energy management: 2009/2010 - ulisboa · tarifa de venda a clientes finais em mÉdia e alta...

18
Energy Management: 2009/2010 Class# T05 Energy Prices, basics and dynamics Prof. Miguel Águas [email protected]

Upload: dangdung

Post on 11-Oct-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Energy Management: 2009/2010

Class# T05

Energy Prices, basics and dynamics

Prof. Miguel Á[email protected]

Energy management

ELECTRICITY

Class# T05: Energy Prices, basics and dynamics Slide 2 of 53

Energy management

National electricity generation

TECHNOLOGY DISAGREGATION (2006)

Power(MW)

Reservoirs RM 4.149 8%

Run-of-river RM 5.558 11%

LM 496 1%

4.582

Energy(GWh)

Hydric

TYPE

Class# T05: Energy Prices, basics and dynamics Slide 3 of 53

LM 496 1%

8.769 18% 3.175

Coal 14.070 28% 1.776

Fuel-oil + Gas-oil 1.501 3% 1.909

Natural gas 9.907 20% 2.166

44.450 89% 13.608

5.441 11%

49.891 100%

Source: REN (www.ren.pt)

Thermal

TOTAL PRODUCTION

Import balance

TOTAL DEMAND

Special generation (wind, cogeneration, etc)

Energy management

National electricity generation

Installed power: 4,9 GW

- Tapada do Outeiro (1,0 GW – Natural gas)

THERMAL POWER PLANTS

Class# T05: Energy Prices, basics and dynamics Slide 4 of 53

- Tapada do Outeiro (1,0 GW – Natural gas)

- Pego (0,6 GW – Coal)

- Ribatejo (1,2 GW – Natural gas)

- Setúbal (0,9 GW – Fuel-oil)

- Sines (1,2 GW – Coal)

Source: REN (www.ren.pt)

Under construction (natural gas)

Energy management

National electricity consumption

Weekly profile of electrical consumption

Class# T05: Energy Prices, basics and dynamics Slide 5 of 53

Source: Caraterização da rede Nacional de Transporte – 2007 – REN

Energy management

National electricity consumption

Hourly consumption profile

Class# T05: Energy Prices, basics and dynamics Slide 6 of 53

Source: Caraterização da rede Nacional de Transporte – 2007 – REN

Energy management

National electricity consumption

CONSUMPTION PER LEVEL OF VOLTAGE (2005)

Segment Voltage level

MAT - Very high voltage > 110 kV 1.302 3%

Annual consumption(GWh/year)

Class# T05: Energy Prices, basics and dynamics Slide 7 of 53

AT - High voltage > 45 kV 5.281 12%

MT - Medium voltage > 1 kV 13.567 31%

BT - Low voltage < 1 kV 0%

- BTE (> 41,4 kW) 3.291 8%

- BTN (< 41,4 kW) 19.044 43%

- Public lighting 1.299 3%

43.784 100%TOTAL CONSUMPTION

2005 Data. Source: ERSE (www.erse.pt)

Energy management

Electricity market liberalization

Regulated market:Fix tariffs per segment

Liberalized market:Tariffs flexibilityConsumption profile forecast is important

Class# T05: Energy Prices, basics and dynamics Slide 8 of 53

Consumers move to the liberalized market by:- Better price- Better commercial support

Regulated market tends to disapear:- UK : several years without regulated tariff- Spain: regulated tariff vanish in 2010- Portugal: ?

Energy management

Electricity market liberalization

Electricity cost in the liberalized market

The Supplier contracts electricity to be provided in 2 days, and informs the grid operator (REN) on the amount and hourly profile of the electricity that will be injected in the national grid:

Injected = Forecasted consumption + Grid losses

After the consumption, REN, calculated the effective

Class# T05: Energy Prices, basics and dynamics Slide 9 of 53

After the consumption, REN, calculated the effective consumption of the Supplier clients and charge by the deviation.

Deviation = Consumption + Grid losses – Injection

Additionally, the Supplier must pay for the use of the grid.

