS D
IVISIO
N3001 SH
ELDO
N D
RIVE
, CA
RY, N
C 27513
METRIC
FIRST
ANG
LED
651552-2A
1
3 D
RAW
N BY:
MS
***NO
RE
VISION
S SHALL BE
MA
DE
WITH
OU
T THE
NO
TIFICA
TION
TO A
PPRO
VAL AG
EN
CY(S).***
AM
S10/24/14
RELEASE TO PRO
DU
CTION
EARTH G
ROU
ND
Rx /Tx-
Rx /Tx+
EARTH G
ROU
ND
COM
MO
N-
24 VDC
EPL Ga
EPL Gb
SEE NO
TE 8
NO
N H
AZARDO
US LO
CATION
HAZARD
OU
S LOCATIO
N
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(CAN
ADA). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
EARTH TERM
INAL
(ACP) INSTALLATIO
N D
WG
LP DIG
ITAL EXPLO
SION
PROO
F CANAD
A
7957
LEVEL
FM
APPROVED
C
N/A
EXPLOSIO
N PRO
OF
CL. I, DIV. 1, G
R. BCD T6...T3
Ex db IIB+H
2 T6...T3 Ga/G
bTa =
-40°C to +71°C ; IP65
FM CAN
ADA- FM
16CA0130XN
OTES:
1.ALL NATIO
NAL AN
D LO
CAL C
OD
ES AN
D R
EGU
LATION
S MU
ST BE AD
HER
ED TO
WH
EN IN
STALLING
THE LEVEL SEN
SOR
IN H
AZARD
OU
S ENVIR
ON
ME
NTS.
FOR
ZON
E INSTALLATIO
NS, A SEAL SH
ALL BE INSTALLED
WITH
IN 50m
m O
F THE
ENC
LOSU
RE. FO
R D
IVISION
INSTALLATIO
NS, A SEAL SH
ALL BE INSTALLED
WITH
IN 18 IN
CH
ES O
F THE EN
CLO
SUR
E.
2.DU
AL-CAVITY EN
CLO
SUR
ES: C
USTO
ME
R C
ON
NE
CTIO
NS W
ILL BE MAD
E AT TERM
INAL BLO
CK O
N PO
WER
SIDE
OF H
OU
SING
(NO
T TO TER
MIN
AL BLOC
K ON
INTER
CO
NN
ECT BO
ARD
). SEE FIGU
RE 2 O
N PAG
E 2
3. CAU
TION
: FLEXIBLE GAU
GES H
AVE A MIN
IMU
M BEN
D R
ADIU
S OF 381m
m(15")
4.WAR
NIN
G: TO
PR
EVEN
T IGN
ITION
OF FLAM
MA
BLE OR
CO
MBU
STIBLE ATM
OSPH
ERES,
DISC
ON
NE
CT PO
WER
BEFOR
E SER
VICIN
G
5.WAR
NIN
G: TH
E EQU
IPMEN
T CO
NTAIN
S NO
N-M
ETALLIC EN
CLO
SUR
E AND
PRO
CESS PAR
TS, TO PR
EVENT
THE R
ISK O
F ELECTR
OSTATIC
SPARKIN
G. TH
E NO
N-M
ETALLIC
SUR
FACE AN
D PR
OC
ESS PARTS SH
OU
LD O
NLY
BE C
LEAN
ED W
ITH A D
AMP
CLO
TH. PAIN
TED SU
RFACE OF TH
E EQU
IPMEN
T MAY STO
RE ELECTROSTATIC CH
ARGE
AND
BECOM
E A SOU
RCE OF IG
NITIO
N IN
APPLICATION
S WITH
A LOW
RELATIVE HU
MID
ITY <~
30% RELATIVE
HU
MID
ITY WH
ERE THE PAIN
TED SU
RFACE IS RELATIVELY FREE OF SU
RFACE CO
NTAM
INATIO
N SU
CH AS D
IRT, DU
ST OR
OIL. CLEAN
ING
OF TH
E PAINTED
SURFACE SH
OU
LD O
NLY BE D
ON
E W
ITH A D
AMP CLO
TH.
6. CAB
LES SH
ALL BE
RATED
> 5C ABO
VE MAXIM
UM
AMBIEN
T TEMPER
ATUR
E. 7. TO
MAIN
TAIN TH
E ING
RESS PR
OTEC
TION
RATIN
G O
F IP65, TEFLON
TAPE (3 WR
APS) O
R PIPE D
OPE SH
ALL B
E USE
D. R
EFER TO
INSTALLATIO
N IN
STRU
CTIO
NS.
8. THE EQ
UIPM
ENT C
AN BE IN
STALLED IN
THE BO
UN
DAR
Y WALL BETW
EEN A
ZON
E 0 AREA AN
D TH
E LE
SS HAZAR
DO
US AR
EA, ZON
E 1. IN TH
IS CO
NFIG
UR
ATION
, THE PR
OC
ESS CO
NN
ECTIO
N IS IN
STALLED
IN
A ZON
E 0 AR
EA, WH
ILE THE TR
ANSM
ITTER H
OU
SING
IS INSTALLED
IN A ZO
NE
1 AR
EA. 9. TH
E APPLICABLE TEM
PER
ATUR
E CLASS O
F THE EQ
UIPM
ENT, AM
BIENT TEM
PER
ATUR
E RAN
GE,
AN
D M
AXIMU
M PR
OC
ESS TEM
PER
ATUR
E OF TH
E EQU
IPMEN
T IS AS FOLLO
WS;
T3 WITH
PRO
CE
SS TEMPER
ATUR
E RAN
GE O
F -40°C to +150°C
T4 WITH
PRO
CE
SS TEMPER
ATUR
E RAN
GE O
F -40°C to +135°C
T5 WITH
PRO
CE
SS TEMPER
ATUR
E RAN
GE O
F -40°C to +100°C
T6 WITH
PRO
CE
SS TEMPER
ATUR
E RAN
GE O
F -40°C to +85°C
AM
BIE
NT TEM
PERATU
RE R
AN
GE -40°C Ta+71°C
10. WH
EN
MO
UN
TING
ON
A MAG
NE
TIC LE
VEL G
AUG
E M
AKE
SUR
E TH
E ELE
CTR
ON
IC H
EAD
AN
D P
RES
SUR
E
BA
RR
IER H
AVE A
MIN
IMU
M S
PAC
ING
OF 5 IN
CH
ES. SE
E INSTALLATIO
N M
ANU
AL FO
R D
ETA
IL11. FLAM
EP
ATHS
ARE
NO
T FOR
RE
PAIR
CON
DU
IT
CON
DU
IT SEAL
SEE NO
TE 1
CON
DU
IT SEAL
5" [127mm
] Minim
um
Fig. 47: À prova de explosão, diagrama de instalação FMC, HART®, Página 1
Level Plus® CHAMBEREDManual de operação
I 43 I
DETAIL F
SCALE 1.60 : 1
DETAIL G
SCALE 3 : 1
DETAIL H
SCALE 1.2
F
G
H
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD D
EPTHS AR
E TO M
IN. FU
LL THD
S- D
RILL D
EPTHS AR
E TO FU
LL DIA.
- REM
OVE BU
RR
S AND
SHAR
P EDG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE FIN
ISH 3.2uM
[125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIGN
(S) DISC
LOSED
HER
EIN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RA TIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN AN
Y FOR
MEXC
EPT AS GR
ANTED
IN W
RITIN
G BY M
TSSYSTEM
S CO
RPO
RATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THAT IS IN
THE
PUBLIC
DO
MAIN
OR
WAS LEG
ITIMATELY IN
THE
PRIO
R PO
SSESSION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651552-2A
2
3 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***A
MS
10/24/14RELEASE TO
PROD
UCTIO
N
+24V GNDEARTHTX/RX+TX/RX-
GND
+24V
TX/RX-
TX/RX+
EARTH
FIGU
RE 1
SING
LE CAVITY
FIGU
RE 2
DU
AL CAVITY H
OU
SING
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: FO
R ZO
NE IN
STALLATION
S, A SEAL SHALL BE IN
STALLED W
ITHIN
50mm
OF TH
E EN
CLO
SUR
E. FOR
DIVISIO
N IN
STALLATION
S, A SEAL SHALL BE IN
STALLED W
ITHIN
18 INC
HES O
F THE EN
CLO
SUR
E.
