19 wcdma controle de potencia

57
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved www.huawei.com Internal OWJ200107 WCDMA Controle de Potência ISSUE 1.1 PDF created with pdfFactory Pro trial version www.pdffactory.com

Upload: emerson-eduardo-rodrigues-pmp

Post on 25-Jan-2017

327 views

Category:

Engineering


2 download

TRANSCRIPT

Page 1: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

www.huawei.com

Internal

OWJ200107 WCDMA Controle de Potência

ISSUE 1.1

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 2: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 1All rights reserved

CapCapíítulo 1 Visão Geral do Controle de Potênciatulo 1 Visão Geral do Controle de Potência

CapCapíítulo 2 Controle de Potência de tulo 2 Controle de Potência de looploop abertoaberto

CapCapíítulo 3 Controle de Potência de tulo 3 Controle de Potência de looploop fechadofechado

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 3: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 2All rights reserved

l Características da transmissão Uplink

[ Interferência mutua

[ Capacidade limitada pela interferência

[ Efeito Near-far

[ Desvanecimento

l Controle de potencia Uplink

[ Assegurar a qualidade de uplink com mínima transmissão de potencia

[ Diminuir a interferência para outra UE, e incrementar a capacidade

[ Solucionar o efeito Near-far

[ Economizar energia do UE

Finalidade do Controle de potência de uplink

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 4: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 3All rights reserved

l Características da transmissão downlink

[ Interferência entre diferentes assinantes com ortogonalidade prejudicada pelo meio de propagação.

[ Interferência proveniente de outras células adjacentes

[ Capacidade de dowlink é limitada pela potencia de transmissão do NodeB

[ Desvanecimento

l Controle de potencia Downlink

[ Assegurar a qualidade de potencia downlink com mínima transmissão de potencia

[ Diminuir a interferência entre UE, e incrementar a capacidade

[ Economizar energia do NodeB

Finalidade do Controle de potência de downlink

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 5: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 4All rights reserved

A relação entre a potencia de transmitida e a potência recebida depois de introduzido métodos de controle de potência

0 200 400 600 800-20

-15

-10

-5

0

5

10

15

20

Time (ms)

Rel

ativ

e po

wer

(dB

)

ChannelTransmitted power

Received power

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 6: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 5All rights reserved

Classificação do controle de potência

l Classificação do controle de potência:

[ Controle de potência de loop aberto

[ Controle de potência de loop fechado

− Uplink inner power control

− Downlink inner-power control

− Uplink outer power control

− Downlink outer power control

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 7: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 6All rights reserved

Métodos de controle de potência adotado para vários canais físicosl Métodos de controle de potência adotado para vários canais físicos

l "X" – pode ser selecionado, "–" – não pode ser selecionado

X---PICH

X---AICH

---XPRACH

X---SCCPCH

X---PCCPCH

-XXXDPCCH

-XX-DPDCH

No power control process, power is specified by upperlayers.

Outer looppower

Control

Inner looppowercontrol

Open looppowercontrol

Physicalchannel

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 8: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 7All rights reserved

CapCapíítulo 1 Visão Geral do Controle de Potênciatulo 1 Visão Geral do Controle de Potência

CapCapíítulo 2 Controle de Potência de tulo 2 Controle de Potência de looploop aberto aberto

CapCapíítulo 3 Controle de Potência de tulo 3 Controle de Potência de looploop fechadofechado

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 9: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 8All rights reserved

CapCapíítulo 2 Controle de Potência de tulo 2 Controle de Potência de looploop abertoaberto

2.1 Visão Geral do controle de potência de 2.1 Visão Geral do controle de potência de looploop abertoaberto

2.2 Controle de potência 2.2 Controle de potência looploop aberto de PRACHaberto de PRACH

2.3 Controle de potência 2.3 Controle de potência looploop aberto de DPCCHaberto de DPCCH

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 10: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 9All rights reserved

Visão Geral do Controle de potência de loop aberto

l Finalidade

[UE estima a perda de potência de sinais no trajeto da propagação medindo os sinais de downlink, então calcula a potência de transmissão de canal de uplink

l O principio do controle de potência de loop aberto

[Desvanecimento rápido no canal de uplink/downlink

[Desvanecimento de uplink/downlink são descorrelacionados.

