caracterizaÇÃo do esmalte dentÁrio e remanescentes

67
JORGE CÉSAR BORGES LEÃO FILHO CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES ADESIVOS APÓS A REMOÇÃO DE BRACKETS POR MEIO DE TOMOGRAFIA POR COERÊNCIA ÓPTICA CURITIBA 2012 PONTIFÍCIA UNIVERSIDADE CATÓLICA DO PARANÁ ESCOLA DE SAÚDE E BIOCIÊNCIAS PROGRAMA DE PÓS-GRADUAÇÃO EM ODONTOLOGIA ÁREA DE CONCENTRAÇÃO EM ORTODONTIA

Upload: others

Post on 16-Oct-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

JORGE CÉSAR BORGES LEÃO FILHO

CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E

REMANESCENTES ADESIVOS APÓS A REMOÇÃO DE

BRACKETS POR MEIO DE TOMOGRAFIA POR COERÊNCIA

ÓPTICA

CURITIBA

2012

PONTIFÍCIA UNIVERSIDADE CATÓLICA DO PARANÁ ESCOLA DE SAÚDE E BIOCIÊNCIAS

PROGRAMA DE PÓS-GRADUAÇÃO EM ODONTOLOGIA ÁREA DE CONCENTRAÇÃO EM ORTODONTIA

Page 2: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E

REMANESCENTES ADESIVOS APÓS A REMOÇÃO DE

BRACKETS POR MEIO DE TOMOGRAFIA POR COERÊNCIA

ÓPTICA

CURITIBA

2012

Dissertação apresentada ao Programa de Pós-graduação

em Odontologia, da Pontifícia Universidade Católica do

Paraná, como parte dos requisitos para a obtenção do

Título de Mestre em Odontologia, Área de concentração

em Ortodontia.

Pós-graduando: Jorge César Borges Leão Filho

Orientador: Prof. Dr. Orlando Tanaka

Co-orientadora: Dra. Ana Karla Souza Braz

Page 3: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

Dedicatória

Dedico...

Primeiramente, a Deus por iluminar o meu caminho e colocar em minha vida

anjos, em carne ou não, que me auxiliam a alcançar o aprimoramento moral,

espiritual e profissional. Ao pai-do-céu agradeço, pelos desafios que encontrei

em minha vida, e que me permitiram lapidar o caráter, por meio do aprendizado

oriundo do esforço e do trabalho.

Ao homem, que num primeiro gesto de amor colocou-me seu próprio nome,

Jorge César Borges Leão, e a mulher, Ilma Maria Acioly Teixeira Leão, cujo

afeto maternal me conforta mesmo a grandes distâncias. Meus amados pais,

agradeço-lhes por me apoiar de forma incondicional, mesmo diante das

incertezas e dificuldades. Tudo que sou hoje devo a vocês.

À minha querida noiva Thayse Rodrigues de Souza, por suportar bravamente,

o peso da distância junto comigo, demonstrando que, para o amor e a afinidade

espiritual verdadeiros, alguns quilômetros não representam uma barreira real.

Muito obrigado por ser combustível de minha força de vontade e estímulo para

a busca do que há de melhor em mim.

À menina cujo sorriso alegra-me a alma, minha irmã, Júlia Maria Acioly Teixeira

Leão e ao meu irmão Júlio César Teixeira Leão.

A dois grandes amigos conquistados nesta etapa de minha vida, José

Guilherme Camargo Teixeira da Cunha e Regis Meller Santana, por serem

minha família em um lugar tão longe de casa. Sou grato por compartilharem

comigo os momentos de alegria e de dificuldade.

Page 4: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

Agradecimentos

Agradeço...

Ao professor Dr. Orlando Motohiro Tanaka, por instruir-me e orientar-me no

desenvolvimento de minhas potencialidades, não somente durante a execução

deste trabalho, mas durante todo o mestrado. Agradeço-o sinceramente pelo

voto de confiança depositado em mim, tornando possível todas as minhas

conquistas pessoais nos últimos dois anos. Levarei comigo as “cicatrizes” e as

belezas das experiências vividas, como lembrete do aprendizado adquirido.

Obrigado mestre, pelas lições e por estar ao meu lado sempre que precisei.

A Dra. Ana Karla Souza Braz, pela participação ativa e indispensável na

realização deste trabalho. Obrigado por acolher minhas ideias, ajudar-me a

desenvolvê-las e executá-las.

Ao Prof. Renato Evangelista de Araújo por abrir-me as portas de seu

laboratório, sendo sempre muito receptivo e acessível.

Ao prof. Sérgio Aparecido Ignácio pela atenção e ajuda, sempre muito

cuidadosa, não apenas neste trabalho, mas em todos os outros realizados por

mim durante o mestrado.

Aos professores Elisa Souza Camargo, Odilon Guariza Filho, Edvaldo Antônio

Ribeiro Rosa e Sérgio Vieira, e a todo corpo docente do programa de pós-

graduação em odontologia da Pontifícia Universidade Católica do Paraná, por

contribuírem para minha formação e crescimento profissional.

Aos colegas da oitava turma de mestrado em ortodontia da PUCPR, Ana Paula

Lazzari Marques Peron, Bruno Borges de Castilhos, Camila Rychuv Santos,

Cristiano Miranda de Araujo, Giovana Carla Franzon Frigotto, José Guilherme

Camargo Teixeira da Cunha, Luciana Trevisan Bittencourt Muniz, Marcel

Durante Brunet, Regis Meller Santana e Viviane da Silva Kagy, por

compartilharem comigo todos os momentos românticos e não-românticos da

trajetória de nosso curso.

Page 5: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

SUMÁRIO

1. Artigo em português

Página Título 2

Resumo 3

Introdução 4

Materiais e Métodos 5

Resultados 9

Discussão 11

Conclusão 14

Referências 15

Figuras 18

Tabelas 23

Lista de abreviaturas 24

2. Artigo em Inglês

Title page 26

Abstract 27

Introduction 28

Methods 29

Results 32

Discussion 34

Conclusion 36

References 38

Page 6: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

Figures 41

Tables 46

List of abbreviations 47

3. Anexos 48

Anexo I - Parecer do Comitê de Ética em Pesquisa da PUCPR 49

Anexo II - Análise estatística 50

Anexo III – Metodologia estendida 56

Anexo IV – Normas para publicação – American Journal of Orthodontics and

Dentofacial Orthopedics 58

Page 7: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

1

1. ARTIGO EM PORTUGUÊS

Page 8: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

2

Caracterização do esmalte dentário e remanescentes adesivos após a remoção de brackets por meio de Tomografia por Coerência Óptica

Jorge César Borges Leão Filho, DDS Pontifícia Universidade Católica do Paraná, Curitiba, Brazil. School of Health and Biosciences Dentistry Graduate Program – Orthodontics Email: [email protected] Ana Karla Souza Braz Universidade Federal de Pernambuco, Pernambuco, Recife, Brazil. Biomedical Engineering Postgraduate Program Email: [email protected] Corresponding author

Orlando Motohiro Tanaka, DDS, PhD Professor, Graduate Dentistry Program, Orthodontics Pontifícia Universidade Católica do Paraná, Curitiba, Brazil School of Health and Biosciences Postdoctoral Fellow in The Center for Advanced Dental Education at Saint Louis University Email: [email protected]

Page 9: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

3

RESUMO

Introdução: Os objetivos deste estudo foram (1) avaliar quantitativamente a

presença de remanescentes adesivos e fragmentos de brackets sobre o

esmalte, além de fraturas deste tecido após a descolagem de brackets

metálicos e cerâmicos; (2) quantificar em profundidade a camada de

remanescentes adesivos após dois diferentes procedimentos de cleanup.

Métodos: Brackets metálicos e cerâmicos foram colados em 120 incisivos

superiores humanos e em seguida descolados utilizando-se duas técnicas

diferentes. As amostras foram, então, submetidas à avaliação do esmalte com

a Tomografia por Coerência Óptica (TCO). Em sequência, dois métodos

diferentes de remoção dos remanescentes adesivos (Brocas de Tungstênio em

alta e baixa rotação) foram realizados e, ao fim destes procedimentos, a

camada de remanescentes adesivos foi mensurada com a TCO. Resultados e

conclusões: (1) O tipo de técnica de descolagem (com alicates de corte de

amarrilho ou alicates de remoção de brackets anteriores) e o tipo de bracket

não influenciam a quantidade de remanescentes adesivos após descolagem;

(2) fraturas de esmalte foram observadas somente nas amostras coladas com

brackets cerâmicos, sendo que o tipo de alicate não influencia a incidência e

extensão do dano ao esmalte; (3) brocas em baixa rotação são mais efetivas

na remoção dos remanescentes adesivos.

Page 10: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

4

INTRODUÇÃO

O desenvolvimento dos sistemas adesivos proporcionou a criação de

métodos efetivos para a colagem de brackets ortodônticos na superfície do

esmalte dentário. Apesar deste procedimento facilitar a montagem dos

aparelhos ortodônticos fixos, existe um verdadeiro dilema em sua utilização: a

adesão dos acessórios ortodônticos à superfície do esmalte deve ser suficiente

para permitir que o mesmo sofra a ação de forças externas sem ser descolado,

porém, tal adesão não deve ser excessiva para prevenir possíveis danos à

estrutura do esmalte no momento da remoção destes acessórios.1

As técnicas mais utilizadas para a remoção de brackets incluem a

utilização de alicates que, a partir de uma combinação de forças de tração e

cisalhamento, promovem três tipos de falhas: (1) falha adesiva entre a base do

bracket e o adesivo, (2) falha adesiva entre o adesivo e o esmalte e (3) falha

coesiva entre as moléculas do adesivo. Em regiões de fraturas de esmalte há a

falha coesiva no interior deste tecido.1

A avaliação do esmalte após a remoção de brackets usualmente é

realizada por meio de microscopia óptica e microscopia eletrônica de

varredura.1-6 Além desses métodos a microscopia de força atômica e a

microscopia de varredura por tunelamento também foram aplicadas na

avaliação da superfície dentária.7 No entanto, todas estas técnicas possibilitam

apenas uma análise de superfície do esmalte. A Tomografia de Coerência

Óptica (TCO) permite a captação de imagens em alta resolução, de forma

rápida e não-invasiva, sendo capaz de gerar imagens em 3D de superfície,

assim como imagens em corte transversal (2D) dos tecidos avaliados.8,9 A TCO

pode ser considerada como análoga à técnica de ultra-som, no sentido de que

a onda refletida pelo tecido transporta a informação estrutural da amostra

biológica. Diferente de equipamentos de ultra-som, a TCO utiliza luz em vez de

ondas sonoras, gerando imagens tomográficas com a resolução espacial de

poucos micrometros.10

A TCO vem sendo amplamente utilizada para propósitos médicos,11-13

principalmente na Oftalmologia.14 Em Odontologia, esta tecnologia tem sido

aplicada para caracterização anatômica das estruturas dentais15-17 e

Page 11: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

5

periodontais,15 detecção de cáries incipientes,18-20 avaliação de restaurações21

e materiais dentários,22-24 marcador qualitativo de biofilme formado em torno de

brackets25 e avaliação das respostas do ligamento periodontal sob ação de

forças ortodônticas.26 No entanto, não existem relatos na literatura sobre o uso

do TCO para avaliação da estrutura do esmalte após a descolagem de

brackets ortodônticos e após a remoção do remanescente adesivo.

Portanto, os objetivos do presente estudo são: 1) avaliar

quantitativamente a presença de remanescentes adesivos e fragmentos de

brackets sobre o esmalte, além da presença de áreas de fratura deste tecido

após a descolagem de brackets metálicos e cerâmicos. 2) quantificar em

profundidade a camada de remanescentes adesivos após dois diferentes

procedimentos de cleanup.

MATERIAL E MÉTODOS

Amostras e grupos

Cento e vinte incisivos superiores humanos, obtidos no banco de dentes

da Pontifícia Universidade Católica do Paraná, livres de lesões de cárie,

trincas, rachaduras e manchas foram selecionados para o estudo e

armazenados em solução de 0,1% de Timol. Inicialmente (T1), os dentes foram

aleatoriamente divididos em 4 grupos (n=30) de acordo com o tipo de bracket

colado e o tipo de alicate utilizado para a remoção destes acessórios (Figura

1). Após a descolagem dos brackets foi realizada a avaliação da superfície do

esmalte com a TCO. Em seguida (T2), cada grupo foi dividido em dois

subgrupos (n=15), e em cada subgrupo foi utilizado um método diferente para a

remoção dos remanescentes de adesivo sobre o esmalte (Brocas de

Tungstênio em alta e baixa rotação). O presente estudo foi aprovado pelo

comitê de ética da Pontifícia Universidade Católica do Paraná, sob o nº 17563.