(ACP) INSTALLATIO
N D
WG
LP DIG
ITAL EXPLO
SION
PROO
F CANAD
A
+24V GND EARTH Tx/Rx+ Tx/Rx-
7957
Fig. 48: À prova de explosão, diagrama de instalação FMC, HART®, Página 2
Level Plus® CHAMBEREDManual de operação
I 44 I
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
EC
O #
DESC
RIP
TION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LES
S OTH
ER
WISE
SPEC
IFIED
TOLER
ANC
ES0 P
LACE
SM
M1 PLA
CE
MM
AN
GLE
S
0.5
0.1
- THR
EA
D D
EP
THS
AR
E TO
MIN
. FULL TH
DS
- DR
ILL DE
PTH
S A
RE
TO FU
LL DIA
.- R
EM
OV
E B
UR
RS
AN
D S
HA
RP
ED
GE
S- D
O N
OT S
CA
LE P
RIN
T- M
AC
HIN
ED
SU
RFA
CE
FINIS
H 3.2uM
[125 uIn]
PRO
PRIETA
RY D
ATA
THE
INFO
RM
ATIO
N A
ND
DE
SIG
N(S
) DIS
CLO
SE
DH
ER
EIN
AR
E TH
E P
RO
PE
RTY
OF M
TS S
YS
TEM
SC
OR
PO
RA
TION
AN
D M
AY
NO
T BE
US
ED
,R
EP
RO
DU
CE
D O
R D
ISC
LOS
ED
IN A
NY
FOR
ME
XC
EP
T AS
GR
AN
TED
IN W
RITIN
G B
Y M
TSS
YS
TEM
S C
OR
PO
RA
TION
. THIS
RE
STR
ICTIO
NE
XC
LUD
ES
INFO
RM
ATIO
N TH
AT IS
IN TH
E
PU
BLIC
DO
MA
IN O
R W
AS
LEG
ITIMA
TELY
IN TH
EP
RIO
R P
OS
SE
SS
ION
OF TH
E R
EC
IPIE
NT.
mM
TS SYS
TEMS
CO
RP
OR
ATIO
NS
ENSO
RS D
IVISIO
N3001 SH
ELDO
N D
RIVE
, CA
RY, N
C 27513
METRIC
FIRST
ANG
LED
651552-2A
3
3 D
RAW
N BY:
***NO
RE
VISION
S SHALL BE
MA
DE
WITH
OU
T THE
NO
TIFICA
TION
TO A
PPRO
VAL AG
EN
CY(S).***
A
NO
TES:1. La réglem
entation doit être respectée suivant les codes locaux et nationaux LO
RS D
'INSTALLATIO
N D
U C
APTEUR
DE N
IVEAU D
ANS D
ES ENVIR
ON
NEM
ENTS D
ANG
EREU
X. PO
UR
INSTALLATIO
NS D
E ZON
E, UN
SOR
TIE EST INSTALLÉ D
ANS LES 50 m
m D
E L'ENC
EINTE.
POU
R IN
STALLATION
S DE D
IVISION
ALE SOR
TIE EST INSTALLÉ D
ANS LES 18 PO
UC
ES DE L'EN
CEIN
TE2. EN
CEIN
TES à cavité double : Les raccordements clients, seront effectués au bornier d'alim
entation sur le côté du LOG
EMEN
T boîtier (pas au bornier carte d'interconnexion) 3. ATTEN
TION
: LES INSTR
UM
ENTS FLEXIBLES AVEC
UN
RAD
IOD
E MIN
IMU
M D
E 381mm
(15 ")4. ATTEN
TION
: Pour éviter l'inflamm
ation d'atmosphères inflam
mables ou com
bustibles, D
ÉBRAN
CH
EZ L'ALIMEN
TATION
AVANT D
'INTER
VENIR
5. AVERTISSEM
ENT: L'ÉQ
UIPEM
ENT C
ON
TENU
E DES PIÈC
ES ET PRO
CÉD
ÉS NO
N-M
ETALLIQU
ES POU
R PR
ÉVENIR
LE RISQ
UE D
'ÉCLAIR
AGE ÉLEC
TRO
STATIQU
E. LA SUR
FACE ET LES PIÈC
ES DE PR
OC
ÉDU
RE N
ON
MÉTALLIQ
UES D
OIVEN
T SEULEM
ENT
EFFECTEZ U
N PAN
NEAU
DE PLAISIR
. LA SUR
FACE PEIN
TÉE DE L'ÉQ
UIPEM
ENT PEU
T CO
NSER
VER LE C
HAR
GE ÉLEC
TRO
STATIQU
E ET D
EVENIR
UN
E SOU
RC
E D'ALLU
MAG
E DAN
S DES APPLIC
ATION
S AVEC U
NE H
UM
IDITÉ BASSE R
ELATIVE <~ 30% R
ELATIVE H
UM
IDITE O
Ù LA SU
RFAC
E PEINTU
RE EST R
ELATIVEMEN
T LIBRE D
E CO
NTAM
INATIO
N D
E SUR
FACE
TELS QU
E LA VIAND
E, LA POU
SSIÈRE O
U L'H
UILE. LE N
ETTOYAG
E DE LA SU
RFAC
E PEINTU
RE D
OIT ÊTR
E FAIT AVEC
UN
PANN
EAU D
E PLAISIR.
6. CABLES doit être évalué> 5C
DESSU
S MAXIM
UM
TEMPER
ATUR
E AMBIAN
TE.7. PO
UR
MAIN
TENIR
LA NO
TATION
DE PR
OTEC
TION
DE IN
GR
ESS IP65, du ruban téflon (3 BAND
ES) ou PIPE DO
PE DEVR
A ÊTRE U
TILISÉ. CO
NSU
LTER LES IN
STRU
CTIO
NS D
'INSTALLATIO
N.
8. L'ÉQU
IPEMEN
T PEUT ÊTR
E INSTALLÉ D
ANS LE M
UR
DE LIM
ITE ENTR
E UN
E ZON
E 0 ET LA ZO
NE M
OIN
S DAN
GER
EUSE, ZO
NE 1. D
ANS C
ETTE CO
NFIG
UR
ATION
, LA CO
NN
EXION
DU
PRO
CESSU
S EST INSTALLEE
DAN
S UN
E ZON
E 0, LOR
SQU
E LE BOITIER
DE L'EM
ETTEUR
EST INSTALLE D
ANS U
NE ZO
NE D
E LA ZON
E 1 9. LA TEM
PERATU
RE C
LASSE APPLICABLE D
E L'ÉQU
IPEMEN
T , TEMPER
ATUR
E AMBIAN
TE RAN
GE,
ET MAXIM
UM
PRO
CESSU
S TEMPER
ATUR
E DE L'APPAR
EIL EST CE Q
UI SU
IT ; T3 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +150°C
T4 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +135°C T5 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +100°C
T6 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +85°C AM
BIENT TEM
PERATU
RE R
ANG
E -40°CTa+71°C10.LO
RS D
U M
ON
TAGE SU
R U
NE JAU
GE D
E NIVEAU
MAG
NÉTIQ
UE, ASSU
REZ-VO
US Q
UE LA TÊTE ÉLEC
TRO
NIQ
UE ET LA PR
ESSION
BARR
IÈRE A U
N ESPAC
EMEN
T MIN
IMU
M D
E 5 POU
CES. VO
IR LE M
ANU
EL D'IN
STALLATION
POU
R D
ETAIL11.C
HEM
IN D
E FLAM
ME N
E SO
NT PA
S À R
ÉPAR
ER
7957RELEASE FO
R PROD
UCTIO
N
(ACP) INSTALLATIO
N D
WG
LP DIG
ITAL EXPLO
SION
PRO
OF CAN
ADA
Fig. 49: À prova de explosão, diagrama de instalação FMC, HART®, Página 3
Level Plus® CHAMBEREDManual de operação
I 45 I
13.5 ATEX e IECEx
13.5.1 Intrinsecamente seguro
13.5.1.1 Condições especificas de uso seguro
1. O gabinete do aparelho contém alumínio e é considerado um risco potencial de incêndio por impacto ou atrito. Tome cuidado durante a instalação e evitar o impacto ou o atrito. (Quando instalado em uma aprovação Ga).
