Download - Planos Apple 2 2
-
8/12/2019 Planos Apple 2 2
1/33
-
8/12/2019 Planos Apple 2 2
2/33
-
8/12/2019 Planos Apple 2 2
3/33
-
8/12/2019 Planos Apple 2 2
4/33
-
8/12/2019 Planos Apple 2 2
5/33
-
8/12/2019 Planos Apple 2 2
6/33
-
8/12/2019 Planos Apple 2 2
7/33
27" SS27" SD
10" SS15" SD
10" SS18" SD
12" W
12" W
12" W
TELE
ELECTELE
ELEC
TELEGAS
P-6.01
Existing UtilitiesSouth
Client
Project
KeyPlan
Rev. Date Reason For Issue Chk
Project No. Date
Number Revision
A11020-1
Apple Inc.
Apple Campus 2
Title
Scale@Arch E1
Foster Partners 2010
www.arup.comTel(415)9579445 Fax(415)9579096SanFrancisco, CA 94105 USA560MissionStreet, Suite700
ArupNorth AmericaLtd.
06
N
04/12/13
00 08/09/11 PlannedDevelopment Permit
01 11/04/11 PlanningRevision
02 01/17/12 PlanningRevision
03 02/29/12 PlanningRevision
04 05/25/12 PlanningRevision
05 11/01/12 PlanningRevision
www.altaplanning.com
25609thStreet, Suite212Berkeley, CA94710
p:510.540.5008 f:510.540.5039
06 04/12/13 PlanningRevision
Existing On-siteUtilities Not Shown
1''=100'0' 200' 400' 600'
C a l a b a z a s
C r e e k
I n t e r s t a t e 2 8 0
Electrical
Telephone
Fire Service
Fiber Optic
Water
Sanitary Sewer
Gas
Storm Drain
Legend
SD
SS
TELE
Storm Drain
Sanitary Sewer
Telephone
ELEC Electric
W Water
Abbreviations
Survey Notes1. The types, locations, sizes and/or depths of existing underground
utilities as shown on this topographic and boundary survey wereobtained from sources of varying reliability. The contractor iscautioned that only actual excavation will reveal the types,extent, sizes, locations and depths of such underground utilities.(A reasonable effort has been made to locate and delineate allknow underground utilities.) However, the engineer can assumeno responsibility for the completeness or accuracy of itsdelineation of such underground utilities which may beencountered, but which are not shown on these drawings.
2. This map was prepared using computer assisted,photogrammetric methods by HJW GeoSpatial, Inc., in OaklandCalifornia. In areas of dense vegetation, accuracy of contoursmay deviate from accepted accuracy standards. The date of Photography was February 9, 2011 as Job No. 8502-026.
Existing Utilities - South01 1" = 100'
-
8/12/2019 Planos Apple 2 2
8/33
-
8/12/2019 Planos Apple 2 2
9/33
-
8/12/2019 Planos Apple 2 2
10/33
-
8/12/2019 Planos Apple 2 2
11/33
-
8/12/2019 Planos Apple 2 2
12/33
-
8/12/2019 Planos Apple 2 2
13/33
T I M E
Donot scale drawings. Dimensionsgovern.1.2
GeneralNotes
Alldimensionsare infeet and inches nlessnoted other ise
-
8/12/2019 Planos Apple 2 2
14/33
MATCHLINE, SEE P-7.11
Existing Trees
P-7.10
Landscape Plan - North
1"=100'
Apples
Landscape Plan - North01 1" = 100'
07
N o r t h
W o l f e R o a d
N o r t h T a n t a u A v e n u e
Client
Project
KeyPlan
Rev. Chk
S
D G N S P E C
Project No. Date
Number Revision
Alldimensionsshallbe verifiedonsite beforeproceedingwiththe work.Foster Partnersshallbe notifiedinwriting of anydiscrepancies.
2.3.
4.
5.Any areasindicatedon thissheet areapproximateandindicativeonly.
Alldimensionsare infeet and inchesunlessnoted otherwise.
1858
Title
Scale@ArchE1
Foster Partners 2010
ReasonForIssueDate
Apple Campus 2
www.arup.comTel(415)9579445 Fax(415)9579096SanFrancisco, CA 94105 USA560MissionStreet, Suite700
ArupNorth AmericaLtd.
Apple Inc.
N
www.altaplanning.com25609thStreet, Suite212
Berkeley, CA94710p:510.540.5008 f:510.540.5039
Architects Engineers ParkingPlannerswatrydesign.com
SanJose, CaliforniaNewport Beach, California
Austin, Texas
02 01/17/12 PlanningRevision
Visitor Entry
Apple Transit Center
Visitor and Auditorium Parking
Auditorium
Entry Meadow
Service Area
Parking Structure
Central Plant
Research and Development
Recreation Zone
Dining Terraces
The Glade
Interior Garden
Fountain
Perimeter Transplants
Evergreen Oak Trees
Canopy Trees
Plums
Apricots
Olives
03 02/29/12 PlanningRevision
04 05/25/12 PlanningRevision
Deciduous Oak Trees
Cherries and Flowering Trees
Conifers
Persimmons
05 Planning Revision11/01/12
Homestead Road
06 Planning Revision04/12/13
07 08/26/13 PlanningRevision
00 08/19/11 PlannedDevelopment Permit
08/19/2011
Potential Relocation of Glendenning Ban
MATCHLINE SEE P7 10S T I M E
Donot scale drawings. Dimensionsgovern.1.2.
GeneralNotes
Alldimensionsare infeet and inchesunlessnoted otherwise.
-
8/12/2019 Planos Apple 2 2
15/33
MATCHLINE, SEE P7.10
P-7.11
Landscape Plan - South
1"=100'
Client
Project
KeyPlan
Rev. Chk
S
D G N S P E C
Project No. Date
Number Revision
Alldimensionsshallbe verifiedonsite beforeproceedingwiththe work.Foster Partnersshallbe notifiedinwriting of anydiscrepancies.