Procedimento de colagem dos brackets

Antes da colagem dos brackets, as faces vestibulares de todos os

dentes foram examinadas com a TCO, em modo 3D e 2D, excluindo-se

aquelas em que foram observadas trincas, rachaduras ou lesões de cárie no

esmalte. Em seguida, foram realizados os procedimentos de colagem, para os

Page 12: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

6

quais foram utilizados brackets metálicos Edgewise-standard (American

Orthodontics, Sheboygan,USA) e cerâmicos (Morelli, Sorocaba, Brasil).

Inicialmente, as superfícies vestibulares dos dentes foram condicionadas com

ácido fosfórico 37% (Condac 37, FGM, Joinvile, Brasil) durante 20 segundos,

lavadas com jato de água durante 10 segundos e secas com jatos de ar por 10

segundos.

A colagem foi executada utilizando-se o sistema Transbond Plus Color

Change Adhesive (3M Unitek, Monrovia USA), de acordo com as instruções do

fabricante. O primer foi aplicado sobre a superfície de esmalte condicionado e o

cimento adesivo aplicado sob a base dos brackets. Após o posicionamento dos

brackets na face vestibular dos dentes foi aplicada uma força de 400g/F

perpendicularmente aos brackets, com o auxílio de um dinamômetro (Morelli,

Sorocaba, Brasil), para padronizar a espessura da camada de cimento adesivo

na interface esmalte-bracket. Em seguida, os excessos de cimento foram

removidos e a fotopolimerização foi efetuada com o equipamento Radii-Cal

(SDI Inc., Bensenville, USA), sendo a luz aplicada nas porções cervical e

incisal dos brackets, durante 20 segundos em cada. Ao fim do procedimento de

colagem, as amostras foram armazenadas em água destilada por um período

de 24 horas.

Procedimentos de descolagem dos brackets

A descolagem dos brackets foi realizada utilizando-se dois tipos

diferentes de alicates: (1) Alicate de Corte de Amarrilho (ACA) (Modelo i-552,

Rocky Mountain Orthodontics, Denver, USA); (2) Alicate para Remoção de

Brackets Anteriores (ARBA) (Modelo E-346, Piramid Orthodontics, Corte

Madera, EUA). Apesar de serem possíveis algumas variações na técnica de

descolagem, tal procedimento foi realizado de forma padronizada.6

O ACA foi posicionado diagonalmente nas margens cervical e incisal da

base dos brackets. O bracket foi removido com uma leve pressão do alicate

associada a um movimento rotacional no sentido horário (Figura 2,A).

O ARBA foi utilizado posicionando-se as suas pontas ativas na interface

bracket-esmalte nas margens cervical e incisal da base dos brackets. O bracket

Page 13: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

7

foi, então, removido com um movimento de inclinação para cervical do alicate,

criando um eixo rotacional na margem cervical do bracket. (Figura 2,B)

Imediatamente após à remoção dos brackets, os dentes foram

novamente examinados com a TCO, gerando imagens da superfície do

esmalte em 3D (5mmx5mm) da região dos remanescentes adesivos.

Quantificação dos remanescentes adesivos em T1

As imagens dos remanescentes adesivos gerados após a remoção dos

brackets foram processadas no software ImageJ (versão 1.44p, Wayne

Rasband National Institutes of Health, EUA). Neste software foram feitas as

seguintes mensurações: (1) Área de adesivo remanescente; (2) Área de fratura

de esmalte (caso fosse observada alguma região de fratura); (3) Área de

fragmentos de bracket (caso fossem observados fragmentos de brackets

gerados pela sua fratura). Todas estas mensurações foram transformadas em

valores percentuais, tendo como base a área total da base dos brackets (Figura

3). Todas estas mensurações foram convertidas em porcentagem, de acordo

com a seguinte equação:

Procedimentos de remoção dos remanescentes adesivos

Para a remoção dos remanescentes adesivos foram utilizadas dois tipos

de brocas de Carboneto de Tungstênio (Carbide): (1) Brocas de alta rotação

(Modelo CF375R, Beijing Smart Technology, Beijing, China) à 300.000 RPM;

(2) Brocas de baixa rotação (Modelo CB27204, Beijing Smart Technology,

Beijing, China) 7500 RPM. Estes procedimentos foram realizados por um único

operador, com as brocas sempre posicionadas paralelamente ao longo eixo

dos dentes, com movimentos de vai-e-volta de mesial para distal. O

procedimento, para cada amostra, foi considerado concluído após observação,

visual e macroscópica, da remoção satisfatória dos remanescentes. Uma broca

nova foi utilizada para cada dez amostras. Ao fim desta etapa, novas leituras

com a TCO, em modo 2D (corte transversal), foram realizadas.

Quantificação dos remanescentes adesivos em T2

Page 14: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

8

As imagens em corte transversal (2D) da camada de remanescente

adesivo após o uso das brocas de alta e de baixa rotação foram processadas

no software ImageJ. Neste software foram feitas as seguintes mensurações: (1)

maior profundidade da camada de adesivo remanescente (µm); (2) área da

camada de adesivo remanescente (µm2) (Figura 4).

Leituras com a TCO

Neste estudo, um sistema comercial de Tomografia por Coerência

Óptica do tipo espectral (Ganymede OCT/Thorlabs, Newton, EUA) produziu

imagens volumétricas e em cortes transversais. O sistema é baseado no

interferômetro de Michelson. Ele se conecta a um computador pré-configurado

e as imagens são obtidas por meio de uma varredura. A unidade base contém

a fonte de luz, que neste caso é um diodo superluminescente (DSL) cujo

comprimento de onda está centrado em 930nm, com largura espectral de

100nm. Com uma taxa de a-scan de 29kHz, este sistema consegue produzir 29

frames por segundo (fps) com 512 linhas por frames e uma resolução axial de

55μm. O sistema de TCO usado neste estudo produz imagens em 2D (corte

transversal) e em 3D (imagem volumétrica de superfície). As leituras com a

TCO foram realizadas antes da colagem dos brackets em T0 (2D e 3D), após a

remoção dos brackets em T1 (3D) e após a remoção dos remanescentes

adesivos em T2 (2D).

Análise estatística

Visando identificar diferença nos valores médios das três variáveis

analisadas em T1, segundo bracket e alicate, utilizou-se ANOVA a dois

critérios, modelo fatorial completo, uma vez que n=30. A homogeneidade de

variâncias entre os quatro grupos foi testada utilizando-se o teste de

homogeneidade de variâncias de Levene. A comparação entre os grupos após

o teste ANOVA indicar diferenças estatisticamente significantes foi feita

utilizando-se o teste de Games-Howell para variâncias heterogêneas, uma vez

que o teste de Levene indicou variâncias heterogêneas para as 3 variáveis.

Para as variáveis Área de fragmento do bracket e Área de fratura do esmalte,

que apresentaram valores constantes para metálico/ACA e metálico/ARBA,

além do teste ANOVA utilizou-se os testes não paramétricos U de Mann-

Page 15: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

9

Whitney e de Kruskal-Wallis que conduziram às mesmas conclusões do teste

paramétrico ANOVA.

Com o objetivo de identificar se existia dependência estatisticamente

significativa entre a frequência de fraturas de esmalte ocorridas e as variáveis

independentes alicate e bracket, foi utilizado o teste do Qui-Quadrado. O nível

de significância adotado foi de 5%.

Para identificar diferença nos valores médios de profundidade e área da

camada de remanescentes adesivos em T2, segundo alicate e broca, testou-se

inicialmente a normalidade dos dados através do teste de normalidade

Kolmogorov-Smirnov e a homogeneidade de variâncias entre os tratamentos

utilizando o teste de Levene. Uma vez que todos os tratamentos apresentaram

distribuição normal, utilizou-se ANOVA a dois critérios, modelo fatorial

completo. A comparação entre os diferentes tratamentos, após o teste ANOVA

indicar diferenças estatisticamente significantes, foi feito utilizando o teste de

Games-Howell para variâncias heterogêneas, ou o teste de Tukey HSD para

variâncias homogêneas. O teste de correlação linear de Pearson foi utilizado

para comparar o comportamento das variáveis profundidade e área da camada

de remanescentes em T2.

RESULTADOS

Poder de reprodutibilidade das medidas efetuadas

Na Tabela 1 encontram-se a variância total, a variância do erro, a

variância do erro em relação à variância total (Erro de Dahlberg em %), bem

como o coeficiente de confiabilidade e o coeficiente de correlação de Pearson,

para as variáveis mensuradas durante o presente estudo. Para a análise do

erro de Dalhberg, de modo ideal, a variância do erro não deve exceder 3% da

variância total, sendo que apenas nos casos cuja variância do erro for maior

que 10% a mensuração seria imprópria27,28. No presente estudo o erro de

Dahlberg não ultrapassou 2,16% nas mensurações realizadas, indicando que o

avaliador reproduziu as medidas de forma aceitável (Tabela 1).

Page 16: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

10

Análise do esmalte e quantificação do remanescente adesivo após a

descolagem (T1)

Na Figura 5 observa-se a comparação entre os intervalos de confiança e

os valores médios da área de remanescente adesivo sobre o esmalte, segundo

as variáveis bracket (metálico e cerâmico) e alicate (ACA e ARBA). A Tabela 2

apresenta o resultado do teste de comparações múltiplas de Games-Howell

para as variáveis presentes na Figura 5. Verificou-se que, apesar de os

brackets metálicos sempre apresentarem menor valor médio de remanescente

adesivo que os brackets cerâmicos, independentemente do tipo de alicate

usado para a descolagem, não houve diferença estatisticamente significativa

entre estes valores (p>0,05). Da mesma forma, não foi observada diferença

estatisticamente significativa (p>0,05) entre os alicates ACA e ARBA, tanto

para brackets metálicos como para brackets cerâmicos, mesmo que o alicate

ARBA tenha sempre apresentado valores médios de área de remanescente

adesivo menores que o ACA.

Na Figura 6 observa-se a comparação entre os intervalos de confiança e

os valores médios de área de fragmentos de bracket sobre o esmalte, segundo

as variáveis bracket (metálico e cerâmico) e alicate (ACA e ARBA). Observou-

se que as fraturas ocorreram apenas em brackets cerâmicos, e que o uso do

alicate ACA resultou em menor valor médio de fragmentos destes brackets. No

entanto, não houve diferença estatisticamente significativa entre a quantidade

de fragmentos produzidos pelo uso dos alicates ACA e ARBA (p>0,05).

Na Figura 7 observa-se a comparação entre os intervalos de confiança e

os valores médios de área de fratura do esmalte, segundo as variáveis bracket

(metálico e cerâmico) e alicate (ACA e ARBA). Observou-se que as fraturas de

esmalte ocorreram apenas em amostras coladas com brackets cerâmicos, e

que o uso do alicate ACA resultou em menor média de áreas de fratura. No

entanto, não houve diferença estatisticamente significativa entre a quantidade

de fraturas de esmalte produzidas pelo uso dos alicates ACA e ARBA (p>0,05).

A Figura 8 apresenta a frequência da ocorrência de fraturas de esmalte

segundo as variáveis bracket e alicate. Observa-se que o dano ao tecido

dentário ocorreu apenas na descolagem de brackets cerâmicos e que as duas

Page 17: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

11

técnicas de descolagem produzem uma frequência de fraturas estatisticamente

semelhantes (p>0,05).

Profundidade e área da camada de remanescente adesivo após clean-up (T2)

Após a realização dos procedimentos de remoção dos remanescentes

adesivos, observou-se que o uso de broca de baixa rotação permite a obtenção

de uma superfície de esmalte com menor quantidade de resíduos adesivos

quando comparada ao uso de broca de alta rotação, tanto para a profundidade

(Figura 9) quanto para a área (Figura 10) da camada de remanescente adesivo

(p<0,05). O teste de correlação linear de Pearson demonstrou correlação

estatisticamente significativa entre os valores de profundidade e área

mensuradas (p<0,05; r=0,7662), o que indica que estes dois parâmetros podem

ser utilizados para quantificar a camada de remanescentes adesivos.

