UNIVERSIDADE ESTADUAL DE CAMPINAS
FACULDADE DE CIÊNCIAS MÉDICAS
TATIANE MELINA GUERREIRO
CONTAMINANTES EM ALIMENTOS:
DETERMINAÇÃO DE MARCADORES QUÍMICOS POR
ESPECTROMETRIA DE MASSAS
CONTAMINANTS IN FOOD:
CHEMICAL MARKERS DETERMINATION BY MASS SPECTROMETRY
CAMPINAS
2018
TATIANE MELINA GUERREIRO
CONTAMINANTES EM ALIMENTOS:
DETERMINAÇÃO DE MARCADORES QUÍMICOS POR
ESPECTROMETRIA DE MASSAS
CONTAMINANTS IN FOOD:
CHEMICAL MARKERS DETERMINATION BY MASS SPECTROMETRY
Tese apresentada à Faculdade de Ciências Médicas da Universidade
Estadual de Campinas como parte dos requisitos exigidos para a
obtenção do título de Doutora em Ciências
Thesis presented to the Faculty of Medical Sciences of the University
of Campinas as part of the requirements to obtain the Doctor of
Science degree
ORIENTADOR: RODRIGO RAMOS CATHARINO
ESTE EXEMPLAR CORRESPONDE À VERSÃO
FINAL DA TESE DEFENDIDA PELA
ALUNA TATIANE MELINA GUERREIRO, E ORIENTADA PELO
PROF. DR. RODRIGO RAMOS CATHARINO.
CAMPINAS
2018
BANCA EXAMINADORA DA DEFESA DE DOUTORADO
TATIANE MELINA GUERREIRO
ORIENTADOR: PROF. DR. RODRIGO RAMOS CATHARINO
MEMBROS:
1. PROF. DR. RODRIGO RAMOS CATHARINO
2. PROFA. DRA. MÔNICA SIQUEIRA FERREIRA
3. PROF. DR. SEVERINO MATIAS DE ALENCAR
4. PROFA. DRA. CIBELE ZANARDI ESTEVES
5. PROFA. DRA. IZABELA DUTRA ALVIM
Programa de Pós-Graduação em Fisiopatologia Médica da Faculdade de Ciências
Médicas da Universidade Estadual de Campinas.
A ata de defesa com as respectivas assinaturas dos membros da banca
examinadora encontra-se no processo de vida acadêmica do aluno.
Data: 14/08/2018
“Acordar para quem você é requer desapego de quem você imagina ser”
Alan Watts
AGRADECIMENTOS
Esta página é sempre a mais difícil de ser escrita. Não que eu não me sinta grata,
mas pelo fato do quão difícil que é pontuar somente algumas pessoas para se agredecer por
tudo que passou e pelos frutos que ando colhendo hoje em dia. Este trabalho contou com a
participação de muita gente e muitos momentos. Esta tese é o resultado de algo que eu
idealizei há 4 anos atrás e que hoje chega ao fim. Por isso, sou muito grata por todos que
tiveram a oportunidade de viver estes últimos anos comigo.
Nada melhor do que começar os agradecimentos com vocês, amigos do laboratório:
Diogo, Mônica, Cibela, Jeany, Mohamed, Marta, Luisa e Estela muito obrigada por
fazerem meus dias mais alegres, por toda ajuda no que fosse preciso, por me trazer queijo,
por todas as conversas e por todas as risadas fica aqui meu abraço apertado para cada um de
vocês! Por todo apoio e por me (des)orientar em cada etapa deste doutorado, muito
obrigada Prof. Rodrigo! Só alegria, sempre!
Por conviver 24 horas comigo, vivendo todas as minhas emoções, cada alegria, cada
lágrima, cada garrafa de vinho, cada receita que dá errado, cada viagem, cada copo de
cerveja, cada machucado, cada manhã às 4h30, cada reggaeton... Fer, eu não tenho palavras
para descrever o quanto você é importante para mim... Muito obrigada por todo
companheirismo e amor. Eu te amo!
E por último, àqueles que sempre estiveram aqui para me proteger, me ensinar, me
guiar, me motivar e principalmente por sempre acreditar em mim, mesmo quando nem eu
mesma acreditei, muito obrigada Pai e Mãe! Eu tenho muito orgulho de ser sua filha! E não
poderia esquecer da minha companheira de vida, aquela pessoa que a gente briga e mesmo
assim sabe que nunca vai deixar de amar, muito obrigada Bilu! O pai e a mãe não poderiam
ter acertado tanto quando fizeram você!
Muito obrigada por cada oportunidade que pude viver nesses últimos anos e também
por cada momento de angústia, que sempre trouxeram muito aprendizado e crescimento.
Muito obrigado doutorado, por além de ciência ter me ensinado muito sobre a vida!
E que venha a próxima aventura... Valeu!
RESUMO
A qualidade de alimentos é assegurada através dos limites de contaminantes químicos designados
pelas legislações para o emprego de um controle de qualidade eficaz. A busca por métodos
analíticos mais rápidos e com alta eficiência é o que move a pesquisa aplicada à área de ciência de
alimentos. O emprego da espectrometria de massas é destaque na análise de marcadores químicos
em alimentos, por ser uma técnica versátil para o estudo e identificação por análise direta de
possíveis contaminantes. Além disso, a união de técnicas modernas de espectrometria de massas
com a metabolômica, uma plataforma capaz de integrar dados estatísticos e experimentais para
obtenção de resultados analíticos de alta confiabilidade, torna esse segmento extremamente fértil
para a realização de melhorias e desenvolvimento. Para a realização destas análises, os compostos
podem ser previamente escolhidos (target analysis) ou identificados pós-análise (metabolic
fingerprinting). Neste contexto, amostras de diversos alimentos populares e amplamente
consumidos no Brasil, como leite, carne vermelha e a bebida cachaça foram analisados
empregando-se esta combinação com o objetivo de identificar marcadores químicos relacionados
aos possíveis contaminantes destes alimentos.
Palavras chave: Contaminantes. Segurança Alimentar. Metabolômica. Espectrometria de Massas
ABSTRACT
Food quality is ensured through the limits of chemical contaminants designated by legislation for
the use of effective quality control. The search for faster and more efficient analytical methods is
what moves applied research to the area of food science. The use of mass spectrometry is
highlighted in the analysis of chemical markers in foods, being a versatile technique for the study
and identification by direct analysis of possible contaminants. Moreover, the union of modern
techniques of mass spectrometry with metabolomics, a platform capable of integrating statistical
and experimental data to obtain highly reliable analytical results, makes this segment extremely
fertile for improvement and development. For the accomplishment of these analyzes, the
compounds can be previously chosen (target analysis) or identified post-analysis (metabolic
fingerprinting). In this context, samples of several popular and widely consumed foods in Brazil,
such as milk, beef meat and the beverage cachaça were analyzed using this combination in order to
identify chemical markers related to the possible contaminants in these foods.
Palavras chave: Contaminants. Food Safety. Metabolomic. Mass Sepectrometry.
LISTA DE FIGURAS
Figura 1 Processo de ionização por spray de elétrons. (adaptado de Cech & Christie,
2001)..................................................................................................................... 21
Figure 1 PLS-DA scores plot showing clustering among adulterated milk samples,
separated from fresh raw milk. (A) Scores plot of sodium hydroxide using
positive mode data. (B) Scores plot of sodium hypochlorite using positive mode
data. (C) Scores plot of hydrogen peroxide using the negative mode data. (D)
Scores plot of the formaldehyde using the negative mode data..................... 41
Figure 2 DI-HRMS fingerprints in the positive mode of adulterated milk samples (A =
fresh raw milk/control; B = milk added 1 % v/v of sodium hydroxide solution; C
= milk added 1 % v/v of sodium hypochlorite solution)................................... 42
Figure 3 DI-HRMS fingerprints in the negative mode of adulterated milk samples (A =
fresh raw milk/control; B = milk added 1 % v/v of hydrogen peroxide solution;
C = milk added 1 % v/v of formaldehyde solution)............................................. 43
Figure 1SM PLS-DA scores plot showing clustering among adulterated milk samples with
concentration of adulterant of 2.5% v/v separated from fresh raw milk. (A =
Scores plot of sodium hydroxide solution using positive mode data; B = Scores
plot of sodium hypochlorite solution using positive mode data; C = Scores plot
of hydrogen peroxide solution using the negative mode data; D = Scores plot of
the formaldehyde solution using the negative mode data)............................... 49
Figure 2SM PLS-DA scores plot showing clustering among adulterated milk samples with
concentration of adulterant of 5% v/v separated from fresh raw milk. (A =
Scores plot of sodium hydroxide solution using positive mode data; B = Scores
plot of sodium hypochlorite solution using positive mode data; C = Scores plot
of hydrogen peroxide solution using the negative mode data; D = Scores plot of
the formaldehyde solution using the negative mode data)............................... 50
Figure 3SM PLS-DA scores plot showing clustering among adulterated milk samples with
concentration of adulterant of 10% v/v separated from fresh raw milk. (A =
Scores plot of sodium hydroxide solution using positive mode data; B = Scores
plot of sodium hypochlorite solution using positive mode data; C = Scores plot
of hydrogen peroxide solution using the negative mode data; D = Scores plot of
the formaldehyde solution using the negative mode data)............................... 51
Figure 1 HRMS spectra of the beef meat samples showing the presence of five
contaminants in all pieces of beef meat that were in contact with the vacuum-
plastic packaging. A: negative control butcher's shop beef meat; B: packaging
spectrum; C: packed beef meat spectrum............................................................. 57
Figure 1 Scheme of the solution preparation for the standard addition method................. 68
Figure 2 Sandwich injection scheme.................................................................................. 68
Figure 3 EIC chromatogram of solutions with 6 and 30 g/L of sugar and MS spectrum of
365 (sucrose).................................................................................................... 70
Figure 4 EIC chromatogram of 6 g/L of sugar (A) and with a sample of cachaça (B)
before and after QuEChERS extraction, injecting only the organic layer for both
samples......................................................................................................... 71
Figure 5 Overlapping chromatogram of standard addition method, which shows the
gradual increase of the peak area of ethyl carbamate........................................... 73
Figure 6 Comparison between the standard addition curve (A) and the external calibration
curve (B) for quantification of the ethyl carbamate............................ 75
LISTA DE TABELAS
Quadro 1 Comparação entre as diferentes tecnologias utilizadas em
metabolômica. (Adaptado de Wishart, 2008)...................................... 19
Table 1 List of compounds found for each of the types of adulterants used.
*METLIN ID....................................................................................... 45
Table 1 Contaminants found in meat samples from plastic package. (a
Presented adducts are in accordance with Keller et al, 2008 (Keller,
Sui, Young, & Whittal, 2008))............................................................ 56
Table 1 Sugar percentage removal by EIC peak area....................................... 69
Table 2 Recovery results by standard addition and external calibration
methods. (n=3)..................................................................................... 74
Table 3 Mean concentration (MC, n=3), absolute error of the measurements
(n=3) and final concentration (FC) of ethyl carbamate in the tested
cachaças samples [commercial (Comm) and craft]............................ 76
LISTA DE ABREVIAÇÕES E SIGLAS
MS Espectrometria de Massas, do inglês Mass Spectrometry
QuEChERS Do inglês Quick, Easy, Cheap, Effective, Rugged, Safe
GC Cromatografia Gasosa, do inglês Gas Chromatography
LC Chromatografia Líquida, do inglês Liquid Chromatography
QqQ Triplo quadrupolo
MRM Monitoramento de Reações Múltiplas, do inglês Multiple Reaction Monitoring
EI Ionização por Elétrons, do inglês Electron Ionization
ESI Ionização por Spray de Elétrons, do inglês Electrospray Ionization
NMR Espectroscopia de Ressonância Magnética Nuclear, do inglês Nuclear Magnetic
Ressonance Spectroscopy
HRMS Espectrometria de Massas de Alta Resolução, do inglês High-Resolution Mass
Spectrometry
MALDI Ionização e Dessorção a Laser Assistida por Matriz, do inglês Matrix-Assisted Laser
Desorption/Ionization
CID Dissociação Induzida por Colisão, do inglês Collision-Induced Dissociation
DOP Denominação de Origem Protegida
IGP Indicação Geográfica Protegida
EPG Especialidade Tradicional Garantida
PCA Análise de Componente Principal, do inglês Principal Component Analysis
PLS-DA Análise Discriminante por Mínimos Quadrados Parciais, do inglês Partial Least-
Squares Discriminant Analysis
SUMÁRIO
1. INTRODUÇÃO .......................................................................................................................... 13
1.2 Contaminantes em Alimentos ................................................................................................... 14
1.3 Metabolômica em Alimentos .................................................................................................... 15
1.4 Técnicas analíticas para determinação de substâncias em alimentos utilizando a
Metabolômica ................................................................................................................................. 16
1.4.1 Técnicas Cromatográficas .....……………….............……………...………..…................... 17
1.4.2 Curva de Calibração e Adição de Padrão .............................................................................. 17
1.4.3 Espectrometria de Massas ...........…………….....................................................….............. 18
1.4.4 Ionização por Elétrons (EI) ......................................................….......................................... 20
1.4.5 Ionização por Spray de Elétrons (ESI) ................................................................................... 20
1.4.6 Tandem MS (MS/MS) ........................................................................................................... 21
1.4.7 Monitoramento de Reações Múltiplas (MRM)....................................................................... 22
1.4.8 Espectrometria de Massas de Alta Resolução ...............……………………........................ 23
1.5 Produtos Alimentícios ............................................................................................................... 23
1.5.1 Leite ....................................................................................................................................... 23
1.5.2 Carne ...................................................................................................................................... 27
1.5.3 Cachaça ......................................................……...…………….......…….............................. 29
2. OBJETIVOS ............................................................................................................................... 32
2.1 Objetivos Específicos ................................................................................................................ 32
3. METODOLOGIA ....................................................................................................................... 33
3.1 Infraestrutura utilizada no projeto ............................................................................................. 33
3.2 Análise Estatística dos Dados ................................................................................................... 33
3.3 Propostas Estruturais ................................................................................................................. 33
4. RESULTADOS ........................................................................................................................... 34
4.1. Artigo I: Evaluating the Effects of the Adulterants in Milk using Direct-Infusion High-
Resolution Mass Spectrometry......................................................................................................... 34
4.2 Artigo II: Migration from Plastic Packaging into Meat ........................................................... 52
4.3 Artigo III: New Approach of QuEChERS and GC-MS Triple-Quadrupole for the
Determination of Ethyl Carbamate content in Brazilian cachaças ................................................ 62
5. DISCUSSÃO GERAL ................................................................................................................ 80
6. CONCLUSÃO ............................................................................................................................ 82
7. REFERÊNCIAS .......................................................................................................................... 83
8. ANEXOS .................................................................................................................................... 88
13
1. INTRODUÇÃO
Atualmente, existe uma grande tendência no investimento em pesquisas capazes
de realizar análises essenciais que garantam a qualidade e a segurança de alimentos. A
avaliação e o desenvolvimento de métodos analíticos adequados para as necessidades de
um país produtor como o Brasil, bem como a natureza dos seus produtos, requer dados
confiáveis e assertivos sobre os alimentos comercializados ou potencialmente
comercializáveis, tanto internamente quanto no exterior. O desenvolvimento de uma
infraestrutura analítica eficiente garante à população alimentos nutritivos, com altos
níveis de segurança em relação à contaminantes e, portanto, alimentos considerados de
alta qualidade. Além disso, é possível evitar a rejeição de produtos que possuem
potencial para exportação, visto que uma infraestrutura analítica eficiente possibilita a
adequação com os mais altos padrões de qualidade internacionais.