2. A temperatura ambiente máxima permitida do transmissor de nível digital/analógica Level Plus® é de 71 °C. Para evitar os efeitos da temperatura do processo e outros efeitos térmicos, tome cuidado para assegurar que o ambiente ao redor e dentro do invólucro do transmissor não exceda 71 °C.
3. Alguns modelos contêm um gabinete com partes não metálicas para evitar o risco de faíscas por eletrostática, a superfície não metálica deve ser limpa somente com um pano úmido.
13.5.1.2 Etiquetas
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES
0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE 551629-3 B
1 2
DRAWN BY: NJ
A NJ
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
WARNING: REFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGS
FM14ATEX0068XIECEx FMG 14.0032X II 1/2 G Ex ia IIC T4 Ga/Gb Ta = -50°C to +71°C ; IP65when connected in accordancewith FM approved installation drawing # 651543-3
MTS Systems CorporationSensors Division3001 Sheldon Dr.Cary, NC 27513
Model No: Serial No: Date :
USE MTS LOGO ARTWORK
10 POINT SIZE
8 POINT TEXT SIZE
4.5 POINT TEXT SIZE
MTS TO PRINTMODEL NO.SERIAL NO.
DATE CODE.
ENTITY PARAMETERS:SEE PRINT REFERENCE CHART
LEVEL
1:1
7570 RELEASE TO PRODUCTION
(ACP) LABEL, LP, IS ATEX/IECEx - DIGITAL
10/24/14
1725
Level Plus Transmitter
P/N 551629-3 Rev B
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES.3. MATERIAL: 3M 7883 METALLIZED POLYESTER FOIL W/GAS RESISTANT INK.
R3.30 [.13]
1.78 [.07]
1.78 [.07]
28.70 [1.13]
15.80 [.62]
34.69 [1.37]
86.30 [3.40]
69.85 [2.75]
IP RATING WAS 66 1/19/15NJ7847B
®
1
1
2
2
A A
B B
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE: SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551705- C
1 1DRAWN BY: NJ
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
II 1/2 G Ex ia IIC T4 Ga/GbTa = -50°C TO +71°C ; IP65WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETYREFER TO INSTALLATION DRAWING FOR CAUTION/WARNING.
INSTALL PER DRAWING # 651544-3SUPPLY VOLTAGE: 28 VDC
FM14ATEX0068XIECEx FMG 14.0032X
35.05 [1.38]
"L1"∆ "L2"
17.53 [.69]
7.5 POINT SIZE
USE MTS LOGO ARTWORK14.0 POINT SIZE
MTS TO PRINTMODEL NO.
SERIAL NO./DATE CODE
"D1"
4.0 POINT TEXT SIZE(TYP.)
12.70 [.50] 3.70 [.15]
(ACP) LABEL, LP, IS ATEX/IECEx - ANALOG
R
1725
Level Plus Transmitter
P/N 551705-X Rev C
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. MATERIAL TO BE SCREEN PRINTED ALUMINUM WITH SATIN BACKGROUND AND BLACK TEXT OR LASER ETCHED ALUMINUM.3. ∆ INDICATES CRITICAL DIMENSIONS.4. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES5. MATERIAL: .8 [.03] THICK ALUMINUM6. REFER TO TABLE 1 FOR "L1" & "L2" DIMENSIONS.
LEVEL
1:1
SEE TABLE 1 FOR DASH #.
TABLE 1
DASH # HOUSING "L1" "L2" "D1"
-1 ADALET85.85 [3.38]
69.85 [2.75]
Ø2.35 [.09]x2
-2 LIMATHERM 65 [2.56] 58 [2.28] Ø 3.05 [.12] x2
C 8256 ADDED "D1" MS 2/22/1766 SAW GNITAR PI7487B NJ 12/2/14
A 7570 RELEASE FOR PRODUCTION NJ 10/24/14ETADYBNOITPIRCSED#OCEVER
1
1
2
2
A A
B B
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE: SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551703- C
1 1DRAWN BY: NJ
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
II 1/2 G Ex ia IIC T4 Ga/GbTa = -50°C TO +71°C ; IP65WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETYREFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGS
INSTALL PER DRAWING # 651543-3SUPPLY VOLTAGE: 28 VDC
FM14ATEX0068XIECEx FMG 14.0032X
35.05 [1.38]
"L1"∆ "L2"
17.53 [.69]
7.5 POINT SIZE
USE MTS LOGO ARTWORK14.0 POINT SIZE
MTS TO PRINTMODEL NO.
SERIAL NO./DATE CODE
"D1"
4.0 POINT TEXT SIZE(TYP.)
12.70 [.50] 3.70 [.15]
(ACP) LABEL, LP, IS ATEX/IECEX - DIGITAL
R
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. MATERIAL TO BE SCREEN PRINTED ALUMINUM WITH SATIN BACKGROUND AND BLACK TEXT OR LASER ETCHED ALUMINUM.3. ∆ INDICATES CRITICAL DIMENSIONS.4. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES5. MATERIAL: .8 [.03] THICK ALUMINUM6. REFER TO TABLE 1 FOR "L1" & "L2" DIMENSIONS.
1725
Level Plus Transmitter
P/N 551703-X Rev C
1:1LEVEL
SEE TABLE 1 FOR DASH #.
TABLE 1
DASH # HOUSING "L1" "L2" "D1"
-1 ADALET85.85 [3.38]
69.85[2.75]
Ø2.35 [.09]x2
-2 LIMATHERM 65 [2.56] 58 [2.28] Ø 3.05 [.12] x2
C 8256 ADDED "D1" MS 2/22/1766 SAW GNITAR PI7487B NJ 12/2/14
A 7570 RELEASE FOR PRODUCTION NJ 10/24/14ETADYBNOITPIRCSED#OCEVER
Fig. 50: Etiqueta FMC intrinsecamente segura, Modbus e DDA, invólucro NEMA
Fig. 51: Etiqueta ATEX/IECEx intrinsecamente segura, Modbus e DDA, invólucro NEMA
Fig. 52: Etiqueta ATEX/IECEx intrinsecamente segura, Modbus e DDA, invólucro com cavidade única ou dupla
Fig. 53: Etiqueta ATEX/IECEx intrinsecamente segura, Modbus e DDA, invólucro com cavidade única ou dupla
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES
0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE 551629-3 B
1 2
DRAWN BY: NJ
A NJ
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
WARNING: REFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGS
FM14ATEX0068XIECEx FMG 14.0032X II 1/2 G Ex ia IIC T4 Ga/Gb Ta = -50°C to +71°C ; IP65when connected in accordancewith FM approved installation drawing # 651543-3
MTS Systems CorporationSensors Division3001 Sheldon Dr.Cary, NC 27513
Model No: Serial No: Date :
USE MTS LOGO ARTWORK
10 POINT SIZE
8 POINT TEXT SIZE
4.5 POINT TEXT SIZE
MTS TO PRINTMODEL NO.SERIAL NO.
DATE CODE.
ENTITY PARAMETERS:SEE PRINT REFERENCE CHART
LEVEL
1:1
7570 RELEASE TO PRODUCTION
(ACP) LABEL, LP, IS ATEX/IECEx - DIGITAL
10/24/14
1725
Level Plus Transmitter
P/N 551629-3 Rev B
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES.3. MATERIAL: 3M 7883 METALLIZED POLYESTER FOIL W/GAS RESISTANT INK.
R3.30 [.13]
1.78 [.07]
1.78 [.07]
28.70 [1.13]
15.80 [.62]
34.69 [1.37]
86.30 [3.40]
69.85 [2.75]
IP RATING WAS 66 1/19/15NJ7847B
®
651544-3
551641-3
Level Plus® CHAMBEREDManual de operação
I 46 I
13.5.1.3 Diagrama de instalação
Fig. 54: Diagrama de instalação ATEX / IECEx intrinsecamente segura, Modbus e DDA, Página 1
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651543-3
1 2
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
24 VDC
COMM
ON- >
Rx/Tx+
Rx/Tx -
GROUND
EARTH GROUND(SEE NOTE 4)
EARTH GROUND(SEE NOTE 4)
Rx/Tx-
Rx/Tx+
GND
+24V
SAFETY BARRIER SAFETY BARRIER
SAFETY BARRIER
NO
TES:1.ALL N
ATION
AL AND
LOC
AL CO
DES AN
D R
EGU
LATION
S MU
ST BE ADH
ERED
TO W
HEN
INSTALLIN
G TH
E LEVEL SENSO
R IN
HAZAR
DO
US EN
VIRO
NM
ENTS.