DISCUSSÃO

A descolagem de brackets é um procedimento que gera riscos de danos

ao esmalte dentário, na forma de rachaduras, arranhões ou perda de

tecido.29,30 A chave para a preservação deste tecido pode ser o uso de

instrumentos que evitem o desenvolvimento de falhas adesivas na interface

esmalte-adesivo, deixando sobre a superfície do dente a maior quantidade

possível de remanescentes adesivos.31 Knosel et al6 observaram que a

manutenção da integridade estrutural do esmalte após a descolagem coincide

com a presença de maiores quantidades de remanescentes adesivos.

Os dois alicates avaliados no presente estudo geraram grandes

quantidades de remanescentes adesivos: 87,29 ± 1,89% para o ACA e 80,96 ±

3,14% para o ARBA (Figura 1). A quantidade de remanescentes adesivos foi

estatisticamente semelhante para o uso destes dois alicates (p> 0.05), fato que

está em concordância com o estudo de Knosel.6 Estas observações sugerem

que, tanto o ACA quanto o ARBA, podem ser utilizados para a descolagem

com relativa segurança para os tecidos dentários, uma vez que as altas

quantidades de remanescentes adesivos geradas por ambos indicam falha

adesiva na interface bracket-adesivo. No entanto, em discordância com estes

resultados, Zarrinnia et al2 verificaram que o uso do ARBA promove falhas na

interface bracket-adesivo, enquanto que o ACA promove falhas na interface

Page 18: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

12

adesivo-esmalte. Porém, como o número de amostras analisadas por Zarrinnia

et al2 para a comparação entre estes dois alicates foi pequena (n=6), talvez

estas observações não sejam conclusivas.

A descolagem de brackets cerâmicos ocorre principalmente por falha na

interface esmalte-adesivo,32 enquanto que a descolagem de brackets metálicos

resulta, na maioria dos casos, da falha na interface entre o adesivo e a base do

bracket.1,32,33 No presente estudo, o tipo de bracket (metálico ou cerâmico) não

foi capaz de influenciar, de forma estatisticamente significativa, a quantidade de

remanescentes adesivos sobre o esmalte após a descolagem (p>0.05), sendo

que para ambos os tipos de bracket houve uma maior incidência de falha na

interface adesivo-bracket.

Os brackets cerâmicos são extremamente friáveis, portanto, uma

pequena quantidade de energia pode ser suficiente para fraturá-los.34,35

Clinicamente, esta fratura durante sua descolagem é indesejável, pois a

permanência de fragmentos cerâmicos sobre o dente dificultam os

procedimentos de acabamento e polimento do esmalte em um momento

posterior.36,37 Fatores como o design, técnica de descolagem, força aplicada e

a presença de ranhuras ou defeitos no bracket podem influenciar a ocorrência

de fraturas dos brackets cerâmicos durante a sua descolagem.34,38 No presente

estudo foi verificado que, tanto o ACA quanto o ARBA, produziram quantidades

estatisticamente semelhantes de fragmentos cerâmicos sobre o esmalte após

os procedimentos de descolagem (p>0.05) (Figura 6).

No presente estudo verificou-se que as fraturas de esmalte ocorreram

unicamente durante a descolagem de brackets cerâmicos, revelando o maior

risco de danos promovidos por este procedimento quando comparada à

descolagem de brackets metálicos. Estudos prévios39-41 apontam uma maior

probabilidade de fratura de esmalte após a descolagem de brackets cerâmicos,

relacionando esta tendência à forte adesão destes dispositivos ao esmalte.

Observou-se, ainda, que o tipo de instrumento utilizado para a

descolagem não afetou significativamente tanto a extensão (Figura 7) quanto a

frequência (Figura 8) dos danos ao esmalte, uma vez que não foram

observadas diferenças estatisticamente significativas entre a área e a

Page 19: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

13

frequência do dano produzido pelo uso de ACA ou ARBA (p>0,05). Estes

resultados estão de acordo com Knosel et al,6 que observaram maior incidência

de fraturas de esmalte após o uso do ARBA, porém não verificaram diferenças

estatisticamente significativas entre os dois métodos de descolagem.

Chen et al42 verificaram que a extensão e a incidência de fraturas de

esmalte não são modificadas se são utilizadas forças de tensão, cisalhamento

ou torção durante a remoção de brackets. Este fato pode justificar a ausência

de diferenças significativas na extensão da área de fratura observada pelo uso

do ACA e ARBA no presente estudo. No entanto, após realizar um estudo com

elementos finitos, Knox et al43 concluíram que fraturas no esmalte são mais

prováveis após a utilização de forças de torção quando comparadas a forças

de cisalhamento puras. Deve ser lembrado que, além da técnica utilizada para

a descolagem de brackets, fatores como a presença de trincas e defeitos

estruturais no esmalte, previamente à colagem destes dispositivos, também

podem aumentar o risco de fratura do esmalte.38,41 A exclusão de dentes com

danos no esmalte realizada no presente estudo minimiza este efeito.

Nenhum outro estudo realizado até o presente momento avaliou a

quantidade de remanescentes adesivos, em profundidade, após a realização

de diferentes procedimentos de clean-up. No presente estudo, a mensuração

da profundidade da camada de resíduos adesivos foi possível pelo uso da

TCO que permite a obtenção de imagens em corte longitudinal das estruturas

dentárias, em tempo real e de forma não-invasiva.

Verificou-se que o uso de brocas em baixa rotação permite uma remoção

mais efetiva dos remanescentes adesivos com relação às brocas em alta

rotação, uma vez que tanto a profundidade (Figura 9) quanto a área (Figura 10)

da camada de remanescentes adesivos foram significativamente menores após

o uso das brocas de baixa rotação (p<0,05). Estudos30,38,44 relatam que a

realização do clean-up com brocas de baixa rotação é um procedimento mais

seguro, pois envolve uma menor perda de esmalte durante sua execução.

Bishara et al38 ainda relataram que a remoção dos remanescentes adesivos por

meio de brocas de alta rotação origina uma superfície de esmalte

significativamente mais rugosa do que pelo uso de brocas de baixa rotação.

Apesar de diversos estudos2,30,33,34,44,45 avaliarem as características de

Page 20: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

14

superfície do esmalte após a remoção dos remanescentes adesivos, não foi

encontrado na literatura nenhum estudo no qual foi avaliada a espessura da

camada de adesivo remanescente.

A menor quantidade possível de remanescentes após o clean-up, com

mínimas perdas de esmalte, deve ser almejada visando o reestabelecimento

dos tecidos dentários o mais próximo possível do seu estado original.

A Tomografia por Coerência Óptica apresenta grande potencial para uso

na pesquisa ortodôntica, e além disso, pode se tornar uma ferramenta muito útil

na prática clínica, pois o aparelho é capaz de avaliar as estruturas dentárias em

tempo real, de forma não invasiva, superficialmente (3D) e em profundidade

(2D). No entanto, mais estudos são necessários para se aperfeiçoar a técnica,

e assim, possibilitar o uso clínico desta tecnologia.

Conclusões

Por meio da analise da estrutura dentária com o OCT, após os

procedimentos de descolagem de brackets e clean-up, observou-se que:

1. O tipo de alicate (ACA ou ARBA) ou de bracket (metálico ou cerâmico)

utilizados não influenciam a quantidade de remanescentes adesivos sobre o

esmalte após descolagem;

2. Áreas de fraturas de esmalte e de fragmentos de brackets foram

observadas somente nas amostras com brackets cerâmicos, sendo que o tipo

de alicate (ACA ou ARBA) não influencia a quantidade de fragmentos

cerâmicos ou na extensão das áreas de fratura do esmalte;

3. O uso de brocas em baixa rotação permite uma remoção mais efetiva

dos remanescentes adesivos durante os procedimentos de cleanup.

Page 21: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

15

REFERENCES

1. Pont HB, Ozcan M, Bagis B, Ren Y. Loss of surface enamel after bracket debonding: an in-vivo and ex-vivo evaluation. Am J Orthod Dentofacial Orthop 2010;138:387 e381-389; discussion 387-389. 2. Zarrinnia K, Eid NM, Kehoe MJ. The effect of different debonding techniques on the enamel surface: an in vitro qualitative study. Am J Orthod Dentofacial Orthop 1995;108:284-293. 3. Banerjee A, Paolinelis G, Socker M, McDonald F, Watson TF. An in vitro investigation of the effectiveness of bioactive glass air-abrasion in the 'selective' removal of orthodontic resin adhesive. Eur J Oral Sci 2008;116:488-492. 4. Campbell PM. Enamel surfaces after orthodontic bracket debonding. Angle Orthod 1995;65:103-110. 5. Tufekci E, Merrill TE, Pintado MR, Beyer JP, Brantley WA. Enamel loss associated with orthodontic adhesive removal on teeth with white spot lesions: an in vitro study. Am J Orthod Dentofacial Orthop 2004;125:733-739. 6. Knosel M, Mattysek S, Jung K, Sadat-Khonsari R, Kubein-Meesenburg D, Bauss O et al. Impulse debracketing compared to conventional debonding. Angle Orthod 2010;80:1036-1044. 7. Karan S, Kircelli BH, Tasdelen B. Enamel surface roughness after debonding. Angle Orthod 2010;80:1081-1088. 8. Fujimoto JG. Optical coherence tomography for ultrahigh resolution in vivo imaging. Nat Biotechnol 2003;21:1361-1367. 9. Bouma BE, GJ T. Handbook of optical coherencetomography. New York: Marcel Dekker; 2002. 10. Bizheva K, Povazay B, Hermann B, Sattmann H, Drexler W, Mei M et al. Compact, broad-bandwidth fiber laser for sub-2-microm axial resolution optical coherence tomography in the 1300-nm wavelength region. Opt Lett 2003;28:707-709. 11. Schmitt JM, Yadlowsky MJ, Bonner RF. Subsurface imaging of living skin with optical coherence microscopy. Dermatology 1995;191:93-98. 12. Raffel OC, Akasaka T, Jang IK. Cardiac optical coherence tomography. Heart 2008;94:1200-1210. 13. Mogensen M, Thrane L, Jorgensen TM, Andersen PE, Jemec GB. OCT imaging of skin cancer and other dermatological diseases. J Biophotonics 2009;2:442-451. 14. Hee MR, Puliafito CA, Wong C, Duker JS, Reichel E, Rutledge B et al. Quantitative assessment of macular edema with optical coherence tomography. Arch Ophthalmol 1995;113:1019-1029. 15. Colston BW, Jr., Everett MJ, Da Silva LB, Otis LL, Stroeve P, Nathel H. Imaging of hard- and soft-tissue structure in the oral cavity by optical coherence tomography. Appl Opt 1998;37:3582-3585. 16. Colston B, Sathyam U, Dasilva L, Everett M, Stroeve P, Otis L. Dental OCT. Opt Express 1998;3:230-238. 17. Braz AK, Kyotoku BB, Gomes AS. In vitro tomographic image of human pulp-dentin complex: optical coherence tomography and histology. J Endod 2009;35:1218-1221. 18. Feldchtein F, Gelikonov V, Iksanov R, Gelikonov G, Kuranov R, Sergeev A et al. In vivo OCT imaging of hard and soft tissue of the oral cavity. Opt Express 1998;3:239-250.