Dessa forma, o uso de técnicas instrumentais rápidas, com alta precisão,
exatidão, versatilidade e simplicidade operacional torna-se extremamente desejável
dentro do escopo da análise de alimentos1,2. Nesse segmento, figuram com grande
destaque as técnicas baseadas em espectrometria de massas (MS, Mass Spectrometry).
O desenvolvimento de novas fontes de ionização, as melhorias em analisadores (como
por exemplo o aumento de sua sensibilidade e especificidade) e a criação de sistemas de
aquisição de dados com grande rapidez qualitativa e quantitativa contribuíram para a
aplicação da MS na análise de diversos compostos encontrados em alimentos3,4.
Neste cenário promissor, a MS tornou-se a principal ferramenta utilizada na
metabolômica de alimentos. Com início no final dos anos 90, a análise do metaboloma e
da impressão digital metabólica (metabolic fingerprinting) conquistaram grande
aplicação em rotinas de análises de alimentos5,6. Agilidade na interpretação de dados e
métodos simplificados para elucidação do perfil químico de amostras são características
que trouxeram grande interesse na última década, tanto por parte da indústria quanto
pela academia, visando incorporar e desenvolver essas metodologias em laboratórios
especializados. Além disso, a exigência de estratégias analíticas altamente refinadas
para garantir a qualidade de produtos que possuem composição nutricional superior
fazem com que a plataforma metabolômica esteja em nível privilegiado, inclusive, nos
próximos anos6,7.
14
1.2 Contaminantes em Alimentos
Os alimentos possuem uma composição complexa que engloba de maneira geral
seus macronutrientes (proteínas, carboidratos e gorduras) e micronutrientes (vitaminas e
minerais). No entanto, esta composição também pode ser uma fonte importante de
compostos com potencial tóxico. Contaminantes podem ser definidos como qualquer
substância indesejável presente nos alimentos, podendo ser classificados como fatores
antinutricionais ou compostos naturalmente presentes na matriz de determinado
alimento (p. ex.: oxalatos em espinafre); compostos adicionados intencionalmente ou
acidentalmente (p. ex.: corpos estranhos, aditivos alimentares, pesticidas, medicamentos
veterinários, componentes da embalagem) e, por fim, compostos originados durante o
processamento (p. ex.: aminas aromáticas heterocíclicas, hidrocarbonetos policíclicos
aromáticos, nitrosaminas, acrilamidas, carbamatos, entre outros)8.
A contaminação alimentar é um assunto de grande preocupação pois pode
acarretar em diversos danos a saúde, o que resulta na aplicação de regulamentações
rigorosas de seus níveis de concentração tanto pelo governo nacional quanto
internacional, através da Comissão do Codex Alimentarius9. Este é um problema
conhecido, que possui registro na história de mais de 8.000 anos atrás e, com o
crescimento do agronegócio e da globalização, tornou-se recorrente em todo o mundo10.
Além disso, a contaminação alimentar tornou-se mais grave nos últimos anos devido ao
desenvolvimento da indústria e à consequente poluição ambiental, o que torna cada vez
mais difícil proteger os consumidores destes possíveis eventos11.
A análise de contaminantes químicos relevantes é uma parte essencial dos
programas de testes de segurança de alimentos para garantir a segurança do consumidor
e a conformidade com os limites regulatórios. Técnicas analíticas modernas podem
determinar contaminantes químicos conhecidos em matrizes alimentares complexas em
níveis de concentração muito baixas. Além disso, eles também podem ser efetivos na
descoberta e identificação de contaminantes químicos novos ou inesperados12,13. Desta
forma, devido a importância global de se manter tanto a segurança quanto a qualidade
alimentar temos que o desenvolvimento de novas técnicas analíticas responsáveis por
auxiliar na identificação de contaminantes em alimentos, são cruciais para que estas
substâncias sejam reguladas de maneira eficiente e concisa pelos órgãos reguladores.
15
1.3 Metabolômica em Alimentos
Durante o final do século 20 e o início do século 21, as metodologias clássicas
de pesquisa biomédica abriram espaço para uma abordagem holística introduzida pela
genômica, proteômica, transcriptômica e metabolômica, que incluíram novas estratégias
analíticas com o objetivo de identificar e quantificar biomarcadores 14,15. De maneira
geral, biomarcadores, ou marcadores químicos, são definidos como moléculas que
traduzem uma característica; indicando um estado ou uma resposta que confere
identidade às amostras analisadas, permitindo traçar correlações entre diferentes
grupos15,16. Assim, a definição mais aceita de metabolômica é a de que este é um ramo
da ciência que trata da pesquisa e análise qualitativa e/ou quantitativa de todos os
metabólitos de um sistema ou processo bioquímico17. Esses metabólitos são intrínsecos
ao nível de atividade bioquímica (ou fisiopatológica) desse organismo, via metabólica
ou processo, facilitando sua correlação com o fenótipo ou resultado desenvolvido. A
expansão da utilização de estratégias metabolômicas é salientada em estudos de
diferentes áreas do conhecimento, como doenças humanas18, toxicologia 19, análise de
plantas 20, nutrição humana 21 e, mais recentemente, controle de qualidade e processo
22,23.
Atualmente a metabolômica em alimentos ocupa um lugar de destaque14,24, pois
a preocupação em relação aos alimentos deixou de ser apenas relacionada com a
prevenção de sua deterioração e extensão de sua vida de prateleira, enfocando hoje em
dia a análise detalhada de seus macro e micronutrientes (água, carboidratos, proteínas,
lipídios, vitaminas e sais minerais). Evidências crescentes demonstram que há uma
estreita relação entre a dieta e algumas doenças, o que fornece grandes investimentos,
tanto governamentais como particulares, para impulsionar as atividades de pesquisa
relacionadas à metabolômica24,25. As propriedades médico-preventivas, além do valor
nutricional dos constituintes naturais dos alimentos, de um lado, e os efeitos tóxicos de
constituintes e contaminantes do outro, tornaram prioritário o conhecimento da total
composição química dos alimentos através do emprego das mais diversas técnicas
instrumentais, utilizando a ferramenta ômica25. Em diversos países, hoje não é mais
permitida a comercialização de alimentos sem que a sua composição seja do
conhecimento do consumidor. Os benefícios decorrentes da redução de problemas
relacionados à saúde, dos gastos com medicamentos e de atendimento hospitalar,
aliados à maior produtividade de uma população sadia, retribuem os investimentos em
pesquisas que visam proporcionar uma dieta adequada e saudável para a população.
16
Estes esforços requerem a busca por novas tecnologias para a análise de alimentos e,
nesse contexto, a aplicação da ferramenta metabolômica vem trazendo diversos
benefícios 24.
A metabolômica é didaticamente dividida em duas estratégias: análise de
moléculas-alvo (“target analysis”) ou análise de identidade amostral (“metabolic
fingerprinting”). Como os próprios nomes sugerem, na primeira deseja-se estabelecer o
foco em uma via metabólica ou molécula em particular, onde métodos bastante
específicos são desenvolvidos para essa finalidade. A segunda, por sua vez, tem por
finalidade estabelecer uma “impressão digital” da amostra, baseando-se em sinais
característicos de um grupo particular de moléculas/classes de compostos presentes na
mesma, estabelecendo um “padrão químico”, muitas vezes mesmo sem a necessidade de
quantificação e/ou elucidação estrutural26. Os compostos identificados através destas
estratégias metabolômicas podem ser validados e, posteriormente, utilizados como
biomarcardores, também chamados de “compostos identificadores”, que conferem à
amostra características importantes do ponto de vista de processamento, controle de
qualidade, segurança e autenticidade de alimentos, sempre mediante à sua presença ou
ausência27.
No Brasil há escassez de dados em pesquisa de metabolômica utilizada como
ferramenta para o controle e rastreabilidade de alimentos28. A análise de constituintes e
marcadores químicos presentes nos alimentos e seus efeitos metabólicos são
desafiadores, uma vez que impactam diretamente nas pesquisas sobre nutrição e na
forma como o alimento é introduzido na sociedade. Desta forma, o acompanhamento
dos marcadores químicos associados aos alimentos desde a matéria-prima até o produto
final, é essencial para garantir qualidade e segurança ao consumidor. O uso da análise
metabolômica suportada por técnicas instrumentais rápidas com alta precisão, exatidão
e versatilidade tornam-se indispensáveis na área de alimentos. As técnicas de MS
ocuparam um papel de destaque na última década, pois preenchem tais requisitos28.
Portanto, aliar a metabolômica à técnicas de MS torna-se uma tarefa de suma
importância tecnológica e econômica para o campo de anáise de alimentos no Brasil.
1.4 Técnicas analíticas para determinação de substâncias em alimentos utilizando a
Metabolômica
A maior parte dos contaminantes químicos conhecidos nos alimentos são
pequenas moléculas orgânicas. Exceto para adulterantes de alto nível, eles estão
17
tipicamente presentes em alimentos em baixas concentrações (partes por milhão, bilhão
ou trilhão). A análise de biomarcadores em matrizes alimentares se mostra tão
desafiadora quanto as análises de amostras de fluidos biológicos e tecidos; visto que em
ambos estão presentes peptídeos, aminoácidos, lipídeos, carboidratos, vitaminas,
polifenóis, contaminantes e aditivos alimentares29. Na análise de alimentos, devido à
sua complexidade, é comum a separação prévia dos analitos de interesse durante o
preparo de amostras, através de protocolos de extração, sendo a mostra final geralmente
analisada por técnicas cromatográficas. A grande ênfase dada ao preparo de amostras
deve-se aos problemas relacionados ao tempo despendido nesse processo, ao grande
consumo de reagentes e solventes e ao custo gerado30. O desenvolvimento do método
QuEChERS (Quick, Easy, Cheap, Effective, Rugged, Safe) foi um avanço no preparo de
amostras para a detecção de resíduos31. Esse método é utilizado eficientemente para a
limpeza e extração em amostras para a detecção tanto de pesticidas, quanto de outros
contaminantes presentes em alimentos, como micotoxinas e fármacos32, 33.
1.4.1 Técnicas Cromatográficas
A cromatografia gasosa (GC, Gas Chromatography) acoplada à espectrometria
de massas (GC-MS) é uma importante ferramenta na análise de voláteis, principalmente
quando associada aos métodos de clean-up de amostras como a extração em fase sólida,
QuEChERs e uso dos probes para análise em tempo real 32,34. Embora o uso da
cromatografia líquida (LC, Liquid Chromoatography) seja mais comum em estudos de
ciências dos alimentos, sendo a junção LC-MS capaz de permitir a aplicação de
procedimentos genéricos de preparo de amostra, extraindo grande quantidade de
compostos com características físico-químicas distintas, a GC-MS apresenta-se como
uma importante ferramenta na detecção de resíduos químicos em alimentos30.
