RD-OM-03-Rev01
RD-OM-03-Rev01
RD-OM-03-Rev01
RD-OM-03-Rev01
RD-OM-03-Rev01
TWCTRC
TRB
20-200
Semi-Hermetic
Mimic Diagram
11-00.01
Semi-HermeticCopeland Bitzer
Low VoltageOverload
Unloader
5/8"1mm2mm
RD-OM-03-Rev01
ST-52
(mechanical expansion)
3/4"ASTM B75-85, UNC12200
ST-52(mechanical expansion)
200psig400psig
part winding
Multi- step digital temperature controller
on/off Reset Switch
Low & High pressure switch
Oil Pressure Switch
Mini- PLC
Schiele, Telemechanique DanfossMerlin
Gerlin
IT
DanfossAlco
RD-OM-03-Rev01
440360350-380
7.2:1 (°F140
(psig) 313(°F40
(psig)92(°F150
(°F 64120
(°F 5 (°F40
(psig)10 (°F
50
15°F
RD-OM-03-Rev01
RD-OM-03-Rev01
(TWC)
(TRC)
RD-OM-03-Rev01
RD-OM-03-Rev01
RD-OM-03-Rev01
RD-OM-03-Rev01
TWC
RD-OM-03-Rev01
(CN:11-00.01)
6"8"
6"8"
RD-OM-03-Rev01
Vibration Pad
FRONT VIEW
CONC.FOUND.
U-BEAM
DETAIL-A
Ø 20
A
RD-OM-03-Rev01
(Flow Switch)
Flow Switch
RD-OM-03-Rev01
55 °F
65 °F
3"
(150 psig)
55 °F
65 °F
(by pass)
VXT
RD-OD-01
RD-OM-03-Rev01
SUCTION
8
DISCHARGEGATE
VALVES
TERMOMETER
GATE VALVES
FLEXIBLE CONNECTION
CHILLED WATER SUPPLY OUTCHILLED WATER RETURN IN
FLOW SWITCH
3"MIN
GATE VALVES
TERMOMETER SEE NOTE
MAKE UP
WATER INLET
OVER FLOW
WATER OUTLET
DRAIN
FLOW SWITCH
GATE VALVES
1.SHALL HAVE A SCALE OF 20 F-120 F.
2.SHALL BE OF THE SEPERABLE SOCKET TYPE. NOTE:
3.SHALL HAVE EXTENDED NECK WHERE REQUIRED FOR INSULATION.
RD-OM-03-Rev01
24"
24"
TRCRAR
100ft (30m)
10 °F
ASHRAE
115 °F
RD-OM-03-Rev01
ASHRAE System Handbook
5 ft3 ft
1/16"1/8"
2 ft
ANSIASHRAE
ASHRAEANSI/ASHRAE 15-1978
ANSI B31.5-1974
TRC
RD-OM-03-Rev01
R22
R22
RD-OM-03-Rev01
(Evacuate)
RD-OM-03-Rev01
HOT GAS LINE
LIQUID LINE
CHILLED WATER RETURN IN CHILLED WATER SUPPLY OUT
FLOW SWITCH
FLEXIBLE CONNECTION
GATE VALVES
TERMOMETER
GATE VALVES
NOTE: REFER TO THE AIR-COOLED CONDENSER CATALOGUE
CN:03-01.02 FOR NOTES ON CONDENSER PIPING.
PITCH
PITCH
TO AIR-COOLED CONDENSERFROM AIR-COOLED CONDENSER
"RAR" CONDENSER UNIT
INSTALLATION - 'RAR' UNIT WITH DUAL SPLIT SYSTEM
PITCH
HOT GAS LINE
PITCH
PITCH
SUITABLE SLEEVE
(TYP.)
PITCH
LIQUID LINE
INSTALLATION - 'RAR' UNIT WITH SINGLE COMPRESSOR SYSTEM
NOTES :
1. Hot gas lines should rise above refrigerant level in
condenser circuit. Double riser may be required
; check compressor minimum capacity.
2. Trap should be installed on hot gas lines to
prevent condenser oil and refrigerant vapor
migration from accumulating on compressor heads
during off cycle.
3. Pitch all horizontal lines downward in the direction
of refrigerant flow.
4. For piping length greater than 50 ft, provide support
to liquid and gas lines near connection to coil.
5. All piping must follow standard refrigerant piping
practices.
SEE NOTE 1
SEE NOTE 3
SEE NOTE 2
SEE NOTE 3
SEE NOTE 1
SEE NOTE 1
SEE NOTE 3
RD-OM-03-Rev01
TWCTRC
TRC
R22
R2225psig
150psig
150psig
RD-OM-03-Rev01
RD-OM-03-Rev01
NEC
+5°C
Compressor Name Plate
IT
RD-OM-03-Rev01
+5°C
RD-OM-03-Rev01
50°F
2 psig
10-15 °F
30-40 °F
15°F
240 psig
127 °F
116 °F
11 °F
10-15 °F
RD-OM-03-Rev01
10-15 °F
10-15 °F
15° F
6"
45 °F
- 35 °F
10 °F
RD-OM-03-Rev01
50 psi65-70 psi
10-15°F
(pump out)
1520LLSV
15psig
RD-OM-03-Rev01
0 psig
(pump out)
(pump out)
RD-OM-03-Rev01
Thermal Overload Thermal Overload
L.R.A
RD-OM-03-Rev01
Sub-cooling
Low Ambient
Thermal overload
Overload
Sub-cooling
RD-OM-03-Rev01
±2 °F
T
(TXV)
8"-10"
RD-OM-03-Rev01
Sub-cooling
Overload
Sub-cooling