The price components are:

Cost = Production + Grid losses + Grid use

Energy management

Electricity market liberalization

Electricity spot market

Class# T05: Energy Prices, basics and dynamics Slide 10 of 53

Source: OMEL (www.omel.es)

Energy management

Electricity market liberalization

Current importance of the liberalized market in Portugal

Class# T05: Energy Prices, basics and dynamics Slide 11 of 53

Fonte: Resumo informativo Mercado Liberalizado em Dez/08 – ERSE (www.erse.pt)

Energy management

Regulated tariffs

Low voltage tariff structure

The bill has 2 components:

• Energy: The price depends on the Tariff type and Metering cycle

• Contrated power: Fix amount that depends of physical maximum power installed and Metering type

Contract options :• Contracted power (in kVA)

Class# T05: Energy Prices, basics and dynamics Slide 12 of 53

• Contracted power (in kVA)• Tariff type: Simples, Bi-horária e Tri-horária• Metring cycle (only for Bi-horária and Tri-horária): Daily cycle and weekly cycle

Energy management

Regulated tariffs

PERIODS IN DAILY AND WEEKLY CYCLE

Class# T05: Energy Prices, basics and dynamics Slide 13 of 53

Fonte: ERSE (www.erse.pt)

Energy management

Regulated tariffs

Tarifa simples Tarifa bi-horária Tarifa tri-horária

Potência (kVA)

3,45 5,65 7,76 7,76

4,6 7,32 9,96 9,96

5,75 8,99 12,15 12,15

6,9 10,66 14,35 14,35

10,35 15,44 20,55 20,55

(EUR/mês)

TARIFA DE VENDA A CLIENTES FINAIS EM BTN (<=20,7 kVA e >2,3 kVA)

Class# T05: Energy Prices, basics and dynamics Slide 14 of 53

Source: ERSE (www.erse.pt)

10,35 15,44 20,55 20,55

13,8 20,27 26,86 26,86

17,25 25,01 33,00 33,00

20,7 29,93 39,44 39,44

Energia activa

Tarifa simples 0,1211

Horas fora de vazio 0,1233

Horas de vazio 0,0663

Horas de ponta 0,1357

Horas de cheias 0,1198

Horas de vazio 0,0663

(EUR/kWh)

Energy management

Regulated tariffs

EXEMPLE: An house with tariff “simples” and Contract power of 6,9 kVA presented a month consumption of 150 kWh. a) What will be the bill of that month ? b) If the contract was in taridd “bi-horária”, what should be the % of the consumtion in off peak hours ?

TARIFA DE VENDA A CLIENTES FINAIS EM BTN (<=20,7 kVA e >2,3 kVA)

Class# T05: Energy Prices, basics and dynamics Slide 15 of 53

Tarifa simples Tarifa bi-horária Tarifa tri-horária

Potência (kVA)

3,45 5,65 7,76 7,76

4,6 7,32 9,96 9,96

5,75 8,99 12,15 12,15

6,9 10,66 14,35 14,35

10,35 15,44 20,55 20,55

13,8 20,27 26,86 26,86

17,25 25,01 33,00 33,00

20,7 29,93 39,44 39,44

Energia activa

Tarifa simples 0,1211

Horas fora de vazio 0,1233

Horas de vazio 0,0663

Horas de ponta 0,1357

Horas de cheias 0,1198

Horas de vazio 0,0663

(EUR/kWh)

(EUR/mês)Actual 10,66 + 200 x 0,1211 = 34,88 €

Bi-horária 14,35 + 200 x (0,1233 x (1-P)+ 0,0663 x P)

So Bi-horária < Actual ifP > 37%

Energy management

Tarifas reguladas

Estrutura da tarifa regulada de Média (alta e muito alta)Tensão

A factura tem três componentes como na BTN mas tem diferenças significativas (sublinhadas):

• Termo fixo: Geralmente desprezável• Energia: O preço unitário depende da Opção tarifária e do Ciclo de contagem

• Potência:

• Potência contratada: Depende da Potência tomada (máxima do mês medida em 15 minutos),

sendo a Potência contratada a máxima Potência tomada dos últimos 12 meses

• Potência em horas de ponta: Consumo em horas de ponta / N.º de horas de ponta do mês

Class# T05: Energy Prices, basics and dynamics Slide 16 of 53

• Potência em horas de ponta: Consumo em horas de ponta / N.º de horas de ponta do mês

• Energia reactiva: É uma “poluição” da rede eléctrica resultante do funcionamento de certos

equipamentos (motores eléctricos, lâmpadas fluorescentes, etc…). É facturada quando excede uma

certa proporção face à Energia consumida

Opções contratuais:• Opção tarifária: Curta, Média ou Longa utilização• Ciclos de contagem: Ciclo diário, ciclo semanal e ciclo semanal opcional

Nota 1: Os preços da energia mudam todos os trimestresNota 2: O Tipo de contagem não é uma opção contratual porque a contagem é sempre Tetra-horária (ponta, cheia, vazio normal e super vazio)

Energy management

Tarifas reguladasMédia tensão Alta tensão

Termo tarifário fixo (EUR/mês) (EUR/mês)