3.
4.
5.Any areasindicatedon thissheet areapproximateandindicativeonly.
1858
Title
Scale@ArchE1
Foster Partners 2010
ReasonForIssueDate
Apple Campus 2
www.arup.comTel(415)9579445 Fax(415)9579096SanFrancisco, CA 94105 USA560MissionStreet, Suite700
ArupNorth AmericaLtd.
Apple Inc.
N
www.altaplanning.com25609thStreet, Suite212
Berkeley, CA94710p:510.540.5008 f:510.540.5039
Architects Engineers ParkingPlannerswatrydesign.com
SanJose, CaliforniaNewport Beach, California
Austin, Texas
Landscape Plan - South01 1" = 100'
07
02 01/17/12 PlanningRevision
N o r t h T a n t a u A v e n u e
I n t e r s t a t e 2 8 0
03 02/29/12 PlanningRevision
04 05/25/12 PlanningRevision
Visitor Entry
Apple Transit Center
Auditorium
Entry Meadow
Service Area
Parking Structure
Central Plant
Research and Development
Recreation Zone
Dining Terraces
The Glade
Interior Garden
Fountain
Conifers
Evergreen Oak Trees
Understory Trees
Plum Trees
Apricot Trees
Olive Transplants
Deciduous Oak Trees
Cherry and Flowering Trees
Apple Trees
Perimeter Transplants
Visitor & Auditorium Parking
Existing Trees
Persimmon Trees
05 11/01/12 PlanningRevision
06 04/12/13 PlanningRevision
07 08/26/13 PlanningRevision
08/19/2011
00 08/19/11 PlannedDevelopment Permit
S T I M E
Alldi i h llb ifi d it b f di
Donot scale drawings. Dimensionsgovern.1.2.3
GeneralNotes
Alldimensionsare infeet and inchesunlessnoted otherwise.
-
8/12/2019 Planos Apple 2 2
16/33
MATCHLINE, SEE P-7.13
Client
Project
KeyPlan
Rev. Chk
D G N S P E C
Project No. Date
Number Revision
Alldimensionsshallbe verifiedonsite beforeproceedingwiththe work.Foster Partnersshallbe notifiedinwriting of anydiscrepancies.
3.
4.
5.Any areasindicatedon thissheet areapproximateandindicativeonly.
1858
Title
Scale@ArchE1
Foster Partners 2010
ReasonForIssueDate
Apple Campus 2
www.arup.comTel(415)9579445 Fax(415)9579096SanFrancisco, CA 94105 USA560MissionStreet, Suite700
ArupNorth AmericaLtd.
Apple Inc.
N
www.altaplanning.com25609thStreet, Suite212
Berkeley, CA94710p:510.540.5008 f:510.540.5039
Architects Engineers ParkingPlannerswatrydesign.com
SanJose, CaliforniaNewport Beach, California
Austin, Texas
P-7.12
Planting Plan - NorthHerbaceous
1"=100'
Herbaceous Planting Plan - North01 1" = 100'
02 01/17/12 PlanningRevision
07
Conventional Turf/Lawn
Native Lawn With Bulbs & Wildflowers
Upland Grassland
Oak Woodland Understory
Edge Perennial Planting
Orchard Understory
Swales/Stormwater Areas
Redwood Understory
N o r t h
W o l f e R o a d
N o r t h T a n t a u A v e n u e
03 02/29/12 PlanningRevision
04 05/25/12 PlanningRevision
Riparian
Vines
05 07/10/12 PlanningRevision
06 Planning Revision
Valley Grassland
04/12/13
Homestead Road
07 08/26/13 PlanningRevision
08/19/2011
00 08/19/11 PlannedDevelopment Permit
Potential Relocationof Glendenning Barn
MATCHLINE, SEE S T I M E
Alldimensionsshallbe verifiedonsite beforeproceeding
Donot scale drawings. Dimensionsgovern.1.2.3.
GeneralNotes
Alldimensionsare infeet and inchesunlessnoted otherwise.
-
8/12/2019 Planos Apple 2 2
17/33
Client
Project
KeyPlan
Rev. Chk
D G N S P E C
Project No. Date
Number Revision
withthe work.Foster Partnersshallbe notifiedinwriting of anydiscrepancies.
4.
5.Any areasindicatedon thissheet areapproximateandindicativeonly.
1858
Title
Scale@ArchE1
Foster Partners 2010
ReasonForIssueDate
Apple Campus 2
www.arup.comTel(415)9579445 Fax(415)9579096SanFrancisco, CA 94105 USA560MissionStreet, Suite700
ArupNorth AmericaLtd.
Apple Inc.
N
www.altaplanning.com25609thStreet, Suite212
Berkeley, CA94710p:510.540.5008 f:510.540.5039
Architects Engineers ParkingPlannerswatrydesign.com
SanJose, CaliforniaNewport Beach, California
Austin, Texas
P-7.13
Planting Plan - SouthHerbaceous
1"=100'
Herbaceous Planting Plan - South01 1" = 100'
02 01/17/12 PlanningRevision
07
I n t e r s t a t e 2 8 0
N o r t h T a n t a u A v e n u e
03 02/29/12 PlanningRevision
04 05/25/12 PlanningRevision
05 07/10/12 PlanningRevision
06 Planning Revision
Conventional Turf/Lawn
Native Lawn With Bulbs & Wildflowers
Upland Grassland
Oak Woodland Understory
Edge Perennial Planting
Orchard Understory
Swales/Stormwater Areas
Redwood Understory
Riparian
Vines
Valley Grassland
04/12/13
07 Planning Revision08/26/13
0 0 P la nn ed D ev el op me nt P er mi t08/19/11
08/19/2011
Potential Relocationof Glendenning Barn
S T I M E
Alldimensionsshallbe verifiedonsite beforeproceedingwiththe work
Donot scale drawings. Dimensionsgovern.1.2.3.