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 11: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 10All rights reserved

l A desvantagem do controle de potência de loop aberto

[Este método de controle de potência é vago

l Cenários de aplicação do controle de potência de loop aberto

[Na região de uma célula onde o desvanecimento rápido é mais serio do que a perda de propagação

[Controle de potência de loop aberto é admitido somente no inicio do setup da conexão, geralmente é definido um valor inicial de potência.

Visão Geral do Controle de potência de loop aberto

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 12: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 11All rights reserved

CapCapíítulo 2 Controle de Potência de tulo 2 Controle de Potência de looploop abertoaberto

2.1 Visão Geral do controle de potência de 2.1 Visão Geral do controle de potência de looploop abertoaberto

2.2 Controle de potência de 2.2 Controle de potência de looploop aberto de PRACHaberto de PRACH

2.3 Controle de potência de 2.3 Controle de potência de looploop aberto de DPCCHaberto de DPCCH

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 13: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 12All rights reserved

Controle de potência de loop aberto no PRACH

O procedimento de acesso aleatório no PRACH é mostrado na figura acima: O UE transmite um preâmbulo usando o slot de acesso selecionado do uplink em uma determinada potencia e sua identificação. A UTARN responderá com uma mensagem de Al se o preâmbulo for recebido.

Então o UE irá transmitir a mensagem parcial se Al é recebida. Se o UE não receber o Al da UTRAN no período τp-p, um próximo preâmbulo será transmitido. O número de vezes que o UE repete o preâmbulo é determinado pelas características da rede.

AICH accessslots RX at UE

PRACH accessslots TX at UE

One access slot

τ p-a

τp-mτp-p

Pre-amble

Pre-amble

Message part

Acq.Ind.

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 14: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 13All rights reserved

Controle de potência de loop aberto no PRACH

l O valor inicial da potência PRACH é ajustado através do controle de potência de loop aberto

Preamble_Initial_Power = PCPICH DL TX power-CPICH_RSCP + UL

interference + Constant Value

l Explanação dos parâmetros

[ O valor do PCPICH DL TX power, interferência no UL e o valor constante constam nas system information (SIB)

[ O valor de CPICH_RSCP é medido pela UE

[ PCPICH DL TX power está relacionado com a área de cobertura de downlink, que já foi configurada durante o cell setup.

[ Interferência UL pode ser medida pelo NodeB, então irá reportar para o RNC.

[ Valor constante é o ponto inicial da preamble message. Este valor deve ser analisado muito cuidadosamente.

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 15: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 14All rights reserved

Este parâmetro é o máximo permitido de repetição de tempos de preamble da UE com um preamble ramp cvcle

Preamble Retrans Max 4

Este parâmetro é o ponto inicial do preamble power quando a UE não recebe a indicação de captura do NodeB

PRACH Power Ramp Step3

Este parâmetro é a constante de correção usada para a UE estimar a potência inicial de transmissão de PRACH de acordo com a potência open loop

Constant Value2

O power offset do ultimo preamble de acesso e parte de controle de mensagem. Este valor somado ao access preamble power é a potência da parte de controle.

Power Offset Pp-m 1Parameter meaningParameterNO.

Power Ramp Step

Pp-m

10ms/20ms

Preamble_Initial_power

Controle de potência de loop aberto no PRACH

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 16: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 15All rights reserved

l Valores de constantes diferente para diferentes estágios de evolução da rede WCDMA. Seja o estágio inicial como exemplo:

[ O valor constante pode ser maior que ( -16 dB ou –15dB) então a preamble message deve ser recebida facilmente pela UTRAN

[ O power ramp step deve ser melhor de modo que a possibilidade que a preamble message possa ser recebida corretamente serámaior

l Com o aumento dos assinantes, o valor constante deve ser menor que 1 dB

Controle de potência de loop aberto no PRACH

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 17: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 16All rights reserved

