cableadoestructurado

36
9 DE NOVIEMBREDE 2000 C A B L E A D O E S T R U C T U R A D O INSTITUTO TECNOLOGICO del istmo. PRESENTA: GERARDO NAJERA SANCHEZ PARA OBTENER EL TITULO DE: INGENIERO EN SISTEMAS COMPUTACIONALES.

Upload: alfonso

Post on 29-Jun-2015

1.789 views

Category:

Business


5 download

DESCRIPTION

Guia de Cableado Estructurado

TRANSCRIPT

Page 1: Cableadoestructurado

9 DE NOVIEMBREDE 2000

C A B L E A D O E S T R U C T U R A D O

INSTITUTO TECNOLOGICO del istmo.

PRESENTA:

GERARDO NAJERA SANCHEZ

PARA OBTENER EL TITULO DE:

INGENIERO EN SISTEMAS COMPUTACIONALES.

Page 2: Cableadoestructurado

I N D I C E

• I N T R O D U C C I Ó N

• A N T E C E D E N T E S

• D E F I N I C I O N

• S U B S I S T E M A S B Á S I C O S

• C A R A C T E R I S T I C A S

• M A R C O D E R E F E R E N C I A

• C R I T E R I O S G E N E R A L E S

• I N V E R S I O N

• V I A B I L I D A D

• B E N E F I C I O S

• C O N C L U S I O N E S

Page 3: Cableadoestructurado

Hasta mediados de los años 90´s se había venido realizando la planeación de cableado para servicios de comunicaciones en forma aislada, instalándose separadamente los cables para servicio telefónico o de voz, el servicio de redes de computadoras, el servicio de música ambiental, el servicio de intercomunicación y otros servicios.

INTRODUCCION

Page 4: Cableadoestructurado

Dado que el costo de instalación del suministro de todos estos servicios en forma aislada es muy superior y con mayores problemas respecto al que se tendría si se realizara en forma conjunta, y con la finalidad de soportar los avances tecnológicos presentes y futuros. Actualmente se promueve el diseño de redes estructuradas para las nuevas instalaciones o para las redes que por razones climáticas o de obsolescencia sea necesario sustituir para cubrir de manera integral las necesidades actuales de voz y datos y brindar una plataforma para las necesidades crecientes y futuras de las nuevas aplicaciones de las tecnologías de la información.

INTRODUCCION

Page 5: Cableadoestructurado

Hasta mediados de los años 80´s básicamente los sistemas de cableado tradicionales existentes para transferencia de información en edificios y campus administrativos se podían dividir en dos tipos de acuerdo a su aplicación:

Redes de Cableado de Voz Redes de Cableado de Datos.

ANTECEDENTES

Page 6: Cableadoestructurado

Sistemas de Cableado Tradicionales( Voz )

MDFIDF

IDF

IDF

IDF

IDFIDF

30 p

50 p20 p

10 p

6 p

6 p

PBX

ANTECEDENTES

Page 7: Cableadoestructurado

Sistemas de Cableado Tradicionales( Datos )

Terminador Terminador

PcPc Servidor Pc

Pc Impresora Pc

Nodo

C a b l e C o a x i a l

ANTECEDENTES

Page 8: Cableadoestructurado

Tendencias

▪ Integración de Servicios.

▪ Aplicaciones a Nivel de Usuario con mayores ancho de banda.

▪ Desarrollo acelerado de hardware Y Software.

ANTECEDENTES

“ Cableado Estructurado”

Page 9: Cableadoestructurado

Sistemas de CableadoTelefónico

Sistemas de Cableadopara redes de computo

Sistemas de CableadoEstructurado Propietarios

Sistemas de CableadoEstructurado

Abiertos

TIA/EIA-568 TIA/EIA-568A

19911984 1995 2000

Evolución de los Sistemas de Cableado

ANTECEDENTES

Page 10: Cableadoestructurado

DEFINICIÓN

Instalación que ofrece un sistema global para transferencia de voz, datos, imágenes, video y otros servicios tanto actuales como futuros y que esta diseñado con arquitectura integral, abierta, con posibilidades de crecimiento y soporte de nuevas tecnologías.