1.4.2 Curva de Calibração e Adição de Padrão
Em química analítica, uma curva de calibração, também conhecida como curva
padrão, é o método de escolha para determinação de uma substância específica em uma
amostra desconhecida. O procedimento comumente utilizado envolve a comparação da
amostra desconhecida com um conjunto de amostras padrão que possuem concentrações
conhecidas para substância que se quer determinar35. Este tipo de abordagem é um dos
vários tipos que podem ser utilizados para o problema de calibração de instrumentos;
outras abordagens incluem a utilização de um padrão interno ou realizar uma mistura de
18
padrão analítico diretamente à amostra desconhecida, sendo este ultimo método
conhecido como adição de padrão ou spiking 36. Todas estas curvas são comumente
empregadas para análise de compostos químicos em alimentos quando da sua
determinação através de métodos cromatográficos, tais como LC ou GC.
No caso da metodologia de Adição de Padrão, quantidades conhecidas do analito
padrão são adicionadas à amostra de concentração desconhecida e através do aumento
do pico do cromatograma é possível deduzir quanto do analito havia na amostra
originalmente desconhecida. Esta metodologia é especialmente apropriada quando a
amostra em questão possui uma composição complexa, o que pode afetar a resposta
analítica, gerando o efeito de matriz. Pode-se definir como matriz tudo que estiver
presente em uma determinada amostra que for diferente do analito; desta forma, o efeito
de matriz seria definido como uma alteração no sinal analítico causada por qualquer
outro componente na amostra que não seja o analito 35. Este efeito é particularmente
comum no campo da análise de alimentos, visto que estes são considerados amostras
complexas devido a sua composição ser extremamente variada, o que torna o emprego
da curva de Adição de Padrão uma abordagem de destaque para determinação de
substâncias em alimentos.
1.4.3 Espectrometria de Massas
A consolidação da MS como técnica de referência no âmbito da química
analítica (quali e quantitativa) ocorreu nas décadas de 60 e 70. Porém, sua utilização em
alimentos foi, por muito tempo, restrita por impedimentos tecnológicos. O emprego da
MS atualmente é destaque na análise de marcadores químicos em alimentos de forma
targeted e untargeted14. A identificação desses marcadores em metabolômica
geralmente é feita por equipamentos com custo elevado. Entretanto, o ganho maior se
baseia na grande quantidade de amostras que podem ser analisadas por dia ou por
semana, tornando o uso desses equipamentos custo-efetivos16. Para a obtenção de
informações completas sobre as características de cada amostra, diferentes métodos de
ionização foram desenvolvidos ao longo dos anos43, como a ionização por elétrons (EI,
Electron Ionization) e a ionização por spray de elétrons (ESI, Electrospray Ionisation).
As vantagens e desvanatgens das diferentes técnicas utilizadas para determinação de
substâncias em alimentos utilizando a metabolômica estão resumida no Quadro 1.
19
Quadro 1. Comparação entre as diferentes tecnologias utilizadas em metabolômica. (Adaptado de Wishart, 200838).
Tecnologia Vantagens Desvantagens
Cromatografia Gasosa –
Espectrometria de Massas
(GC-MS)
Robustez
Custo mediano
Quantitativo (com calibração)
Necessária pequena quantidade de amostra
Alta sensibilidade
Ampla biblioteca para identificação de metabólitos
Detecta a maioria dos compostos orgânicos e alguns inorgânicos
Excelente reprodutibilidade de separação de compostos
Amostra não recuperável
Necessita demaior preparo de amostra/derivatização
Necessita de separação
Análise longa (20-30 min/amostra)
Não pode ser acoplada à técnicas de imageamento
Difícil identificação de novos compostos (uso de padrões)
Cromatografia Líquida –
Espectrometria de Massas
(LC-MS)
Excelente sensibilidade
Versatilidade
Detecta a maioria dos compostos orgânicos e alguns inorgânicos
Necessária pequena quantidade de amostra
Potencial para detecção de grande parte do metaboloma
Amostra não recuperável
Instrumentação cara
Análise longa (20-30 min/amostra)
Baixa resolução de separação e reprodutibilidade (comparado
a GC)
Menos robusto que a NMR e GC-MS
Limitada biblioteca para identificação de metabólitos
Difícil identificação de novos compostos (uso de padrões ou
alta resolução)
Espectrometria de massas
(MS)
Excelente sensibilidade
Versatilidade
Rapidez
Pode ser usado para imagem (MALDI-Imaging) e alta resolução
(HRMS)
Diversos bancos de dados de metabólitos (p. ex.: HMDB, METLIN,
LIPIDMAPS)
Identificação de compostos
Menor preparo de amostra/injeção direta
Potencial para detecção de grande parte do metaboloma
Seletividade aliada ao experimento MS/MS
Amostra não recuperável
Instrumentação cara
Análise quantitativa depende do equipamento
20
1.4.4. Ionização por Elétrons (EI)
A EI se caracteriza por ser um processo destrutivo, através da fragmentação das
moléculas neutras presentes na amostra pela colisão com elétrons emitidos pela fonte de
ionização. Essa técnica permite a análise de moléculas de baixa e média polaridade com
faixa de massa abrangente39. No processo de ionização, um feixe de elétrons emitido
pela fonte do equipamento colide com moléculas neutras presentes na amostra. A
energia dos elétrons é transferida para as moléculas neutras durante a colisão, podendo
exceder a energia de ionização, o que resulta na ionização por ejeção de elétrons. Além
da ionização das moléculas neutras, durante o processo de transferência de energia
podem ser gerados íons multiplamente carregados, íons rearranjados e fragmentos
moleculares, entre outros, os quais em conjunto auxiliam na identificação e elaboração
da proposta estrutural das moléculas em análise39, conforme representado a seguir:
ABC + 1e- → ABC+. + 2e- (ionização simples) ou
ABC2+. + 3e- (ionização múltipla) ou
AC+ + B. + 2e- ou AC+. + B + 2e- (rearranjo/fragmentação)
Embora a EI tenha sido o primeiro método de ionização desenvolvido para
espectrometria de massas no início do século 20, o uso dessa técnica ainda é relevante
atualmente, principalmente quando combinada como fonte de ionização na GC-MS39,40.
1.4.5 Ionização por Spray de Elétrons (ESI)
O processo de ESI forma moléculas carregadas tanto positiva quanto
negativamente (cátions e ânions, respectivamente), dependendo do tipo de solução na
qual a amostra se encontra. Soluções ácidas favorecem a formação de cátions e soluções
básicas, ânions; em ambos os casos, os íons são formados em solução.
Na Figura 1 encontra-se o processo de ionização por spray de elétrons. Observa-
se que a solução injetada no equipamento é submetida a um spray eletrolítico que oxida
os íons negativos, deixando as gotas produzidas no spray com excesso de íons positivos,
pois neste caso trata-se do modo de análise ESI positivo. Este feixe de íons gerado é
colimado, originando o “Cone de Taylor”. No caso do modo de análise ESI negativo,
ocorre o processo inverso, pois através da redução dos íons positivos da solução, são
geradas gotas com excesso de íons negativos.
Através de uma corrente contrária de nitrogênio, o solvente começa a ser
evaporado e o volume das gotas começa a ser gradativamente reduzido. Ocorre então a
repulsão crescente entre íons de mesma carga, com possível subdivisão das gotas até um
21
limiar no qual ocorre uma explosão coulômbica (coulomb explosion): formação de uma
pluma de cátions isolados em fase gasosa. Desta maneira, estes íons eventualmente
transferidos para a fase gasosa através deste processo brando e eficaz, denominado
dessolvatação, podem ser selecionados e analisados por MS3. O método de ionização
por ESI possui dentre suas vantagens o amplo espectro de massa e de polaridade de
moléculas passíveis de ionização41.
Figura 1. Processo de processo de ionização por spray de elétrons. (adaptado de Cech
& Christie, 200142).
1.4.6 Tandem MS (MS/MS)
O desenvolvimento de novos analisadores e as melhorias nas técnicas e controle
de reações de fragmentação molecular (MSn) permitiram a aplicação da MS altamente
específica para elucidação estrutural de compostos, ampliando ainda mais seu leque na
área de alimentos. Assim, segmentos como segurança alimentar e toxicologia de
alimentos são desafios potencialmente auxiliados por meio desse desenvolvimento
tecnológico.
A técnica de espectrometria de massas em modo tandem, também chamada de
MS/MS ou ainda MS2, utiliza dois ou mais analisadores de massas em sequência, logo
após a fonte de ionização. Os íons precursores são selecionados primeiro por um
analisador de massas e focados na região de colisão, na qual sofrem nova fragmentação,
22
originando produtos iônicos que serão, então, caracterizados por um segundo analisador
de massas43. Um dos equipamentos de MS/MS mais comuns é o do tipo triplo
quadrupolo (QqQ), onde as moléculas são selecionadas pelo primeiro analisador de
massas (quadrupolo, Q1), dissociadas por Dissociação Induzida por Colisão (CID,
Collision-Induced Dissociation) no segundo quadrupolo ou câmera de colisão hexapolar
(q), e por fim os fragmentos são analisados no último quadrupolo (Q2).
A LC e a GC são as técnicas de separação comumente acopladas à MS/MS,
sendo utilizadas para separar os compostos, ionizá-los e introduzi-los no primeiro
analisador de massas44,45. A grande vantagem do uso de MS/MS é o fato de ser uma
técnica confirmatória, pois cada pico/sinal pode ser verificado através de seu espectro
de massas obtidos nos diferentes modos de operação. Portanto, é uma técnica altamente
indicada para a análise e quantificação de moléculas presentes em baixas concentrações
em matrizes complexas, como alimentos46.
1.4.7 Monitoramento de Reações Múltiplas (MRM, Multiple Reaction Monitoring)
O Monitoramento Seletivo de Reações (SRM, Selected Reaction Monitoring) ou
MRM e uma técnica de fragmentação molecular utilizada em MS que permite o
monitoramento de reações específicas por CID. A natureza destas reações dependem
tanto da estrutura molecular quanto da massa de determinado íon47. Como resultado,
melhorias significantes na seletividade analítica podem ser alcançadas utilizando o
método MRM, pois esta ferramenta oferece alta sensibilidade aliada à análises custo-
efetivas para quantificação simultânea de diversos compostos em um único
experimento48.
A implementação de um experimento de MRM convencional envolve o uso de
um espectrômetro de massas com QqQ. O funcionamento detalhado deste tipo de
equipamento envolve um primeiro analisador (Q1) capaz de selecionar íons de uma
determinada razão massa-carga (m/z), correspondente ao íon intacto de um analito alvo;
esses íons são denominados íons precursores. O íon precursor é submetido a uma reação
por CID na célula de colisão (q), que na presença de um gás inerte e pressão apropriada
gera fragmentos iônicos do analito alvo. Os fragmentos com maior intensidade e
especificidade podem ser selecionados para também serem analisados, porém em um
segundo analisador (Q2). Este íons finalmente chegam no detector do equipamento e os
sinais detectados são gravados como um cromatograma iônico para o par de íons
precursor-fragmento49. Desta forma, o sistema QqQ permite uma análise rápida e
23
específica do analito alvo, características que podem ser amplificadas quando se
combina esta técnica com cromatografia, sendo a GC a combinação mais comum para
análise de alimentos46.
1.4.8 Espectrometria de Massas de Alta Resolução
Dada a complexidade das matrizes alimentares, uma resolução de massa limitada
leva à resultados imprecisos. Sistemas de espectrometria de massas com tecnologia
Orbitrap alcançam rotineiramente resolução de até 1.000.000 FWHM com precisão < 1
ppm. Os altos valores de resolução desses equipamentos têm como objetivo a alta
exatidão na determinação de moléculas complexas. Além da alta resolução e exatidão, a
técnica diferencia-se por fornecer informações que atuam na elucidação estrutural de
moléculas desconhecidas, sendo possível atribuir fórmulas moleculares (CcHhNnOoSs)
inequivocamente para medidas de baixa massa molar (< 450 Da) utilizando o princípio
de massas exatas e defeitos de massas37,50.
1.5 Produtos Alimentícios
1.5.1 Leite
O leite é um alimento extremamente complexo. Parte de seus componentes é
produzida pelas células secretoras da glândula mamária dos animais mamíferos e outra
porção é oriunda da corrente sanguínea dos mesmos. O fluido secretado pelas fêmeas
dos mamíferos, cuja principal função é fornecer os requerimentos nutricionais de seus
filhotes, deve suprir as suas necessidades energéticas (lipídios e carboidratos), proteicas
(aminoácidos), vitamínicas e de minerais. A ordenha ininterrupta de bovinos saudáveis
apresenta em média 3,7% de gordura, 3,4% de proteína, 4,8% de lactose, 0,7% de
cinzas e 12,7% de sólidos totais51. Segundo o USDA (United States Department of
Agriculture), a produção brasileira de leite terá um crescimento de 1,8% para o ano de
2018, atingindo 23,98 milhões de toneladas de leite, sendo que um terço dessa produção
é destinada para o mercado interno52.