Page 22: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

16

19. Maia AM, Fonseca DD, Kyotoku BB, Gomes AS. Characterization of enamel in primary teeth by optical coherence tomography for assessment of dental caries. Int J Paediatr Dent 2010;20:158-164. 20. Baumgartner A, Dichtl S, Hitzenberger CK, Sattmann H, Robl B, Moritz A et al. Polarization-sensitive optical coherence tomography of dental structures. Caries Res 2000;34:59-69. 21. de Melo LS, de Araujo RE, Freitas AZ, Zezell D, Vieira ND, Girkin J et al. Evaluation of enamel dental restoration interface by optical coherence tomography. J Biomed Opt 2005;10:064027. 22. Braz AK, Aguiar CM, Gomes AS. Evaluation of the integrity of dental sealants by optical coherence tomography. Dent Mater 2011;27:e60-64. 23. Braz AK, Kyotoku BB, Braz R, Gomes AS. Evaluation of crack propagation in dental composites by optical coherence tomography. Dent Mater 2009;25:74-79. 24. de Melo Monteiro GQ, Montes MA, Rolim TV, de Oliveira Mota CC, de Barros Correia Kyotoku B, Gomes AS et al. Alternative methods for determining shrinkage in restorative resin composites. Dent Mater 2011;27:e176-185. 25. Garcez AS, Suzuki SS, Ribeiro MS, Mada EY, Freitas AZ, Suzuki H. Biofilm retention by 3 methods of ligation on orthodontic brackets: a microbiologic and optical coherence tomography analysis. Am J Orthod Dentofacial Orthop 2011;140:e193-198. 26. Baek JH, Na J, Lee BH, Choi E, Son WS. Optical approach to the periodontal ligament under orthodontic tooth movement: a preliminary study with optical coherence tomography. Am J Orthod Dentofacial Orthop 2009;135:252-259. 27. Houston WJ. The analysis of errors in orthodontic measurements. Am J Orthod 1983;83:382-390. 28. Midtgard J, Bjork G, Linder-Aronson S. Reproducibility of cephalometric landmarks and errors of measurements of cephalometric cranial distances. Angle Orthod 1974;44:56-61. 29. Rouleau BD, Jr., Marshall GW, Jr., Cooley RO. Enamel surface evaluations after clinical treatment and removal of orthodontic brackets. Am J Orthod 1982;81:423-426. 30. Zachrisson BU, Arthun J. Enamel surface appearance after various debonding techniques. Am J Orthod 1979;75:121-127. 31. Zachrisson BU, Skogan O, Hoymyhr S. Enamel cracks in debonded, debanded, and orthodontically untreated teeth. Am J Orthod 1980;77:307-319. 32. Odegaard J, Segner D. Shear bond strength of metal brackets compared with a new ceramic bracket. Am J Orthod Dentofacial Orthop 1988;94:201-206. 33. Alessandri Bonetti G, Zanarini M, Incerti Parenti S, Lattuca M, Marchionni S, Gatto MR. Evaluation of enamel surfaces after bracket debonding: an in-vivo study with scanning electron microscopy. Am J Orthod Dentofacial Orthop 2011;140:696-702. 34. Bishara SE, Trulove TS. Comparisons of different debonding techniques for ceramic brackets: an in vitro study. Part I. Background and methods. Am J Orthod Dentofacial Orthop 1990;98:145-153. 35. Scott GE. Fracture-Toughness and Surface Cracks - the Key to Understanding Ceramic Brackets. Angle Orthodontist 1988;58:5-8.

Page 23: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

17

36. Karamouzos A, Athanasiou AE, Papadopoulos MA. Clinical characteristics and properties of ceramic brackets: A comprehensive review. Am J Orthod Dentofacial Orthop 1997;112:34-40. 37. Bishara SE, Ostby AW, Laffoon J, Warren JJ. Enamel cracks and ceramic bracket failure during debonding in vitro. Angle Orthod 2008;78:1078-1083. 38. Bishara SE, Trulove TS. Comparisons of different debonding techniques for ceramic brackets: an in vitro study. Part II. Findings and clinical implications. Am J Orthod Dentofacial Orthop 1990;98:263-273. 39. Joseph VP, Rossouw E. The shear bond strengths of stainless steel and ceramic brackets used with chemically and light-activated composite resins. Am J Orthod Dentofacial Orthop 1990;97:121-125. 40. Winchester LJ. Bond strengths of five different ceramic brackets: an in vitro study. Eur J Orthod 1991;13:293-305. 41. Ghafari J. Problems associated with ceramic brackets suggest limiting use to selected teeth. Angle Orthod 1992;62:145-152. 42. Chen CS, Hsu ML, Chang KD, Kuang SH, Chen PT, Gung YW. Failure analysis: enamel fracture after debonding orthodontic brackets. Angle Orthod 2008;78:1071-1077. 43. Knox J, Jones ML, Hubsch P, Middleton J, Kralj B. An evaluation of the stresses generated in a bonded orthodontic attachment by three different load cases using the Finite Element Method of stress analysis. J Orthod 2000;27:39-46. 44. Hosein I, Sherriff M, Ireland AJ. Enamel loss during bonding, debonding, and cleanup with use of a self-etching primer. Am J Orthod Dentofacial Orthop 2004;126:717-724. 45. Krell KV, Courey JM, Bishara SE. Orthodontic bracket removal using conventional and ultrasonic debonding techniques, enamel loss, and time requirements. Am J Orthod Dentofacial Orthop 1993;103:258-266.

Page 24: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

18

FIGURAS

Figura 1

Figura 1. Representação esquemática da divisão dos grupos experimentais

Figura 2

Figura 2. Posicionamento e sistema de forças geradas pelo (A) Alicate de Corte de

Amarrilho (ACA) e pelo (B) Alicate de Remoção de Brackets Anteriores (ARBA).

Page 25: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

19

Figura 3

Figura 3. Imagens obtidas para mensuração das variáveis Área de

adesivo remanescente (RAd), Área de fratura de esmalte (setas), Área de fragmentos

de bracket (AFB); Esmalte (Esm).

Figura 4

Figura 4. Imagens utilizadas para mensuração das variáveis Profundidade da camada

de adesivo remanescente (PRA) em 4A e Área da camada de adesivo remanescente

(ARA) em 4B. Remanescente Adesivo (RAd); Esmalte (Esm).

Page 26: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

20

Figura 5

Figura 5. Intervalos de confiança e valores médios de área de

remanescente adesivo sobre o esmalte (%), segundo o tipo de bracket

(metálico e cerâmico).

Figura 6

Figura 6. Intervalos de confiança e valores médios de área de

fragmentos dos brackets sobre o esmalte, segundo as variáveis

bracket (metálico e cerâmico) e alicate (ACA e ARBA).

Page 27: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

21

Figura 7

Figura 7. Intervalos de confiança e valores médios de área de fratura de

esmalte, segundo as variáveis bracket (metálico e cerâmico) e alicate

(ACA e ARBA).

Figura 8

Figura 8. Frequência de fraturas de esmalte segundo as variáveis

bracket e alicate

Figura 9

Page 28: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

22

Figura 9. Intervalos de confiança e valores médios de Profundidade (um)

da camada de remanescente adesivo após clean-up

Figura 10

Figura 10. Intervalos de confiança e valores médios de

Área (um2) da camada de remanescente adesivo após clean-

up

Page 29: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

23

TABELAS

Tabela 1 – variância total, variância do erro, erro de Dalhberg, coeficiente de confiabilidade e coeficiente de correlação de Pearson para as mensurações realizadas.

MENSURAÇÃO VARIÂNCIA TOTAL

St2

VARIÂNCIA ERRO Se

2

ERRO DE DAHLBERG

(%)

COEF. CONFIAB.

(%)

COEF. CORREL.

(%)

Área Adesivo (%) 463,3082 10,0089 2,1603 97,8397 97,9241 Área Fragmento Bracket (%) 0,0000 0,0000 0,0000 100,0000 100,0000 Área Fratura Esmalte (%) 0,0000 0,0000 0,0000 100,0000 100,0000 Área camada remanescente (µm

2)

1,1091E+11 4,5599E+08 0,4111 99,5889 99,6375

Profundidade da camada remanescente. (µm)

3387,2622 0,2005 0,0059 99,9941 99,9946

Tabela 2 - Teste de comparações múltiplas de Games-Howell para a área de remanescente adesivo, segundo Bracket (metálico e cerâmico) e Alicate (ACA e ARBA).

(I) Bracket x Alicate

(J) Bracket x Alicate

Diferença média

Erro padrão

Valor p

Intervalo de confiança 95%

Limite inferior

Limite superior

Metálico/ACA Metálico/ ARBA 8.3467 6.0054 0.5113 -7.5884 24.2818

Cerâmico/ ACA -1.8123 3.8145 0.9641 -12.0355 8.4109

Cerâmico/ ARBA 2.5010 5.2726 0.9644 -11.4521 16.4541

Metálico/ARBA Metálico/ ACA -8.3467 6.0054 0.5113 -24.2818 7.5884

Cerâmico/ ACA -10.1590 5.1328 0.2153 -24.0056 3.6876

Cerâmico/ ARBA -5.8457 6.2925 0.7895 -22.5112 10.8199

Cerâmico/ ACA Metálico/ ACA 1.8123 3.8145 0.9641 -8.4109 12.0355

Metálico/ ARBA 10.1590 5.1328 0.2153 -3.6876 24.0056

Cerâmico/ ARBA 4.3133 4.2520 0.7421 -7.1133 15.7399

Cerâmico/ARBA Metálico/ ACA -2.5010 5.2726 0.9644 -16.4541 11.4521

Metálico/ ARBA 5.8457 6.2925 0.7895 -10.8199 22.5112

Cerâmico/ ACA -4.3133 4.2520 0.7421 -15.7399 7.1133

Page 30: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

24

LISTA DE ABREVIATURAS

TCO - Tomografia por Coerência Óptica

ACA - Alicate de Corte de Amarrilho

ARBA - Alicate para Remoção de Brackets Anteriores

RRes - Área de adesivo remanescente

FBC - Área de fragmentos de bracket

Esm – Esmalte

FBC – Fragmentos de Bracket

PPR - Profundidade da camada de adesivo remanescente

ARA - Área da camada de adesivo remanescente

PRA – Profundidade de Remanescente Adesivo

RAd - Remanescente Adesivo

Page 31: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

25

1. ARTIGO EM INGLÊS

Page 32: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

26

Characterization of the enamel and adhesive remaining after removal of

brackets by optical coherence tomography

Jorge César Borges Leão Filho, DDS Pontifícia Universidade Católica do Paraná, Curitiba, Brazil. School of Health and Biosciences Dentistry Graduate Program – Orthodontics Email: [email protected]

Ana Karla Souza Braz Universidade Federal de Pernambuco, Pernambuco, Recife, Brazil. Biomedical Engineering Postgraduate Program Email: [email protected] Corresponding author

Orlando Motohiro Tanaka, DDS, PhD Professor, Graduate Dentistry Program, Orthodontics Pontifícia Universidade Católica do Paraná, Curitiba, Brazil School of Health and Biosciences Postdoctoral Fellow in The Center for Advanced Dental Education at Saint Louis University Email: [email protected]

Page 33: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

27

ABSTRACT

Introduction: The aims of this study were (1) to quantitatively evaluate the

presence of adhesive remnants and fragments of brackets on enamel and of

enamel fractures after the debonding of metal and ceramic brackets; and (2) to

quantify the layer of adhesive remnants in depth after two different cleanup

procedures. Methods: Metal and ceramic brackets were bonded on 120 human

incisors and then debonded using two different techniques. The samples were

then submitted for enamel assessment with Optical Coherence Tomography

(OCT). In sequence, two different methods of removing the remaining adhesive

(tungsten carbide burs at high and low speed) were performed, and at the end

of these procedures, the remaining adhesive layer was measured with the OCT.

Results and conclusions: (1) The type of debonding technique (with side-

cutting pliers or anterior bracket removal pliers) and the type of bracket did not

influence the amount of adhesive remaining after debonding; (2) enamel

fractures were observed only in the samples bonded with ceramic brackets, and

the type of pliers did not influence the incidence and extent of enamel damage;

and (3) the low-speed burs were more effective in removing the remaining

adhesive.

Page 34: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

28

INTRODUCTION

The development of adhesive systems led to the creation of effective

methods for bonding orthodontic brackets on enamel surfaces. Although this

procedure facilitates the assembly of orthodontic appliances, there is a dilemma

in its use. The adhesion should be strong enough to prevent bond failure during

treatment but also weak enough so that the enamel damage would be non-

existent or minimal during bracket removal after treatment.1

The most used techniques for debonding brackets include the use of

pliers that rely on a combination of tensile and shear forces to promote three

types of failures: (1) adhesive failure between the adhesive and the base of the

bracket; (2) adhesive failure between the adhesive and the enamel; and (3)

cohesive failure between the molecules of the adhesive layer. There is a

cohesive failure within the tissue in regions with enamel fractures.1

Debonding evaluations are most often performed using an optical

microscope and scanning electronic microscope.5,6-10 Scanning, tunneling and

atomic force microscopy (STM and AFM) have also been explored for dental

surface analysis.11 However, all these techniques only perform surface analysis.