SEAL ALL CO
ND
UITS W
ITHIN
457 MM
(18"). 2.LO
OP C
ABLE MU
ST BE 24 AWG
TO 14 AW
G (.511M
M² to 1.6M
M²)
SHIELD
ED TW
ISTED PAIR
CABLE W
ITH SH
IELD. C
ABLE CAPAC
ITANC
E MU
ST BE LESS TH
AN 30 pF PER
FOO
T (98 pF PER M
). CABLE SH
IELD IS C
ON
NEC
TED TO
SYSTEM G
RO
UN
D IN
NO
N-H
AZARD
OU
S AREA. SEE IN
STALLATION
MAN
UAL FO
R
ADD
ITION
AL CABLE IN
FOR
MATIO
N.
3.THE R
ESISTANC
E BETWEEN
EARTH
GR
OU
ND
AND
THE IN
TRIN
SICALLY SAFE G
RO
UN
D M
UST BE LESS TH
AN 1 O
HM
. 4.TH
E TRAN
SDU
CER
FRAM
E SHALL BE G
RO
UN
DED
TO EAR
TH G
RO
UN
D D
IREC
TLY OR
THR
OU
GH
THE EQ
UIPM
ENT O
N W
HIC
H IT IS M
OU
NTED
. 5. C
ON
TRO
L EQU
IPMEN
T CO
NN
ECTED
TO ASSO
CIATED
APPARATU
S MU
ST N
OT U
SE OR
GEN
ERATE M
OR
E THAN
250 VRM
S OR
VDC
6.ASSOC
IATED APPAR
ATUS M
ANU
FACTU
RER
'S INSTALLATIO
N D
RAW
ING
MU
ST BE FO
LLOW
ED W
HEN
INSTALLIN
G TH
IS EQU
IPMEN
T. 7.O
NLY U
SE ATEX/IEC APPR
OVED
BARR
IERS.
8.ENTITY PAR
AMETER
S: SU
PPLY: Rx/Tx-: R
x/Tx+: U
i = 28VDC
Ui= 8.6V U
i= 8.6V Ii = 100m
A Ii = 10mA Ii = 10m
A C
i = 0 µF Ci = 0 µF C
i = 0 µF Li = 0 µH
Li = 0 µH Li = 0 µH
Pi = 0.7 W Pi= 0.0215 W
P i= 0.0215 W 9.TH
E ENTITY C
ON
CEPT ALLO
WS IN
TERC
ON
NEC
TION
OF IN
TRIN
SICALLY SAFE APPAR
ATUS
WITH
ASSOC
IATED APPAR
ATUS W
HEN
THE FO
LLOW
ING
IS TRU
E: Vm
ax or Ui ≥ Voc, Vt or U
o; Im
ax or Ii ≥ Isc, It or Io; Pm
ax or Pi ≥ Po; C
a ≥ Ci + C
cable; La ≥ Li + Lcable. 10.D
UAL-C
AVITY ENC
LOSU
RES:
CU
STOM
ER C
ON
NEC
TION
S WILL BE M
ADE AT TER
MIN
AL BLOC
K ON
POW
ER SID
E O
F HO
USIN
G (N
OT TO
TERM
INAL BLO
CK O
N IN
TERC
ON
NEC
T BOAR
D).
11.FOR INSTALLATION WITHIN THE EUROPEAN UNION, SEE EN 60079-14.
12.THE M
AXIMU
M PER
MITTED
AMBIEN
T TEMPER
ATUR
E OF TH
E LEVEL PLUS D
IGITAL/AN
ALOG
LEVEL TR
ANSM
ITTER IS 71 °C
. TO AVO
ID TH
E EFFECTS O
F PRO
CESS TEM
PERATU
RE AN
D
OTH
ER TH
ERM
AL EFFECTS C
ARE SH
ALL BE TAKEN TO
ENSU
RE TH
E SUR
RO
UN
DIN
G AM
BIENT
AND
THE AM
BIENT IN
SIDE TH
E TRAN
SMITTER
HO
USIN
G D
OES N
OT EXC
EED 71°C
13.CAU
TION
: FLEXIBLE GAU
GES H
AVE A MIN
IMU
M BEN
D R
ADIU
S OF 381M
M(15")
14.WAR
NIN
G: TH
E APPARATU
S ENC
LOSU
RE C
ON
TAINS ALU
MIN
UM
AND
IS CO
NSID
ERED
TO C
ON
STITUTE A PO
TENTIAL R
ISK OF IG
NITIO
N BY IM
PACT O
R FR
ICTIO
N. C
ARE M
UST BE TAKEN
IN
TO AC
CO
UN
T DU
RIN
G IN
STALLATION
AND
USE TO
PREVEN
T IMPAC
T OR
FRIC
TION
15.WAR
NIN
G: SU
BSTITUTIO
N O
F CO
MPO
NEN
TS MAY IM
PAIR IN
TRIN
SIC SAFETY.
16.WAR
NIN
G: TO
PREVEN
T IGN
ITION
OF FLAM
MABLE O
R C
OM
BUSTIBLE ATM
OSPH
ERES,
DISC
ON
NEC
T POW
ER BEFO
RE SER
VICIN
G
17.WAR
NIN
G: TH
E EQU
IPMEN
T CO
NTAIN
S NO
N-M
ETALLIC EN
CLO
SUR
E PARTS, TO
PREVEN
T TH
E RISK O
F ELECTR
OSTATIC
SPARKIN
G. TH
E NO
N-M
ETALLIC SU
RFAC
E SHO
ULD
ON
LY BE C
LEANED
WITH
A DAM
P CLO
TH.
NON HAZARDOUS LOCATIONHAZARDOUS LOCATION
INTR
INSIC
ALLY SAFEFM
14ATEX0068XIEC
Ex FMG
14.0032X
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(ATEX/IEC). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
EARTH TERMINAL
(ACP) INSTALLATIN DWG LP DIGITAL
INTRINSICALLY SAFE FOR ATEX/IEC
7570
LEVELN/A
1725
II 1/2 G Ex ia T4 Ga/GbTa =
-50 TO 71°C; IP65
Level Plus® CHAMBEREDManual de operação
I 47 I
Fig. 55: Diagrama de instalação ATEX / IECEx intrinsecamente segura, Modbus e DDA, Página 2
DETAIL ASCALE 1.60 : 1
DETAIL CSCALE 3 : 1
DETAIL DSCALE 1.2
DETAIL ESCALE 1 : 1
A
C
D
E
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651543-3
2 2
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
+24V GNDEARTHTX/RX+TX/RX-
GND+24V
TX/RX-TX/RX+EARTH
GND+24V
TX/RX-
TX/RX+
EARTH
FIGU
RE 1
SING
LE CAVITY & N
EMA H
OU
SING
FIGU
RE 2
DU
AL CAVITY H
OU
SING
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: C
ON
DU
IT SEALS REQ
UIR
ED W
ITHIN
457 MM
(18") OF H
OU
SING
.
(ACP) INSTALLATIN DWG LP DIGITAL
INTRINSICALLY SAFE FOR ATEX/IEC
+24V GND EARTH Tx/Rx+ Tx/Rx-
7570
WIRING CHART (FOR NEM
A GAUGE)
PIN WIRING CHART (FOR NEM
A GAUGE)
WIRE COLOR
SIGNALRED
24 V PWR
BLACK 0 V PW
RBLUE
N/AW
HITERX TX +
GREENRX TX -
DRAIN WIRE
EARTH GROUND
PIN #SIGNAL
PIN 124 V PW
RPIN 2
0 V PWR
PIN 3N/A
PIN 4RX TX+
PIN 5RX TX-
PIN 6EARTH GROUND
Level Plus® CHAMBEREDManual de operação
I 48 I
Fig. 56: Diagrama de instalação ATEX / IECEx intrinsecamente segura, HART®, Página 1
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651544-3LEVEL
1 2
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
NO
N H
AZARD
OU
S LOC
ATION
HAZAR
DO
US LO
CATIO
N
NO
TES: 1. ALL N
ATION
AL AND
LOC
AL CO
DES AN
D R
EGU
LATION
S MU
ST BE ADH
ERED
TO W
HEN
INSTALLIN
G TH
E MTS LP SEN
SOR
IN H
AZARD
OU
S ENVIR
ON
MEN
TS. SEAL ALL C
ON
DU
ITS WITH
IN 457 M
M (18").