Page 11: Cableadoestructurado

SUBSISTEMAS BASICOS

Subsistema Backbone Campus Subsistema Sala de Equipos

Subsistema Backbone Riser(Ascendente/Vertical)

Subsistema de Administración

Subsistema Horizontal

Subsistema de Area de Trabajo

Subsistema de Administración

(entrada al edificio)

Page 12: Cableadoestructurado

▪ Topología tipo Estrella.

▪ Elimina la Segmentación de la Red.

▪ Simplifica las adiciones, movimientos y cambios.

▪ Simplifica la resolución de problemas, la identificación y aislamiento de la falla.

CARACTERISTICAS

Page 13: Cableadoestructurado

CARACTERISTICAS

▪ Facilita la administración y seguimiento del

sistema.

▪ Requiere bajo mantenimiento.

▪ Es modular para cubrir nuevas necesidades.

▪ Optimiza espacios.

▪ Satisface requerimientos de amplios anchos de banda.

Page 14: Cableadoestructurado

Desempeño de Sistemas de Cableado. • ISO/IEC International Organization for Standardization/

International Electrotechnical Commission.

• CENELEC Estandar Europeo.

• ANSI/TIA/EIA Asociation national standarlization / Telecommunication Industry Association / Electronics Industries Association

• CSA Canadian Standards Association

Seguridad.

• NFPA Nacional Fire Protection Agency• UL Underwriters Laboratories Association

Harm to the telephone network. • FCC Federal Communication Commission

Department of Communications (Canada)

Desempeño y Seguridad Canadiense. • CSA Canadian Standars Association

Organismos Normativos

MARCO DE REFERENCIA

Page 15: Cableadoestructurado

ANSI/TIA/EIA.

ANSI/TIA/EIA-568-A Commercial Building Telecommunications Wiring Standard.

ANSI/TIA/EIA-569 Commercial Building Estándar for Telecommunications Pathways and Spaces.

ANSI/TIA/EIA-570 Residential and Ligh Commercial Telecommunication Wiring Standard.

ANSI/TIA/EIA-606 Administration Standard for the Telecommunications Infrastructure of Commercial Building.

ANSI/TIA/EIA-607 Commercial Building Grounding & Bonding Requirements for Telecommunications.

TSB-53 Extended Specifications for 150-ohms STP Cables and Data Connectors.

TSB-67 Link Performance Transmission Specification for Field Testing of Unshielded Twisted Pair Cabilng Systems.

PN-2416 Backbone Cabling systems for Residential and Ligh Commercial Building (in Development).

PN-3013 Single Mode Optical Fiber Backbone Wiring for Commercial Buildings (in Development).

PN-3012 Fiber Optic Premises Cabling Guide (in Development).

Normatividad

MARCO DE REFERENCIA

Page 16: Cableadoestructurado

ISO/IEC.

ISO/IEC-11801 Generig Cabling for Customer Premises.

CENELEC.

EN-50167 Horizontal Distribution Wires.

EN-50168 Patch and Terminal connection cords.

EN-50169 Vertical Distribution Wires.

EN-50173 Link Chain.

CSA. (Desempeño)

CAN-CSA-T529 Design Guidelines for Telecommunications Wiring Systems in Commercial Buildings.

CSA. (Desempeño y Seguridad)

CAN/CSA-C22.2 No. 182.4 Plugs. Receptacles, and Connectors for Communication Systems.

CAN/CSA-C22.2 No. 214 Communications Cables, Wiring Products.

CAN/CSA-C22.2 No. 225 Telecommunication Equipment.

MARCO DE REFERENCIA

Normatividad

Page 17: Cableadoestructurado

NFPA.