GeneralNotes
Alldimensionsare infeet and inchesunlessnoted otherwise.
-
8/12/2019 Planos Apple 2 2
18/33
Client
Project
KeyPlan
Rev. Chk
D G N S P E C
Project No. Date
Number Revision
withthe work.Foster Partnersshallbe notifiedinwriting of anydiscrepancies.
4.
5.Any areasindicatedon thissheet areapproximateandindicativeonly.
1858
Title
Scale@ArchE1
Foster Partners 2010
ReasonForIssueDate
Apple Campus 2
www.arup.comTel(415)9579445 Fax(415)9579096SanFrancisco, CA 94105 USA560MissionStreet, Suite700
ArupNorth AmericaLtd.
Apple Inc.
N
www.altaplanning.com25609thStreet, Suite212
Berkeley, CA94710p:510.540.5008 f:510.540.5039
Architects Engineers ParkingPlannerswatrydesign.com
SanJose, CaliforniaNewport Beach, California
Austin, Texas
P-7.14
Planting ScheduleUnderstory andHerbaceousPlant Schedule - Species Under Review01 Not To Scale
07
ben
this
nF
90
.
.
n.c
alif , Caexas
yu
all
on
so
) 95 A
Ltd
.
m2
039
sig
, Cch, T
r o
sh
ted
Rea
41 U
700
ica
n
.cote211040.5
ryde
oseBeastin
e
nerss.
dicay.
Fax410
Suite
er
I
ning, Suit94710.5
watr
nJort Au
sc
artncies
sindonl
e
44 A
reet,
A
e
lanreet,CA f:5
Saewp
r a
r Ppan
reastive
ate
l
.com57
cisco,onStr
orth
l
ltapthSteley,008
N
n
t
lan
ster cre
ny aicat
D
.arup15)rancissio
N
w.a09terke40.5
r
ent
jec
yPl
v.
Fodis
.
.Anind
e
p
ww.el4an60M
rup
p
ww256
B10.5
Cli
Pro
Ke
Re
4
5.
Title
w
5
A
p:5
ievieRr nsiecepS-leudehcSle
tca
noS
lt T
Pot1
PlanningRevision
PlanningRevision
PlanningRevision
0 2 0 1/ 17 /1 2
0 3 0 2/ 29 /1 2
0 4 0 5/ 25 /1 2
0 5 0 7/ 10 /1 2
0 6 0 4/ 12 /1 3
PlanningRevision
PlanningRevision
08/09/2011
PlanningRevision0 2 1 1/ 04 /1 1
PlannedDevelopment Permit0 0 0 8/ 09 /1 1
07 07/31/13 PlanningRevision
S T I M E
Alldimensionsshallbe verifiedonsite beforeproceedingwiththe work.
Donot scale drawings. Dimensionsgovern.1.2.3.
GeneralNotes
Alldimensionsare infeet and inchesunlessnoted otherwise.
-
8/12/2019 Planos Apple 2 2
19/33
Client
Project
KeyPlan
Rev. Chk
D G N S P E C
Project No. Date
Number Revision
Foster Partnersshallbe notifiedinwriting of anydiscrepancies.
4.
5.Any areasindicatedon thissheet areapproximateandindicativeonly.
1858
Title
Scale@ArchE1
Foster Partners 2010
ReasonForIssueDate
Apple Campus 2
www.arup.comTel(415)9579445 Fax(415)9579096SanFrancisco, CA 94105 USA560MissionStreet, Suite700
ArupNorth AmericaLtd.
Apple Inc.
N
www.altaplanning.com25609thStreet, Suite212
Berkeley, CA94710p:510.540.5008 f:510.540.5039
Architects Engineers ParkingPlannerswatrydesign.com
SanJose, CaliforniaNewport Beach, California
Austin, Texas
P-7.15
Planting ScheduleTrees
Tree Schedule - Species Under Review01 Not To Scale
07
PlanningRevision
PlanningRevision
PlanningRevision
ivrednsieciepS-leudehle
cal
e S
e Tor
ot
0 2 0 1/ 17 /1 2
0 3 0 2/ 29 /1 2
0 4 0 5/ 25 /1 2
0 5 0 7/ 10 /1 2
0 6 0 4/ 12 /1 3
PlanningRevision
PlanningRevision
08/09/2011
PlanningRevision0 0 0 8/ 09 /1 1
PlanningRevision0 1 1 1/ 04 /1 1
PlanningRevision0 7 0 7/ 31 /1 3
S T I M E
Alldimensionsshallbe verifiedonsite beforeproceedingwiththe work.Foster Partnersshallbe notifiedinwriting of any
Donot scale drawings. Dimensionsgovern.1.2.3.
4
GeneralNotes
Alldimensionsare infeet and inchesunlessnoted otherwise.
-
8/12/2019 Planos Apple 2 2
20/33
P-7.16
Planting Palette
NTSPlanting PaletteNTS01
Client
Project
KeyPlan
Rev. Chk
D G N S P E C
Project No. Date
Number Revision
Foster Partnersshallbe notifiedinwriting of anydiscrepancies.
4.
5.Any areasindicatedon thissheet areapproximateandindicativeonly.
1858
Title
Scale@ArchE1
Foster Partners 2010
ReasonForIssueDate
Apple Campus 2
www.arup.comTel(415)9579445 Fax(415)9579096SanFrancisco, CA 94105 USA560MissionStreet, Suite700
ArupNorth AmericaLtd.
Apple Inc.
N
www.altaplanning.com25609thStreet, Suite212
Berkeley, CA94710p:510.540.5008 f:510.540.5039
Architects Engineers ParkingPlannerswatrydesign.com
SanJose, CaliforniaNewport Beach, California
Austin, Texas
00
00 08/26/13 PlannedDevelopment Permit
08/26/2013
S T I M E
Alldimensionsshallbe verifiedonsite beforeproceedingwiththe work.Foster Partnersshallbe notifiedinwriting of anyd
Donot scale drawings. Dimensionsgovern.1.2.3.