Os lipídios do leite, comumente chamados de gordura, formam uma emulsão
com a fração aquosa do leite. Os triglicerídeos representam a maior fração dos lipídios
presentes no leite de bovinos, aproximadamente 98%. Diglicerídeos, monoglicerídeos,
ácidos graxos, fosfolipídios e colesterol também estão presentes em menor quantidade.
A lactose, um dissacarídeo formado por uma molécula de galactose e uma de glicose, é
o principal carboidrato do leite. As proteínas do leite estão distribuídas em duas frações
24
distintas: caseínas e proteínas do soro. A caseína corresponde a 80% do total proteico no
leite bovino, e pode ser subdividida em quatro frações principais, s1, s2, e -caseína, que
se agrupam na forma de micelas. As proteínas do soro apresentam formato globular,
sendo que as principais encontradas no leite bovino são: -lactoglobulina, -
lactoalbumina, albumina do soro sanguíneo e imunoglobulinas.
O leite bovino também possui uma quantidade significativa de minerais, dos
quais se destacam o cálcio, o fosfato e o citrato, além de vitaminas dos complexos A e
B53. Também apresenta em sua constituição diversas enzimas naturais. Entre elas
destacam-se a fosfatase alcalina e a lactoperoxidase por serem marcadores de um
adequado processamento térmico. O ponto de inativação da fosfatase alcalina (binômio
tempo-temperatura) é similar ao requerido para a destruição dos microorganismos
patogênicos mais resistentes ao tratamento, sendo assim, sua inativação garante um
produto inócuo para o consumidor. A lactoperoxidase é uma das enzimas mais
termorresistentes encontradas no leite e sua inativação é usada como marcador de
utilização de temperaturas mais elevadas em processos de pasteurização53,54.
Designado para a completa nutrição de bezerros em fase de crescimento, o leite
bovino também é um meio adequado para o crescimento acelerado de ampla variedade
de microorganismos. A abundância de carboidratos, proteínas e gorduras combinados
com o pH próximo da neutralidade favorecem o desenvolvimento da flora microbiana55.
Diversos fatores afetam a qualidade final do leite. Os fatores intrínsecos incluem a raça
do animal, o período de lactação, o número de parições, e a dieta oferecida à vaca. Os
fatores extrínsecos, por sua vez, são aqueles capazes de afetar a qualidade do produto
após sua produção, como por exemplo, o manejo e a higiene da ordenha, a velocidade e
a temperatura de resfriamento, o transporte e o armazenamento do leite antes do seu
processamento.
As raças mais comumente utilizadas para a produção de leite no mundo são:
Holandesa preta e branca, Holandesa marrom e branca, Ayrshire, Guernsey e Jersey56.
Esses animais são da espécie Bos taurus de alta produção, entretanto, por terem sido
selecionados na Europa, estão totalmente adaptados ao clima frio da região57. No Brasil,
devido ao clima quente estes animais sofrem um stress térmico extremamente
acentuado58. Segundo West, Mullinix & Bernard59, os aumentos da temperatura
ambiente, da umidade relativa do ar e da temperatura do animal estão relacionados à
diminuição do consumo de matéria seca pelos animais e consequente diminuição da
produção de leite. Visando amenizar o efeito da temperatura no plantel produtor de leite
25
é muito comum a utilização de raças adaptadas ao clima quente. No Brasil, utiliza-se o
gado Zebu (Bos indicus) isolado, principalmente a raça Gir, ou o cruzamento com a raça
Holandesa, resultando no Girolando60.
A lactação é um processo totalmente dependente da produção hormonal do
animal. Sendo assim, os animais sexualmente maduros são os aptos à produção de leite.
Khan & Shook61 relatam que animais mais velhos tendem a apresentar uma maior
produção em todas as lactações, contudo este efeito tende a diminuir com o avanço das
lactações. A alimentação do animal também interfere na produção de leite. A baixa
ingestão de matéria seca e a baixa ingestão energética diminui a produção de leite62. A
forma de apresentar a ração para os animais também altera a produção de leite63. Isto se
deve ao fato do animal necessitar ingerir uma dieta balanceada. Contudo, alimentos
energéticos, ricos em gordura (silagem), são muito mais palatáveis que aqueles ricos em
fibras (capim). Quando estes são apresentados separadamente, os animais aumentam a
ingestão de silagem e diminuem a ingestão de fibras, tornando suas dietas
desbalanceadas. Sistemas que misturam os ingredientes da dieta antes de apresentá-la no
cocho, conhecidas como Total Mixed Ration (TMR), e que, consequentemente,
dificultam a separação de seus componentes pelos animais são os mais adequados para
animais de alta produção64.
Com relação a qualidade do leite comercializado no país melhorar a qualidade e
a segurança do leite ao longo de todo o sistema produtivo é a proposta de um recente
edital lançado pela Secretaria de Desenvolvimento Agropecuário e Cooperativismo do
Ministério da Agricultura, Pecuária e Abastecimento (SDC/Mapa). Esta tem como
objetivo principal assessorar e capacitar os produtores rurais na estruturação das
unidades de produção, especialmente na implementação de boas práticas
agropecuárias65. Dentro das boas práticas agropecuárias estão incluídos o controle
permanente da qualidade da água da propriedade rural, o registro e o acompanhamento
de dados e dos procedimentos realizados na propriedade, o adequado armazenamento e
transporte de matérias-primas, insumos e alimentos, a garantia da rastreabilidade dos
animais e dos produtos originados na propriedade, a higiene e os procedimentos
adequados de ordenha e pós-ordenha, a higiene, a limpeza, a manutenção e o
dimensionamento adequados dos equipamentos de ordenha e de refrigeração do leite, a
identificação, o registro e a segregação de animais sob tratamento veterinário ou
pastagens sob uso de agrotóxicos, o manejo adequado de bezerras na propriedade rural,
entre outros itens65.
26
Desta forma nota-se que o leite é um alimento que requer uma série de cuidados
durante o seu processamento, sendo um dos alimentos amplamente comercializados
tanto no Brasil quanto no mundo. Devido aos avanços da tecnologia o custo de sua
produção tem aumentado, o que o torna alvo de possíveis adulterações. A autenticidade
de alimentos é um aspecto importante para os consumidores, pois além de ser sinônimo
de qualidade, envolve a confiabilidade no que está sendo comprado. Alguns atributos
estão diretamente ligados à autenticidade de alimentos, como por exemplo: genética,
origem geográfica, tratamentos de colheita e pós-colheita, condições de processamento
e outros ingredientes que podem ser funcionais para a qualidade1. Atualmente, os
consumidores estão cada vez mais exigentes quanto às informações, segurança da
origem e conteúdo dos seus alimentos. Além disso, os fabricantes de alimentos buscam
fornecer e confirmar a autenticidade e denominação de origem dos componentes de seus
produtos alimentícios, uma vez que esta é uma maneira de agregar valor aos produtos
finais, além de atestar sua qualidade.
Determinar a autenticidade de alimentos pode impedir a falsa descrição, a
substituição por ingredientes mais baratos, e a adulteração, bem como a rotulagem de
origem incorreta. As agências reguladoras estão desenvolvendo normas legais e
políticas para determinar formas de identificar e marcar os alimentos utilizando
terminologia adequada. Por exemplo, regulamentações na União Européia66,67 fornecem
rotulagem de Denominação de Origem Protegida (DOP), Indicação Geográfica
Protegida (IGP) e Especialidade Tradicional Garantida (ETG), visando garantir a
autenticidade de produto regionais e alimentos especiais. Essas leis, impostas na União
Européia garantem que apenas os produtos genuinamente originários dessa região
podem ser vendidos como tal, eliminando a concorrência desleal e produtos enganosos
que podem ser de qualidade inferior ou feito de componentes diferentes.
No caso da certificação do leite no Brasil, com o incentivo do novo edital de
boas práticas agropecuárias proposto pela SDC/Mapa65 já existem pecuaristas que
receberam certificação de qualidade no estado de Minas Gerais, e a tendência é que esta
informação se multiplique com o passar do tempo. Desta forma, nota-se a importância
da garantia da qualidade para alimentos como o leite. Outro ponto importante seria o
caso de adulterações, que no caso do leite visam sempre extender a sua vida de
prateleira, controlando o desenvolvimento microbiológico e reduzindo a oxidação de
componentes. Os adulterantes mais comumente utilizados para este fim são o peróxido
de hidrogênio, formoldeído, hipoclorito de sódio e hidróxido de sódio68,69. Neste ponto,
27
a MS apresenta-se mais uma vez como uma grande ferramenta de análise na
identificação de possíveis adulterações de produtos alimentícios70,71, pois é uma técnica
bastante sensível e versátil, que deve ser considerada para utilização com tais fins.
1.5.2 Carne
O Brasil ocupa um dos primeiros lugares em produção agrícola e pecuária no
mundo. A pecuária é uma atividade econômica desenvolvida em áreas rurais que
consiste na criação de animais com o objetivo de comercializá-los, suprindo assim as
necessidades tanto da família como do criador. Fundamentalmente, a atividade em foco
é ligada à criação de gado (bovinos), embora seja considerada também a produção de
suínos, aves, equinos, ovinos e bufalinos. Esse ramo tem como responsabilidade
principal disponibilizar para o mercado alimentos como carne, leite e ovos, produtos
base da dieta humana. Além da carne, no caso dos bovinos são extraídas outras
matérias-primas como o couro (produção de calçados), a pele (vestuário) e os ossos
(produção de botões).
A pecuária exerce uma grande relevância nas exportações brasileiras, além de
abastecer o mercado interno. Cerca de 20% da área do país (174 milhões de hectares)
está atualmente ocupada por pastagens, sendo que a maior parte do rebanho de 215
milhões de cabeças é criada a pasto (estima-se que somente 3% do rebanho esteja em
sistema intensivo)72. A década de 2000 foi marcada pela consolidação do Brasil como
potência na produção e exportação de carne bovina, sendo que o Brasil assumiu a
primeira colocação dentre os exportadores em 200473.
Entre as diversas raças bovinas existentes no Brasil a comumente utilizada é a
raça nelore; uma das raças zebuínas. 80% do gado brasileiro é zebuíno (proveniente da
Índia), os outros 20% são de raças européias. O nelore provou ser o melhor gado para o
Brasil graças a sua adaptabilidade ao clima tropical do país. As raças europeias se
adaptam melhor à região sul e são utilizadas para o que se chama de “cruzamento
industrial”, isto é, cruzamento de gado zebu com gado europeu. Com relação à
segurança da carne comercializada atualmente, os consumidores não estão mais
interessados apenas em aspectos sensoriais, como por exemplo sabor, odor e textura.
Existe agora uma preocupação com relação aos constituintes dos alimentos, visando
principalmente à manutenção da saúde e qualidade de vida do consumidor. Devido a
isso, a segurança alimentar é agora uma preocupação primordial na indústria de
alimentos, e em particular na indústria de carne.
28
A embalagens de alimentos é uma forma importante para armazenar alimentos
em diferentes temperaturas, prolongando a vida de prateleira do produto e protegendo
os alimentos de agentes naturais (p. ex. o ar) que podem reduzir ou alterar a sua
qualidade. Dentre diversos materiais, os plásticos têm surgido como uma solução
prática, segura e confortável para embalagens de alimentos. Existem diferentes tipos de
plástico, cada um com propriedades únicas e diferentes aplicações no setor de alimentos
como, por exemplo, o policarbonato de alta densidade e o polietileno de baixa
densidade, copolímeros de estireno, polipropileno, entre outros. Estes plásticos são
fabricados a partir de vários polímeros e os aditivos são utilizados para alterar sua
elasticidade, flexibilidade, cor, resistência e durabilidade. Tanto o plástico quanto os
seus aditivos podem migrar a partir da embalagem para a comida ou bebida
acondicionada ao longo do tempo, como resultado de um aumento na temperatura ou de
algum choque mecânico74. A presença de componentes de plástico ou de aditivos nos
alimentos, se não for devidamente controlada, pode afetar as propriedades
organolépticas dos alimentos e até mesmo produzir efeitos de desregulação endócrina75,
se os níveis excedem os valores legais ou toxicológicos. Muitos plastificantes e aditivos
são considerados desreguladores endócrinos, e por isso podem afetar o sistema
reprodutivo ou até mesmo agir como agentes cancerígenos. Alguns destes produtos
químicos são os ésteres de ftalato, alquilfenóis, bisfenóis, entre outros74.
A União Europeia regulamenta que materiais em contato direto com alimentos
não devem ser capazes de ceder os seus constituintes aos alimentos em quantidades que
possam colocar em risco a saúde humana ou provocar uma alteração inaceitável da
composição, ou deterioração das características organolépticas do alimento embalado76.
Os materiais plásticos são especificamente regulamentados por uma comissão que
estabelece uma lista positiva de substâncias, incluindo todos os monômeros, outras
substâncias e aditivos que podem ser utilizados para a fabricação de embalagens
plásticas, bem como as restrições para os níveis de migração desses produtos químicos
em alimentos77. O uso de substâncias não incluídas na lista é proibido78. No Brasil
também existe este rígido controle pois recentemente a Agência Nacional de Vigilância
Sanitária (ANVISA) atualizou a norma brasileira que trata de embalagens plásticas,
seguindo os mesmos requisitos apontados anteriormente, com o intuito de aumentar a
segurança dos alimentos embalados no país79.