2. LOO
P CABLE M
UST BE 24 AW
G TO
14 AWG
(.511MM
² to 1.6MM
²) SH
IELDED
TWISTED
PAIR C
ABLE WITH
SHIELD
. CABLE C
APACITAN
CE M
UST
BE LESS THAN
30 pF PER FO
OT (98 pF PER
m). C
ABLE SH
IELD IS C
ON
NEC
TED TO
SYSTEM G
RO
UN
D IN
NO
N-H
AZARD
OU
S AREA. SEE IN
STALLATION
MAN
UAL FO
R
ADD
ITION
AL CABLE IN
FOR
MATIO
N.
3. THE R
ESISTANC
E BETWEEN
EARTH
GR
OU
ND
AND
THE IN
TRIN
SICALLY SAFE G
RO
UN
D M
UST BE LESS TH
AN 1 O
HM
. 4. TH
E TRAN
SDU
CER
FRAM
E SHALL BE G
RO
UN
DED
TO EAR
TH G
RO
UN
D D
IREC
TLY OR
THR
OU
GH
THE EQ
UIPM
ENT O
N W
HIC
H IT IS M
OU
NTED
. 5. C
ON
TRO
L EQU
IPMEN
T CO
NN
ECTED
TO ASSO
CIATED
APPARATU
S MU
ST N
OT U
SE OR
GEN
ERATE M
OR
E THAN
250 VRM
S OR
VDC.
6. ASSOC
IATED APPAR
ATUS M
ANU
FACTU
RER
'S INSTALLATIO
N D
RAW
ING
MU
ST BE FO
LLOW
ED W
HEN
INSTALLIN
G TH
IS EQU
IPMEN
T 7. O
NLY U
SE ATEX/IEC APPR
OVED
BARR
IERS.
8. APPRO
VED LO
OP SEPAR
ATION
METH
OD
S: *R
UN
LOO
PS IN SEPAR
ATE CABLES
*RU
N LO
OPS IN
SEPARATE G
RO
UN
DED
SHIELD
S 9. EN
TITY PARAM
ETERS EAC
H LO
OP:
Ui = 28 VD
C Ii = 120 m
A C
i = 0 µF Li = 5 µH Pi = 840 m
W 10. D
UAL-C
AVITY ENC
LOSU
RES:
CU
STOM
ER C
ON
NEC
TION
S WILL BE M
ADE AT TER
MIN
AL BLOC
K ON
POW
ER SID
E O
F HO
USIN
G (N
OT TO
TERM
INAL BLO
CK O
N IN
TERC
ON
NEC
T BOAR
D)
11 FOR
INSTALLATIO
N W
ITHIN
THE EU
RO
PEAN U
NIO
N, SEE EN
60079-14. 12.TH
E MAXIM
UM
PERM
ITTED AM
BIENT TEM
PERATU
RE O
F THE LEVEL PLU
S DIG
ITAL/ANALO
G
LEVEL TRAN
SMITTER
IS 71 °C. TO
AVOID
THE EFFEC
TS OF PR
OC
ESS TEMPER
ATUR
E AND
O
THER
THER
MAL EFFEC
TS CAR
E SHALL BE TAKEN
TO EN
SUR
E THE SU
RR
OU
ND
ING
AMBIEN
T AN
D TH
E AMBIEN
T INSID
E THE TR
ANSM
ITTER H
OU
SING
DO
ES NO
T EXCEED
71°C 13.C
AUTIO
N: FLEXIBLE G
AUG
ES HAVE A M
INIM
UM
BEND
RAD
IUS O
F 381MM
(15") 14. W
ARN
ING
: THE APPAR
ATUS EN
CLO
SUR
E CO
NTAIN
S ALUM
INU
M AN
D IS C
ON
SIDER
ED TO
CO
NSTITU
TE A PO
TENTIAL R
ISK OF IG
NITIO
N BY IM
PACT O
R FR
ICTIO
N. C
ARE M
UST BE TAKEN
IN
TO AC
CO
UN
T DU
RIN
G IN
STALLATION
AND
USE TO
PREVEN
T IMPAC
T OR
FRIC
TION
15.WAR
NIN
G: SU
BSTITUTIO
N O
F CO
MPO
NEN
TS MAY IM
PAIR IN
TRIN
SIC SAFETY.
16.WAR
NIN
G: TO
PREVEN
T IGN
ITION
OF FLAM
MABLE O
R C
OM
BUSTIBLE ATM
OSPH
ERES.
DISC
ON
NEC
T POW
ER BEFO
RE SER
VICIN
G.
17.WAR
NIN
G: TH
E EQU
IPMEN
T CO
NTAIN
S NO
N-M
ETALLIC EN
CLO
SUR
E PARTS, TO
PREVEN
T TH
E RISK O
F ELECTR
OSTATIC
SPARKIN
G. TH
E NO
N-M
ETALLIC SU
RFAC
E SHO
ULD
ON
LY BE C
LEANED
WITH
A DAM
P CLO
TH.
EARTH
GR
OU
ND
LUG
NO
TE 3
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(ATEX/IEC). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
24 VDC
CO
NTR
OL
INPU
T 1
CO
NTR
OL
INPU
T 2
APPRO
VED SAFETY
BARR
IER
APPRO
VED SAFETY
BARR
IER
LOO
P VOLTAG
E
SHIELD
SHIELD
LOO
P 1+
LOO
P 1-
LOO
P 2+
LOO
P 2-
(ACP) INSTALLATIN DWG LP ANALOG
INTRINSICALLY SAFE FOR ATEX/IEC
SING
LE OR
DU
AL CAVITY
NEM
A HO
USIN
G
E
II 1/2 G Ex ia T4 Ga/GbTa =
-50 TO 71°C; IP65
INTR
INSIC
ALLY SAFEFM
14ATEX0068XIEC
Ex FMG
14.0032X
1725
EARTH
GR
OU
ND
(SEE N
OTE 4)
EARTH
GR
OU
ND
(SEE N
OTE 4)
Level Plus® CHAMBEREDManual de operação
I 49 I
Fig. 57: Diagrama de instalação ATEX / IECEx intrinsecamente segura, HART®, Página 2
DETAIL D
SCALE 3
DETAIL E
SCALE 1.60
DETAIL F
SCALE 1.2
DETAIL H
SCALE 1 : 1
D
E
F
H
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651544-3LEVEL
2 2
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
LOOP 2-
LOOP 2+
EARTH
LOOP 1-
LOOP 1+
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: C
ON
DU
IT SEALS REQ
UIR
ED W
ITHIN
457 MM
(18") OF H
OU
SING
.
FIGU
RE 2
DU
AL CAVITY H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
FIGU
RE 1
SING
LE CAVITY & N
EMA H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
(ACP) IN
STALLATION
DW
G LP AN
ALGO
IN
TRIN
SICALLY SAFE ATEX/IEC
E
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
E
WIRING CHART( FOR NEM
A GAUGE)
PIN WIRING CHART (FOR NEM
A GAUGE)
WIRE COLOR
SIGNALRED
LOOP 1+BLACK
LOOP 1-BLUE
LOOP 2-W
HITELOOP 2+
GREENN/A
DRAIN WIRE
EARTH GROUND
PIN #SIGNAL
PIN 1LOOP 1-
PIN 2LOOP 1+
PIN 3LOOP 2-
PIN 4LOOP 2+
PIN 5N/A
PIN 6EARTH GROUND
Level Plus® CHAMBEREDManual de operação
I 50 I
13.5.2 À prova de explosão / à prova de chamas
13.5.2.1 Condições especificas de uso seguro
1. Aviso: O equipamento contém um gabinete não metálica e parte do processo para evitar o risco de faísca eletrostática. A superfície não metálica deve ser limpa apenas com um pano úmido. A superfície pintada do equipamento pode armazenar descarga eletrostática e tornar-se uma fonte de ignição em aplicações com umidade relativa baixa (<~30%) em que a superfície pintada é relativamente livre de contaminação da superfície como sujeiras, poeira ou óleo. A limpeza da superfície pintada deve ser feita apenas com um pano úmido.