Optical Coherence Tomography (OCT) is a well-established low-coherence

inter-ferometric technique that performs high resolution, ultra fast, non-invasive,

cross-sectional (2D) and volumetric (3D) tomographic imaging of tissue

microstructures.12,13 It is analogous to ultrasound techniques but uses light

instead of sound waves to generate biological tissue images.2

OCT has been widely used for medical purposes,3-5 mainly in

ophthalmology.6 In dentistry, this technology has been applied to the anatomical

characterization of dental7-9 and periodontal structures,7 detection of incipient

caries,10-12 evaluation of dental materials13-15 and restorations,16 qualitative

marker of biofilm formed around the brackets17 and evaluation of periodontal

ligament responses under orthodontic forces.18 However, there are no reports in

the literature on the use of OCT for evaluating the enamel structure after

debonding orthodontic brackets and after removing the remaining adhesive.

Page 35: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

29

Therefore, the aims of this study were (1) to evaluate quantitatively the

presence of adhesive remnants and fragments of brackets on enamel and of

enamel fractures after the debonding of metal and ceramic brackets; (2) and to

quantify the layer of adhesive remnants in depth after two different cleanup

procedures.

MATERIALS AND METHODS

Tooth specimens

A total of 120 extracted human incisors acquired from a tooth bank of (the

name was omitted) and free from caries, cracks, abrasions and staining

(assessed by visual and OCT examination) were selected and stored in a 0.1%

thymol solution. The teeth were randomly divided into four groups (n=30)

according to the type of bonded brackets and the pliers used for debonding

(Table I). After debonding, each group was equally subdivided into two

subgroups (n=15), and for each subgroup, a different procedure was used for

removal of the adhesive remnants (low-speed and high-speed tungsten carbide

finishing bur). The experimental procedure using human teeth was submitted to

the Ethical Committee of the University and carried out in accordance with the

ethical guidelines for research with human participants.

Bonding procedure

Before the bonding procedure, the anterior surface of each tooth was

examined with an OCT (Ganymede/ Thorlabs) in a 3D and 2D mode to exclude

samples with any type of enamel damage. Then, for bonding of orthodontics

appliances, metallic brackets\Edgewise standard (American Orthodontics,

Sheboygan, USA) and ceramic brackets\Edgewise standard (Morelli, Sorocaba-

SP, Brazil) were used. The enamel surfaces were etched with 37% phosphoric

acid (Condac 37, FGM, Joinvile, Brazil) for 20 seconds, rinsed with water for 10

seconds and then air-dried. The bonding procedure was performed using the

Transbond Plus Color Change Adhesive System (3M Unitek, Monrovia USA)

according to the manufacturer’s instructions. The primer was used on the

enamel surface, while the adhesive resin was applied to the base of the

bracket. The brackets were positioned on the labial surface of the incisors, and

Page 36: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

30

with a dynamometer pressure of 400g was exerted on the bracket before curing

the adhesive, in order to standardize the thickness of the adhesive layer under

the bracket. The adhesive was light-cured for 20 seconds on the incisal and

cervical side of the bracket using Radii-Cal equipment (SDI Inc., Bensenville,

USA). After the bonding procedure, the samples were stored in distilled water

for 24 hours.

Debonding procedure

Debonding was carried out 24 hours after bonding using two different

pliers: (1) Side Cutter (SC) (Model i-552, Rocky Mountain Orthodontics, Denver,

USA); (2) Anterior Bracket Removal plier (ABR) (Model E-346, Piramid

Orthodontics, Corte Madera, USA). Although variations in the use of these

instruments are possible, debonding was performed in a standardized

procedure,19 as follows:

The SC was placed diagonally at the bracket base, at the cervical and

incisal parts. The bracket was removed by gentle squeezing of the pliers and an

additional clockwise rotational movement. (Figure 2,A).

The ABR was applied by gripping below the bracket wings at the bracket-

enamel interface. By closing and downward tipping of the pliers, a rotational

axis was created at the apical bracket margin, thereby releasing the bracket.

(Figure 2,B)

After bracket removal, the teeth were again examined by OCT and 3D

volumetric images were obtained (two 3D images for each tooth).

Quantification of the adhesive remaining (T1)

The images of adhesive remaining generated after the removal of the

brackets were processed using ImageJ (Version 1.44p, Wayne Rasband

National Institutes of Health, USA). With this software, the following

measurements were made: (1) adhesive remaining area, (2) enamel fracture

area; and (3) area of the bracket fragments (generated by brackets fracture

during debonding) (Figure 3). All of these measurements were converted into

percentages, according to the following equation:

Page 37: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

31

Cleanup procedure

Adhesive removal was carried out with two different types of burs: a high-

speed tungsten carbide finishing bur (Model CF375R, Beijing Smart

Technology, Beijing, China) and a low-speed tungsten carbide finishing bur

(Model CB27204, Beijing Smart Technology, Beijing, China). The cleanup was

performed by a single operator (J.L.), with the bur positioned parallel to the long

axis of the teeth and executed with horizontal movements. The procedure was

considered complete after visual and macroscopic observation of satisfactory

removal of the remnants. A new bur was used for each ten samples. After

cleanup, new readings using OCT in a 2D mode (cross-sectional images) were

performed.

Quantification of the adhesive remaining layer (T2)

The cross-sectional images (2D) of the adhesive remaining layer after

the cleanup procedure were processed with the ImageJ software. The following

measurements were made: (1) the greatest depth of the adhesive remaining

layer (μm); and (2) the area of adhesive remaining layer (μm2) (Figure 4).

OCT observation

In this study, a commercial spectral optical coherence tomography

system (Ganymede OCT/ Thorlabs) produced cross-sectional (2D) and

volumetric (3D) optical imaging. The system is based on the Michelson

interferometer set-up. It is connected to a preconfigured PC and the images are

obtained with a scanner probe. The base unit contains the super luminescent

diode (SLD) light source. The wavelength of the SLD is centered at 930nm, with

a spectral width of 100nm. With an A-scan rate of 29kHz, this system can

produce 29fps with 512 lines per frame and an axial resolution of 5μm.

Optical Coherence Tomography images were performed to evaluate the

surface of the intact enamel before bonding at T0 (2D and 3D), after bracket

removal at T1 (3D) and after residual resin removal at T2 (2D).

Statistical analysis

To identify differences in the mean values of the three measurements at

T1, (for variable brackets and pliers) we used a two-way ANOVA test (full

Page 38: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

32

factorial design, n=30). The homogeneity of variances among the four groups

was tested using the Levene's test. The comparison between groups after

ANOVA test was performed using the Games-Howell test for heterogeneous

variances because the Levene's test indicated heterogeneous variances for 3

variables. For the area of the bracket fragments and the enamel fracture area,

which showed constant values for metallic/SC and metallic/ABR, the ANOVA

test was used with a nonparametric Mann-Whitney U and Kruskal-Wallis test.

These tests led to the same conclusions as the parametric test.

We used a Chi-square test to identify whether there was a statistically

significant association between the frequency of enamel fractures and the

independent variables (bracket and pliers). The level of significance was set at

5%.

To identify differences in the mean depth and the area of adhesive

remaining layer at T2 for the different groups, the Kolmogorov-Smirnov test was

used to assess the normality of the data and a Levene’s test was used to

assess the homogeneity of variances. Because all the treatments were normally

distributed, we used a two-way ANOVA test and a full factorial design. Then,

the Games-Howell test was used for heterogeneous variances, and the Tukey

HSD test was used for homogeneous variances. The Pearson's linear

correlation test was used to compare the behavior of the variables analyzed at

T2.

We performed a Dahlberg's error test to analyze errors in methodology

for all measurements obtained in the present study.

RESULTS

Reproducibility power of measurements

Table 1 shows the total variance, the variance of the error, the error

variance relative to the total variance (Dahlberg error in %), as well as the

confiability coefficient and Pearson's correlation coefficient for the variables

measured. Ideally, the Dahlberg's error should not exceed 3% of the total

variance. The measurement is considered improper for cases where the error

variance is greater than 10%.20,21 In this study, the Dahlberg error did not

Page 39: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

33

exceed 2.16%, indicating that the evaluator acceptably reproduced the

measurements (Table 1).

Analysis of enamel and quantification of adhesive remaining after debonding

(T1)

Figure 5 shows the quantity of adhesive remaining on the enamel (%) for

the different brackets (metal and ceramic) and pliers (SC and ABR). Table 2

presents the results of the Games-Howell multiple comparison test for these

variables. It was found that although the metal brackets generated smaller

amounts of remaining adhesive than ceramic brackets regardless of the type of

pliers used for debonding, there was no statistically significant difference

between them (p> 0.05). Likewise, there was no statistically significant

difference (p> 0.05) between the SC and ABR groups, regardless of the type of

brackets. The ABR group values for the area of adhesive remaining was smaller

than for the SC group.

Figure 6 shows the area of bracket fragments for the different brackets

(ceramic and metallic) and pliers (SC and ABR). It was observed that fractures

occurred only in samples bonded with ceramic brackets and that the use of SC

resulted in a lower quantity of fragments. However, there was no statistically

significant difference in the area of bracket fragments produced by the use of

SC or ABR pliers (p> 0.05).

Figure 7 shows the area of the enamel fracture for the different brackets

(metal and ceramic) and pliers (SC and ABR). It was observed that the enamel

fracture occurred only in samples bonded with ceramic brackets and that the

use of SC pliers resulted in less extensive damage to the enamel. However,

there was no statistically significant difference in the extension of enamel

fractures produced by the use of SC or ABR pliers (p> 0.05).

Figure 8 shows the frequency of enamel fractures for the different

brackets and pliers. It was observed that the damage to the tooth tissue

occurred only after the debonding of ceramic brackets. The two debonding

techniques produced a statistically similar frequency of enamel fractures (p>

0.05).

Depth and area of the adhesive remaining layer after cleanup (T2)

Page 40: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

34

After removing the remaining adhesive, it was observed that the use of

low-speed burs led to an enamel surface with less adhesive residue when

compared to the use of high-speed burs, which was true for both the depth

(Figure 9) and the area (Figure 10) of the adhesive remaining layer (p <0.05).

The Pearson's linear correlation test showed a statistically significant correlation

(p <0.05, r = 0.7662) between the values measured (depth and area), indicating

that these two parameters can be used to quantify the adhesive remaining

layer.

DISCUSSION

The debonding of brackets is a procedure that creates a risk of damage

to the enamel in the form of cracks, scratches or tissue loss.29,30 The key to the

preservation of this tissue may be the use of techniques that prevent the

development of adhesive failures at the enamel-adhesive interface, leaving as

much adhesive on the tooth surface as possible.22 Knosel et al19 observed that

maintaining the structural integrity of the enamel after debonding coincides with

the presence of larger quantities of adhesive remaining.

The two pliers evaluated in this study generated large amounts of

remaining adhesive: 87.29 ± 1.89% for the SC and 80.96 ± 3.14% for the ABR

(Figure 1) groups. The amount of adhesive remaining was not significantly

different after the use of these two pliers (p> 0.05), a result which is in

agreement with the study by Knosel.19 These observations suggest that both

SC and ABR pliers may be used for debonding. SC and ABR pliers are

relatively safe for dental tissues because the high amounts of adhesive

remnants generated by both indicate adhesive failure at the bracket-adhesive

interface. However, contrary to these findings, Zarrinnia et al23 found that the

use of ABR promotes failures at the bracket-adhesive interface, while SC

promotes failures at the enamel-adhesive interface. However, because the

number of samples analyzed by Zarrinnia et al23 was small (n = 6), perhaps

these observations are not conclusive.

The debonding of ceramic brackets mainly occurs because of failure at

the enamel-adhesive interface.24 On the other hand, the debonding of metal

brackets leads to, in most cases, a failure at the interface between the adhesive

and the bracket base.1,33,34 In the present study, the type of bracket (metal or

Page 41: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

35

ceramic) did not significantly influence the amount of adhesive remaining on the

enamel after debonding (p> 0.05), indicating that there is a higher incidence of

failure at the adhesive-bracket interface for both types of brackets.