A carne bovina é amplamente comercializada e consumida no Brasil e nota-se
que a maioria dos cortes apresentam-se em embalagens plásticas. Com o intuito de
29
verificar a segurança destas embalagens e se há passagem de algum de seus
componentes para a carne a MS apresenta-se como uma grande ferramenta de análise,
que pode oferecer resultados rápidos e eficientes, sendo uma técnica bastante versátil
para análise de alimentos22,32,70,80.
1.5.3 Cachaça
A cachaça é uma bebida típica brasileira, sendo esta a denominação exclusiva de
destilados de cana de açúcar produzidos no Brasil. As suas principais características são
apresentar gradação alcoólica de 38% – 48% a uma temperatura de 20 ºC e ser obtida da
destilação do mosto de cana de açúcar fermentado81. O processo de fabricação da
cachaça não é padronizado em vários aspectos. O primeiro seria a matéria-prima
utilizada, neste caso a cana de açúcar, pois existem diversos tipos diferentes porém
similares em sua composição82. Além disso, grãos como milho ou arroz também podem
ser incluídos no mosto com o objetivo de fornecer nutrientes para melhorar o
desenvolvimento das cepas responsáveis pela fermentação83. Finalmente, o equipamento
utilizado pode ser proveniente de diversos tipos de materiais, pois a destilação pode ser
realizada, por exemplo, em colunas de aço inox (no caso de processos industriais) e em
alambiques de cobre (no caso da produçao artesanal)82.
O processo de maturação em barris de madeira é semelhante ao aplicado na
produção de vinho, onde barris de carvalho, bálsamo, jequitibá, jatobá ou amburana
podem ser empregados. Este último processo é opcional e é capaz de fornecer aromas,
sabores e coloração da madeira para a cachaça84. Entretanto, com relação aos aspectos
organolépticos, a cachaça deve preencher alguns parâmetros químicos que asseguram
que o consumo moderado do produto não seja capaz de acarretar riscos para a saúde.
Contaminantes como metanol, sec-butanol, n-butanol, cobre, etil carbamato, assim
como o ácido acético, um composto de off-flavor responsável pela acidez característica
da cachaça, são espécies chave diretamente relacionadas com o comprometimento da
qualidade do destilado final82,85,86.
De acordo com uma avaliação da IARC (International Agency for Research on
Cancer) de 2007, o etil carbamato é considerado carcinogênico para animais de
laboratório e por isso foi listado como uma substância potencialmente carcinogênica
para humanos, pertencendo ao Grupo 2A da Classificação de Substâncias
Carcinogênicas87,88. Este composto é um etil éster do ácido carbâmico que é formado
naturalmente em processos de fermentação, podendo ser derivado de diferentes
30
precursores, como por exemplo ácido hidrociânico, uréia, citrulina, e N-carbamil através
de reação com etanol88. Devido a esta característica, é fácil encontrar este composto em
diversos tipos de comidas e bebidas como destilados, vinho, cerveja, pão, shoyu e
iogurte89. O consumo de etil carbamato apenas de fontes alimentícias é insignificante.
Entretanto, incluindo o consumo de bebidas alcoólicas regularmente, a exposição a este
composto aumenta. Atualmente, a cachaça figura como a terceira bebida destilada mais
consumida no mundo, e no Brasil é a segunda bebida alcoólica mais consumida, depois
da cerveja90. Dado o seu amplo consumo, devem ser tomadas medidas em relação à
redução da concentração de etil carbamato nas bebidas alcoólicas. O Canadá, através do
Health and Welfare Department em 1985, foi o primeiro país a determinar os limites de
concentração de etil carbamato em vinhos, destilados, destilados de frutas e licores. Por
isso, tornou-se referência para os Estados Unidos e União Européia quanto à legislação
sobre o assunto91. Em 1990, o FDA publicou uma nota limitando o teor de etil
carbamato nos uísques americanos para 125 µg L-1 92. Segundo o Ministério da
Agricultura, Pecuária e Abastecimento, o limite para esse contaminante em cachaças no
Braisl é 150 µg L-1 81. A importância do controle dos níveis de etil carbamato, portanto,
deve ser entendida como uma questão não apenas sobre aspectos relacionados à saúde e
segurança, mas também econômicos, pois qualquer resultado fora de especificação pode
representar uma barreira à exportação de cachaça para o mercado internacional.
Muitos métodos diferentes utilizando MS foram desenvolvidos nos últimos anos,
sendo capazes de avaliar uma grande variedade de parâmetros de qualidade da
cachaça93,94,95, assim como muitos protocolos para análise e extração do etil
carbamato88. O uso da GC-MS com quadrupolo único é a técnica amplamente utilizada
para análise deste contaminante, de forma que esta é capaz de promover com grande
eficiência tanto a identificação quanto a quantificação de amostras de alimentos e
bebidas alcoólicas88. Entretanto, existe um procedimento comum de adição de açúcar à
cachaça com o intuito de reduzir o sabor alcoólico desta bebida, padronizando o seu
sabor, melhorando a qualidade sensorial final. No caso da cachaça, a legislação
brasileira permite a adição de até 6 g L-1 de sacarose, como procedimento de
padronização do sabor. Não obstante, se no rótulo estiver descrito “adoçado”, o produto
final pode conter até 30 g L-1 de sacarose em sua composição96. Como a GC-MS é a
técnica de escolha para o controle de qualidade da cachaça, um alto conteúdo de
sacarose pode facilmente contaminar o percurso interno do fluxo do GC, acarretando
numa maior frequência de manutenções de equipamento, além de comprometer a
31
precisão dos resultados. Neste caso, o desenvolvimento de uma nova metodologia capaz
de lidar com as quantidades excessivas de sacarose presentes na cachaça, mantendo a
precisão e exatidão da análise torna-se necessário.
Relacionado com o preparo de amostra, carbamatos usualmente estão presentes
em concentrações muito baixas e em matrizes complexas, como o caso das amostras de
cachaça. Por causa disto, sua análise não pode ser realizada sem alguns tratamentos
preliminares de amostras. Um procedimento de preparação de amostras deve fornecer a
concentração de analitos e também a sua limpeza, melhorando assim a determinação do
analito de interesse. Recentemente, a busca por métodos miniaturizados que são
eficientes e não utilizam grandes quantidades de reagentes e solventes faz com que a
melhoria dos métodos de extração esteja em foco. Assim, diferentes procedimentos de
microextração foram desenvolvidos como alternativas, como a metodologia
QuEChERS, que tem sido amplamente utilizada no pré-tratamento de amostras
complexas. Esta técnica baseia-se num método de dois passos onde é primeiro realizado
a extração, baseada no particionamento que ocorre através do fenômeno de salting-out,
responsável pelo equilíbrio entre as camadas aquosa e orgânica. O segundo passo é uma
extração dispersiva em fase sólida, que envolve a limpeza da amostra usando
combinações de diferentes tipos de sais sorventes ou aminas primárias-secundárias com
o objetivo de remover quaiquer substâncias interferentes 97,98.
Finalmente, nesta tese apresentamos uma nova metodologia para aplicação de
QuEChERS, baseada unicamente na extração salting-out, como uma maneira de
eliminar resíduos de açúcar e água de amostras de cachaça (artesanal e comercial), o
que foi corroborado através de experimentos utilizando LC, sem comprometimento da
identificação e quantificação do etil carbamato. Adicionalmente, realizamos a
comparação desta nova metodologia com a atualmente empregada na análise do etil
carbamato.
32
2. OBJETIVOS
O estudo dos diferentes produtos alimentícios apresentados (leite, carne e
cachaça) abrange grande parte de processos presentes em atividades de grande
importância no país. Desta forma, os objetivos principais deste trabalhao foram:
- Propor novas metodologias de análise de produtos alimentícios utilizando a plataforma
metabolômica em conjunto com novas técnicas de Espectrometria de Massas com
ionização por spray de elétrons (ESI-MS) e Cromatografia a Gás acoplada à
Espectrometria de Massas (GC-MS);
- Minimizar ou eliminar o preparo de amostras nas análises destes produtos, diminuindo
custos, tempo e principalmente o consumo de solventes orgânicos, adequando-se aos
parâmetros de química verde.
2.1 Objetivos Específicos
Desenvolver novas metodologias analíticas para:
- Verificar parâmetros de qualidade do leite através do estudo da interação entre
adulterantes (formol, hidróxido de sódio, peróxido de hidrogênio e hipoclorito de sódio)
com os componentes nutricionais do leite;
- Verificar o fenômeno de migração de componentes advindos da embalagem de carne
vermelha embalada a vácuo;
- Identificar e quantificar o etil carbamato em amostras de cachaças (comerciais e
artesanais) eliminando a interferência da sacarose na análise.
33
3. METODOLOGIA
As metodologias específicas para cada uma das frentes estudadas nesta tese
serão abordadas em detalhes nos artigos apresentados na seção 4. Resultados.
3.1 Infraestrutura utilizada no projeto
O projeto foi desenvolvido no Laboratório Innovare de Biomarcadores, inserido
na Faculdade de Ciências Médicas (FCM) da Universidade Estadual de Campinas
(Unicamp). A coordenação do Laboratório e do projeto está a cargo do professor Dr.
Rodrigo Ramos Catharino, que possui ampla experiência em Análise de Alimentos. O
grupo tem desenvolvido pesquisas de alta qualidade, com cunho relevante na busca de
aplicações inovadoras em áreas como ciência de alimentos e ciências da vida. Os
equipamentos utilizados no desenvolvimento desse projeto de pesquisa foram:
- Cromatógrafo a Gás Agilent GC-MS 7890/7000, com fonte de ionização EI, e
analisador triplo quadrupolo (QqQ). Equipamento equipado com injetor automático, o
que faciltou o desenvolvimento da metodologia .
- Espectrômetro de Massas ESI-LTQ-XL Orbitrap Discovery, Thermo Scientific: com
fonte de ionização ESI, analisadores quadrupolo e armadilha iônica linear (linear ion
trap - LTQ) associado a um analisador Orbitrap de alta resolução (30.000 FWHM) e
precisão < 5 ppm, o que faciltou na identificação de compostos por meio do uso de
banco de dados.
3.2 Análise Estatística de Dados
O emprego de análises multivariadas como a Análise de Componente Principal
(PCA, Principal Component Analysis), a Análise Discriminante por Mínimos
Quadrados Parciais (PLS-DA, Partial Least-Squares Discriminant Analysis) ou de suas
variantes estão comumente presentes para a classificação de amostras29. A análise
multivariada foi realizada utilizando o sistema web MetaboAnalyst 3.099. Com o auxílio
da análise de componentes pretende-se observar as principais diferenças entre as
amostras (antes e após tratamento) visando a descoberta marcadores relacionados aos
contaminantesde alimentos.
3.3 Propostas Estruturais
A identificação dos marcadores químicos foi realizada através da comparação
entre as razões m/z em alta resolução e consulta de bancos de dados (NIST e METLIN).
34
4. RESULTADOS
A seguir estão apresentados os trabalhos desenvolvidos durante este doutorado,
demonstrando a execução e discussões de cada umas das frentes anteriormente
apresentadas.
4.3 ARTIGO I
Evaluating the Effects of the Adulterants in Milk using Direct-Infusion High-
Resolution Mass Spectrometry100
Tatiane Melina Guerreiro1, Diogo Noin de Oliveira1, Carlos Fernando Odir
Rodrigues Melo1, Estela de Oliveira Lima1, Marta Ribeiro da Silva1 and Rodrigo Ramos
Catharino1*
1 Innovare Biomarkers Laboratory, School of Pharmaceutical Sciences, University of
Campinas – UNICAMP, Campinas, SP, Brazil.
*Correspondence: Rodrigo Ramos Catharino ([email protected])
Abstract
Milk is an extremely complex food, capable of providing essential nutrients as well as
being an important source of energy, and high-quality proteins and fats. Due to
advances in technology, and to meet the increasing demand, production costs have
increased, turning milk into a target of adulterations. Routine methods usually applied
to certify the quality of the milk are restricted to microbiological tests, and assays that
attest the nutritional composition within the expected values. However, potentially
harmful byproducts generated by adulterating substances in general are not detected
through these methodologies. In this contribution, we simulated the adulteration of
freshly produced milk samples with four adulterants whose use already had reported for
extended shelf life: formaldehyde, hydrogen peroxide, sodium hydroxide, and sodium
hypochlorite. These samples were submitted to direct-infusion high-resolution mass
spectrometry analysis and multivariate statistical analysis. This approach allows the
characterization of a series of molecules modified by the adulterants, whatdemonstrates
how these species affect the nutritious characteristics of this product.
Keywords: Milk. Adulteration. Oxidation. Quality. Adulterants. Shelf life.