2. Os cabos devem ter a classificação > 5 °C acima da temperatura ambiente máxima.
3. Para manter a classificação de proteção contra entrada do IP65, a fita Teflon™ (3 voltas) ou cola para canos deve ser usada. Consulte as instruções de instalação.
4. O equipamento pode ser instalado na parede em que a conexão do processo está como um equipamento Categoria 1G enquanto o involucro do transmissor está instalado como equipamento Categoria 2G. Consulte as instruções de instalação.
5. Os medidores flexíveis têm um raio de curvatura mínimo de 381 mm (15 pol.).
6. Caminho da chama não para reparo. 7. A classe de temperatura aplicável, faixa de temperatura
de processo e a faixa de temperatura ambiente do equipamento estão abaixo:• T3 com a faixa de temperatura de processo −40 °C a +150 °C • T4 com a faixa de temperatura de processo −40 °C a +135 °C• T5 com a faixa de temperatura de processo −40 °C a +100 °C• T6 com a faixa de temperatura de processo −40 °C a +85 °C• A faixa de temperatura ambiente é de −40 °C ≤ Ta ≤ 71 °C
8. Quando montar em um MLG (medidor magnético de nível), certifique-se o cabeçote eletrônico e a barreira de pressão têm um espaçamento mínimo de 5 pol. Consulte o Manual de instalação para detalhes.
Fig. 58: À prova de chamas, etiqueta ATEX e IECEx, invólucro Modbus ou DDA, opções D, E, G, H ou L
Fig. 59: À prova de chamas, etiqueta ATEX e IECEx, invólucro HART®, opções D, E, G, H ou L
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METR IC
FIRST ANGLE A 551707-X A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 2/12/18
FM16ATEX0068XIECEx FMG 16.0033X
Level Plus TransmitterMTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513 U.S.A
WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. POTENTIAL ELECTROSTATIC CHARGING HAZARD - SEE INSTRUCTIONS
MAX. PRESSURE 1000 PSI (RIGID SENSOR)MAX. PRESSURE 435 PSI (FLEX SENSOR)
INSTALL PER DRAWING # 651552-3
II 1/2 G Ex db IIB+H2 T6...T3 Ga/Gb Ta = -40°C to +71°C ; IP65 INPUT: 28V (120mA) maxOUTPUT: RS485
38.00 [1.50]
"L1"
∆ "L2"
19.00 [.75]
4.2 POINT SIZEUSE MTS LOGO ARTWORK
11.0 POINT SIZE
MTS TO PRINTMODEL NO.
REFER TO DRAWING# 280743
SERIAL NO./DATE CODE"D1"
7570 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP ATEX/IECEx - DIGITAL
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. MATERIAL TO BE SCREEN PRINTED ALUMINUM WITH SATIN BACKGROUND AND BLACK TEXT OR LASER ETCHED ALUMINUM.3. ∆ INDICATES CRITICAL DIMENSIONS.4. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES5. MATERIAL: .8 [.03] THICK ALUMINUM.6. REFER TO TABLE 1 FOR "L1" & "L2" DIMENSIONS.
1725
P/N 551707-X Rev A
1:1LEVEL
4.2 POINT TEXT SIZE(TYP.)
SEE TABLE 1 FOR DASH #.
CE LOGO TO BE 5mm MINIMUM
TABLE 1DASH
# HOUSING GROUPS "L1" "L2" "D1"
-1ADALET [403892, 403890,403889] B,C,D 85.85
[3.38]69.85 [2.75]
Ø2.35 [.09]x2
-2LIMATHERM
[403812, 403813] A,B,C,D 65 [2.56] 58 [2.28] Ø 3.05
[.12] x2
!
R
7. POINT TEXT SIZE
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES 0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METR IC
FIRST ANGLE A 551709- A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 2/12/18
FM16ATEX0068XIECEx FMG 16.0033X
Level Plus TransmitterMTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513U.S.A
II 1/2 G Ex db IIB+H2 T6...T3 Ga/Gb Ta = -40°C to +71°C ; IP65 INPUT: 28V (120mA) maxOUTPUT: 4-20mA
MAX. PRESSURE 1000 PSI (RIGID SENSOR)MAX. PRESSURE 435 PSI (FLEX SENSOR)
INSTALL PER DRAWING # 651553-3
WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. POTENTIAL ELECTROSTATIC CHARGING HAZARD - SEE INSTRUCTIONS
38.00 [1.50]
"L1"
∆ "L2"
19.00 [.75]
4.2 POINT SIZE
USE MTS LOGO ARTWORK11.0 POINT SIZE
MTS TO PRINT
MODEL NO.REFER TO DRAWING #280743
SERIAL NO./DATE CODE
"D1"
7957 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP ATEX/IECEx - ANALOG
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. MATERIAL TO BE SCREEN PRINTED ALUMINUM WITH SATIN BACKGROUND AND BLACK TEXT OR LASER ETCHED ALUMINUM.3. ∆ INDICATES CRITICAL DIMENSIONS.4. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES5. MATERIAL: .8 [0.03] THICK ALUMINUM.6. REFER TO TABLE 1 FOR "L1" & "L2" DIMENSIONS.
1725
P/N 551709- Rev A
1:1LEVEL
4.2 POINT TEXT SIZE(TYP.)
SEE TABLE 1 FOR DASH #.
CE LOGO TO BE 5mm MINIMUM
TABLE 1DASH
# HOUSING GROUPS "L1" "L2" "D1"
-1ADALET [403892, 403890,403889] B,C,D 85.85
[3.38]69.85 [2.75]
Ø2.35 [.09]x2
-2LIMATHERM
[403812, 403813] A,B,C,D 65 [2.56] 58 [2.28] Ø 3.05
[.12] x2
!
R
7. POINT TEXT SIZE
13.5.2.2 Etiquetas
Level Plus® CHAMBEREDManual de operação
I 51 I
13.5.2.3 Diagrama de instalação
Fig. 60: À prova de chamas, diagrama de instalação ATEX e IECEx, Modbus e DDA, Página 1
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651553-3B
LEVEL1
2 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***B
MS
10/22/15RELEASE TO PRODUCTION
8482UPDATED W
IRING DWG TO ANALOG
MS
5/17/18A
7957
EARTH GROUND
LOOP 2-
LOOP 2+
EARTH GROUND
LOOP 1-
LOOP 1+
NO
N H
AZARD
OU
S LOC
ATION
HAZAR
DO
US LO
CATIO
N
EARTH
GR
OU
ND
LUG
NO
TE 3
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(ATEX/IEC). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
(ACP) INSTALLATION DWG LP ANALOG
EXPLOSION PROOF ATEX/IEC
SING
LE OR
DU
AL CAVITY
1725For ATEX - FM
16ATEX0068XFor IECEx - IECEx FM
G 16.0033X
AREA R
EQU
IRIN
G
EPL Gb
AREA R
EQU
IRIN
G
EPL Ga
CO
ND
UIT JU
NC
TION
CO
ND
UIT
SEE NO
TE 1
SEE NO
TE 8
II 1/2 G Ex db IIB+H2 T6...T3 Ga/GbTa = -40°C to +71°C; IP65
CATEG
OR
Y 1
CATEG
OR
Y 2
NO
TES:1.ALL N
ATION
AL AND
LOC
AL CO
DES AN
D R
EGU
LATION
S MU
ST BE ADH
ERED
TO W
HEN
INSTALLIN
G TH
E LEVEL SENSO
R IN
HAZAR
DO
US EN
VIRO
NM
ENTS.
