v 2 1 automação para sistemas vrf v 02 2011

21
Automação para sistemas LG Academia de Ar Condicionado Air Conditioning Academy (VRF – R410A)

Upload: agassis-rodrigues

Post on 26-Jun-2015

452 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: V 2 1 automação para sistemas vrf v 02 2011

Automação para sistemasLG Academia de Ar

Condicionado

Air Conditioning Academy

(VRF – R410A)

Page 2: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 2Air Conditioning Division

NetworkNetwork Solution Solution

Page 3: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 3

Controles Centrais

Controle & Sistema de Controle & Sistema de GerenciamentoGerenciamento

Total AC Manager System

Pequenos Edifícios

• LonWorks

BMS Gate wayBMS Gate way

Integração com rede aberta

Home AutomationHome Automation

LGAP Protocol LGAP Protocol

Grandes Edifícios

• BACnet

Edifícios Médios

Controles Centralizados - Disponibilidade

2 - Line Up

Page 4: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 4

System Architecture System Architecture

Multi V System

MPS

PI485

Para instalações de médio porte

Máximo64

evaporadoras

PossibilidadeExpansão para

128Evaporadoras

3 - Controles

4 - AC Smart

Page 5: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 5

4F

3F

2F

1F

4F user’s ID & PW

3F user’s ID & PW

2F user’s ID & PW

1F user’s ID & PW

Administrator can control all units

Internet

Internet Explorer

Web Access

Web Access Function is available basically, so you can access AC Smart anywhere by using Internet Explorer.Web Access level is distinguished to 2 Level; Administrator & User. When login to administrator: Can register user’s ID & Password (max 10 users), and allocate accessible address for each user; can operate all indoorWhen login to User: Can operate allocated indoor for each user.

3 - Controles

4 - AC Smart Acesso via Web Browser

Page 6: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 6

Multi Language

On setting the language, all GUI will be changed to the selected language.

[English, French, Spanish, Italian,German,Dutch,Russian]

3 - Controles

4 - AC Smart Multi Linguagem

Page 7: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 7

• (sT : Set Temp.) :18~30℃

• dT (Difference Temp.) : 1~7℃

• aT (Alpha Temp.) : 2℃

• Upper Limit (sT+dT+aT) : Change Point(Heat → Cool)

• Lower Limit (sT-dT-aT) : Change Point(Cool → Heat)

Auto Changeover

Modo Automático

3 - Controles

4 - AC Smart

Page 8: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 8

Individual Function Control Locking

Setting Temperature range restriction

If Function Locking is enabled in AC Smart, then you cannot change the locked function in the individual remocon.(For example, if Temperature is locked in the AC Smart, you can not change the setting temperature in the remocon,

EnergySaving

Temp 26 ℃

temperature Change is impossible.Other function is possible.

EnergySaving

Temp 26 ℃

temperature Change is possibleonly in the range set from AC Smart

26 Fix℃

24~28 adjustable℃

24~28℃

Total, Mode,Temperature,Speed Lock

Bloquear ou limitar temperatura

4. AC Smart3 - Controles

4 - AC Smart

Page 9: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 9

Emergency Stop

Fire

Occurre

n

ce!

Connection with fire alarm in non_voltage contact.

On detecting, all connected air_conditioner will be stop

Back of the AC Smart

Fire Alarm Sensor

non_power contact

Parada de Emergência

Fire D

etec

tion

3 - Controles

4 - AC Smart

Page 10: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 10

Easy Upgrade

System Data Backup & Upload is Possible

1. Save the target program to USB2. Connect “mini USB to Standard USB Jack(Get from communication equipment market)”

to AC Smart and connect USB

USB

It will take about 10 minutes.

After completing upgrade, automatically

restart the

AC Smart Program,

then remove the USB.

Fácil Upgrade

3 - Controles

4 - AC Smart

Page 11: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 11

AC 220V

Maximum 64 Units

Maximum 128 Units

When using Expansion Kit

128 Expansion Kit

(PQCSE440U0)

128 Expansion Kit

By using Expansion Kit,

Maximum 128 Indoor Unit can be connected

Expandir de 64 para 128 U.I

3 - Controles

4 - AC Smart

Page 12: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 12

Operation Ratio Calculation

In AC Smart Monitoring, report of each indoor’s operation time & operation ratio, is available.

By using this, you can distribute the power consumption by referring to the information.

Cálculo da participação de cada U.I

3 - Controles

4 - AC Smart

Page 13: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 13

3 - Controles

4 - AC Smart Cálculo da participação de cada U.I

Page 14: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 14

Time Limit Control

New Auto control of AC Smart, Time Limit control. You can set the time limit 1~4Hr, and set

available day of week.

In time limit function for available period, indoors can operate up to maxim setting time

continuously.

For example: Set as 2 Hr, and available on Saturday & Sunday. When someone operate indoor,

AC Smart will

check the continuous operating time. If the time is over 2hr, AC Smart

automatically stops the indoor operation.

Register groupLimit Time Set : 1 ~ 4 hr.

Set available day of week

Turn On the air conditionerAfter limited time

Automatically stop air conditioner

Controle do tempo de operação

3 - Controles

4 - AC Smart

Page 15: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 15

Access Level (3 Level)

In AC Smart controller access level is distinguished to 3 Level; Installer, Administrator & User.

When login to Installer: Can register administrator & user’s ID & Password, and register Unit;

can operate all Function

When login to Administrator: Can operate all Function except unit register, id & pw register.

When login to User: Can operate only control & monitoring.

Acesso como Administrador ou Usuário

Log in for installation

professional

Log in for administrator

Log in for general user

3 - Controles

4 - AC Smart

Page 16: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 16

Auto e-mail

New e-mail function was applied. By using this function, you can register e-mail address, so when

error happen or some fixed time automatic e-mail will be executed. So customer can easily

maintain all connected air conditioner’s status.

4F

3F

2F

1F

Auto e-mail sending

E-mail Automático

Internet

3 - Controles

4 - AC Smart

Page 17: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 17

Digital Watch

When not using Central Controller, AC Smart can display Digital Watch

Screen Saver

Relógio digital na tela

3 - Controles

4 - AC Smart

Page 18: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 18

3 - Controles

7 - BAC Net Gateway junto com controle escravo

Page 19: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 19

Do Unit connection

By using Do Unit, AC Smart can control on/off of other equipment. It can easily register

another equipment and control it.

Do KIT : PQNFP00T0

BUS_A

BUS_BPower of Load

ACP or ACSmart

3 - Controles

8 - Do KIT : PQNFP00T0 – Controle de Dispositivos Externos

Page 20: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 20

Pump Power Source

Option : Do Kit (PQNFP00T0)

3 - Controles

8 - Do KIT : PQNFP00T0 – Controle de Dispositivos Externos

Page 21: V 2 1 automação para sistemas vrf v 02 2011

Copyright 2010 @LG Electronics / AC Company All Rights ReservedMulti V 21