CenCenáários de aplicarios de aplicaççãoão

1. CCCH : RRC Connection Request

Open loop powercontrol of PRACH

5. Downlink Synchronisation

UE Node BServing RNS

Serving RNC

DCH - FP

Allocate RNTISelect L1 and L2parameters

RRCRRC

NBAPNBAP3. Radio Link Setup Response

NBAPNBAP2. Radio Link Setup Request

RRCRRC7. CCCH : RRC Connection Set up

Start RX description

Start TX description

4. ALCAP Iub Data Transport Bearer Setup

RRCRRC9. DCCH : RRC Connection Setup Complete

6. Uplink Synchronisation

NBAPNBAP8. Radio Link Restore Indication

DCH - FP

DCH - FP

DCH - FP

Controle de potência de loop aberto no PRACH

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 18: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 17All rights reserved

CapCapíítulo 2 Controle de Potência de tulo 2 Controle de Potência de looploop abertoaberto

2.1 Visão Geral do controle de potência de 2.1 Visão Geral do controle de potência de looploop abertoaberto

2.2 Controle de potência de 2.2 Controle de potência de looploop aberto de PRACHaberto de PRACH

2.3 Controle de potência de 2.3 Controle de potência de looploop aberto de DPCCHaberto de DPCCH

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 19: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 18All rights reserved

Controle de potência de loop aberto no DL DPCCH

l O controle de potência de loop aberto no DL DPDCH pode ser calculado pela formula que se segue:

P=(Ec/Io)Req-CPICH_Ec/Io+PCPICH

l Explanação dos Parâmetros

[ (Ec/lo)req é o requerido Ec/lo, que deverá satisfazer UE para poder receber a mensagem corretamente do canal dedicado

[ CPICH_Ec/lo é medido pela UE, então é entregue para a UTRAN pela RACH

[ PCPICH é a potência de transmissão do CPICH

l Comentários

[ Similar para UL, o (Ec/lo)Req valor que deverá ser considerado com muito cuidado

[ Porque não há power ramp no inicio do DL DPCCH, o inicio deve estar de acordo com as exigências. Portanto, este valor pode ser maior que o de uma simulação que garanta sucesso proporcional

[ Com PO1, PO2 e PO3, A potência de transmissão inicial para DPCCH pode ser calculada

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 20: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 19All rights reserved

CenCenáários de Aplicarios de Aplicaççãoão

1. CCCH : RRC Connection Request

Open loop powercontrol of DPCCH 5. Downlink Synchronisation

UE Node BServing RNS

ServingRNC

DCH - FP

Allocate RNTISelect L1 and L2parameters

RRCRRC

NBAPNBAP3. Radio Link Setup Response

NBAPNBAP2. Radio Link Setup Request

RRCRRC 7. CCCH : RRC Connection Set up

Start RX description

Start TX description

4. ALCAP Iub Data Transport Bearer Setup

RRCRRC9. DCCH : RRC Connection Setup Complete

6. Uplink Synchronisation

NBAPNBAP8. Radio Link Restore Indication

DCH - FP

DCH - FP

DCH - FP

Controle de potência de loop aberto no DL DPCCH

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 21: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 20All rights reserved

l O controle de potência de loop aberto no UL DPCCH pode ser calculado pela fórmula que se segue:

DPCCH_Initial_power=PCPICH DL TX power-CPICH_RSCP

+UL interference+ Default Constant Value

l Explanação das referências

[ PCPICH DL TX power é a potência de transmissão de CPICH

[ CPICH_RSCP pode ser medido pela UE

[ Interferência UL pode ser medido pelo NodeB

l Comentários

[ Default Constant Value irá decidir a potência de transmissão inicial de Uplink DPCCH

[ Este valor é diferente do precedente “Constante value” para PRACH

Controle de potência de loop aberto no DL DPCCH

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 22: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 21All rights reserved

1. CCCH : RRC Connection Request

Open loop powercontrol of DPCCH

5. Downlink Synchronisation

UE Node BServing RNS

Serving RNC

DCH - FP

Allocate RNTISelect L1 and L2parameters

RRCRRC

NBAPNBAP3. Radio Link Setup Response

NBAPNBAP2. Radio Link Setup Request

RRCRRC7. CCCH : RRC Connection Set up

Start RX description

Start TX description

4. ALCAP Iub Data Transport Bearer Setup

RRCRRC9. DCCH : RRC Connection Setup Complete

6. Uplink Synchronisation

NBAPNBAP8. Radio Link Restore Indication

DCH - FP

DCH - FP

DCH - FP

Controle de potência de loop aberto no DL DPCCHCenCenáários de Aplicarios de Aplicaççãoão