35
Introduction
Globally, there are about 7 billion consumers of milk and dairy products, most of
them concentrated in developing countries (FAO, 2016). Within this market, Brazil
figures as the world's fifth largest dairy producer, in a ranking that brings India as the
first, accounting for 18% of global production, followed by the United States, China and
Pakistan (IFCN, 2014). According to the United States Department of Agriculture
(USDA), Brazilian milk production is expected to grow 1.8% in 2018, reaching 23.98
million tons, with a third of this production destined only to the inner market (USDA,
2017).
Milk is an extremely complex food, capable of providing essential nutrients as
well as being an important source of energy, and highquality proteins and fats. Cow's
milk is composed on average of 87% water, 4 to 5% lactose, 3% protein, and 3 to 4%
fat (Pereira, 2014). Although it is a food with high nutritional value, it has a short shelf
life and therefore requires specific processing steps such as pasteurization to work
around this problem. Pasteurization is a process that involves the heating followed by
rapid cooling of the milk, so that the levels of any potential pathogen are reduced,
thereby reducing health risks and resulting in increased shelf life (Kapaj & Deci, 2017).
In addition, regarding the improvement of milk quality and safety, a government
program was created in Brazil to advise and train rural producers in the structuring of
their production units, implementing good agricultural practices. This program
encompasses sanitary control during all stages of milk processing, i.e. from cow rearing,
milking, to storage and proper transport of milk (MAPA, 2016). In this way, it is noted
that milk is a food that requires care in its processing chain.
Due to advances in technology, and to meet the increasing demand, production
costs have increased, turning milk into a target of adulterations (Hemme, Uddin, &
Ndambi, 2014). This activity may generate not only economic losses, but also increased
risk to consumers' health, commonly digestive problems (Tay, Fang, Chia, & Li, 2013).
Milk adulteration involves the dilution and/or addition of lower-quality products at low
concentrations and, in some cases, harmful products with the aim of masking inferior
quality, increasing the volume or even replacing a substance naturally present in milk to
increase the yield of the final product (Nascimento, Santos, Pereira-Filho, & Rocha,
2017). One of the simplest examples of milk adulteration is the addition of water to
increase the final volume. Nonetheless, recent and more sophisticated frauds have been
reported in both media and in scientific documents, and are often more difficult to
36
detect (Nascimento et al., 2017). Some examples of recent adulterations would be the
addition of urea and melamine to increase nitrogen content (Jha, Jaiswal, Borah,
Gautam, & Srivastava, 2015; Lu et al., 2017), the addition of formaldehyde, hydrogen
peroxide, hypochlorite, dichromate, and salicylic acid in order to increase shelf life
(Jeong et al., 2015), and the addition of vegetable oils and surfactants to alter the fat
content (Rani, Sharma, Arora, Lal, & Kumar, 2015).
Regarding these chemical adulterants, regulatory authorities such as the Food
and Drug Administration (FDA) in the United States and the World Health
Organization (WHO) have established maximum residue limits (MRLs) and tolerable
daily intakes (TDI) to maintain food safety and health of consumers (Nascimento et al.,
2017). In this way, certifying and guaranteeing aspects of milk quality is important for
the population health, in addition to also increase the reliability of the products.
Furthermore, consumers are increasingly demanding with respect to information on the
safety, origin and composition of foods. In this way, determining food authenticity is
essential to prevent substitution by cheaper, often harmful, ingredients and,
consequently, adulteration.
Routine methods usually applied to ensure the quality of the milk are restricted
to microbiological tests, and assays that attest the nutritional composition within the
expected values. However, the effects of adulterating substances in general are not
detected through these methodologies, and methods that assess the consequences of
adulterations are scarce. An example of this fact would be the addition of hydrogen
peroxide with the objective of activating the enzyme lactoperoxidase, naturally present
in milk, increasing its antimicrobial activity, which increases the shelf life of
pasteurized milk. The identification methods commonly used in this case are specific
sensors for identification of hydrogen peroxide, but these are not able to evaluate the
effects caused by the adulterant-milk components interaction (Reanpang,
Themsirimongkon, Saipanya, Chailapakul, & Jakmunee, 2015). On the other hand, our
study proposes precisely the identification of the chemical changes that can occur when
the adulterant acts in milk nutrients and not only the presence of adulterant itself.
In this context, strategies have been applied and developed in recent years for
the identification and quantification of adulterants in milk (Nascimento et al., 2017), but
there still remains a need for methods that provide complementary results, where actual
species can be determined and potentially monitored as quality control markers. Along
these lines, mass spectrometry (MS) presents itself as a great analytical tool to identify
37
adulterations in food products (De Oliveira & Catharino, 2015; Guerreiro, de Oliveira,
Ferreira, & Catharino, 2014; Riccio et al., 2011), as it is a very versatile and fast
technique, able to provide results with great accuracy.
MS is often coupled with separation approaches, such as liquid or gas
chromatography, in the identification and quantification of adulterants (Verma &
Ambatipudi, 2016). The use of these techniques, however, often implies specific sample
preparation processes such as extraction and/or derivatization of compounds, which
usually impair the direct analysis of a complex matrix, as in the case of milk. This fact
prevent a performance of untarget high throughput analysis, which could make it more
dynamic to identify the possible components of milk that have been interacted with the
adulterants. High-resolution mass spectrometry (HRMS) is a technique that combines
both selectivity and sensitivity, and could be used to identify a wide range of
compounds in a variety of matrices. In addition, when combined with direct infusion
(DI) of samples, it shows great potential to provide reliable results in just one minute
(Guerreiro et al., 2018; Ibáñez, Simó, García-Cañas, Acunha, & Cifuentes, 2015; Melo
et al., 2017; Vivian, Aoyagui, de Oliveira, & Catharino, 2016).
In this preliminary contribution, we simulated the adulteration of freshly
produced milk samples with four adulterants that already had reported use in Brazil for
extended shelf life: formaldehyde, hydrogen peroxide, sodium hydroxide, and sodium
hypochlorite. These samples were submitted to DI-HRMS and multivariate statistical
analysis in comparison with the unadulterated product, rendering a series of oxidized
molecules that demonstrate how these species affect the nutritious characteristics of the
product. The results are promising and demonstrated the versatility of DI-HRMS in
providing the characterization of the main altered species in milk and, in the future, can
be of great help in the development of a methodology based on direct infusion samples.
Materials and Methods
Sample Preparation
Samples of milk were obtained directly from farmers in the region of Minas
Gerais, Brazil. The milk were from four different producers and a blend was made using
equal amounts of milk from each producer (1:1:1:1), with the intention that the control
samples were as similar to the real conditions. An aliquot of 10 μL of fresh milk
blended sample was diluted in 990 μL of a solution of Methanol:Mili-Q Water (50:50).
38
This mixture was vortexed for one minute and then filtered on PVDC membranes of
0.22 μm. This solution was split into two, each one used in a different mode of analysis,
positive or negative ion mode. For positive ion mode analysis, 1 μL of formic acid (final
concentration = 0.2% v/v) was added to one of these fractions of 500 μL and, for the
negative ion mode analysis, 1 μL of ammonium hydroxide (final concentration = 0.2%
v/v) was added to the other fraction. Methanol, ammonium hydroxide and formic acid
were purchased from J. T. Baker (Xalostoc, Mexico) and used with no further
purification. Deionized water was obtained from a Milli-Q system (Millipore, USA).
Adulterations with formaldehyde (15,512, Sigma-Aldrich, Saint Louis, MO),
hydrogen peroxide (H3410, Sigma-Aldrich, Saint Louis, MO), sodium hydroxide
(1.09137, Sigma-Aldrich, Saint Louis, MO) and sodium hypochlorite (425,044, Sigma-
Aldrich, Saint Louis, MO) were performed at the concentrations of 1, 2.5, 5 and 10%
v/v for each of the four adulterants in the fresh milk. The other steps of sample
preparation for DI-HRMS analysis were the same as those used for the analysis of the
milk profile without adulteration (control), described above. All samples were prepared
in triplicates, for the control raw milk and for each different concentration of
adulterants, composing a total of 51 samples: 48 adulterated (12 samples per group),
and 3 controls.
High Resolution Mass Spectrometry (HRMS)
All analyses were performed on the ESI-LTQ-XL Orbitrap Discovery (Thermo
Scientific, San Jose, CA, USA) with a nominal resolution of 30,000 (FWHM).
Acquisitions were carried out in the mass range of 100 to 1000 m/z in both, positive and
negative ion modes. The parameters used were: flow rate of 10 μL min−1, capillary
temperature of 280 °C, 5 kV as spray voltage and sheath gas in 10 arbitrary units. All
acquisitions were obtained in quintuplicates.
Statistical analysis and biomarker identification
The method of choice to evaluate the differences between the groups was Partial
least squares discriminant analysis (PLS-DA) with the variable importance in projection
(VIP) score. PLS-DA is a supervised method that uses multivariate regression
techniques to extract features from each group and show the existence of either
differences or similarities between the analyzed samples. The selection of features that
were characteristic for each sample was carried out considering the impact that each
feature had in the analysis through VIP scores, which consists of the weighted average
39
of the squares of the PLS loadings considering the amount of explained variance on the
two dimension used in the model. As a cutoff threshold, only the features with a VIP
score greater than 3 were analyzed. All statistical analyses were performed using the
online platform MetaboAnalyst 3.0 (Xia, Sinelnikov, Han, & Wishart, 2015). For the
structural elucidation of the markers, mass accuracy was the main parameter, by
comparing the mass values obtained experimentally and those available in online
databases, such as METLIN (Scripps Center for Metabolomics, La Jolla, CA, USA), in
order to guide the choice of potential markers for adulteration in milk, a compound was
elucidated when presented an identification error value of less than 2 ppm.
3. Results and Discussion
The analysis of the score plots generated by PLS-DA allows observing that it
was possible to separate the groups corresponding to the control sample and the
adulterated samples across all adulterants concentrations 1, 2.5, 5 and 10% v/v. This
preliminary screening of samples against the controls group was relevant because it
demonstrates the sensitivity of the technique to identify adulterated milk
(supplementary material). The applied approach, which used VIP score analysis from
each PLS-DA score plot made also possible to verify that the most important features
were the same among all 4 adulterant concentrations. For this reason, the lowest
concentration of adulterant was chosen for a complete chemical analyses and structural
identification of components, i.e. 1% v/v (Figure 1). In Figures 2 and 3 it is possible to
analyze the spectra of the adulterated samples in comparison to the spectral profile of
the control raw milk, which shows that there were evident changes in the mass spectrum
profile when one of the adulterants is used.
To statistically confirm the difference among the mass spectrum samples the
VIP score from de PLS-DA model was used. By this analysis it was possible to verify
that the methodology developed was effective for identification of the footprint left by
potential adulterants in the milk. Regarding the elected markers, the vast majority are
regular constituents of the milk, but they are found in their oxidized form, as presented
in Table 1, which is explainable by the chemical nature of the adulterants chosen (Singh
& Gandhi, 2015). This is a differential to this methodology once it is no longer the
presence of the adulterant itself that is analyzed but the effects of it on the adulterated
matrix, in this case raw milk.
40
Such adulterants as sodium hydroxide, sodium hypochlorite, hydrogen peroxide,
and formaldehyde are important oxidant agents added to fresh milk to increase shelf life
of the final product. Since milk is a highly perishable food, the main issue tackled by
these adulterants is the natural degradation. Thus, by the addition of these compounds,
chemical interactions occur with the milk components that act byneutralizing the
medium and eventually reducing microbial growth, avoiding the appearance of color
changes, odor, taste and viscosity, marked characteristics of a deteriorated product
(Nascimento et al., 2017; Singh & Gandhi, 2015). In a complex matrix such as milk, it
is expected that the molecular classes most affected by oxidation are the lipids and
proteins. The consumption of oxidized lipids and proteins is widely discussed in the
literature regarding hazardous effects, more specifically the increase in systemic
oxidative stress and the generation of reactive oxygen species (ROS) in mammals (Celi
& Gabai, 2015; Sies, Stahl, & Sevanian, 2005). Thus, providing the characterization of
endproducts from oxidative processes in adulterated milk is an important task that
generates useful information for food safety and consumer health maintenance.
41
Figure 1. PLS-DA scores plot showing clustering among adulterated milk samples,
separated from fresh raw milk. (A) Scores plot of sodium hydroxide using positive
mode data. (B) Scores plot of sodium hypochlorite using positive mode data. (C) Scores
plot of hydrogen peroxide using the negative mode data. (D) Scores plot of the
formaldehyde using the negative mode data.
42
Figure 2. DI-HRMS fingerprints in the positive mode of adulterated milk samples (A =
fresh raw milk/control; B = milk added 1 % v/v of sodium hydroxide solution; C = milk
added 1 % v/v of sodium hypochlorite solution).
43
Figure 3. DI-HRMS fingerprints in the negative mode of adulterated milk samples (A =
fresh raw milk/control; B = milk added 1 % v/v of hydrogen peroxide solution; C =
milk added 1 % v/v of formaldehyde solution).