4.
GeneralNotes
Alldimensionsare infeet and inchesunlessnoted otherwise.
-
8/12/2019 Planos Apple 2 2
21/33
HOMESTEAD ROAD
MATCHLINE, SEE P-7.31
LEGEND
Client
Project
KeyPlan
Rev. Chk
D G N S P E C
Project No. Date
Number Revision
discrepancies.
5.Any areasindicatedon thissheet areapproximateandindicativeonly.
1858
Title
Scale@ArchE1
Foster Partners 2010
ReasonForIssueDate
Apple Campus 2
www.arup.comTel(415)9579445 Fax(415)9579096SanFrancisco, CA 94105 USA560MissionStreet, Suite700
ArupNorth AmericaLtd.
Apple Inc.
N
www.altaplanning.com
25609thStreet, Suite212Berkeley, CA94710
p:510.540.5008 f:510.540.5039
Architects Engineers ParkingPlannerswatrydesign.com
SanJose, CaliforniaNewport Beach, California
Austin, Texas
P-7.30
Material Plan - North
1"=100'
Materials Plan - North03 1' = 100'-0"
Fire Access Road Section, Typ.1/4'' = 1'-0"01
02 01/17/12 PlanningRevision
07
Perimeter Edge Condition, Typ.1/8'' = 1'-0"02
03 02/29/12 PlanningRevision
04 05/25/12 PlanningRevision
05 11/01/12 PlanningRevision
06 04/12/13 PlanningRevision
08/19/2011
00 08/19/11 PlannedDevelopment Permit
07 08/26/13 PlanningRevision
MATCHLINE, SEE P-7.30 S T I M E
Alldimensionsshallbe verifiedonsite beforeproceedingwiththe work.Foster Partnersshallbe notifiedinwriting of anydiscrepancies.
Donot scale drawings. Dimensionsgovern.1.2.3.
4.
GeneralNotes
Alldimensionsare infeet and inchesunlessnoted otherwise.
-
8/12/2019 Planos Apple 2 2
22/33
I N T E R S T A T E - 2 8 0
C A L A B A
Z A S C R
E E K
C A L A B A
Z A S C R
E E K
C O R R I
D O R
T A N T A U A V E N U E
LEGEND
Client
Project
KeyPlan
Rev. Chk
D G N S P E C
Project No. Date
Number Revision
p
5.Any areasindicatedon thissheet areapproximateandindicativeonly.
1858
Title
Scale@ArchE1
Foster Partners 2010
ReasonForIssueDate
Apple Campus 2
www.arup.comTel(415)9579445 Fax(415)9579096SanFrancisco, CA 94105 USA560MissionStreet, Suite700
ArupNorth AmericaLtd.
Apple Inc.
N
www.altaplanning.com
25609thStreet, Suite212Berkeley, CA94710
p:510.540.5008 f:510.540.5039
Architects Engineers ParkingPlannerswatrydesign.com
SanJose, CaliforniaNewport Beach, California
Austin, Texas
P-7.31
Material Plan - South
1"=100'
Materials Plan - South01 1" = 100'
02 01/17/12 PlanningRevision
07
03 02/29/12 PlanningRevision
04 05/25/12 PlanningRevision
05 11/01/12 PlanningRevision
06 04/12/13 PlanningRevision
07 08/26/13 PlanningRevision
00 08/19/11 PlannedDevelopment Permit
08/19/2011
S T I M E
Alldimensionsshallbe verifiedonsite beforeproceedingwiththe work.Foster Partnersshallbe notifiedinwriting of anydiscrepancies.
Donot scale drawings. Dimensionsgovern.1.2.3.
4.
GeneralNotes
Alldimensionsare infeet and inchesunlessnoted otherwise.
-
8/12/2019 Planos Apple 2 2
23/33
P-7.32
Exterior Materials
NTS
Typical Concrete SidewalkNTS01
Client
Project
KeyPlan
Rev. Chk
D G N S P E C
Project No. Date
Number Revision
5.Any areasindicatedon thissheet areapproximateandindicativeonly.
1858
Title
Scale@ArchE1
Foster Partners 2010
ReasonForIssueDate
Apple Campus 2
www.arup.comTel(415)9579445 Fax(415)9579096SanFrancisco, CA 94105 USA560MissionStreet, Suite700
ArupNorth AmericaLtd.
Apple Inc.
N
www.altaplanning.com
25609thStreet, Suite212Berkeley, CA94710
p:510.540.5008 f:510.540.5039
Architects Engineers ParkingPlannerswatrydesign.com
SanJose, CaliforniaNewport Beach, California
Austin, Texas
00
Stabilized Aggregate PavingNTS02 Jogging Path - Synthetic Resilient PavingNTS03 Stone Paving - South Bay uartziteNTS04
00 08/26/13 PlannedDevelopment Permit
08/26/2013
S T I M E
C
Alldimensionsshallbe verifiedonsite beforeproceedingwiththe work.Foster Partnersshallbe notifiedinwriting of anydiscrepancies.
Donot scale drawings. Dimensionsgovern.1.2.3.
4.
GeneralNotes
5.Any areasindicatedon thissheet areapproximateand
Alldimensionsare infeet and inchesunlessnoted otherwise.
-
8/12/2019 Planos Apple 2 2
24/33
P-7.33
Site Furnishings
NTS
Bench - Fermob Louisiane BenchNTS01
Client
Project
KeyPlan
Rev. Chk
D G N S P E C
Project No. Date
Number Revision
5.Any areasindicatedon thissheet areapproximateandindicativeonly.
1858
Title
Scale@ArchE1
Foster Partners 2010
ReasonForIssueDate
Apple Campus 2
www.arup.comTel(415)9579445 Fax(415)9579096SanFrancisco, CA 94105 USA560MissionStreet, Suite700
ArupNorth AmericaLtd.
Apple Inc.