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 23: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 22All rights reserved

CapCapíítulo 1 Visão Geral do Controle de Potência tulo 1 Visão Geral do Controle de Potência

CapCapíítulo 2 Controle de Potência de tulo 2 Controle de Potência de looploop aberto aberto

CapCapíítulo 3 Controle de Potência tulo 3 Controle de Potência looploop fechado fechado

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 24: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 23All rights reserved

CapCapíítulo 3 Controle de Potência de tulo 3 Controle de Potência de looploop fechadofechado

3.1 Visão geral do Controle de Potência de 3.1 Visão geral do Controle de Potência de looploop fechado fechado

3.2 Controle de potência 3.2 Controle de potência UplinkUplink innerinner looploop

3.3 Controle de potência 3.3 Controle de potência DownlinkDownlink innerinner looploop

3.4 Controle de potência 3.4 Controle de potência OuterOuter looploop

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 25: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 24All rights reserved

Visão geral do controle de potência de loop fechado

l As deficiências do controle de potência de loop aberto

[ O valor de potência decidido pelo controle de potência de loop aberto pode ser impreciso

[ Para o sistema WCDMA-FDD, o desvanecimento de uplink édescorrelacionado do desvanecimento no downlink devido ao grande espaçamento de freqüência entre eles.

[ Portanto, a estimativa da perda de percurso e da interferência feita no downlink pode não refletir corretamente as características do uplink. O controle de potência de loop fechado pode solucionar este problema.

l Vantagens do controle de potência de loop fechado

[ Ajusta os valores de potência de uplink e downlink muito rapidamente, diminuindo a interferência no sistema.

[ Mantêm elevada a qualidade do serviço

Porque o controle de potência Porque o controle de potência éé necessnecessááriorio

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 26: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 25All rights reserved

Visão geral do controle de potência

Inner loopOuter loopControl process:BLERmea>BLERtar→SIRtar

BLERmea<BLERtar→SIRtar

Until to BLERmea=BLERtar

SIRtar

Control process:SIRmea>SIRtar→TPC=0

SIRmea<SIRtar→ TPC=1

Until toSIRmea=SIRtar

TPC

Control process:TPC=0 PowerTPC=1 Power

Controle de potência Inner loopCom TPC no DPCCH, o SIR pode ser assegurado ao nível target de SIR. Controle de pôtencia inner loop pode ser feito 1500 vezes em um segundoOuter loop power control

Com o ajuste do SIR target value, BLER pode ser assegurado à exigencia de Qos

BLERtar

Garantia de QoS com potência mínima

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 27: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 26All rights reserved

CapCapíítulo 3 Controle de Potência de tulo 3 Controle de Potência de looploop fechadofechado

3.1 Visão geral do Controle de Potência de 3.1 Visão geral do Controle de Potência de looploop fechadofechado

3.2 Controle de potência 3.2 Controle de potência UplinkUplink innerinner looploop

3.3 Controle de potência 3.3 Controle de potência DownlinkDownlink innerinner looploop

3.4 Controle de potência 3.4 Controle de potência OuterOuter looploop

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 28: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 27All rights reserved

Controle de potência uplink-inner loop

l NodeB compara a relação sinal-interferência medida com o

valor pré ajustado (SIRtarget).

NodeBUE

Transmit TPC

Inner-loop

set SIRtar

1500Hz1500Hz

Each UE hasits own loopEach UE hasits own loop

TPC Decision(0,1)

TPC_CMD(-1, 0, 1)

Adjust DPCCH Tx△DPCCH=△tpc×TPC_cmd

PCA1PCA2

Adjust DPDCH Tx(βc,βd)

Compare SIRmeas with SIRtarSIRmea>SIRtar→TPC=0SIRmea<SIRtar→ TPC=1

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 29: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 28All rights reserved

l Os receptores calculam a SIR estimando a intensidade do sinal e da interferência atual. Este valor de SIR é então comparado com SIRtarget.