42,75 67,57

Potência (EUR/kW.mês) (EUR/kW.mês)

Tarifa de longas utilizaç ões Horas de ponta 7,395 4,543

Contratada 1,207 0,614

Tarifa de médias utilizações Horas de ponta 7,821 4,362

Contratada 1,046 0,465

Tarifa de curtas utilizações Horas de ponta 12,199 10,220

Contratada 0,407 0,296

Energia activa (EUR/kWh) (EUR/kWh)

Horas de ponta 0,1039 0,0820

Períodos I, IV Horas cheias 0,0791 0,0636

Horas de vazio normal 0,0501 0,0424

Tarifa de longas Horas de super vazio 0,0468 0,0396

utilizações Horas de ponta 0,1072 0,0821

Períodos II, III 0,0814 0,0660

TARIFA DE VENDA A CLIENTES FINAIS EM MÉDIA E ALTA TENSÃO

Class# T05: Energy Prices, basics and dynamics Slide 17 of 53

Fonte: ERSE (www.erse.pt)

Períodos II, III Horas cheias 0,0814 0,0660

Horas de vazio normal 0,0521 0,0449

Horas de super vazio 0,0485 0,0419

Horas de ponta 0,1095 0,0934

Períodos I, IV Horas cheias 0,0821 0,0660

Horas de vazio normal 0,0510 0,0457

Tarifa de médias Horas de super vazio 0,0478 0,0428

utilizações Horas de ponta 0,1155 0,0954

Períodos II, III Horas cheias 0,0825 0,0687

Horas de vazio normal 0,0539 0,0470

Horas de super vazio 0,0501 0,0434

Horas de ponta 0,1742 0,1141

Períodos I, IV Horas cheias 0,0903 0,0791

Horas de vazio normal 0,0576 0,0472

Tarifa de curtas Horas de super vazio 0,0539 0,0442

utilizações Horas de ponta 0,1746 0,1146

Períodos II, III Horas cheias 0,0901 0,0786

Horas de vazio normal 0,0578 0,0485

Horas de super vazio 0,0540 0,0448

Energy management

Tarifas reguladas

Média tensão Alta tensão

TARIFA DE VENDA A CLIENTES FINAIS EM MÉDIA E ALTA TENSÃO

EXEMPLO: Uma fábrica abastecida em Média tensão tem um contrato de Longas utilizações, apresentou em Março/09 uma Potência tomada de 1100 kW (valor máximo dos últimos 12 meses). O consumo de energia foi de Ponta=60 MWh, Cheia=150 GWh, VazioN=40 MWh e Svazio=30 MWh. Não havendo lugar à facturação de energia reactiva e considerando 120 horas de ponta nesse mês, calcule:a) Qual é a factura mensal ? b) Quanto pouparia a fábrica se estivesse a ser abastecida em Alta tensão ?

Fac.actual = 42,75 + 1,207x1100+ 7,395x(60.000/120)+0,1039x60.000+

Class# T05: Energy Prices, basics and dynamics Slide 18 of 53

Média tensão Alta tensão

Termo tarifário fixo (EUR/mês) (EUR/mês)

42,75 67,57

Potência (EUR/kW.mês) (EUR/kW.mês)

Tarifa de longas ut ilizaç ões Horas de ponta 7,395 4,543

Contratada 1,207 0,614

Tarifa de médias utilizações Horas de ponta 7,821 4,362

Contratada 1,046 0,465

Tarifa de curtas utilizações Horas de ponta 12,199 10,220

Contratada 0,407 0,296

Energia activa (EUR/kWh) (EUR/kWh)

Horas de ponta 0,1039 0,0820

Períodos I , IV Horas cheias 0,0791 0,0636

Horas de vazio normal 0,0501 0,0424

Tarifa de longas Horas de super vazio 0,0468 0,0396

utilizações Horas de ponta 0,1072 0,0821

Períodos I I, III Horas cheias 0,0814 0,0660

Horas de vazio normal 0,0521 0,0449

Horas de super vazio 0,0485 0,0419

Horas de ponta 0,1095 0,0934

7,395x(60.000/120)+0,1039x60.000+ 0,0791x150.000+0,0501x40.000+ 0,0468x30.000

=43+5.025+21.507=26.575 €

Fac.alta tensão= 67,57 + 0,614x1100+ 4,543x(60.000/120)+0,0820x60.000+ 0,0636x150.000+0,0424x40.000+ 0,0396x30.000

=68+2.947+17.344= 20.358 €

Poupança de 23%