N
www.altaplanning.com
25609thStreet, Suite212Berkeley, CA94710
p:510.540.5008 f:510.540.5039
Architects Engineers ParkingPlannerswatrydesign.com
SanJose, CaliforniaNewport Beach, California
Austin, Texas
00
Chairs - Fermob Luxembourg SeriesNTS02
Tables - Fermbob MiscellaneousNTS03
00 08/26/13 PlannedDevelopment Permit
08/26/2013
S T I M E
E C
Alldimensionsshallbe verifiedonsite beforeproceedingwiththe work.Foster Partnersshallbe notifiedinwriting of anydiscrepancies.
Donot scale drawings. Dimensionsgovern.1.2.3.
4.
GeneralNotes
5.Any areasindicatedon thissheet areapproximateandindicativeonly
Alldimensionsare infeet and inchesunlessnoted otherwise.
-
8/12/2019 Planos Apple 2 2
25/33
P-7.34
Site Fence Imagery
NTS
Site Fence, TypicalNTS01
Client
Project
KeyPlan
Rev. Chk
D G N S P E
Project No. Date
Number Revision
indicativeonly.
1858
Title
Scale@ArchE1
Foster Partners 2010
ReasonForIssueDate
Apple Campus 2
www.arup.comTel(415)9579445 Fax(415)9579096SanFrancisco, CA 94105 USA560MissionStreet, Suite700
ArupNorth AmericaLtd.
Apple Inc.
N
www.altaplanning.com
25609thStreet, Suite212Berkeley, CA94710
p:510.540.5008 f:510.540.5039
Architects Engineers ParkingPlannerswatrydesign.com
SanJose, CaliforniaNewport Beach, California
Austin, Texas
00
00 08/26/13 PlannedDevelopment Permit
08/26/2013
S T I M E
P E C
Alldimensionsshallbe verifiedonsite beforeproceedingwiththe work.Foster Partnersshallbe notifiedinwriting of anydiscrepancies.
Donot scale drawings. Dimensionsgovern.1.2.3.
4.
GeneralNotes
5.Any areasindicatedon thissheet areapproximateandindicativeonly.
Alldimensionsare infeet and inchesunlessnoted otherwise.
-
8/12/2019 Planos Apple 2 2
26/33
I N T E R S T A T E - 2 8 0
C A L A
B A Z A S
C R E E K
C A L A B A
Z A S C R
E E K
C O R R I
D O R
T A N T A U A V E N U E
P-7.35
Soundwall
NTSSoundwall, Alt 1NTS02
Client
Project
KeyPlan
Rev. Chk
D G N S P
Project No. Date
Number Revision
1858
Title
Scale@ArchE1
Foster Partners 2010
ReasonForIssueDate
Apple Campus 2
www.arup.comTel(415)9579445 Fax(415)9579096SanFrancisco, CA 94105 USA560MissionStreet, Suite700
ArupNorth AmericaLtd.
Apple Inc.
N
www.altaplanning.com
25609thStreet, Suite212Berkeley, CA94710
p:510.540.5008 f:510.540.5039
Architects Engineers ParkingPlannerswatrydesign.com
SanJose, CaliforniaNewport Beach, California
Austin, Texas
00
00 08/26/13 PlannedDevelopment Permit
Soundwall, Alt 2NTS03
Soundwall, Plan Layout1"=100'01
08/26/2013
-
8/12/2019 Planos Apple 2 2
27/33
LightingOutline Luminaire Schedule
E1 Output: 2500 lmBespoke Pedestrian Pole Luminaire- 13-4 Watts: 50 WBespoke exterior pole and LED luminaire as single integrated unit with. 13-4 overall height.Full cut-off Type II distribution.
Voltage: 277V AC
E2 Output: 5000 lmBespoke Mid-height Pole Luminaire - 20-0 Watts: 100 WBespoke exterior pole and LED luminaire as single integrated unit with. 20-0 overall height.Full cut-off Type II distribution.
Voltage: 277V AC
E3 Output: 6200 lmBespoke Roadway Pole Luminaire - 30-0 Watts: 150 WBespoke exterior pole and LED luminaire as single integrated unit with. 30-0 overall height.Full cut-off Type II distribution.
Voltage: 480V AC
E4 Output: 750 lmBespoke Pathway Light - 21 Watts: 15WLow-level LED pathway luminaire with full cut-off, wide light distribution. Custom m odificationto luminaire housing, final design to be coordinated.
Voltage: 277V AC
E5 Output: 750 lmLow Level Pathway Light - 39 Watts: 15WLow-level LED pathway luminaire with full cut-off, wide light distribution. Custom m odificationto luminaire housing, final design to be coordinated.
Voltage: 277V AC
E6 Output: 500 lmLow-level Adjustable Floodlight Watts: 20 WLow-level brushed aluminum floodlight, custom modified for LED source, with wide beam forsoft glaze of light on trees.
Voltage: 277V AC
E7 Output: 285 lm/ftGabion Wall Linear Uplight Watts: 6.4 W/ftLow profile linear LED with bespoke stem mounting and adjustable aiming to softly uplight thegabion wall.
Voltage: 277V AC
E8 Output: 1800 lmWall Recessed Roadway Light Watts: 20 WCircular wall recessed LED luminaire, with internal louvers to shield from glare and illuminatedriving surface.
Voltage: 277V AC
E9 Output: 100 lmLuminous Pendant in Trees Watts: 1.5 WSmall , l uminous LED pendan t suspended in tr ees to p rov ide sof t ambien t l igh t . Volt age: 277V AC
E10 Output: 137 lm/ftLinear Light Source at Benches Watts: 3.0 W/ftLinear LED source concealed beneath benches around the pond in the courtyard. The linearlights cast a soft glow to reflect in the water, but can be increased in output for egress lightlevels only when needed.
Voltage: 277V AC
E11 Output: 285 lm/ftIn-Grade Luminous Line of Light Watts: 6.4 W/ftLinear in-grade LED source to create soft uplight glow on curving walls at the Visitor EntryPlaza.