[ Se menor que SIRtarget, o TPC é 1 para indicar aos receptores aumento da potência de transmissão

[ Se maior que SIRtarget, o TPC é 0 para indicar aos receptores diminuição da potência de transmissão

l O controle de potencia inner loop provê a convergência da SIR estimada para SIR target

GeraGeraçção do TPCão do TPC

Controle de potência uplink-inner loop

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 30: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 29All rights reserved

l No protocolo 3GPP, o UE pode receber diferentes TPC_cmd(1,0,-1) de acordo com o PCA (power control algorithm) empregado.

l Ajuste no DPCCH

△DPCCH=△tpc× TPC_cmd− If TPC_cmd=1,Uplink DPCCH Tx should increase△tpc

− If TPC_cmd=-1,Uplink DPCCH Tx should decrease△tpc

− If TPC_cmd=0,uplink DPCCH Tx does not change

l △tpc

[ PCA1,uplink power control step is △tpc=1dB ou 2dB

[ PCA2, uplink power control step is △tpc=1dB

TPC_cmdTPC_cmd

Controle de potência uplink-inner loop

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 31: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 30All rights reserved

l Potência de uplink DPDCH é decidido pelo offset junto com DPCCH e DPDCH

l Este offset é decidido pela camada mais acima

PilotN pilot bits

TPCNTPCbits

DataNdata bits

Slot #0 Slot #1 Slot #i Slot #14

Tslot= 2560 chips, 10 bits

1 radio frame: T f = 10 ms

DPDCH

DPCCHFBI

N FBI bitsTFCI

N TFCI bits

Tslot= 2560 chips, N data= 10*2 kbits (k=0..6)

Controle de potência uplink-inner loop

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 32: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 31All rights reserved

l UE recebe um TPC em cada time slot

[ If TPC=0, TPC_cmd= -1

[ If TPC=1, TPC_cmd= 1

Este controle é feito em cada TS

A freqüência do controle de potencia é 1500HZ

0110110110…… ……

…… ……TPC_CMD

TPC

-111-111-111-1

Sem Sem softsoft handoverhandover no PCA1no PCA1

Controle de potência uplink-inner loop

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 33: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 32All rights reserved

0110110110…… ……

RLS1-TPC (W1)

…… ……RLS2-TPC (W2) 1010101101

…… ……

…… ……TPC_CMD

1101100100

0000100100

Each TS, combine TPC from different RLS,then get Wi

CELL1 CELL2

CELL4CELL3

RL11 RL12RLS1

RLS2 RLS3

RLS3-TPC (W3)

Get TPC_cmd based onTPC_cmd = γ (W1, W2, … WN)

Controle de potência uplink-inner loop

Com Com softsoft handoverhandover PCA 1PCA 1

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 34: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 33All rights reserved

l Em cada time slot o UE receberá TPC’s de diferentes RL. O UE determinará o TPC_cmd resultante baseado nos seguintes steps:

[ Combinar TPC’s do mesmo RLS. Atualmente, os TPCs do mesmo RLS são iguais;

[ Combinar TPC’s de diferentes RLS. Supondo que o TPC para RLSi é Wi tem-se:

− TPC=0, Wi =0

− TPC=1, Wi =1

l TPC_cmd = γ (W1, W2, … Wn)

[ Se qualquer um dos Wi for igual a 0 então, TPC_cmd=-1

[ Se todos os Wi forem iguais a 1 então, TPC_cmd=1

Controle de potência uplink-inner loop

Com Com softsoft handoverhandover PCA 1PCA 1

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 35: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 34All rights reserved

110111111100000

TS14TS13TS12TS11TS10TS9TS8TS7TS6TS5TS4TS3TS2TS1TS0

10ms/frame

Grupo 2Grupo 1 Grupo 3

…… ……

-1000010000-10000

TPC

TPC_CMD

Transmissão de potencia irá ser controlada em cada 5 time slotsA freqüência é 300HZ

