murphy manual de indicador

Upload: carlos-paez

Post on 03-Jun-2018

232 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/12/2019 Murphy manual de indicador

    1/12

    The

    POWERVIEWTM

    101display.

    P u r e S i m p l i c i t y.

    P V 1 0 1

  • 8/12/2019 Murphy manual de indicador

    2/12

    P V 1 0 1

    C O M P L E X E N G I N E SN E E D S I M P L E S O L U T I O N S

    What is your engine saying? With electronic engines, its hard to tell. Thats why the PowerView 101 displayis designed for pure simplicity.

    The PowerView 101 display translates standard J1939 fault codes into text descriptions. Then it displaysthem on a fully graphical, backlit LCD screen that can show up to four parameters simultaneously.

    With the PowerView 101, you get easy-to-read translation of engine/transmission parameters. You also getalarm and shutdown lights, plus detailed diagnostics. It collects all the complexity, and gives you a simplebut powerful view.

  • 8/12/2019 Murphy manual de indicador

    3/12

  • 8/12/2019 Murphy manual de indicador

    4/12

    The PowerView 101 disp lay is designed for the harshes t environments.Hot or cold. Wet or dry. Closed cab or open it doesnt matter.

    This is a smal l, so lid disp lay wi th a wide temperature range andtight environmental sealing. It doesnt take up a lot of dash space,but it delivers a ton of operator information.

    The PowerView 101 disp lay doesn t just translate data for the operator.It also delivers precise electronic engine and transmission datato your other instruments, such as gages or telemetry devices.

    Its accurate, reliable and rugged no matter where you take it.

    S I M P L Y S O L I D

  • 8/12/2019 Murphy manual de indicador

    5/12

    F E A T U R E S

    Fully graphical LCD screen

    Large, easy-to-read fault symbols

    Excellent viewing angle and contrast

    Four touch-sensitive buttons for scrolling and parameter

    selection

    Single or quadrant (4 parameter) views

    Displays active & stored diagnostic trouble codes (DTCs)*

    Displays standard or metric units

    Displays engine configuration*

    Modbus slave mode for remote communications

    Adjustable LED backlighting

    Ultra-bright alarm and shutdown LED indication

    Fuel sender or backlit dimmer input option

    Drives compatible analog gages

    Standard five languages per unit English, Spanish,

    French, German, Italian. Other languages available

    are Russian, Chinese, and Japanese.**

    * If supported by engine manufacturer.** Chinese and Japanese models have the option of two languages.

  • 8/12/2019 Murphy manual de indicador

    6/12

    Murphy completely reworked the installation process to make it simpler, quicker and easierthan ever. With our wire harnesses, the wiring is already tied to a standard connector. Wire harnessconnections are available for the major manufacturers' electronic engines.

    Simple connections ensure that you will be able to install them immediately with minimal training.

    We did the hard work for you. Just drop in the PowerView 101 display, plug in the harnesses and youreready to go. Its actually that simple.

    S I M P L Y I N S T A L L E D

    CONVENIENT INSTALLATION:

    < PowerView 101 display fits standard 2-1/16 in. (52 mm) hole opening

    < Powerview PVA and PVM Analog Gages in standard 2-1/16 in. (52 mm) and

    3-3/8 in. (86 mm) size hole openings, are available for easy installation with the PV101.

    (PVM gages are shown in the schematic to the right).

    < Two 6-pin Deutsch DT style connectors for PVA gages or two-AMP style connectors for

    PVM gages molded into casing for quick connections and simple daisy-chain wiring

    < Standard connection harnesses available

    < Standard and customizable panels available with harnesses for all major engine manufacturers

  • 8/12/2019 Murphy manual de indicador

    7/12

  • 8/12/2019 Murphy manual de indicador

    8/12

    4.30 in. (109 mm)

    Front Side Mounting

    2.51 in.(64 mm)2.06 in. (52 mm)

    Diameter

    D shaped hole for better

    alignment of the display

    Maximum

    panel thickness

    .375 in. (9.6 mm)

    3.48 in.

    (89 mm)

    D I M E N S I O N S

  • 8/12/2019 Murphy manual de indicador

    9/12

    T E C H N I C A L S P E C S

    DISPLAY: 1.3 x 2.6 in. (33 x 66 mm), 64 x 128 pixels.

    OPERATING VOLTAGE:. 6.5 VDC min. to 32 VDC max.. 8 VDC min. to 32 VDC max. with optional PVM gages.

    REVERSED POLARITY: Withstands reversed battery terminal polarity indefinitely within operating temperatures.

    OPERATING TEMPERATURE: -40 to +85C (-40 to 185F).

    DISPLAY VIEWING TEMPERATURE: -29 to +85C (-20 to 185F)

    STORAGE TEMPERATURE: -40 to +85C (-40 to 185F).

