projeto elevatoria piranha predial não dá falta vazão
TRANSCRIPT
-
8/3/2019 PROJETO ELEVATORIA PIRANHA PREDIAL no d falta vazo
1/2
1
Type testedandmonitored
Compact aecal pumping unit or direct connection o one WC inaccordance with EN 12050-3. Suitable also or connection o awash-hand basin, shower and bidet.
ApplicationsThe Piranhamat 100/120 pumping unit has been designed orthe removal o euent rom a WC located below the sewerbackwash level or where the euent cannot ow by gravity into
a sewer. It is also possible to connect one wash-hand basin,one shower, and one bidet to the unit. Thanks to its compactdesign and the use o small bore piping, the Piranhamat100/120 pumping unit is suitable or installation in an existinghouse or during the renovation o old buildings.Where usage is by members o the public and cannot be moni-tored, or where more euent sources are to be connected,installation o the Sanimat series is recommended.
Construction* Modern, gas- and odour-tight white plastic tank o high qual-
ity synthetic material, resistant to all common toilet cleaninguids.
* Ready or use, and ftted with a powerul Piranha grinder
pump which is controlled automatically by the integral levelcontrol system.* Push-on, sel-sealing connection or a toilet at the rear o
the unit, and push-in connection ports or one wash-handbasin, one shower and one bidet at the sides. The dischargeconnection can be made on either side o the unit and meansthat the discharge pipe can exit let or right as is ound mostsuitable or the particular installation.
* Equipped with an electronic control unit with high level alarm(Piranhamat 120 with additional alarm buzzer).
* Non-return ap valve on the discharge line.* Maximum allowable temperature o the medium is 40 C; or
up to 60 C or a maximum o fve minutes.
The ABS Piranha pump itsel is ftted with a special shred-ding device that reduces the medium to a size that can easilybe pumped through a small bore pipe system o a size rom25-mm diameter. This ensures blockage-ree disposal o aecalmatter, toilet paper o various thicknesses, and also sanitaryarticles which might be accidentally dropped into the toilet.
* Compact unit ready to plug in and suitable or direct eurotoilet connection.
* With ABS patented Piranha cutting system or pumping aecalmatter and also sanitary articles that might be accidentlydropped into the toilet.
* Automatic level control and alarm.* Attractive corrosion-resistant synthetic tank.* Maintenance-riendly unit with easy access lid (no screws).* Carbon flter ftted to reduce odours.* Non-return valve and 2 m cable with Europlug supplied as
standard.
Installation
Features
ABS lifting station Piranhamat 100 and 120
1
0
0
1
2
3
4
5
6
7
8
9
1
2 3 4 5
2
6 87
H(m)
Q(m3/h)
(l/s)
50 Hz
Performance Curve
1. Backwash level2. Backwash loop with base above the backwash level
H = Total Head; Q = Discharge VolumeCurves to ISO 9906 (60z available on request)
-
8/3/2019 PROJETO ELEVATORIA PIRANHA PREDIAL no d falta vazo
2/2
160
197
DN2
5
DN3
2
DN 100
DN4
036
28
A
B
C
414
198*
180
287
80
110
140
* 74 mm or regions where regulations do notspeciy a higher minimum inow height.
A = AlarmB = OnC = O
Note:In the case o power ailure,by driving the rotor shat withan electric drill, the hydraulicsystem o the Piranhamat
100/120 will be operated andthe tank emptied.
Dimensions (mm)
Discharge Lines
* P1 = Power taken rom mains; P2 = Power at motor shat
DN 25
5
4
3
2
1
5
V (m)
H (m) 10 15 20 25 30 35 40
DN 32
Piranhamat 100 and 120
Motor power* (kW) P1 = 1.1 P2 = 0.68
Speed (r/min) 2900
Rated voltage (V) 220-240 1~
Rated current (A) 4.84
Cable length (m) 2.2
Cable type (H05V V-F) 3G1.0
Weight (kg) 9.0
Maximum pipe length allowable or the optimum unctioning othe unit. Allowance has been made or two 90 bends and one ABSnon-return valve.
V = Vertical discharge line lengthH = Horizontal discharge line length
Technical Data
2010-07-16
|Wereservetherightstoalterspecifca
tionsduetotechnicaldevelopments.