Voltage: 277V AC
E12 Output: 2315 lm/ftTunnel Lights Watts: 24 w/ftRegressed Linear LED luminaires with custom optic to illuminate the Tunnel driving surfaces. Voltage: 277V AC
-
8/12/2019 Planos Apple 2 2
28/33
LightingOutline Luminaire Schedule
E1 Output: 2500 lmBespoke Pedestrian Pole Luminaire- 13-4 Watts: 50 WBespoke exterior pole and LED luminaire as single integrated unit with. 13-4 overall height.Full cut-off Type II distribution.
Voltage: 277V AC
E2 Output: 5000 lmBespoke Mid-height Pole Luminaire - 20-0 Watts: 100 WBespoke exterior pole and LED luminaire as single integrated unit with. 20-0 overall height.Full cut-off Type II distribution.
Voltage: 277V AC
E3 Output: 6200 lmBespoke Roadway Pole Luminaire - 30-0 Watts: 150 WBespoke exterior pole and LED luminaire as single integrated unit with. 30-0 overall height.Full cut-off Type II distribution.
Voltage: 480V AC
E4 Output: 750 lmBespoke Pathway Light - 21 Watts: 15WLow-level LED pathway luminaire with full cut-off, wide light distribution. Cu stom modificationto luminaire housing, final design to be coordinated.
Voltage: 277V AC
E5 Output: 750 lmLow Level Pathway Light - 39 Watts: 15WLow-level LED pathway luminaire with full cut-off, wide light distribution. Cu stom modificationto luminaire housing, final design to be coordinated.
Voltage: 277V AC
E6 Output: 500 lmLow-level Adjustable Floodlight Watts: 20 WLow-level brushed aluminum floodlight, custom modified for LED source, with wide beam forsoft glaze of light on trees.
Voltage: 277V AC
E7 Output: 285 lm/ftGabion Wall Linear Uplight Watts: 6.4 W/ftLow profile linear LED with bespoke stem mounting and adjustable aiming to softly uplight thegabion wall.
Voltage: 277V AC
E8 Output: 1800 lmWall Recessed Roadway Light Watts: 20 WCircular wall recessed LED luminaire, with internal louvers to shield from glare and illuminatedriving surface.
Voltage: 277V AC
E9 Output: 100 lmLuminous Pendant in Trees Watts: 1.5 WSmall , l uminous LED pendan t suspended in tr ees to p rov ide sof t ambien t l igh t . Volt age : 277V AC
E10 Output: 137 lm/ftLinear Light Source at Benches Watts: 3.0 W/ftLinear LED source concealed beneath benches around the pond in the courtyard . The linearlights cast a soft glow to reflect in the water, but can be increased in output for egress lightlevels only when needed.
Voltage: 277V AC
E11 Output: 285 lm/ftIn-Grade Luminous Line of Light Watts: 6.4 W/ftLinear in-grade LED source to create soft uplight glow on curving walls at the Visitor EntryPlaza.
Voltage: 277V AC
E12 Output: 2315 lm/ftTunnel Lights Watts: 24 w/ftRegressed Linear LED luminaires with custom optic to illuminate the Tunnel driving surfaces. Voltage: 277V AC
-
8/12/2019 Planos Apple 2 2
29/33
LightingOutline Luminaire Schedule
E1 Output: 2500 lmBespoke Pedestrian Pole Luminaire- 13-4 Watts: 50 WBespoke exterior pole and LED luminaire as single integrated unit with. 13-4 overall height.Full cut-off Type II distribution.
Voltage: 277V AC
E2 Output: 5000 lmBespoke Mid-height Pole Luminaire - 20-0 Watts: 100 WBespoke exterior pole and LED luminaire as single integrated unit with. 20-0 overall height.Full cut-off Type II distribution.
Voltage: 277V AC
E3 Output: 6200 lmBespoke Roadway Pole Luminaire - 30-0 Watts: 150 WBespoke exterior pole and LED luminaire as single integrated unit with. 30-0 overall height.Full cut-off Type II distribution.
Voltage: 480V AC
E4 Output: 750 lmBespoke Pathway Light - 21 Watts: 15WLow-level LED pathway luminaire with full cut-off, wide light distribution. Custom m odificationto luminaire housing, final design to be coordinated.
Voltage: 277V AC
E5 Output: 750 lmLow Level Pathway Light - 39 Watts: 15WLow-level LED pathway luminaire with full cut-off, wide light distribution. Custom m odificationto luminaire housing, final design to be coordinated.
Voltage: 277V AC
E6 Output: 500 lmLow-level Adjustable Floodlight Watts: 20 WLow-level brushed aluminum floodlight, custom modified for LED source, with wide beam forsoft glaze of light on trees.
Voltage: 277V AC
E7 Output: 285 lm/ftGabion Wall Linear Uplight Watts: 6.4 W/ftLow profile linear LED with bespoke stem mounting and adjustable aiming to softly uplight thegabion wall.
Voltage: 277V AC
E8 Output: 1800 lmWall Recessed Roadway Light Watts: 20 WCircular wall recessed LED luminaire, with internal louvers to shield from glare and illuminatedriving surface.
Voltage: 277V AC
E9 Output: 100 lmLuminous Pendant in Trees Watts: 1.5 WSmall , l uminous LED pendan t suspended in tr ees to p rov ide sof t ambien t l igh t . Volt age: 277V AC
E10 Output: 137 lm/ftLinear Light Source at Benches Watts: 3.0 W/ftLinear LED source concealed beneath benches around the pond in the courtyard. The linearlights cast a soft glow to reflect in the water, but can be increased in output for egress lightlevels only when needed.
Voltage: 277V AC
E11 Output: 285 lm/ftIn-Grade Luminous Line of Light Watts: 6.4 W/ftLinear in-grade LED source to create soft uplight glow on curving walls at the Visitor EntryPlaza.