…… ……

Controle de potência uplink-inner loop

Sem Sem softsoft handoverhandover no PCA2no PCA2

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 36: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 35All rights reserved

l Somente um TPC é recebido em cada time slot. O controle de potência pode ser feito uma vez a cada 5 time slot. Cada frame é dividido em 3 grupos com 5 time slots. Nos primeiros 4 time slots, o TPC_cmds serão 0, o que significa que a potencia não muda. No 5º time slot, o TPC_cmd pode ser determinado pelas seguintes regras:

[ Se todos os TPC forem 0, o TPC_cmd é –1 e a potência de transmissão diminuirá 1 dB

[ Se todos os TPC forem 1, o TPC_cmd é –1 e a potência de transmissão aumentará 1 dB

[ Caso contrario, TPC_cmd=0.

0000 0Se não

0000 11111 1

0000 -10000 0

TPC_cmdTPC (RX)

Controle de potência Uplink-inner loopSem Sem softsoft handoverhandover no PCA2no PCA2

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 37: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 36All rights reserved

Combinar TPC de um mesmo RLS em cada time slot

Calculo TPC_cmd

TPC_CMD=1

TPC_CMD=-1

Caso contrário TPC_CMD=0

Calculo TPC_tempi par cada RLSvIf 5 TPC are all 1, TPC_tempi=1vIf 5 TPC are all 0, TPC_tempi=-1vOtherwise, TPC_tempi =0

5.0_11

>∑=

N

iitempTPC

N

5.0_11

−<∑=

N

iitempTPC

N

CELL1 CELL2

CELL4CELL3

RL11 RL12RLS1

RLS2 RLS3

Controle de potência uplink-inner loop

Com Com softsoft handoverhandover no PCA2no PCA2

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 38: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 37All rights reserved

l Quando a UE está em soft handover, o TPC_cmd pode ser obtido através dos seguintes passos

[ Combinação do TPC de um mesmo RLS

− N TPCi (i = 1,2......N) pode ser obtido do RLSes N em cada time slot

− Os N TPC_cmds de diferentes RLS podem ser obtidos pela regra mencionada acima. O TPC_cmd é 0 nos primeiros 4 time slots. O comando final de TPC_cmd é decidido no quinto time slot

− Cada TPC_cmd final referente ao RLS N é definido como TPC_tempi(i = 1,2......N)

− TPC_tempi=0 nos primeiros 4 time slots

− O TPC_cmd no quinto time slot é obtido pela seguinte regra:

▪ Média dos N TPC_tempi’s. Se maior que 0.5 então TPC_cmd=1. Se menor que -0.5 então TPC_cmd=-1, caso contrario TPC_cmd=0

Com Com softsoft handoverhandover no PCA2no PCA2

Controle de potência Uplink-inner loop

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 39: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 38All rights reserved

RLS3

RLS2

RLS1 100100000000100

100110000011111

111111011111111

TS14TS13TS12TS11TS10TS9TS8TS7TS6TS5TS4TS3TS2TS1TS0

…… ……

10ms/frameGroup 1 Group 2 Group 3

RLS3

RLS2

RLS1 00000-1000000000

00000-1000010000

100000000010000

TS14TS13TS12TS11TS10TS9TS8TS7TS6TS5TS4TS3TS2TS1TS0

…… ……

TPC

TPC_tempi

00000-1000010000

TS14TS13TS12TS11TS10TS9TS8TS7TS6TS5TS4TS3TS2TS1TS0

…… ……

TPC_CMD

A potência é controlada a cada 5 time slotsA taxe de controle de potência é 300HZ

Com Com softsoft handoverhandover no PCA2no PCA2

Controle de potência Uplink-inner loop

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 40: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 39All rights reserved

l A freqüência de controle

[ TPC1, O controle de potência tem freqüência de 1500Hz

[ TPC2, O controle de potência tem freqüência de 300Hz

l Cenários de aplicação

[ Quando a UE está se movimentando em alta velocidade

(80Km/h), o controle de potência rápida inner-loop não pode

acompanhar as variações do canal com desvanecimento

rápido, produzindo ganho negativo. Nessa situação, PCA2 é

preferido.