SEAL ALL CO
ND
UITS W
ITHIN
50mm
OF EN
CLO
SUR
E.2.D
UAL-C
AVITY ENC
LOSU
RES:
CU
STOM
ER C
ON
NEC
TION
S WILL BE M
ADE AT TER
MIN
AL BLOC
K ON
POW
ER SID
E O
F HO
USIN
G (N
OT TO
T ERM
INAL BLO
CK O
N IN
TERC
ON
NEC
T BOAR
D). SEE FIG
UR
E 2 ON
PAGE 2
3. CAU
TION
: FLEXIBLE GAU
GES H
AVE A MIN
IMU
M BEN
D R
ADIU
S OF 381m
m(15")
4.WAR
NIN
G: TO
PREVEN
T IGN
ITION
OF FLAM
MABLE O
R C
OM
BUSTIBLE ATM
OSPH
ERES,
DISC
ON
NEC
T POW
ER BEFO
RE SER
VICIN
G
5.WAR
NIN
G: TH
E EQU
IPMEN
T CO
NTAIN
S NO
N-M
ETALLIC EN
CLO
SUR
E AND
PRO
CESS PAR
TS, TO PR
EVENT
THE R
ISK OF ELEC
TRO
STATIC SPAR
KING
. THE N
ON
-METALLIC
SUR
FACE AN
D PR
OC ESS PAR
TS SHO
ULD
ON
LY BE C
LEANED
WITH
A DAM
P CLO
TH. PAINTED SURFACE OF THE EQUIPM
ENT MAY STORE ELECTROSTATIC CHARGE
AND BECOME A SOURCE OF IGNITION IN APPLICATIONS W
ITH A LOW RELATIVE HUM
IDITY <~30%
RELATIVE HUM
IDITY WHERE THE PAINTED SURFACE IS RELATIVELY FREE OF SURFACE CONTAM
INATION SUCH AS DIRT, DUST OR OIL. CLEANING OF THE PAINTED SURFACE SHOULD ONLY BE DONE W
ITH A DAMP CLOT H.
6. CABLES SH
ALL BE RATED
> 5C ABO
VE MAXIM
UM
AMBIEN
T TEMPER
ATUR
E. 7. TO
MAIN
TAIN TH
E ING
RESS PR
OTEC
TION
RATIN
G O
F IP65, TEFLON
TAPE (3 WR
APS) OR
PIPE DO
PE SHALL
BE USED
. REFER
TO IN
STALLATION
INSTR
UC
TION
S.8. TH
E EQU
IPMEN
T CAN
BE INSTALLED
IN TH
E BOU
ND
ARY W
ALL BETWEEN
AN EPL G
a AREA AN
D TH
E LESS H
AZARD
OU
S AREA, EPL G
b. IN TH
IS CO
NFIG
UR
ATION
, THE PR
OC
ESS CO
NN
ECTIO
N IS IN
STALLED
IN EPL G
a, WH
ILE THE TR
ANSM
ITTER H
OU
SING
IS INSTALLED
IN EPL G
b. REFER
TO IN
STALLATION
IN
STRU
CTIO
NS.
EQU
IPMEN
T CAN
BE INSTALLED
IN A BO
UN
DAR
Y WALL C
ON
FIGU
RATIO
N W
HER
E THE PR
OC
ESS CO
NN
ECTIO
N IS IN
STALLED AS C
ATEGO
RY 1G
EQU
IPMEN
T WH
ILE THE TR
ANSM
ITTER H
OU
SING
IS INSTALLED
AS C
ATEGO
RY 2G
EQU
IPMEN
T. REFER
TO IN
STALLATION
INSTR
UC
TION
S 9. TH
E APPLICABLE TEM
PERATU
RE C
LASS OF TH
E EQU
IPMEN
T, AMBIEN
T TEMPER
ATUR
E RAN
GE,
AND
MAXIM
UM
PRO
CESS TEM
PERATU
RE O
F THE EQ
UIPM
ENT IS AS FO
LLOW
S; T3 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +150°C
T4 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +135°C T5 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +100°C
T6 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +85°C AM
BIENT TEM
PERATU
RE R
ANG
E -40°C Ta+71°C10. W
HEN
MO
UN
TING
ON
A MAG
NETIC
LEVEL GAU
GE M
AKE SUR
E THE ELEC
TRO
NIC
HEAD
AND
PRESSU
RE
BARR
IER H
AVE A MIN
IMU
M SPAC
ING
OF 5 IN
CH
ES. SEE INSTALLATIO
N M
ANU
AL FOR
DETAIL
11. FLAMEPATH
S ARE N
OT FO
R R
EPAIR
5" [127mm
] Minim
um
Level Plus® CHAMBEREDManual de operação
I 52 I
Fig. 61: À prova de chamas, diagrama de instalação FM, Modbus e DDA
DETAIL D
SCALE 3
DETAIL E
SCALE 1.60
DETAIL F
SCALE 1.2
D
E
F
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651553-3B
LEVEL2
2 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***B
MS
10/22/15RELEASE TO PRODUCTION
8482UPDATED W
IRING DWG TO ANALOG
MS
5/17/18A
7957
LOOP 2-
LOOP 2+
EARTH
LOOP 1-
LOOP 1+
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: C
ON
DU
IT SEALS REQ
UIR
ED W
ITHIN
50mm
OF H
OU
SING
.
FIGU
RE 2
DU
AL CAVITY H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
FIGU
RE 1
SING
LE CAVITY H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
(ACP) INSTALLATION DWG LP ANALOG
EXPLOSION PROOF ATEX/IEC
Level Plus® CHAMBEREDManual de operação
I 53 I
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
EC
O #
DESC
RIP
TION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LES
S OTH
ER
WISE
SPEC
IFIED
TOLER
ANC
ES0 P
LACE
SM
M1 PLA
CE
MM
AN
GLE
S
0.5
0.1
- THR
EA
D D
EP
THS
AR
E TO
MIN
. FULL TH
DS
- DR
ILL DE
PTH
S A
RE
TO FU
LL DIA
.- R
EM
OV
E B
UR
RS
AN
D S
HA
RP
ED
GE
S- D
O N
OT S
CA
LE P
RIN
T- M
AC
HIN
ED
SU
RFA
CE
FINIS
H 3.2uM
[125 uIn]
PRO
PRIETA
RY D
ATA
THE
INFO
RM
ATIO
N A
ND
DE
SIG
N(S
) DIS
CLO
SE
DH
ER
EIN
AR
E TH
E P
RO
PE
RTY
OF M
TS S
YS
TEM
SC
OR
PO
RA
TION
AN
D M
AY
NO
T BE
US
ED
,R
EP
RO
DU
CE
D O
R D
ISC
LOS
ED
IN A
NY
FOR
ME
XC
EP
T AS
GR
AN
TED
IN W
RITIN
G B
Y M
TSS
YS
TEM
S C
OR
PO
RA
TION
. THIS
RE
STR
ICTIO
NE
XC
LUD
ES
INFO
RM
ATIO
N TH
AT IS
IN TH
E
PU
BLIC
DO
MA
IN O
R W
AS
LEG
ITIMA
TELY
IN TH
EP
RIO
R P
OS
SE
SS
ION
OF TH
E R
EC
IPIE
NT.
mM
TS SYS
TEMS
CO
RP
OR
ATIO
NS
ENSO
RS D
IVISIO
N3001 SH
ELDO
N D
RIVE
, CA
RY, N
C 27513
METRIC
FIRST
ANG
LED
651552-3A
1
2 D
RAW
N BY:
MS
***NO
RE
VISION
S SHALL BE
MA
DE
WITH
OU
T THE
NO
TIFICA
TION
TO A
PPRO
VAL AG
EN
CY(S).***
AM
S10/24/14
RELEASE TO PRO
DU
CTION
EARTH G
ROU
ND
24 VDC
COM
MO
N-
Rx /Tx+
Rx /Tx-
EARTH G
ROU
ND
CATEGO
RY 1
CATEGO
RY 2
NO
N H
AZARDO
US LO
CATION
HAZARD
OU
S LOCATIO
N
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(ATEX/IEC). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
EARTH TERM
INAL
(ACP) INSTALLATIN
DW
G LP D
IGITAL
EXPLOSIO
N PRO
OF ATEX/IEC
7957
LEVEL
N/A
1725II 1/2 G
Ex db IIB+
H2 T6...T3 G
a/Gb
Ta = -40°C to +
71°C; IP65
For ATEX - FM16ATEX0068X
For IECEx - IECEx FMG 16.0033X
AREA REQ
UIRIN
GEPL G
b
AREA REQU
IRING
EPL Ga
NO
TES:
1.ALL NA
TION
AL AND
LOC
AL CO
DES AN
D R
EGU
LATION
S MU
ST BE ADH
ERE
D TO
WH
EN
INSTALLIN
G TH
E LEVEL SEN
SOR
IN H
AZARD
OU
S ENVIR
ON
MEN
TS. SEAL ALL C
ON
DU
ITS WITH
IN 50m
m O
F ENC
LOSU
RE.