NEC-1990 National Electrical Code - 1990

U L.UL444 Standard for Safety, Communications Cables.

UL497 Standar for Safety, Protectors for Communications Circuits.

UL497A Standard for Safety, Secondary Protectors for Communications Circuits.

UL497B Standard for Safety, Protector for Data Communications and Fire Alarm Circuits.

UL1459 Standar for Safety, Telephone Equipment.

UL1863 Standard for Safety, Communication Circuit Accesories.

FCC.Title 47 The minimum acceptable protection communications Part 68 equipment must provide the telephone network

Code of FederalRegulationsDCC.

CS-03 Certification Standard. Standard for terminal equiment, terminal systems, network protection divices, connection arragements and hearing aid compatibility.

MARCO DE REFERENCIA

Normatividad

Page 18: Cableadoestructurado

M o d e l o

Area de Trabajo Campo Horizontal Campo EquiposSalida de

telecomunicaciones

Cable Horizontal

Cordon de Parcheo

Cable del Area de Trabajo

Cable de Equipo

3 metros máx.A

90 metros máx. 7 metrosB

A + B menor ó igual 10 mts.

ANSI/TIA/EIA- 568-A

MARCO DE REFERENCIA

Page 19: Cableadoestructurado

Area de Trabajo Campo Horizontal Campo EquiposSalida de

telecomunicaciones

Cable Horizontal

Cordon de Parcheo

Cable del Area de Trabajo

Cable de Equipo

A90 metros máx. 5 mts. máx.

B

A + B + E menor ó igual 10 mts.

E

MARCO DE REFERENCIA

M o d e l o

ISO/IEC 1180

Page 20: Cableadoestructurado

Clasificación de Cableado

Categoría Ancho de Velocidad Banda

No. 3 16 Mhz 10 Mbps No. 4 20 Mhz 16 Mbps No. 5 100 Mhz 100 Mbps (*)

TIA/EIA

MARCO DE REFERENCIA

▪ Coaxial▪ Par trenzado 4 pares (UTP)▪ Par Trenzado 2 pares (STP)▪ Fibra Optica.

(UTP)

Page 21: Cableadoestructurado

T568A T568B (AT&T 258A)

1 2 3 4 5 6 7 8

1 3 4 2

1 2 4 3

# de pin:

# de par:

# de pin:

# de par:

1 2 3 4 5 6 7 8 W-G G W-O BL W-BL O W-BR BR W-O O W-G BL W-BL G W-BR BR

Conectorización de Cableado

MARCO DE REFERENCIA

▪Todos los pines/pares deben estar conectados en sus

dos extremos

▪Un enlace funcionara unicamente con un sistema de comunicación

Page 22: Cableadoestructurado

Subsistema de Area de Trabajo

CRITERIOS GENERALES

Salida de Telecomunicaciones

Placa

Cableado del área de trabajo(Linkcord)

Cableado horizontalCaja

Page 23: Cableadoestructurado

Subsistema Horizontal

Cables reconocidos para cumplimiento de instalación estandarizada: UTP 4 pares, 100 ohms, 24 awg, conductores solidos STP 2 pares, 150 ohms 24 awg, conductores solidos F.O. 62.5/125 multimodo

CRITERIOS GENERALES

Salida de Telecomunicaciones

Cable horizontal

Placa Caja

Elementos Subsistema de Administración

90 m.

Area de trabajo.

Page 24: Cableadoestructurado

Subsistema Vertical

CRITERIOS GENERALES

Aspectos:

1) Comunicación entre pisos2) Tipos de cable3) Dimensionamiento de las terminaciones de cable4) Protección Mecánica y Eléctrica.