The ceramic brackets are extremely brittle, and therefore, a small amount

of energy can be enough to fracture them.25,26 Clinically, a bracket fracture

during debonding is undesirable because the presence of ceramic fragments on

the tooth hampers the polishing of the enamel.27,28 Factors such as bracket

design, debonding technique, amount of force applied and the presence of

defects in the bracket slots can influence the occurrence of fractures in ceramic

brackets during debonding.25,29 In this study, it was found that both SC and ABR

pliers produced statistically similar amounts of ceramic fragments on the

enamel after debonding procedures (p> 0.05) (Figure 6).

In this study, it was found that enamel fractures occurred only during the

debonding of ceramic brackets, revealing a greater risk of damage promoted by

this procedure compared to the debonding of metal brackets. Previous

studies30-32 indicated a higher likelihood of enamel fractures after the debonding

of ceramic brackets, which relates to the strong adhesion of ceramic brackets to

the enamel.

It was observed also that the type of pliers used for debonding did not

significantly affect both the extent (Figure 7) and the frequency (Figure 8) of

damage to the enamel because there were no statistically significant differences

between the area and frequency of damage produced by the use of SC or ABR

pliers (p> 0.05). These results are in agreement with Knosel et al,19 who

observed no statistically significant difference (p> 0.05) in the incidence of

enamel fractures after using ABR or SC pliers.

Chen et al33 found that the extent and incidence of enamel fractures are

not modified by tensile or shearing/twisting forces during the debonding of

brackets. This fact may explain the lack of significant differences in the extent of

the fracture area observed with SC and ABR pliers in this study. However, after

conducting a finite element study, Knox et al34 concluded that the enamel

fractures most likely occur after the use of torsional forces when compared to

pure shear forces. It must be remembered that, apart from the technique used

for debonding, the presence of cracks and structural defects in the enamel prior

Page 42: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

36

to bonding can also increase the risk of enamel fracture.29,32 The exclusion of

teeth with enamel damage in the present study minimizes this effect.

This is the first study to assess the amount of adhesive remaining, in

depth, after performing different cleanup procedures. In this study, the

measurement of the adhesive remnants layer depth was possible with the use

of OCT, which obtains cross-sectional images of dental structures in a real-time

and non-invasive way.

It was found that the use of burs at low speed more effectively removes

the adhesive remaining compared to burs at high speed because both the depth

(Figure 9) and the area (Figure 10) of the adhesive remaining layer was

significantly lower after the use of the low-speed burs (p <0.05). Studies29,35,36

report that cleanup with low-speed burs is a safer procedure because it involves

less enamel loss than high-speed burs.

Bishara et al29 also reported that the removal of the adhesive remaining

using high-speed burs results in a significantly rougher enamel surface than

using low-speed burs. Although many studies23,25,35-38 have evaluated the

characteristics of the enamel surface after cleanup procedures, no studies have

analyzed the thickness of the remaining adhesive layer after cleanup.

The lowest possible amount of adhesive remaining after the cleanup,

with minimum loss of enamel, should be the aim at the end of orthodontic

treatment with a fixed appliance. This re-establishes the dental tissues as close

to their original state as possible.

Optical coherence tomography technology has great potential for use in

orthodontic research, and can become a useful tool in clinical practice because

it is able to assess the dental hard tissues non-invasively, superficially (3D) and

in-depth (2D). However, more efforts are needed to improve the technique and

the device to enable the clinical use of this technology.

CONCLUSIONS

Through analysis of the tooth structure with OCT after debonding and

cleanup procedures, the following observations were made:

Page 43: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

37

1. The type of pliers (SC or ABR) or brackets (metal or ceramic) used did not

influence the amount of adhesive remaining on the enamel after debonding;

2. Areas of enamel fractures and bracket fragments were observed only in

samples bonded with ceramic brackets, and the type of pliers (SC or ABR) did

not influence the amount of ceramic fragments or the extent/incidence of

enamel damage;

3. The use of burs at low speed more effectively removed the adhesive remaining

during cleanup procedures.

Page 44: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

38

REFERENCES

1. Pont HB, Ozcan M, Bagis B, Ren Y. Loss of surface enamel after bracket debonding: an in-vivo and ex-vivo evaluation. Am J Orthod Dentofacial Orthop 2010;138:387 e381-389; discussion 387-389.

2. Bizheva K, Povazay B, Hermann B, Sattmann H, Drexler W, Mei M et al. Compact, broad-bandwidth fiber laser for sub-2-microm axial resolution optical coherence tomography in the 1300-nm wavelength region. Opt Lett 2003;28:707-709.

3. Schmitt JM, Yadlowsky MJ, Bonner RF. Subsurface imaging of living skin with optical coherence microscopy. Dermatology 1995;191:93-98.

4. Raffel OC, Akasaka T, Jang IK. Cardiac optical coherence tomography. Heart 2008;94:1200-1210.

5. Mogensen M, Thrane L, Jorgensen TM, Andersen PE, Jemec GB. OCT imaging of skin cancer and other dermatological diseases. J Biophotonics 2009;2:442-451.

6. Hee MR, Puliafito CA, Wong C, Duker JS, Reichel E, Rutledge B et al. Quantitative assessment of macular edema with optical coherence tomography. Arch Ophthalmol 1995;113:1019-1029.

7. Colston BW, Jr., Everett MJ, Da Silva LB, Otis LL, Stroeve P, Nathel H. Imaging of hard- and soft-tissue structure in the oral cavity by optical coherence tomography. Appl Opt 1998;37:3582-3585.

8. Colston B, Sathyam U, Dasilva L, Everett M, Stroeve P, Otis L. Dental OCT. Opt Express 1998;3:230-238.

9. Braz AK, Kyotoku BB, Gomes AS. In vitro tomographic image of human pulp-dentin complex: optical coherence tomography and histology. J Endod 2009;35:1218-1221.

10. Feldchtein F, Gelikonov V, Iksanov R, Gelikonov G, Kuranov R, Sergeev A et al. In vivo OCT imaging of hard and soft tissue of the oral cavity. Opt Express 1998;3:239-250.

11. Maia AM, Fonseca DD, Kyotoku BB, Gomes AS. Characterization of enamel in primary teeth by optical coherence tomography for assessment of dental caries. Int J Paediatr Dent 2010;20:158-164.

12. Baumgartner A, Dichtl S, Hitzenberger CK, Sattmann H, Robl B, Moritz A et al. Polarization-sensitive optical coherence tomography of dental structures. Caries Res 2000;34:59-69.

13. Braz AK, Aguiar CM, Gomes AS. Evaluation of the integrity of dental sealants by optical coherence tomography. Dent Mater 2011;27:e60-64.

14. Braz AK, Kyotoku BB, Braz R, Gomes AS. Evaluation of crack propagation in dental composites by optical coherence tomography. Dent Mater 2009;25:74-79.

15. de Melo Monteiro GQ, Montes MA, Rolim TV, de Oliveira Mota CC, de Barros Correia Kyotoku B, Gomes AS et al. Alternative methods for determining shrinkage in restorative resin composites. Dent Mater 2011;27:e176-185.

16. de Melo LS, de Araujo RE, Freitas AZ, Zezell D, Vieira ND, Girkin J et al. Evaluation of enamel dental restoration interface by optical coherence tomography. J Biomed Opt 2005;10:064027.

17. Garcez AS, Suzuki SS, Ribeiro MS, Mada EY, Freitas AZ, Suzuki H. Biofilm retention by 3 methods of ligation on orthodontic brackets: a microbiologic

Page 45: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

39

and optical coherence tomography analysis. Am J Orthod Dentofacial Orthop 2011;140:e193-198.

18. Baek JH, Na J, Lee BH, Choi E, Son WS. Optical approach to the periodontal ligament under orthodontic tooth movement: a preliminary study with optical coherence tomography. Am J Orthod Dentofacial Orthop 2009;135:252-259.

19. Knosel M, Mattysek S, Jung K, Sadat-Khonsari R, Kubein-Meesenburg D, Bauss O et al. Impulse debracketing compared to conventional debonding. Angle Orthod 2010;80:1036-1044.

20. Houston WJ. The analysis of errors in orthodontic measurements. Am J Orthod 1983;83:382-390.

21. Midtgard J, Bjork G, Linder-Aronson S. Reproducibility of cephalometric landmarks and errors of measurements of cephalometric cranial distances. Angle Orthod 1974;44:56-61.

22. Zachrisson BU, Skogan O, Hoymyhr S. Enamel cracks in debonded, debanded, and orthodontically untreated teeth. Am J Orthod 1980;77:307-319.

23. Zarrinnia K, Eid NM, Kehoe MJ. The effect of different debonding techniques on the enamel surface: an in vitro qualitative study. Am J Orthod Dentofacial Orthop 1995;108:284-293.

24. Odegaard J, Segner D. Shear bond strength of metal brackets compared with a new ceramic bracket. Am J Orthod Dentofacial Orthop 1988;94:201-206.

25. Bishara SE, Trulove TS. Comparisons of different debonding techniques for ceramic brackets: an in vitro study. Part I. Background and methods. Am J Orthod Dentofacial Orthop 1990;98:145-153.

26. Scott GE. Fracture-Toughness and Surface Cracks - the Key to Understanding Ceramic Brackets. Angle Orthodontist 1988;58:5-8.

27. Karamouzos A, Athanasiou AE, Papadopoulos MA. Clinical characteristics and properties of ceramic brackets: A comprehensive review. Am J Orthod Dentofacial Orthop 1997;112:34-40.

28. Bishara SE, Ostby AW, Laffoon J, Warren JJ. Enamel cracks and ceramic bracket failure during debonding in vitro. Angle Orthod 2008;78:1078-1083.

29. Bishara SE, Trulove TS. Comparisons of different debonding techniques for ceramic brackets: an in vitro study. Part II. Findings and clinical implications. Am J Orthod Dentofacial Orthop 1990;98:263-273.

30. Joseph VP, Rossouw E. The shear bond strengths of stainless steel and ceramic brackets used with chemically and light-activated composite resins. Am J Orthod Dentofacial Orthop 1990;97:121-125.

31. Winchester LJ. Bond strengths of five different ceramic brackets: an in vitro study. Eur J Orthod 1991;13:293-305.

32. Ghafari J. Problems associated with ceramic brackets suggest limiting use to selected teeth. Angle Orthod 1992;62:145-152.

33. Chen CS, Hsu ML, Chang KD, Kuang SH, Chen PT, Gung YW. Failure analysis: enamel fracture after debonding orthodontic brackets. Angle Orthod 2008;78:1071-1077.

34. Knox J, Jones ML, Hubsch P, Middleton J, Kralj B. An evaluation of the stresses generated in a bonded orthodontic attachment by three different load cases using the Finite Element Method of stress analysis. J Orthod 2000;27:39-46.

Page 46: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

40

35. Hosein I, Sherriff M, Ireland AJ. Enamel loss during bonding, debonding, and cleanup with use of a self-etching primer. Am J Orthod Dentofacial Orthop 2004;126:717-724.

36. Zachrisson BU, Arthun J. Enamel surface appearance after various debonding techniques. Am J Orthod 1979;75:121-127.

37. Krell KV, Courey JM, Bishara SE. Orthodontic bracket removal using conventional and ultrasonic debonding techniques, enamel loss, and time requirements. Am J Orthod Dentofacial Orthop 1993;103:258-266.

38. Alessandri Bonetti G, Zanarini M, Incerti Parenti S, Lattuca M, Marchionni S, Gatto MR. Evaluation of enamel surfaces after bracket debonding: an in-vivo study with scanning electron microscopy. Am J Orthod Dentofacial Orthop 2011;140:696-702.

Page 47: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

41

FIGURES

Figure 1

Figure 1. Schematic representation of the experimental groups

Figure 2

Figure 2. Positioning and forces generated by (A) SC and (B) ABR.

Page 48: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

42

Figure 3

Figure 3. Images obtained for the measurement of variables. Adhesive

Remaining Area (ARA), enamel fracture area (arrows), Bracket Fragments Area

(BFA), Enamel (En).

Figure 4

Figure 4. Images obtained for the measurement of variables. Adhesive

Remaining Layer Depth (ARLD) in 4A and Adhesive Remaining Layer Area

(ARLA) in 4B. Adhesive Remnant (AR), Enamel (En).