    ENVIRONMENTAL SEALING: IP68, +/- 5 PSI (+/- 34.4 kPa).

    POWER SUPPLY OPERATING CURRENT:. (@ 14 VDC) 52 mA min. 300 mA max.. (@ 32 VDC) 1 mA max. (with LCD heater).

    CAN BUS: SAE J1939 Compliant.

    CASE: Polycarbonate / Polyester.

    CLAMP: Polyester (PBT).

    CONNECTORS: 6-Pin Deutsch DT Series.

    AUXILIARY RS485 COMMUNICATIONS PORT:. 38.4K baud, N, 8, 1 or 2, half duplex. User configurable as MODBUS MASTER or MODBUS RTU SLAVE.. MASTER ACTIVE (default) drives optional PVA or PVM gages.. SLAVE ACTIVE offers user adjustable communication parameters.

    POTENTIOMETER/FUEL SENDER INPUT (RESISTIVE INPUT): 1K ohm, 1/4 W

    SHIPPING WEIGHTS (all models): 1b. (450 g.)

    SHIPPING DIMENSIONS (all models): 4-3/4in x 4-3/4in x 3-1/8in (121mm x 121mm x 79 mm).

  • 8/12/2019 Murphy manual de indicador

    10/12

    Analog gages (PVA and PVM)If you prefer a traditional panel, PowerView gages are the right choice.

    They show ECU data transmit ted by the PowerV iew in a t radi tional analog format.

    PowerView gages have a stepper motor operation with a 270 sweep, and accuracy that is better than 1.0% of scale.But theyre not just functional, they look sharp, too. These modern gages offer several design choices in lenses, bezel shapes and colors.

    The PVA model POWERVIEW gages feature slightly higher specs and design options. The PVM model POWERVIEW gages are designed for a smooth and cost-effectivetransition for lower horsepower electronic engines. Driven by the PowerView 101 display, the PVM gage combines durability, accuracy and attractive design.

    Audible Alarms (PVAA)The PowerVi ew Audi ble Alarm* alert s oper ator s to faul t conditio ns with a p iezoele ctr ic alar m and Form C rel ay contacts with a tempora ry sile nce butt on.* Audible alarm only available for use with PVA gages.

    The PowerV iew 101 Display can also be extended in several new ways. Addit ional analog gages, alarms

    and input/ouput modules bring even more equipment parameters into a single, convenient view.

    S I M P L Y C O M P A T I B L E

    AA BDB BB AB

  • 8/12/2019 Murphy manual de indicador

    11/12

    * Depending on gage type

    ** Remote gages refer to multiple instances of the same gage on the same bus.

    POWER SUPPLY

    5VDC (4.5-5, 5.5VDC min. & max. voltage) 12/24VDC (8-32VDC min. & max. voltage)

    POWER SUPPLY OPERATING CURRENT

    @ 14VDC: 28mA min., 52mA max. (excludes PVAA)

    @ 5VDC: 18mA min., 80mA CONNECTORSAMP Mini Universal Mate-N-Lock 6-Pin Deutsch DT06 series

    CAS E COLOR

    Black White

    BEZEL (ALL MODELS)

    A = A20 (Brushed Silver) AB = A20 (Black) B = Low profile SAE (Brushed Silver) BB = Low profile SAE (Black) C = Contemporary (Brushed Silver) CB = Contemporary (Black) D = Low Curved (Brushed Silver) DB = Low Curved (Black) E = Contemporary Domed (Brushed Silver) EB = Contemporary Domed (Glossy Black)

    LENS

    Flat Domed

    RTZ (RE T UR N T O ZERO )

    2 Gage 3.5 Gage

    PV101 COMPATIBILITY Maximum RS485 Harness Length (meters) 8.5

  • 8/12/2019 Murphy manual de indicador

    12/12

    F W M u r p h y5311 South 122nd East Avenue

    Tulsa, Oklahoma 74146 USA

    Phone: +1 918.317.4100 Fax: +1 918.317.4266

    E-mail: [email protected]

    Web site: www.fwmurphy.comF r a n k W . M u r p h y , L T D .Church Rd. Laverstock,

    Salisbury SP1 1QZ U.K.

    Phone: +44.1722.410055 Fax: +44.1722.410088

    E-mail: [email protected]

    Web site: www.fwmurphy.co.ukF W M u r p h y I n s t r u m e n t s ( H a n g z h o u ) C o . L T D .77 23rd Street

    Hangzhou Economic & Technological Development Area

    Hangzhou, Zhejiang, 310018, ChinaPhone: +86.571.8788.6060 Fax: +86.571.8684.8878

    E-mail: [email protected]

    0810293

    9-08

    EXPERIENCE EARNED.

    ENGINES UNDERSTOOD.