Closet de cableado del edificio

Closet de cableado del 1er. piso

Closet de cableado del 2do. piso

Closet de cableado del 3er. piso

Cableado de campus

Cableadovertical

Page 25: Cableadoestructurado

Subsistema de AdministraciónElementos

CRITERIOS GENERALES

• Racks Abiertos (tipo bastidor)• Racks Cerrados (tipo Gabinete)• Organizadores de cables• Charolas• Elementos de Terminación Paneles de parcheo Regletas tipo 110 Modulo tipo 66• Cordones de Parcheo RJ-45• Jumpers de Fibra Optica• Jumpers de cobre de par trenzado• Cordones de parcheo tipo 110• Contactos polarizados• Ventiladores y Extractores• UPS

Page 26: Cableadoestructurado

X

X

XXX

X

X

X X

XX

X

Purpura

Purpura Azul

Azul

GrisAzul

Blanco Amarillo

Verde

Gris

Blanco Café Azul

Naranja

Cafe

Salida de Telecomns

Backbone Campus

Backbone 2do. Nivel

Backbone Riser

Subsistema de Administración

Códigos de Colores

CRITERIOS GENERALES

Page 27: Cableadoestructurado

Subsistema de BackboneCampus

CRITERIOS GENERALES

▪ Cable 4 pares 100 ohms UTP

▪ Fibra Optica Multimodo 850 nm y 1300 nm

▪ Fibra Optica Monomodo 1310nm y 1550 nm

Page 28: Cableadoestructurado

Sala de equipos

CRITERIOS GENERALES

Subsistema Backbone Campus Subsistema Sala de Equipos

(entrada al edificio)

Page 29: Cableadoestructurado

Infraestructura

CRITERIOS GENERALES

• Escalerilla

• Canaleta

• Tubería Conduit

Page 30: Cableadoestructurado

CRITERIOS GENERALES

Tipo de Cable Diámetro de Tubería (pulgadas)

Categoría No. 3 (4 pares)

Categoría No. 5 (4 pares)

Categoría No. 5 (25 pares)

F.O. Exterior (1-48 fibras)

F.O. Interior (1-12 fibras)

Cat. 3 multipar ext/int (100 pares)

Cat. 3 multipar ext/int (50 pares)

3/4 1 1 1/2 2 3 4

4 5 12 18 41 71

3 5 11 16 35 61

1 3 6 14 25

1 3 7 13

1 2 5 10 13 42

1 2 4

1 3 6

Capacidad de tubería

Infraestructura

Page 31: Cableadoestructurado

5% 7%

54%

34%Cableado

Accesorios de RedLAN

Software yMainframe

Computadoras

I N V E R S I Ó N

Page 32: Cableadoestructurado

VIABILIDAD

0

1

2

3

4

5

6

7

8

Software Red Lan Estación deTrabajo

Mainframe Sistema deCableado

Años

Permanencia de los Sistemas

Page 33: Cableadoestructurado

Tiempo

Costo No Estructurado

Estructurado

Costo de Vida Util

VIABILIDAD

Page 34: Cableadoestructurado

BENEFICIOS

LOS BENEFICIOS QUE SE OBTIENEN POR LA INSTALACIÓN DE UN SISTEMA DE CABLEADO ESTRUCTURADO ESTAN DIRECTAMENTE RELACIONADOS CON :

▪ Oportuna asimilación y aprovechamiento de nuevas tecnologías de la información para enfrentar la creciente competitividad.

▪ Minimiza el costo de los cambios implicados.

▪ Independencia de proveedores.

Page 35: Cableadoestructurado

▪ Disminución de los tiempos de respuesta para atender nuevas necesidades de servicios.

▪ Disminución de costos de mantenimiento.

▪ Plataforma física común con independencia de proveedores de equipos.

▪ Costo menor dentro de todo el ciclo de vida útil.

▪ Aprovechamiento de espacios en instalaciones.

BENEFICIOS

Page 36: Cableadoestructurado

• Esfuerzo adicional de Planeación de los servicios actuales y futuros.

• Ventajas inherentes de Costos Operativos y Calidad de Servicio.

• Mayor aprovechamiento en la implantación y asimilación de presentes y futuras tecnologías para la competitividad.

CONCLUSIONES