Perda de Carga Linha 6"-AG-1000A Material Quant. Comprim. Equiv. (mca) Total CURVA 90GR RL ASME B16.9 SCH40 BW 6" 9 3,4 30,6 TUBO ASTM A-106 GRB S/COST SCH40 PC 6" 48,924 0,0235 1,15 VALV BRB FF A126/FF 11 150LB B16.5 W SL 6" 1 1,9 1,9 VALV GLB BS1873 A216 WCB/410 PTFE 150LB 6" 1 51 51 Total 84,65 Linha 6"-AG-1001A Material Quant. Comprim. Equiv. (mca) Total CURVA 90GR RL ASME B16.9 SCH40 BW 6" 9 3,4 30,6 TUBO ASTM A-106 GRB S/COST SCH40 PC 6" 42,724 0,0235 1 VALV BRB FF A126/FF 11 150LB B16.5 W SL 6" 1 1,9 1,9 Total 33,5 Linha 6"-AG-1003A Material Quant. Comprim. Equiv. (mca) Total CURVA 90GR RL ASME B16.9 SCH40 BW 6" 6 3,4 20,4 TUBO ASTM A-106 GRB S/COST SCH40 PC 6" 13,95 0,0235 0,3 VALV BRB FF A126/FF 11 150LB B16.5 W SL 6" 3 1,9 5,7 VALV DE RET PU WAFER WCB/316 150LB RF 6" 2 19,3 38,6 COTOVELO 90GR ASME A105 3000 LB SW 1/2" 2 0,47 0,94 RED CONC ASME B16.9 A234 SCH40 BW 6"X3" 2 3,6 7,2 TE 90GR ASME B16.9 A234 WPB SCH40 BW 6" 1 10 10 VALV ESF PP TRIP WCB/304 PTFE 300LB TW 1/2" 2 1,8 3,6 Total 86,74

Upload: robson-fabian

Post on 26-Sep-2015

229 views

Category:

Documents


0 download

DESCRIPTION

Demonstra a perda de carga ocorrida em um sistema de tubulação industrial.

TRANSCRIPT

Perda de Carga

Linha 6"-AG-1000A

MaterialQuant.Comprim. Equiv.(mca)Total

CURVA 90GR RL ASME B16.9 SCH40 BW 6"93,430,6

TUBO ASTM A-106 GRB S/COST SCH40 PC 6"48,9240,02351,15

VALV BRB FF A126/FF 11 150LB B16.5 W SL 6"11,91,9

VALV GLB BS1873 A216 WCB/410 PTFE 150LB 6"15151

Total84,65

Linha 6"-AG-1001A

MaterialQuant.Comprim. Equiv.(mca)Total

CURVA 90GR RL ASME B16.9 SCH40 BW 6"93,430,6

TUBO ASTM A-106 GRB S/COST SCH40 PC 6"42,7240,02351

VALV BRB FF A126/FF 11 150LB B16.5 W SL 6"11,91,9

Total33,5

Linha 6"-AG-1003A

MaterialQuant.Comprim. Equiv.(mca)Total

CURVA 90GR RL ASME B16.9 SCH40 BW 6"63,420,4

TUBO ASTM A-106 GRB S/COST SCH40 PC 6"13,950,02350,3

VALV BRB FF A126/FF 11 150LB B16.5 W SL 6"31,95,7

VALV DE RET PU WAFER WCB/316 150LB RF 6"219,338,6

COTOVELO 90GR ASME A105 3000 LB SW 1/2"20,470,94

RED CONC ASME B16.9 A234 SCH40 BW 6"X3"23,67,2

TE 90GR ASME B16.9 A234 WPB SCH40 BW 6"11010

VALV ESF PP TRIP WCB/304 PTFE 300LB TW 1/2"21,83,6

Total86,74

Linha 8"-AG-1002A

MaterialQuant.Comprim. Equiv.(mca)Total

CURVA 90GR RL ASME B16.9 SCH40 BW 8"34,312,9

TUBO ASTM A-106 GRB S/COST SCH40 PC 8"2,250,00540,012

VALV BRB CXR FF A126/FF 150LB B16.5 W SL 8"32,67,8

RED CONC ASME B16.9 A234 SCH40 BW 8"X6"24,89,6

TE 90GR ASME B16.9 A234 WPB SCH40 BW 6"11313

VALV ESF PP TRIP WCB/304 PTFE 300LB TW 1/2"21,83,6

Total46,912

Fonte: Manual Tcnico - KSB / Catlogo de Conexes Tupy / Catlogo de Vlvulas Nigara / Manual Tcnico KaeserCom estes valores de perda de carga no sistema, podemos encontrar o valor da altura manomtrica total, que o item necessrio para escolhermos a bomba a ser utilizada no sistema.Para encontrarmos a altura manomtrica total, preciso o valor da altura de suco mais a altura de recalque e a perda de carga. Somando todos, encontra-se o valor da altura que neste caso, foi estimado em torno de 133,65m aproximadamente.Com o valor de vazo calculado em 112,5 m/h e altura manomtrica encontrada anteriormente, podemos estipular a bomba a ser utilizada, olhando na figura abaixo, que foi retirada do catlogo de bombas KSB.

Ao verificarmos esta figura, conclumos que a bomba para ser utilizada neste sistema, dever ser a bomba 80-250, pois esta a que melhor se encaixa nas condies especificadas pelos clculos.