ComparaComparaçção entre PCA1 e PCA2ão entre PCA1 e PCA2

Controle de potência Uplink-inner loop

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 41: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 40All rights reserved

CapCapíítulo 3 Controle de Potência de tulo 3 Controle de Potência de looploop fechadofechado

3.1 Visão geral do Controle de Potência de 3.1 Visão geral do Controle de Potência de looploop fechadofechado

3.2 Controle de potência 3.2 Controle de potência UplinkUplink innerinner looploop

3.3 Controle de potência 3.3 Controle de potência DownlinkDownlink innerinner looploop

3.4 Controle de potência 3.4 Controle de potência OuterOuter looploop

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 42: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 41All rights reserved

NodeB

Ajuste de SIRtar

Transmite TPC

Medida e comparação SIR

Medida e comparação de BLER

Outer loop

Inner loop L1

L3

10-100Hz1500Hz

Controle de potência de loop fechado no downlink

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 43: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 42All rights reserved

Controle de potência downlink Inner-loop

NodeB

Ajusta SIRtar

Transmite TPC em cada TS

Medida da SIR e comparaçãoAjusta Tx power

em 0.5, 1, 1 ou 2dB

1500Hz

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 44: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 43All rights reserved

l O UE deve estimar a potência downlink DPDCH/DPCCH e a SIR atual

l O UE pode gerar o TPC comparando o SIR estimado com SIR alvo

[ Se o SIR estimado é maior que o alvo, TPC é 0 (diminuição de potência)

[ Se o SIR estimado é menor que o alvo, TPC é 1 (aumento de potência)

l Os steps de controle de potência DL inner-loop podem ser de 0.5, 1, 1.5 ou 2 dB

Controle de potencia downlink Inner-loop

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 45: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 44All rights reserved

l Quando UE não está em soft handover

[O TPC gerado pelo UE é transmitido no domínio TPC do canal UL

l Quando UE está em soft handover, 2 modos de controle de potência podem ser usados. Tais modos são decididos decidido pelo DPC_mode:

[DPC_MODE=0,UE irá transmitir TPC em todo slot

[DPC_MODE=1,UE irá transmitir o mesmo TPC a cada 3 time slots

l Quando o UE não esta em sincronismo no canal de downlink, o TPC será 1 pois a UE não pode medir o SIR.

Controle de potência downlink Inner-loop

Como gerar o TPCComo gerar o TPC

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 46: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 45All rights reserved

l A potência de transmissão não pode ser maior que Maximum _DL_Power e não pode ser menor que o Minimum_DL_Power.

l Ajuste de Potência no downlink:

P(k) = P(k − 1) + PTPC(k) + Pbal(k)Onde

P(k-1) é a potencia anterior

PTPC(k) é o ajuste

Pbal(k) é o valor de correção

Como ajustar a potênciaComo ajustar a potência

Controle de potência downlink Inner-loop

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 47: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 46All rights reserved

Onde

PTPC(k) É o valor de ajuste

TPCest(k) É o valor de TPC de uplink

△TPC É o step de ajuste da potência de downlink(0.5, 1, 1.5 ou 2dB)

l PTPC(k)

[ Sem “Limited Power Raise Used”

=−=+

=0)(TPCifΔ1)(TPCifΔ

)(PestTPC

estTPCTPC k

kk

Como ajustar a potênciaComo ajustar a potência

Controle de potência downlink Inner-loop

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 48: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 47All rights reserved

Onde

l PTPC(k)

[ Com “Limited Power Raise Used”

=≥∆+∆=<∆+∆=

∆−

∆+=

0)(TPC ife_LimitPower_Rais)( and 1)(TPC ife_LimitPower_Rais)( and 1)(TPC if

0)(

est

est

est

kkkkk

kP TPCsum

TPCsum

TPC

TPC

TPC

PTPC(k) É o valor de ajuste

TPCest(k) É valor do TPC no uplink

△TPC É o step de ajuste da potência de downlink(0.5, 1, 1.5 or 2dB)

Power_Raise_Limit: O valor limite para Power ramping em um intervalo de tempo

DL_power_averaging_window_size:intervalo de tempo para power ramping (TS)

∑−

+−=

=∆1

1____)()(

k

SizeWindowAveragingPowerDLkiTPCsum iPk

Controle de potência downlink Inner-loop

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 49: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 48All rights reserved

O controle de potência inner-loop de downlink DPCCH inclui dois tipos: controle de potência inner-loop no modo comprimido e controle de potência inner-loop no modo não comprimido

Estrutura do timeslot de downlink DPCH:-PO1 define o offset de potência do bit de TFCI no downlink DPCCH para DPDCH.