Voltage: 277V AC
E12 Output: 2315 lm/ftTunnel Lights Watts: 24 w/ftRegressed Linear LED luminaires with custom optic to illuminate the Tunnel driving surfaces. Voltage: 277V AC
-
8/12/2019 Planos Apple 2 2
30/33
LightingOutline Luminaire Schedule
E1 Output: 2500 lmBespoke Pedestrian Pole Luminaire- 13-4 Watts: 50 WBespoke exterior pole and LED luminaire as single integrated unit with. 13-4 overall height.Full cut-off Type II distribution.
Voltage: 277V AC
E2 Output: 5000 lmBespoke Mid-height Pole Luminaire - 20-0 Watts: 100 WBespoke exterior pole and LED luminaire as single integrated unit with. 20-0 overall height.Full cut-off Type II distribution.
Voltage: 277V AC
E3 Output: 6200 lmBespoke Roadway Pole Luminaire - 30-0 Watts: 150 WBespoke exterior pole and LED luminaire as single integrated unit with. 30-0 overall height.Full cut-off Type II distribution.
Voltage: 480V AC
E4 Output: 750 lmBespoke Pathway Light - 21 Watts: 15WLow-level LED pathway luminaire with full cut-off, wide light distribution. Cu stom modificationto luminaire housing, final design to be coordinated.
Voltage: 277V AC
E5 Output: 750 lmLow Level Pathway Light - 39 Watts: 15WLow-level LED pathway luminaire with full cut-off, wide light distribution. Cu stom modificationto luminaire housing, final design to be coordinated.
Voltage: 277V AC
E6 Output: 500 lmLow-level Adjustable Floodlight Watts: 20 WLow-level brushed aluminum floodlight, custom modified for LED source, with wide beam forsoft glaze of light on trees.
Voltage: 277V AC
E7 Output: 285 lm/ftGabion Wall Linear Uplight Watts: 6.4 W/ftLow profile linear LED with bespoke stem mounting and adjustable aiming to softly uplight thegabion wall.
Voltage: 277V AC
E8 Output: 1800 lmWall Recessed Roadway Light Watts: 20 WCircular wall recessed LED luminaire, with internal louvers to shield from glare and illuminatedriving surface.
Voltage: 277V AC
E9 Output: 100 lmLuminous Pendant in Trees Watts: 1.5 WSmall , l uminous LED pendan t suspended in tr ees to p rov ide sof t ambien t l igh t . Volt age : 277V AC
E10 Output: 137 lm/ftLinear Light Source at Benches Watts: 3.0 W/ftLinear LED source concealed beneath benches around the pond in the courtyard . The linearlights cast a soft glow to reflect in the water, but can be increased in output for egress lightlevels only when needed.
Voltage: 277V AC
E11 Output: 285 lm/ftIn-Grade Luminous Line of Light Watts: 6.4 W/ftLinear in-grade LED source to create soft uplight glow on curving walls at the Visitor EntryPlaza.
Voltage: 277V AC
E12 Output: 2315 lm/ftTunnel Lights Watts: 24 w/ftRegressed Linear LED luminaires with custom optic to illuminate the Tunnel driving surfaces. Voltage: 277V AC
-
8/12/2019 Planos Apple 2 2
31/33
LightingOutline Luminaire Schedule
E1 Output: 2500 lmBespoke Pedestrian Pole Luminaire- 13-4 Watts: 50 WBespoke exterior pole and LED luminaire as single integrated unit with. 13-4 overall height.Full cut-off Type II distribution.
Voltage: 277V AC
E2 Output: 5000 lmBespoke Mid-height Pole Luminaire - 20-0 Watts: 100 WBespoke exterior pole and LED luminaire as single integrated unit with. 20-0 overall height.Full cut-off Type II distribution.
Voltage: 277V AC
E3 Output: 6200 lmBespoke Roadway Pole Luminaire - 30-0 Watts: 150 WBespoke exterior pole and LED luminaire as single integrated unit with. 30-0 overall height.Full cut-off Type II distribution.
Voltage: 480V AC
E4 Output: 750 lmBespoke Pathway Light - 21 Watts: 15WLow-level LED pathway luminaire with full cut-off, wide light distribution. Custom m odificationto luminaire housing, final design to be coordinated.
Voltage: 277V AC
E5 Output: 750 lmLow Level Pathway Light - 39 Watts: 15WLow-level LED pathway luminaire with full cut-off, wide light distribution. Custom m odificationto luminaire housing, final design to be coordinated.
Voltage: 277V AC
E6 Output: 500 lmLow-level Adjustable Floodlight Watts: 20 WLow-level brushed aluminum floodlight, custom modified for LED source, with wide beam forsoft glaze of light on trees.
Voltage: 277V AC
E7 Output: 285 lm/ftGabion Wall Linear Uplight Watts: 6.4 W/ftLow profile linear LED with bespoke stem mounting and adjustable aiming to softly uplight thegabion wall.
Voltage: 277V AC
E8 Output: 1800 lmWall Recessed Roadway Light Watts: 20 WCircular wall recessed LED luminaire, with internal louvers to shield from glare and illuminatedriving surface.
Voltage: 277V AC
E9 Output: 100 lmLuminous Pendant in Trees Watts: 1.5 WSmall , l uminous LED pendan t suspended in tr ees to p rov ide sof t ambien t l igh t . Volt age: 277V AC
E10 Output: 137 lm/ftLinear Light Source at Benches Watts: 3.0 W/ftLinear LED source concealed beneath benches around the pond in the courtyard. The linearlights cast a soft glow to reflect in the water, but can be increased in output for egress lightlevels only when needed.
Voltage: 277V AC
E11 Output: 285 lm/ftIn-Grade Luminous Line of Light Watts: 6.4 W/ftLinear in-grade LED source to create soft uplight glow on curving walls at the Visitor EntryPlaza.