44
Focusing on this new perspective on food adulteration, particularly detailing
each type of adulterant, both sodium hydroxide and sodium hypochlorite presented
mostly oxidized lipids as markers, as presented in Table 1. This can be attributed to the
oxidative characteristic of these adulterants, which were able to interfere in milk
composition even at low concentrations, probably oxidizing lipid double bonds forming
stabilized lipid alcohols. Milk is an important source of lipids (Lindmark Månsson,
2008) and fat-soluble vitamins (A, D, E, K). In addition, these components act to
provide the characteristic flavor of both milk and dairy products and for their
rheological properties as well. Whereas oxidized species may present reduction/absence
of these properties (Fox, Uniacke-Lowe, McSweeney, & O'Mahony, 2015a) or, in the
worstcase scenario, alter biochemical functions leading to deleterious effects, these
oxidized endproducts could act as injurious chemicals that activate inflammatory
responses that affects the circulatory system and also organs such as liver, kidney, lung,
and the gut (Kanner, 2007).
By the mass spectrum data analysis of the sodium hydroxide adulterant (Fig. 2)
four oxidized fatty acids were found and all of them may be attributed to both the
breakdown of larger lipid chains and the oxidation of their own chain. The four markers
found are: 5-hydroxy-4-oxoheptanoic acid, 2-hydroxy-3-oxooctanoic acid, 6,8-
dihydroxy-octanoic acid and 4,7-dioxododecanoic acid. For sodium hypochlorite were
found five oxidized milk compounds: D-galacturonic acid calcium salt, a carboxylic
acid derived from the oxidation of galactose; (E)-2-((9-hydroxy-10-
oxotetradecanoyl)oxy)-3-(phosphonooxy)propyl tetradec-9-enoate which is an oxidized
phosphatidic acid with two myristoleic acid moieties; D-glyceraldehyde-3-
phosphate/(3-hydroxy-2-oxo-propoxy) phosphonic acid/(2S)-2-Phospholactate, isomers
that are oxidized forms of phosphoglycerol, possibly due to the breakdown of complex
lipid chains; and finally, the oxidized phosphatidylcholine (PC) (16:0/5:1) ((E)-2-((5-
oxopent-3-enoyl)oxy)-3-(palmitoyloxy)propyl (2-(trimethylammonio)ethyl) phosphate),
which is a phosphatidylcholine potentially derived from the breakdown of larger PC
pecies and oxidized C16 Sphingosine (2-amino-1,3,4-trihydroxyhexadecan-5-one). As
expected the same behavior was observed for both sodium hydroxide and sodium
hypochlorite adulterants once there are oxidative compounds (Fox et al., 2015a;
O'Callaghan et al., 2016). The markers of these two groups were found in the positive
ion mode, as shown in Fig. 2.
45
Milk also contains a significant amount of polypeptides that act as an important
source of amino acids. The polypeptides is an important issue on the nutritional value of
milk since it is directly related with the growth rate of the offspring, once for mammals,
the milk is the main, when it is not the only, amino acid source in the first stages of life
(Fox,Uniacke-Lowe, McSweeney, & O'Mahony, 2015b). As lipids, the proteins are also
susceptible to oxidants, and may suffer denaturation and/or cleavage depending on the
severity of the oxidizing agent, thereby losing their nutritious properties (Østdal,
Bjerrum, Pedersen, & Andersen, 2000).
For hydrogen peroxide adulterant four markers were found, and for this
adulterant it were oxidized amino acids and small peptides (Table 1), which may be
attributed to the breakdown of proteins present in milk. The markers found were:
Lysinoalanine oxidized (2-amino-6-((2-amino-2-carboxyethyl) (hydroxy)amino)
hexanoic acid), Prolyl- Histidine oxidezed (4-((S)-2-((S)-N-hydroxy-3,4-dihydro-2H-
pyrrole-2- carboxamido)-3-oxopropyl)imidazol−1-ide), N-gamma-L-Glutamyl-L
methionine oxidized (5-((1-carboxy-3-(methylthio)propyl)(hydroxy) amino)-2-imino-5-
oxopentanoic acid) and (16E,18Z)-15-oxotetracosa-16,18-dienoic acid. These markers
demonstrate that oxidation by H2O2 is more severe than the previous two adulterants,
probably acting by radical-forming mechanisms to cause the observed protein oxidation.
The spectrum of the adulterated milk with hydrogen peroxide is present at Fig. 3.
45
Adulterant Compound Adduct Exact Mass Theoretical Mass Error MID*
Sodium
hydroxide
Heptenoic acid [M+Na]+ 183.0631 183.0628 1.64 34705
Octenoic acid [M+K]+ 213.0528 213.0524 1.88 4146
Octanoic acid [M+H-2H2O]+ 141.0919 141.0921 -1.42 74602
Dodecadienoic acid [M+K]+ 267.0989 267.0993 -1.50 45778
Sodium
hypochlorite
D-Galacturonic acid, calcium salt [M+NH4]+ 444.0654 444.0661 -1.58 71721
PA (14:1/14:1) [M+2Na-H]+ 665.3410 665.3401 1.35 82087
D-Glyceraldehyde-3-phosphate /
Dihydroxyacetone phosphate /
2-Phospholactate
[M+2Na-H]+ 214.9689 214.9692 -1.40
3294/
72896/
148
PC (16:0/5:1) [M+2Na-H]+ 638.3395 638.3404 -1.41 39414
C16 Sphingosine [M+K]+ 342.2035 342.2041 -1.75 53900
Hydrogen
peroxide
Lysinoalanine [M+Cl]- 284.1024 284.1019 1.76 86274
Prolyl-Histidine [M-H2O-H]- 249.0984 249.0988 -1.61 85916
N-gamma-L-Glutamyl-L-methionine [M+K-2H]- 331.0377 331.0371 1.81 89878
15-oxo-18Z-tetracosenoic acid [M+K-2H]- 417.2785 417.2777 1.92 74786
Formaldehyde
Indolelactic acid [M+FA-H]- 250.0716 250.0721 -2.00 71
3,6-Dideoxy-L-galactose [M+FA-H]- 193.0715 193.0718 -1.55 65959
Gly-Asp-Ser-Met [M+FA-H]- 453.1289 453.1297 -1.77 144589
Gln-Asp-Tyr-Met [M+FA-H]- 600.1989 600.1981 1.33 208669
His-Asn-Cys [M+FA-H]- 417.1205 417.1198 1.68 15770
Table 1. List of compounds found for each of the types of adulterants used. *METLIN ID
46
Finally, due to formaldehyde characteristic of conjugating with other species, a
series of formylated compounds were found. In total five compounds were identified:
indolelactic acid, 3,6-dideoxy-L-galactose; two tetrapeptides: Gly-Asp-Ser-Met, Gly-
Asp-Tyr-Met and one tripeptide, His-Asn-Cys. These results show that the
formaldehyde is a milder oxidant substance than the others three, however
formaldehyde still causes damages on milk, forming adducts that, similarly to the other
cases, have impaired the nutritional value that can lead to malnutrition on the long term
for those who use milk as a source of amino acids.
In this contribution, it is possible to observe that even though there are different
types of reaction mechanisms by which the adulterants selected herewith act, all of them
yielded similar outcomes in terms of oxidized species that impair the nutritional value
of the milk intended for consumption. In this way, this work was intended to provide a
better understanding of the behavior of milk constituents under a series of different
chemicals used for adulteration. Finally, our findings also support the importance of
chemical analyses of milk, whereas depending on the adulterant, different outcomes
may be expected, i.e. lipid oxidation, protein oxidation, and formation of formylated
species, components that are not declared in the specifications of the product. These
preliminary data will contribute in the development of a robust method based on the use
of DI-HRMS to analyze the effects of adulterants at nutritional components of milk.
Supplementary data to this article can be found online at
https://doi.org/10.1016/j.foodres.2018.03.079
Authors Contributions
TG and MR performed sample collection and experiments. TG, DO and CM performed
data analysis. TG wrote the manuscript. DO and EOL performed manuscript review. RC
idealized all experiments and managed the research group.
Conflict of interest
The authors declare that the research was conducted in the absence of any commercial
or financial relationships that could be construed as a potential conflict of interest.
Acknowledgements and Funding
The authors would like to thank the São Paulo Research Foundation (FAPESP) for the
financial support provided through process Nos.: 2015/06809-1 and 2016/17066-2. The
47
authors would also like to thank the Coordination for the Improvement of Higher
Education Personnel (CAPES) for the fellowships provided through process Nos.
1489740, 1645986, 1578388.
References
Celi, P., & Gabai, G. (2015). Oxidant/antioxidant balance in animal nutrition and health: The
role of protein oxidation. Frontiers in Veterinary Science, 2, 48.
De Oliveira, D., & Catharino, R. (2015). Direct metabolic fingerprinting of olive oils using
STELDI-MS. Journal of Food Composition and Analysis, 38, 131–134.
Food and Agriculture Organization of the United Nations - FAO (2016). Food outlook -biannual
report on global food markets, june 2016. Rome, Italy. Available at http://www.fao.org,
Accessed date: November 2017.
Fox, P., Uniacke-Lowe, T., McSweeney, P., & O'Mahony, J. (2015a). Milk lipids. Dairy
chemistry and biochemistry (pp. 69–144). Springer.
Fox, P., Uniacke-Lowe, T., McSweeney, P., & O'Mahony, J. (2015b). Milk proteins. Dairy
chemistry and biochemistry (pp. 145–239). Springer.
Guerreiro, T. M., de Oliveira, D. N., Ferreira, M. S., & Catharino, R. R. (2014). Highthroughput
analysis by SP-LDI-MS for fast identification of adulterations in commercial balsamic
vinegars. Analytica Chimica Acta, 838, 86–92.
Guerreiro, T. M., Gonçalves, R. F., Melo, C. F. O. R., de Oliveira, D. N., Lima, E. D. O.,
Visintin, J. A., ... Catharino, R. R. (2018). A Metabolomic overview of follicular fluid
in cows. Frontiers in Veterinary Science, 5, 10.
Hemme, T., Uddin, M. M., & Ndambi, O. A. (2014). Benchmarking cost of milk production in
46 countries. Journal of Reviews on Global Economics, 3, 254–270.
Ibáñez, C., Simó, C., García-Cañas, V., Acunha, T., & Cifuentes, A. (2015). The role of direct
high-resolution mass spectrometry in foodomics. Analytical and Bioanalytical
Chemistry, 407(21), 6275–6287.
International Farm Comparison Network - IFCN (2014). Dairy report, 2010–2014. Germany:
Kiel. Available at http://www.ifcndairy.org, Accessed date: November 2017.
Jeong, H.-S., Chung, H., Song, S.-H., Kim, C.-I., Lee, J.-G., & Kim, Y.-S. (2015). Validation
and determination of the contents of acetaldehyde and formaldehyde in foods.
Toxicological Research, 31(3), 273.
Jha, S. N., Jaiswal, P., Borah, A., Gautam, A. K., & Srivastava, N. (2015). Detection and
quantification of urea in milk using attenuated total reflectance-Fourier transform
infrared spectroscopy. Food and Bioprocess Technology, 8(4), 926–933.
Kanner, J. (2007). Dietary advanced lipid oxidation endproducts are risk factors to human
health. Molecular Nutrition & Food Research, 51(9), 1094–1101.
Kapaj, A., & Deci, E. (2017). World milk production and socio-economic factors effecting its
consumption. Dairy in human health and disease across the lifespan (pp. 107–115).
Elsevier.
Lindmark Månsson, H. (2008). Fatty acids in bovine milk fat. Food & Nutrition Research,
52(1), 1821.
Lu, Y., Xia, Y., Liu, G., Pan, M., Li, M., Lee, N. A., & Wang, S. (2017). A review of methods
for detecting melamine in food samples. Critical Reviews in Analytical Chemistry,
47(1), 51–66.
Melo, C. F. O., Delafiori, J., de Oliveira, D. N., Guerreiro, T. M., Esteves, C. Z., Lima, E. D. O.,
... Freitas, A. R. (2017). Serum metabolic alterations upon Zika infection. Frontiers in
Microbiology, 8, 1954.
Ministério da Pecuária e do Abastecimento - MAPA (2016). Mapa e Embrapa desenvolvem
sistema que qualifica políticas públicas para o leite. Brazil: Brasília. Available at
http://www.agricultura.gov.br, Accessed date: November 2017.
48
Nascimento, C. F., Santos, P. M., Pereira-Filho, E. R., & Rocha, F. R. (2017). Recent advances
on determination of milk adulterants. Food Chemistry, 221, 1232–1244.
O'Callaghan, T. F., Hennessy, D., McAuliffe, S., Kilcawley, K. N., O'Donovan, M., Dillon, P.,
... Stanton, C. (2016). Effect of pasture versus indoor feeding systems on raw milk
composition and quality over an entire lactation. Journal of Dairy Science, 99(12),
9424–9440.
Østdal, H., Bjerrum, M., Pedersen, J., & Andersen, H. J. (2000). Lactoperoxidase-induced
protein oxidation in milk. Journal of Agricultural and Food Chemistry, 48(9), 3939–
3944.
Pereira, P. C. (2014). Milk nutritional composition and its role in human health. Nutrition,
30(6), 619–627.
Rani, A., Sharma, V., Arora, S., Lal, D., & Kumar, A. (2015). A rapid reversed-phase thin layer
chromatographic protocol for detection of adulteration in ghee (clarified milk fat) with
vegetable oils. Journal of Food Science and Technology, 52(4), 2434–2439.