-PO2 define o offset de potência do bit de TPC no downlink DPCCH para DPDCH.

-PO3 define o offset de potência do bit Pilot no downlink DPCCH para DPDCH-Os valores de PO1, PO2 e PO3 são definido pelo RNC.

Controle de potência downlink Inner-loop

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 50: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 49All rights reserved

Balanceamento da potência de Downlink

l Processo de balanceamento da potência de Downlink

[ SRNC pode monitorar a transmissão de cada NodeB. Se o SRNC determinar que o offser de potencia no soft handover estámuito alto, este irá comandar o processo DPB

l A inicialização e parada do processo DPB

[ O processo é iniciado quando o offset de potência entre dois RL for maior do o DPB initial threshold

[ O processo é interrompido quando o offsetde potência entre dois RL é menor do que o DPB stop threshold.

NodeB NodeB

Initiate theDPB process

DPB process

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 51: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 50All rights reserved

CapCapíítulo 3 Controle de Potência de tulo 3 Controle de Potência de looploop fechadofechado

3.1 Visão geral do Controle de Potência de 3.1 Visão geral do Controle de Potência de looploop fechadofechado

3.2 Controle de potência 3.2 Controle de potência UplinkUplink innerinner looploop

3.3 Controle de potência 3.3 Controle de potência DownlinkDownlink innerinner looploop

3.4 Controle de potência 3.4 Controle de potência OuterOuter looploop

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 52: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 51All rights reserved

Controle de potência outer loop

l A limitação do controle de potência inner loop

[ A finalidade do controle de potência inner loop do sistema WCDMA é manter uma certa relação sinal ruído no receptor.

l A característica do controle de potência outer-loop

[ O Qos que o NAS provê para a CN é o valor de BLER e não de SIR

l A relação entre o controle de potência inner-loop e controle de potência outer-loop

[ SIR target deve ser satisfeito de acordo com o requisito de decodificação corretamente. Entretanto, diferentes múltiplos percursos no ambiente de rádio necessitam de diferentes valores de SIR

[ O controle de potência outer-loop pode ajustar o SIR para obter um BLER estável no ambiente de rádio

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 53: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 52All rights reserved

Controle de potência uplink outer loop

NodeB UE

Transmitir TPC

Medir e comparar o SIR

Inner-loop

Set SIRtar

get the good qualityservice data get the good qualityservice data

Out loop

RNC

Medida do sinal recebido e

comparação da BLER em cada

TrCH

Set BLERtar

10-100Hz

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 54: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 53All rights reserved

NodeB

set SIRtar

Transmit TPC

Medir e comparar o SIR

Medir e comparar o BLER

Outer loop

Inner loop L1

L3

10-100Hz1500Hz

Controle de potência downlink outer loop

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 55: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 54All rights reserved

Controle de potência outer loop

Etapa de ajuste de SIR Etapa de ajuste de SIR targettarget

−=∆

etBLERtetBLERtBLERmeastepSIRAdjustSoefficientSIRAdjustcSIRtar

argarg**

Onde

SirAdjustStep: Step de ajuste de controle de potência Outer loop

SirAdjustFactor: Coeficiente para controle de potencia outer loop

BLERest: BLER estimado

BLERtar: BLER Target

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 56: 19 wcdma controle de potencia

HUAWEI TECHNOLOGIES CO., LTD. Page 55All rights reserved

Controle de potência outer loop

l Comando de controle de potência uplink outer loop transmitido para o NodeBatravés do DCH-FP

Node B SRNC

……

OUTER LOOP PC

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 57: 19 wcdma controle de potencia

www.huawei.com

Obrigado

PDF created with pdfFactory Pro trial version www.pdffactory.com