Voltage: 277V AC
E12 Output: 2315 lm/ftTunnel Lights Watts: 24 w/ftRegressed Linear LED luminaires with custom optic to illuminate the Tunnel driving surfaces. Voltage: 277V AC
-
8/12/2019 Planos Apple 2 2
32/33
LightingOutline Luminaire Schedule
E1 Output: 2500 lmBespoke Pedestrian Pole Luminaire- 13-4 Watts: 50 WBespoke exterior pole and LED luminaire as single integrated unit with. 13-4 overall height.Full cut-off Type II distribution.
Voltage: 277V AC
E2 Output: 5000 lmBespoke Mid-height Pole Luminaire - 20-0 Watts: 100 WBespoke exterior pole and LED luminaire as single integrated unit with. 20-0 overall height.Full cut-off Type II distribution.
Voltage: 277V AC
E3 Output: 6200 lmBespoke Roadway Pole Luminaire - 30-0 Watts: 150 WBespoke exterior pole and LED luminaire as single integrated unit with. 30-0 overall height.Full cut-off Type II distribution.
Voltage: 480V AC
E4 Output: 750 lmBespoke Pathway Light - 21 Watts: 15WLow-level LED pathway luminaire with full cut-off, wide light distribution. Cu stom modificationto luminaire housing, final design to be coordinated.
Voltage: 277V AC
E5 Output: 750 lmLow Level Pathway Light - 39 Watts: 15WLow-level LED pathway luminaire with full cut-off, wide light distribution. Cu stom modificationto luminaire housing, final design to be coordinated.
Voltage: 277V AC
E6 Output: 500 lmLow-level Adjustable Floodlight Watts: 20 WLow-level brushed aluminum floodlight, custom modified for LED source, with wide beam forsoft glaze of light on trees.
Voltage: 277V AC
E7 Output: 285 lm/ftGabion Wall Linear Uplight Watts: 6.4 W/ftLow profile linear LED with bespoke stem mounting and adjustable aiming to softly uplight thegabion wall.
Voltage: 277V AC
E8 Output: 1800 lmWall Recessed Roadway Light Watts: 20 W
Circular wall recessed LED luminaire, with internal louvers to shield from glare and illuminatedriving surface. Voltage: 277V AC
E9 Output: 100 lmLuminous Pendant in Trees Watts: 1.5 WSmall , l uminous LED pendan t suspended in tr ees to p rov ide sof t ambien t l igh t . Volt age : 277V AC
E10 Output: 137 lm/ftLinear Light Source at Benches Watts: 3.0 W/ftLinear LED source concealed beneath benches around the pond in the courtyard . The linearlights cast a soft glow to reflect in the water, but can be increased in output for egress lightlevels only when needed.
Voltage: 277V AC
E11 Output: 285 lm/ftIn-Grade Luminous Line of Light Watts: 6.4 W/ftLinear in-grade LED source to create soft uplight glow on curving walls at the Visitor EntryPlaza.
Voltage: 277V AC
E12 Output: 2315 lm/ftTunnel Lights Watts: 24 w/ftRegressed Linear LED luminaires with custom optic to illuminate the Tunnel driving surfaces. Voltage: 277V AC
-
8/12/2019 Planos Apple 2 2
33/33
LightingOutline Luminaire Schedule
E1 Output: 2500 lmBespoke Pedestrian Pole Luminaire- 13-4 Watts: 50 WBespoke exterior pole and LED luminaire as single integrated unit with. 13-4 overall height.Full cut-off Type II distribution.
Voltage: 277V AC
E2 Output: 5000 lmBespoke Mid-height Pole Luminaire - 20-0 Watts: 100 WBespoke exterior pole and LED luminaire as single integrated unit with. 20-0 overall height.Full cut-off Type II distribution.
Voltage: 277V AC
E3 Output: 6200 lmBespoke Roadway Pole Luminaire - 30-0 Watts: 150 WBespoke exterior pole and LED luminaire as single integrated unit with. 30-0 overall height.Full cut-off Type II distribution.
Voltage: 480V AC
E4 Output: 750 lmBespoke Pathway Light - 21 Watts: 15WLow-level LED pathway luminaire with full cut-off, wide light distribution. Cu stom modificationto luminaire housing, final design to be coordinated.
Voltage: 277V AC
E5 Output: 750 lmLow Level Pathway Light - 39 Watts: 15WLow-level LED pathway luminaire with full cut-off, wide light distribution. Cu stom modificationto luminaire housing, final design to be coordinated.
Voltage: 277V AC
E6 Output: 500 lmLow-level Adjustable Floodlight Watts: 20 WLow-level brushed aluminum floodlight, custom modified for LED source, with wide beam forsoft glaze of light on trees.
Voltage: 277V AC
E7 Output: 285 lm/ftGabion Wall Linear Uplight Watts: 6.4 W/ftLow profile linear LED with bespoke stem mounting and adjustable aiming to softly uplight thegabion wall.
Voltage: 277V AC
E8 Output: 1800 lmWall Recessed Roadway Light Watts: 20 W
Circular wall recessed LED luminaire, with internal louvers to shield from glare and illuminatedriving surface. Voltage: 277V AC
E9 Output: 100 lmLuminous Pendant in Trees Watts: 1.5 WSmall , l uminous LED pendan t suspended in tr ees to p rov ide sof t ambien t l igh t . Volt age : 277V AC
E10 Output: 137 lm/ftLinear Light Source at Benches Watts: 3.0 W/ftLinear LED source concealed beneath benches around the pond in the courtyard . The linearlights cast a soft glow to reflect in the water, but can be increased in output for egress lightlevels only when needed.
Voltage: 277V AC
E11 Output: 285 lm/ftIn-Grade Luminous Line of Light Watts: 6.4 W/ftLinear in-grade LED source to create soft uplight glow on curving walls at the Visitor EntryPlaza.
Voltage: 277V AC
E12 Output: 2315 lm/ftTunnel Lights Watts: 24 w/ftRegressed Linear LED luminaires with custom optic to illuminate the Tunnel driving surfaces. Voltage: 277V AC