2.DU
AL-CAV
ITY ENC
LOSU
RES:
CU
STOM
ER C
ON
NEC
TION
S WILL BE
MAD E AT TER
MIN
AL BLOC
K ON
POW
ER SID
E O
F HO
USIN
G (N
OT TO
TERM
INAL BLO
CK O
N IN
TERC
ON
NEC
T BOAR
D). SEE FIG
UR
E 2 ON
PAGE 2
3. CA
UTIO
N: FLEXIBLE G
AUG
ES H
AVE A M
INIM
UM
BEND
RAD
IUS
OF 381m
m(15")
4.WAR
NIN
G: TO
PREV
ENT IG
NITIO
N O
F FLAMM
ABLE OR
CO
MBU
STIBLE ATMO
SPH
ERES,
DISC
ON
NEC
T POW
ER BEFO
RE SE
RVIC
ING
5.W
ARN
ING
: THE EQ
UIPM
ENT C
ON
TAINS N
ON
-METALLIC
ENC
LOS
UR
E AND
PRO
CESS PA
RTS, TO
PREVEN
T TH
E RIS
K OF ELEC
TRO
STATIC
SPARKIN
G. TH
E NO
N-M
ETALLIC SU
RFAC
E AND
PRO
CESS PAR
TS S
HO
ULD
ON
LY BE C
LEAN
ED W
ITH A D
AMP C
LOTH
. PAINTED
SURFACE O
F THE EQ
UIPM
ENT M
AY STORE ELECTR
OSTATIC CH
ARGE
AND
BECOM
E A SOU
RCE OF IG
NITIO
N IN
APPLICATION
S WITH
A LOW
RELATIVE H
UM
IDITY <
~30%
RELATIVE H
UM
IDITY W
HER
E THE PAIN
TED SU
RFACE IS RELATIVELY FR
EE OF SU
RFACE CO
NTAM
INATIO
N SU
CH AS D
IRT, DU
ST OR O
IL. CLEANIN
G O
F T HE PAIN
TED SU
RFACE SHO
ULD
ON
LY BE DO
NE
WITH
A DAM
P CLOTH
.6. C
ABLES SH
ALL BE R
ATED > 5C
ABOVE M
AXIMU
M A
MB
IEN
T TEMPER
ATUR
E. 7. TO
MAIN
TAIN
THE IN
GR
ESS PRO
TEC
TION
RATIN
G O
F IP65, TEFLO
N TAPE
(3 WR
APS) O
R PIPE D
OPE SH
ALL BE U
SED
. REFER
TO IN
STALLATION
INSTR
UC
TION
S.8. TH
E EQU
IPMEN
T CAN
BE IN
STALLED IN
THE BO
UN
DA
RY W
ALL BETWEEN
AN EPL G
a AR
EA AND
THE
LESS HA
ZARD
OU
S AR
EA, EPL G
b. IN TH
IS CO
NFIG
UR
ATION
, THE PR
OC
ESS CO
NN
ECTIO
N IS IN
STALLED
IN EPL G
a, WH
ILE THE TR
ANSM
ITTER H
OU
SING
IS INSTALLED
IN EPL G
b. REFE
R TO
INSTALLATIO
N
INSTR
UC
TION
S. EQ
UIPM
ENT C
AN BE IN
STALLED
IN A BO
UN
DAR
Y WALL C
ON
FIGU
RATIO
N W
HER
E THE PR
OC
ESS CO
NN
ECTIO
N IS IN
STALLED A
S CATEG
OR
Y 1G EQ
UIPM
ENT W
HILE TH
E TRAN
SMITTER
HO
USIN
G IS IN
STALLED
AS C
ATEGO
RY 2G
EQU
IPMEN
T. REFER
TO IN
STALLATION
INSTR
UC
TION
S. 9. TH
E APPLICABLE TE
MP
ERATU
RE C
LASS OF TH
E EQU
IPMEN
T, AMBIEN
T TEM
PER
ATUR
E RAN
GE,
AND
MAXIM
UM
PRO
CESS TEM
PER
ATUR
E OF TH
E EQU
IPMEN
T IS AS FOLLO
WS;
T3 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +150°C T4 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +135°C
T5 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +100°C T6 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +85°C
AMBIEN
T TEMPER
ATUR
E RAN
GE -40°CTa+71°C
10. WH
EN M
OU
NTIN
G O
N A
MAG
NETIC
LEVEL G
AUG
E MAKE SU
RE
THE ELEC
TRO
NIC
HEAD
AN
D PR
ESSUR
E BAR
RIER
HA
VE A MIN
IMU
M SP
ACIN
G O
F 5 INC
HE
S. SEE INSTALLATIO
N M
ANU
AL FOR
DE
TAIL11. FLAM
EPATHS
ARE N
OT FO
R R
EPAIR
SEE NO
TE 8
CON
DU
IT SEALCON
DU
IT
SEE NO
TE 1
5" [127mm
] Minim
um
Fig. 62: À prova de chamas, diagrama de instalação ATEX e IECEx, HART®, Página 1
Level Plus® CHAMBEREDManual de operação
I 54 I
DETAIL A
SCALE 1.60 : 1
DETAIL C
SCALE 3 : 1
DETAIL D
SCALE 1.2
A
C
D
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD D
EPTHS AR
E TO M
IN. FU
LL THD
S- D
RILL D
EPTHS AR
E TO FU
LL DIA.
- REM
OVE BU
RR
S AND
SHAR
P EDG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE FIN
ISH 3.2uM
[125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIGN
(S) DISC
LOSED
HER
EIN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RA TIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN AN
Y FOR
MEXC
EPT AS GR
ANTED
IN W
RITIN
G BY M
TSSYSTEM
S CO
RPO
RATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THAT IS IN
THE
PUBLIC
DO
MAIN
OR
WAS LEG
ITIMATELY IN
THE
PRIO
R PO
SSESSION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651552-3A
2
2 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***A
MS
10/24/14RELEASE TO
PROD
UCTIO
N
+24V GNDEARTHTX/RX+TX/RX-
GND
+24V
TX/RX-
TX/RX+
EARTH
FIGU
RE 1
SING
LE CAVITY H
OU
SING
FIGU
RE 2
DU
AL CAVITY H
OU
SING
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: C
ON
DU
IT SEALS REQ
UIR
ED W
ITHIN
50mm
OF H
OU
SING
.
+24V GND EARTH Tx/Rx+ Tx/Rx-
7957
(ACP) INSTALLATIO
N D
WG
LP DIG
ITAL EXPLO
SION
PROO
F ATEX/IEC
Fig. 63: À prova de chamas, diagrama de instalação ATEX e IECEx, HART®, Página 2
Level Plus® CHAMBEREDManual de operação
I 55 I
13.5.3 Declaração de conformidade CE
Level Plus® CHAMBEREDManual de operação
I 56 I
UNITED STATESMTS Systems Corporation
Sensors Division
3001 Sheldon DriveCary, N.C. 27513Phone: +1 919 677-0100E-mail: [email protected]
GERMANYMTS Sensor Technologie
GmbH & Co. KG
Auf dem Schüffel 958513 LüdenscheidPhone: +49 2351 9587-0E-mail: [email protected]
ITALYBranch Offi ce
Phone: +39 030 988 3819E-mail: [email protected]
FRANCEBranch Offi ce
Phone: +33 1 58 4390-28E-mail: [email protected]
GREAT BRITAIN Branch Offi ce
Phone: +44 79 44 15 03 00E-mail: [email protected]
CHINABranch Offi ce
Phone: +86 21 6485 5800 E-mail: [email protected]
JAPANBranch Offi ce
Phone: +81 3 6416 1063E-mail: [email protected]
www.mtssensors.comMTS, Temposonics and Level Plus are registered trademarks of MTS Systems Corporation in the United States; MTS SENSORS and the MTS SENSORS logo are trademarks of MTS Systems Corporation within the United States. These trademarks may be protected in other countries. All other trademarks are the property of their respective owners. Copyright © 2018 MTS Systems Corporation. No license of any intellectual property rights is granted. MTS reserves the right to change the information within this document, change product designs, or withdraw products from availability for purchase without notice. Typographic and graphics errors or omissions are unintentional and subject to correction. Visit www.mtssensors.com for the latest product information.
Código de peça do documento: 551696 Revisão E (PT) 12/2018
S a f e t y I n t e g r i t y L e v e lIEC 61508