Page 49: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

43

Figure 5

Figure 5. Confidence intervals and the mean adhesive remaining area (%) on

the enamel according to the type of bracket (metal and ceramic) and type of

pliers (SC and ABR).

Figure 6

Figure 6. Confidence intervals and mean bracket fragment area (%) on the

enamel according to the type of bracket (metal and ceramic) and type of pliers

(SC and ABR).

Page 50: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

44

Figure 7

Figure 7. Confidence intervals and the mean enamel fracture area (%) on the

enamel according to the type of bracket (metal and ceramic) and type of pliers

(SC and ABR).

Figure 8

Figure 8. Incidence of enamel fractures according to the type of bracket (metal

and ceramic) and type of pliers (SC and ABR).

Page 51: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

45

Figure 9

Figure 9. Confidence intervals and the mean adhesive remaining layer depth

(µm) after cleanup.

Figure 10

Figure 10. Confidence intervals and the mean adhesive remaining layer area

(µm2) after cleanup.

Page 52: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

46

TABLES

Table 1 – The total variance, the variance of the error, the error variance relative to the total variance (Dahlberg error in %), the confiability coefficient and Pearson's correlation coefficient for the variables measured.

Mensurations Total

Variance St2

Error Variance Se

2

Dahlberg's Error (%)

Reliability Coefficient (%)

Correlation Coefficient (%)

Adhesive remaining area (%) 463.3082 10.0089 2.1603 97.8397 97.9241

Bracket fragments area (%) 0,0000 0,0000 0,0000 100 100

Enamel fracture area (%) 0,0000 0,0000 0,0000 100 1000 Adhesive Remaining Layer Area (µm

2)

1.1091E+15 4.5599E+12 0,4111 99.5889 99.6375

Adhesive Remaining Layer Depth (µm)

3387.2622 0,2005 0,0059 999941 999946

Table 2 - Games-Howell multiple comparison test for adhesive remaining on the enamel (%), according to brackets (metal and ceramic) and pliers (SC and ABR).

(I) Bracket x Plier (J) Bracket x Plier Mean

Difference Standard

Error p

Value

95% confidence interval

Lower Bound

Upper Bound

Metalic/SC Metalic/ABR 8.3467 6.0054 0.5113 -7.5884 24.282

Ceramic/SC -1.8123 3.8145 0.9641 -12.036 8.4109

Ceramic/ABR 2.501 5.2726 0.9644 -11.452 16.454

Metalic/ABR Metalic/SC -8.3467 6.0054 0.5113 -24.282 7.5884

Ceramic/SC -10.159 5.1328 0.2153 -24.006 3.6876

Ceramic/ABR -5.8457 6.2925 0.7895 -22.511 10.82

Ceramic/SC Metalic/SC 1.8123 3.8145 0.9641 -8.4109 12.036

Metalic/ABR 10.159 5.1328 0.2153 -3.6876 24.006

Ceramic/ABR 4.3133 4.252 0.7421 -7.1133 15.74

Ceramic/ABR Metalic/SC -2.501 5.2726 0.9644 -16.454 11.452

Metalic/ABR 5.8457 6.2925 0.7895 -10.82 22.511

Ceramic/SC -4.3133 4.252 0.7421 -15.74 7.1133

Page 53: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

47

LIST OF ABBREVIATIONS

OCT - Optical Coherence Tomography

SC – Side Cutter pliers

ABR – Anterior Bracket Removal pliers

ARA - Adhesive Remaining Area

BFA - Bracket Fragments Area

En – Enamel

ARLD - Adhesive Remaining Layer Depth

ARLA - Adhesive Remaining Layer Area

AR – Adhesive Remnant

Page 54: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

48

2. ANEXOS

Page 55: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

49

Anexo I - Parecer do Comitê de Ética em Pesquisa da PUCPR

Page 56: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

50

Anexo II – Análise Estatística

Efeito das variáveis Bracket e Alicate na Área de remanescente adesivo,

Área sem adesivo, Área de fragmento do bracket e Área de fratura de

esmalte.

Tabela 1 – Teste de homogeneidade de variâncias

Levene Statistic df1 df2 Valor p

Área Adesivo (%) Based on Mean 4.761 3 116 0.00363 Área sem Adesivo (%) Based on Mean 5.662 3 116 0.00118 Área Fragmento do Bracket (%) Based on Mean 14.442 1 58 0.00035

Área Fratura esmalte (%) Based on Mean 6.167 1 58 0.01593

Tabela 2 – Estatística descritiva das variáveis Área de remanescente adesivo, Área sem adesivo, Área de fragmento do bracket e Área de fratura de esmalte, segundo Bracket e Alicate.

N Mean Std.

Deviation Std. Error

95% Confidence Interval for Mean

Minimum Maximum

Lower Bound

Upper Bound

Área Adesivo (%) Metálico/ACA 30 86.38 19.08 3.48 79.26 93.51 17.74 100.00

Metálico/ARBA 30 78.03 26.79 4.89 68.03 88.04 4.61 100.00

Cerâmico/ACA 30 88.19 8.51 1.55 85.02 91.37 58.76 100.00

Cerâmico/ARBA 30 83.88 21.68 3.96 75.79 91.98 0.00 100.00

Total 120 84.12 20.27 1.85 80.46 87.79 0.00 100.00

Área sem Adesivo (%) Metálico/ACA 30 13.49 18.89 3.45 6.43 20.54 0.00 82.26

Metálico/ARBA 30 21.33 25.83 4.72 11.69 30.98 0.00 95.39

Cerâmico/ACA 30 6.14 7.53 1.37 3.33 8.95 0.00 41.24

Cerâmico/ARBA 30 7.28 18.07 3.30 0.53 14.02 0.00 100.00

Total 120 12.06 19.49 1.78 8.54 15.58 0.00 100.00

Área Fragmento do Bracket (%)

Metálico/ACA 30 0.00 0.00 0.00 0.00 0.00 0.00 0.00

Metálico/ARBA 30 0.00 0.00 0.00 0.00 0.00 0.00 0.00

Cerâmico/ACA 30 5.27 6.60 1.21 2.80 7.73 0.00 27.00

Cerâmico/ARBA 30 8.00 13.58 2.48 2.93 13.07 0.00 40.00

Total 120 3.32 8.22 0.75 1.83 4.80 0.00 40.00

Área Fratura esmalte (%)

Metálico/ACA 30 0.00 0.00 0.00 0.00 0.00 0.00 0.00

Metálico/ARBA 30 0.00 0.00 0.00 0.00 0.00 0.00 0.00

Cerâmico/ACA 30 0.10 0.55 0.10 -0.10 0.30 0.00 3.00

Cerâmico/ARBA 30 0.60 2.28 0.42 -0.25 1.45 0.00 9.00

Total 120 0.18 1.19 0.11 -0.04 0.39 0.00 9.00

Page 57: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

51

Tabela 3 – Teste de comparações múltiplas de Games-Howell para variâncias heterogêneas para a Área de Adesivo (%), segundo as variáveis Bracket e Alicate.

(I) Bracket x Alicate

(J) Bracket x Alicate

Mean Difference

(I-J) Std. Error Valor p

95% Confidence Interval

Lower Bound

Upper Bound

Metálico/ACA Metálico/ARBA 8.3466667 6.0054442 0.51126 -7.588425 24.281759

Cerâmico/ACA -1.8123333 3.8144530 0.96413 -12.035547 8.410881

Cerâmico/ARBA 2.5010000 5.2725612 0.96443 -11.452110 16.454110

Metálico/ARBA Metálico/ACA -8.3466667 6.0054442 0.51126 -24.281759 7.588425

Cerâmico/ACA -10.1590000 5.1327525 0.21527 -24.005559 3.687559

Cerâmico/ARBA -5.8456667 6.2924556 0.78946 -22.511231 10.819898

Cerâmico/ACA Metálico/ACA 1.8123333 3.8144530 0.96413 -8.410881 12.035547

Metálico/ARBA 10.1590000 5.1327525 0.21527 -3.687559 24.005559

Cerâmico/ARBA 4.3133333 4.2520218 0.74206 -7.113257 15.739923

Cerâmico/ARBA Metálico/ACA -2.5010000 5.2725612 0.96443 -16.454110 11.452110

Metálico/ARBA 5.8456667 6.2924556 0.78946 -10.819898 22.511231

Cerâmico/ACA -4.3133333 4.2520218 0.74206 -15.739923 7.113257

Tabela 4 – Teste de comparações múltiplas de Games-Howell para variâncias heterogêneas para a Área de fragmento do bracket (%), segundo as variáveis Bracket e Alicate.

(I) Bracket x Alicate

(J) Bracket x Alicate

Mean Difference

(I-J)

Std. Error

Valor p

95% Confidence Interval

Lower Bound

Upper Bound

Metálico/ACA Metálico/ARBA .00000 .00000 1.00000 .0000 .0000

Cerâmico/ACA -5,26667* 1.20529 0.00080 -8.5505 -1.9828

Cerâmico/ARBA -8,00000* 2.47888 0.01547 -14.7537 -1.2463

Metálico/ARBA Metálico/ACA .00000 .00000 1.00000 .0000 .0000

Cerâmico/ACA -5,26667* 1.20529 0.00080 -8.5505 -1.9828

Cerâmico/ARBA -8,00000* 2.47888 0.01547 -14.7537 -1.2463

Cerâmico/ACA Metálico/ACA 5,26667* 1.20529 0.00080 1.9828 8.5505

Metálico/ARBA 5,26667* 1.20529 0.00080 1.9828 8.5505

Cerâmico/ARBA -2.73333 2.75636 0.75495 -10.1066 4.6399

Cerâmico/ARBA Metálico/ACA 8,00000* 2.47888 0.01547 1.2463 14.7537

Metálico/ARBA 8,00000* 2.47888 0.01547 1.2463 14.7537

Cerâmico/ACA 2.73333 2.75636 0.75495 -4.6399 10.1066

Page 58: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

52

Tabela 5 – Teste de comparações múltiplas de Games-Howell para variâncias heterogêneas para a Área de fratura de esmalte(%), segundo as variáveis Bracket e Alicate.

(I) Bracket x Alicate (J) Bracket x

Alicate

Mean Difference

(I-J)

Std. Error

Valor p 95% Confidence Interval

Lower Bound Upper Bound

Metálico/ACA Metálico/ARBA .00000 .00000 1.00000 .0000 .0000

Cerâmico/ACA -.10000 .10000 0.75058 -.3725 .1725

Cerâmico/ARBA -.60000 .41689 0.48603 -1.7358 .5358

Metálico/ARBA Metálico/ACA .00000 .00000 1.00000 .0000 .0000

Cerâmico/ACA -.10000 .10000 0.75058 -.3725 .1725

Cerâmico/ARBA -.60000 .41689 0.48603 -1.7358 .5358

Cerâmico/ACA Metálico/ACA .10000 .10000 0.75058 -.1725 .3725

Metálico/ARBA .10000 .10000 0.75058 -.1725 .3725

Cerâmico/ARBA -.50000 .42871 0.65194 -1.6609 .6609

Cerâmico/ARBA Metálico/ACA .60000 .41689 0.48603 -.5358 1.7358

Metálico/ARBA .60000 .41689 0.48603 -.5358 1.7358

Cerâmico/ACA .50000 .42871 0.65194 -.6609 1.6609

Frequência de danos ao esmalte após a descolagem

Tabela 6 – Frequência ocorrida e esperada de fratura de esmalte

Bracket Total

Metálico Cerâmico

Área Fratura esmalte (%)

Ausente Count 60 57 117

Expected Count 58.5 58.5 117.0

% within Área Fratura esmalte (%)

51.3% 48.7% 100.0%

Presente Count 0 3 3

Expected Count 1.5 1.5 3.0

% within Área Fratura esmalte (%)

0.0% 100.0% 100.0%

Total Count 60 60 120

Expected Count 60.0 60.0 120.0

% within Área Fratura esmalte (%)

50.0% 50.0% 100.0%

Page 59: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

53

Tabela 7 – Teste do Qui-Quadrado para análise da frequência de danos ao esmalte

Value df Valor p

Pearson Chi-Square 3,077a 1

0.0794 Continuity Correction

b 1.368 1

0.2422 Fisher's Exact Test

0.2437 N of Valid Cases 120

a. 2 cells (50,0%) have expected count less than 5. The minimum expected count is 1,50.

b. Computed only for a 2x2 table

Efeito das variáveis Alicate e Broca na área e profundidade de

remanescente adesivo

Tabela 8 – Teste de homogeneidade de variâncias

Alicate x Broca

Kolmogorov-Smirnov

Statistic df Valor p

Profundidade (µm) ACA/Alta Rotação .109 15 0.20000

ACA/Baixa Rotação .192 15 0.14191

ARBA/Alta Rotação .126 15 0.20000

ARBA/Baixa Rotação

.210 15 0.07473

Área (µm2) ACA/Alta Rotação .164 15 0.20000

ACA/Baixa Rotação .199 15 0.11350

ARBA/Alta Rotação .200 15 0.10804

ARBA/Baixa Rotação

.186 15 0.17480

Tabela 9 – Estatística descritiva das variáveis Profundidade da camada de remanescentes (µm) e Área de da camada de remanescentes (µm

2), segundo Bracket e Alicate.

N Mean

Std. Deviation

Std. Error

95% Confidence Interval for Mean

Minimum Maximum

Lower Bound

Upper Bound

Profundidade (µm) Alta Rotação 30 109.12 65.63 11.98 84.61 133.62 0.00 232.85

Baixa Rotação 30 65.69 56.03 10.23 44.77 86.61 0.00 247.29

Total 60 87.40 64.34 8.31 70.79 104.02 0.00 247.29

Área (µm2) Alta Rotação 30 495941.53 502846.51 91806.79 308175.56 683707.51 0.00 2322638.00

Baixa Rotação 30 133685.20 129264.68 23600.39 85416.98 181953.43 0.00 481933.00

Total 60 314813.37 407260.38 52577.09 209606.86 420019.88 0.00 2322638.00

Page 60: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

54

Tabela 10 – Teste de comparações múltiplas de Tukey HSD para variâncias heterogêneas para a Profundidade da camada de remanescentes (µm), segundo as variáveis Bracket e Alicate

(I) Alicate x Broca (J) Alicate x Broca Mean

Difference (I-J)

Std. Error

Valor p

95% Confidence Interval

Lower Bound

Upper Bound

ACA/Alta Rotação ACA/Baixa Rotação 66,98267* 21.94613 0.01773 8.8718 125.0936

ARBA/Alta Rotação 4.73667 21.94613 0.99641 -53.3742 62.8476

ARBA/Baixa Rotação 24.60267 21.94613 0.67820 -33.5082 82.7136

ACA/Baixa Rotação ACA/Alta Rotação -66,98267* 21.94613 0.01773 -125.0936 -8.8718

ARBA/Alta Rotação -62,24600* 21.94613 0.03130 -120.3569 -4.1351

ARBA/Baixa Rotação -42.38000 21.94613 0.22695 -100.4909 15.7309

ARBA/Alta Rotação ACA/Alta Rotação -4.73667 21.94613 0.99641 -62.8476 53.3742

ACA/Baixa Rotação 62,24600* 21.94613 0.03130 4.1351 120.3569

ARBA/Baixa Rotação 19.86600 21.94613 0.80211 -38.2449 77.9769

ARBA/Baixa Rotação ACA/Alta Rotação -24.60267 21.94613 0.67820 -82.7136 33.5082

ACA/Baixa Rotação 42.38000 21.94613 0.22695 -15.7309 100.4909

ARBA/Alta Rotação -19.86600 21.94613 0.80211 -77.9769 38.2449

Tabela 11 – Teste de comparações múltiplas de Tukey HSD para variâncias heterogêneas para a Área da camada de remanescentes (µm), segundo as variáveis Bracket e Alicate

(I) Alicate x Broca (J) Alicate x

Broca Mean

Difference (I-J) Std. Error Valor p

95% Confidence Interval

Lower Bound Upper Bound

ACA/Alta Rotação ACA/Baixa Rotação

485861.72889 152823.99427 0.02866 44844.8617 926878.5961

ARBA/Alta Rotação

150866.93333 184675.74644 0.84591 -356753.0433 658486.9099

ARBA/Baixa Rotação

389517.86667 154813.51258 0.09622 -54683.8099 833719.5432

ACA/Baixa Rotação ACA/Alta Rotação

-4.85862E+05 152823.99427 0.02866 -926878.5961 -44844.8617

ARBA/Alta Rotação

-3.34995E+05 110063.09642 0.03565 -650632.2013 -19357.3898

ARBA/Baixa Rotação

-9.63439E+04 44451.96900 0.15952 -218433.4129 25745.6885

ARBA/Alta Rotação ACA/Alta Rotação

-1.50867E+05 184675.74644 0.84591 -658486.9099 356753.0433

ACA/Baixa Rotação

334994.79556 110063.09642 0.03565 19357.3898 650632.2013

ARBA/Baixa Rotação

238650.93333 112809.28883 0.18764 -81765.8128 559067.6795

ARBA/Baixa Rotação

ACA/Alta Rotação

-3.89518E+05 154813.51258 0.09622 -833719.5432 54683.8099

ACA/Baixa Rotação

96343.86223 44451.96900 0.15952 -25745.6885 218433.4129

ARBA/Alta Rotação

-2.38651E+05 112809.28883 0.18764 -559067.6795 81765.8128

Page 61: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

55

Tabela 12 – Teste de correlação linear de Pearson entre as variáveis Profundidade da camada de remanescentes (µm) e Área de da camada de

remanescentes (µm2)

Profundidade

(um) Área (um2)

Profundidade (um) Pearson Correlation 1 ,766**

Valor p

0.00000

N 60 60

Área (um2) Pearson Correlation ,766** 1

Valor p 0.00000

N 60 60

Gráfico 1 - Correlação linear de Pearson para as variáveis Profundidade da camada de

remanescentes (µm) e Área de da camada de remanescentes (µm2)

Page 62: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

56

Anexo III – Metodologia estendida

Procedimentos de colagem

Figura 1 – A, Incisivo hígido; B, Condicionamento ácido; C, Aplicação do sistema adesivo; D, Fotopolimerização; E, Procedimento de colagem finalizado.

Figura 2 - Dimamômetro Figura 3 – Posicionamento do

dimamômetro, previamente à

fotopolimetrização do cimento adesivo

Page 63: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

57

Procedimentos de leitura no OCT

Figura 4 – Amostra em posição durante realização de leitura no TCO

Page 64: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

58

Anexo IV – Normas para publicação – American Journal of Orthodontics

and Dentofacial Orthopedics

Information for Authors

Electronic manuscript submission and review

The American Journal of Orthodontics and Dentofacial Orthopedics uses the

Elsevier Editorial System (EES), an online manuscript submission and review

system.

To submit or review an article, please go to the AJO-DO EES website:

ees.elsevier.com/ajodo

Send other correspondence to:

Dr. Vincent G. Kokich, DDS, MSD, Editor-in-Chief American Journal of Orthodontics and Dentofacial Orthopedics University of Washington Department of Orthodontics, D-569 HSC Box 357446 Seattle, WA 98195-7446 Telephone (206) 221-5413 E-mail: [email protected] General Information

The American Journal of Orthodontics and Dentofacial Orthopedics publishes

original research, reviews, case reports, clinical material, and other material

related to orthodontics and dentofacial orthopedics.

Submitted manuscripts must be original, written in English, and not published or

under consideration elsewhere. Manuscripts will be reviewed by the editor and

consultants and are subject to editorial revision. Authors should follow the

guidelines below.

Statements and opinions expressed in the articles and communications herein

are those of the author(s) and not necessarily those of the editor(s) or publisher,

and the editor( s) and publisher disclaim any responsibility or liability for such

material. Neither the editor(s) nor the publisher guarantees, warrants, or

endorses any product or service advertised in this publication; neither do they

guarantee any claimmade by themanufacturer of any product or service. Each

reader must determine whether to act on the informationin this publication, and

neither the Journal nor its sponsoring organizations shall be liable for any injury

due to the publication of erroneous information.

Page 65: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

59

Guidelines for Original Articles

Submit Original Articles via EES: ees.elsevier.com/ajodo.

Before you begin, please review the guidelines below. To view a 7-minute video

explaining how to prepare your article for submission, go to Video on

Manuscript Preparation.

1. Title Page. Put all information pertaining to the authors in a separate

document. Include the title of the article, full name(s) of the author(s), academic

degrees, and institutional affiliations and positions; identify the corresponding

author and include an address, telephone and fax numbers, and an e-mail

address. This information will not be available to the reviewers.

2. Abstract. Structured abstracts of 200 words or less are preferred. A

structured abstract contains the following sections: Introduction, describing the

problem; Methods, describing how the study was performed; Results,

describing the primary results; and Conclusions, reporting what the authors

conclude from the findings and any clinical implications.

3. Manuscript. The manuscript proper should be organized in the following

sections: Introduction and literature review, Material and Methods, Results,

Discussion, Conclusions, References, and figure captions. Express

measurements in metric units, whenever practical. Refer to teeth by their full

name or their FDI tooth number. For style questions, refer to the AMA Manual of

Style, 9th edition. Cite references selectively, and number them in the order

cited. Make sure that all references have been mentioned in the text. Follow the

format for references in "Uniform Requirements for Manuscripts Submitted to

Biomedical Journals" (Ann Intern Med 1997;126:36-47); http://www.icmje.org

. Include the list of references with the manuscript proper. Submit figures and

tables separately (see below); do not embed figures in the word processing

document.

4. Figures. Digital images should be in TIF or EPS format, CMYK or grayscale,

at least 5 inches wide and at least 300 pixels per inch (118 pixels per cm).Do

Page 66: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

60

not embed images in a word processing program. If published, images could be

reduced to 1 column width (about 3 inches), so authors should ensure that

figures will remain legible at that scale. For best results, avoid screening,

shading, and colored backgrounds; use the simplest patterns available to

indicate differences in charts. If a figure has been previously published, the

legend (included in the manuscript proper) must give full credit to the original

source, and written permisson from the original publisher must be included. Be

sure you have mentioned each figure, in order, in the text.

5. Tables. Tables should be self-explanatory and should supplement, not

duplicate, the text. Number them with Roman numerals, in the order they are

mentioned in the text. Provide a brief title for each. If a table has been

previously published, include a footnote in the table giving full credit to the

original source and include written permission for its use from the copyright

holder. Submit tables as text-based files (Word or Excel, for example) and not

as graphic elements.

6. Model release and permission forms. Photographs of identifiable persons

must be accompanied by a release signed by the person or both living parents

or the guardian of minors. Illustrations or tables that have appeared in

copyrighted material must be accompanied by written permission for their use

from the copyright owner and original author, and the legend must properly

credit the source. Permission also must be obtained to use modified tables or

figures.

7. Copyright release. In accordance with the Copyright Act of 1976, which

became effective February 1, 1978, all manuscripts must be accompanied by

the following written statement, signed by all authors:

"The undersigned author(s) transfers all copyright ownership of the manuscript

[insert title of article here] to the American Association of Orthodontists in the

event the work is published. The undersigned author(s) warrants that the article

is original, does not infringe upon any copyright or other proprietary right of any

third party, is not under consideration by another journal, has not been

previously published, and includes any product that may derive from the

published journal, whether print or electronic media. I (we) sign for and accept

Page 67: CARACTERIZAÇÃO DO ESMALTE DENTÁRIO E REMANESCENTES

61

responsibility for releasing this material." Scan the printed copyright release and

submit it via EES.

8. Use the International College of Medical Journal Editors Form for the

Disclosure of Conflict of Interest (ICMJE Conflict of Interest Form). If the

manuscript is accepted, the disclosed information will be published with the

article. The usual and customary listing of sources of support and institutional

affiliations on the title page is proper and does not imply a conflict of interest.

Guest editorials, Letters, and Review articles may be rejected if a conflict of

interest exists.

Checklist for authors

Title page, including full name, academic degrees, and institutional affiliation

and position of each author, and author to whom correspondence and reprint

requests are to be sent, including address, business and home phone numbers,

fax numbers, and e-mail address

Abstract

Article proper, including references and figure legends

Figures, in TIF or EPS format

Tables

Copyright release statement, signed by all authors

Photographic consent statement(s)

ICMJE Conflict of interest statement

Permissions to reproduce previously published material