Reanpang, P., Themsirimongkon, S., Saipanya, S., Chailapakul, O., & Jakmunee, J. (2015).
Cost-effective flow injection amperometric system with metal nanoparticle loaded
carbon nanotube modified screen printed carbon electrode for sensitive determination of
hydrogen peroxide. Talanta, 144, 868–874.
Riccio, M. F., Sawaya, A. C., Abdelnur, P. V., Saraiva, S. A., Haddad, R., Eberlin, M. N., &
Catharino, R. R. (2011). Easy ambient sonic-spray ionization mass spectrometric of
olive oils: Quality control and certification of geographical origin. Analytical Letters,
44(8), 1489–1497.
Sies, H., Stahl, W., & Sevanian, A. (2005). Nutritional, dietary and postprandial oxidative
stress. The Journal of Nutrition, 135(5), 969–972.
Singh, P., & Gandhi, N. (2015). Milk preservatives and adulterants: Processing, regulatory and
safety issues. Food Reviews International, 31(3), 236–261.
Tay, M., Fang, G., Chia, P. L., & Li, S. F. Y. (2013). Rapid screening for detection and
differentiation of detergent powder adulteration in infant milk formula by LC–MS.
Forensic Science International, 232(1–3), 32–39.
United States Department of Agriculture - USDA (2017). Dairy: World markets and trade/July
2017. Washington, D.C., United States: Foreign Agricultural Service. Available at
https://www.usda.gov/, Accessed date: November 2017.
Verma, A., & Ambatipudi, K. (2016). Challenges and opportunities of bovine milk analysis by
mass spectrometry. Clinical Proteomics, 13(1), 8.
Vivian, A. F., Aoyagui, C. T., de Oliveira, D. N., & Catharino, R. R. (2016). Mass spectrometry
for the characterization of brewing process. Food Research International, 89,281–288.
Xia, J., Sinelnikov, I. V., Han, B., & Wishart, D. S. (2015). MetaboAnalyst 3.0—Making
metabolomics more meaningful. Nucleic Acids Research, 43(W1), W251–W257.
49
Suplementary Material:
Figure 1SM: PLS-DA scores plot showing clustering among adulterated milk samples
with concentration of adulterant of 2.5% v/v separated from fresh raw milk. (A = Scores
plot of sodium hydroxide solution using positive mode data; B = Scores plot of sodium
hypochlorite solution using positive mode data; C = Scores plot of hydrogen peroxide
solution using the negative mode data; D = Scores plot of the formaldehyde solution
using the negative mode data).
50
Figure 2SM: PLS-DA scores plot showing clustering among adulterated milk samples
with concentration of adulterant of 5% v/v separated from fresh raw milk. (A = Scores
plot of sodium hydroxide solution using positive mode data; B = Scores plot of sodium
hypochlorite solution using positive mode data; C = Scores plot of hydrogen peroxide
solution using the negative mode data; D = Scores plot of the formaldehyde solution
using the negative mode data).
51
Figure 3SM: PLS-DA scores plot showing clustering among adulterated milk samples
with concentration of adulterant of 10% v/v separated from fresh raw milk. (A = Scores
plot of sodium hydroxide solution using positive mode data; B = Scores plot of sodium
hypochlorite solution using positive mode data; C = Scores plot of hydrogen peroxide
solution using the negative mode data; D = Scores plot of the formaldehyde solution
using the negative mode data).
52
4.2 ARTIGO II
Migration from Plastic Packaging into Meat101
Tatiane Melina Guerreiro1, Diogo Noin de Oliveira1, Carlos Fernando Odir Rodrigues
Melo1, Estela de Oliveira Lima1 and Rodrigo Ramos Catharino1*
1 Innovare Biomarkers Laboratory, School of Pharmaceutical Sciences, University of
Campinas – UNICAMP, Campinas, SP, Brazil.
* Correspondence: Prof. Rodrigo Ramos Catharino ([email protected])
Abstract
Migration is a known phenomenon defined as the partitioning of chemical compounds
from the packaging into food, and depends on several factors. Migration assays are
generally time-consuming and require specific conditions in order to investigate the
behavior of the packaging in different situations. Furthermore, these tests are often
performed with food simulants, since the determination of migration under real
conditions is highly impaired. Several methodologies have been designed to carry out
this study, but an ideal approach should be capable of assessing the migration of
compounds in real samples, providing fast and reliable results. Within this context, mass
spectrometry can be considered a suitable and versatile technique that shows great
potential to accurately characterize several contaminants in food by migration. Thus, in
this work we present a mass spectrometry-based application for the detection of several
compounds from plastic, directly from vacuum-packed meat samples. This preliminary
and simple workflow can be easily applied in routine analyses for either quality control
purposes or in the prospection of other potential bioactive contaminants in food.
Keywords: migration, plastic, package, meat, contamination, contaminants.
Introduction
The term 'plastic' is used to describe materials based on modified synthetic or
natural polymers, which may be molded using heat and/or pressure. Plastic materials
used in packaging are very diverse in their chemical structure, presenting variable
properties depending on the processing, incorporated additives and combination with
other polymers (Robertson, 2006). For the food industry, with the increasing demand
53
for industrialized products, flexible plastic packaging has been widely used due to their
versatility and also to increase the product’s shelf life (Robertson, 2006).
Flexible plastic packages may be composed of thermoplastic material, which is
molded by increasing temperatures, allowing them to be shaped according to the
product’s size and outline (Jr., Wagner, 2016). The most common example of this class
would be vacuum packages, which are usually employed in the packaging of meat
products (McMillin, 2017). This type of packaging consists of a multilayer film, aimed
at combining the properties of each of the films in its constitution. The main polymer
used in the manufacturing process of such package is polyamide, due to its
characteristics of high abrasion resistance, thermoformability and resistance up to 200ºC
(Robertson, 2006). Additionally, other commonly used polymers are polyethylene
terephthalate (PET), polyvinylidene chloride (PVC), and ethylene vinyl alcohol
(EVOH). These polymers are more expensive, and some of them are sensitive to
moisture or heat sealing. Because of that, low-cost polymers such as polypropylene
(PP), polyethylene (PE) and polyethylene copolymers, are mixed in due to their
capability of being heat-sealed for lamination or coextrusion (K. H. Lee & Sun, 2016).
More recently, mixing other additives with the polymer base has been a common
practice to improve the mechanical behavior of plastic films. Since the technical
requirements for many flexible packaging applications are very demanding, they can
only be achieved by combining layers with different polymeric materials and additives
to form a structure that meets the desired performance needs (K. H. Lee & Sun, 2016).
Within the context of the thermoplastic material technology, the term "additive" or
"process coadjutant" is used to denote an ingredient capable of enhancing the properties
of a polymer without significantly altering its chemical structure, thereby improving
polymer resin transformation through changes in physical properties and mechanical
properties of the final material. Regarding food packaging, all additives used must be
certified by the specific regulatory authority (Robertson, 2006).
Several contributions in the literature show that there is possibility of migration
of components from the packaging to the conditioned product (K. T. Lee, 2010;
Sanches Silva, Cruz, Sendón García, Franz, & Paseiro Losada, 2007). Migration is
defined as the partitioning of chemical compounds by diffusion or absorption from the
packaging into the food (Arvanitoyannis & Kotsanopoulos, 2014; Fasano, Bono-Blay,
Cirillo, Montuori, & Lacorte, 2012; Lau & Wong, 2000; Tehrany & Desobry, 2004).
Contamination of food by migration of monomers or additives is a relevant matter for
54
health legislations due to potential health-related risks. Thus, packaging materials
intended for the packaging of foodstuffs must be registered and approved after assessing
the absence of toxic effects to the consumer and organoleptic changes to the food
(Cherif Lahimer, Ayed, Horriche, & Belgaied, 2017; Mercosul, 2007; Muncke et al.,
2017). However, this is still a subject of much debate due to the lack of information and
more detailed studies on the safety of exposure to these possible contaminants, as well
as assertive determination of the number of allowed compounds and migration limits
(Muncke et al., 2017).
Moreover, this phenomenon depends on several factors such as chemical
composition of the conditioned food, level, time and temperature of contact with the
package, and chemical properties of the packaging material (Arvanitoyannis &
Kotsanopoulos, 2014). Migration tests generally have a long experimental workflow,
and require specific conditions of temperature and humidity in order to mimic
conditions of conservation or to generate stress conditions to investigate the behavior of
the packaging. Furthermore, since food is a complex matrix both chemically and
physically, food simulants are frequently used. These products have defined
composition and characteristics that mimic the composition of food classes, facilitating
the determination of migration, since working under real conditions is an important
methodological challenge (Arvanitoyannis & Kotsanopoulos, 2014; Tehrany &
Desobry, 2004).
For this reason, developing an expeditious and accurate methodology, capable of
being applied to study the migration of compounds in real samples would represent an
important advancement in food analysis. In this context, mass spectrometry has proven
to be a great ally for the identification and characterization of compounds in complex
samples, from biological fluids to food, exhibiting versatility, sensitivity, and accuracy
(Guerreiro et al., 2018; Guerreiro, Oliveira, Ferreira, & Catharino, 2014; Melo et al.,
2017; Vivian, Aoyagui, de Oliveira, & Catharino, 2016). High-resolution mass
spectrometry (HRMS) is a powerful technique that provides reliable information about
the characterization of unknown compounds within any given matrix, with enhanced
accuracy and precision (Rubert, Zachariasova, & Hajslova, 2015). In this way, our work
presents a preliminary and simple methodology for the identification of several
plasticizers migrating from vacuum-packages into meat samples using HRMS as the
main detection technique.
55
Materials and Methods
Sample Preparation
Fifteen pieces of vacuum-packed beef meat from the same batch and brand were
purchased from supermarkets in the city of Campinas, São Paulo, Brazil. From each
package, triplicates of both beef meat and packaging material were sampled and
prepared as described below.
An amount of packaging material equivalent to 2 mg was added to 500 μL of
tetrahydrofuran (THF) (242888, Sigma-Aldrich, Saint Louis, USA). The mixture was
sonicated at room temperature for 10 minutes, where dissolution of most of the plastic
material occurred. To this solution, 500 μL of methanol (34860, Sigma-Aldrich, Saint
Louis, USA) was added, and the final resulting solution was homogenized in vortex for
1 minute.
For beef meat samples, a piece of approximately 2 mg was cut from different
areas in the surface and 2.5 to 3 cm deep, which underwent the same extraction protocol
as that described for the packaging material. In addition, a negative control was
performed with fifteen beef meat samples purchased directly from a butcher's shop in
the city of Campinas, São Paulo, Brazil, so that these samples were not conditioned in
any type of plastic packaging. All purchased meat was from the same type of beef cut
(Brazilian rump), with similar fat content, to avoid any potential bias in the results.
Prior to HRMS analyses, 1 μL of formic acid (F0507, Sigma-Aldrich, Saint
Louis, USA) was added to 500 μL of the final solution.
High Resolution Mass Spectrometry (HRMS)
Samples were directly injected into an ESI-LTQ-XL Orbitrap Discovery
(Thermo Scientific, USA). Acquisitions were performed in the positive mode, in the
mass range of 70-700 m/z. Instrument parameters were: flow rate of 10 μL.min-1,
capillary temperature of 280 °C, 5 kV spray voltage and sheath gas at 10 arbitrary units.
HRMS analysis were performed in triplicates for each sample and its replicates (i.e. a
total of 540 spectra acquisitions). The online metabolomics database METLIN
(www.metlin.scripps.edu) was consulted to provide the candidate molecules during the
structure elucidation process, employing the value of the exact experimental mass
obtained in comparison with the theoretical mass, so that the error adopted between
these two values was < 2 ppm.
56
Compound Adducta Exact
Mass
Experimental
Mass
Error
(ppm) CAS
Phthalic Anhydride [M+H]+ 149.0233 149,0235 1,34207 85-44-9
Stearamide [M+H]+ 284.2947 284,2952 1,75874 124-26-5
Diisooctyl
phthalate
[M+H]+ 391,2843 391,2850 1,82476 84-69-5
[M+CH3CN+Na]+ 454.2927 454,2921 1,32073
Polyethylene glycol
(PEG)
[A9B+H]+ 415.2537 415,2543 1,44490
25322-68-3 [A9B+Na]+ 437.2357 437,2349 1,82968
[A9B +H]+ 453.2096 453,2088 1,76519
Results and Discussion
The analyses of all resulting survey spectra showed that HRMS was capable of
identifying 5 contaminants in all pieces of beef meat that were in contact with the
vacuum-plastic packaging, as presented in Table 1. The replicates analysis showed that
the methodology maintained the same spectral profile for each of the sample types
analyzed (negative control meat, packed meat and packaging material), which
demonstrates the reproducibility of the method. Their spectral profiles are presented at
Figure 1. Observing and comparing the spectra, no signals related to these compounds
are found in the spectrum from the butcher's shop beef meat (negative control, Figure
1A); instead, they are present at the profile for packaging material spectrum (Figure 1B)
and for packed beef meat spectrum (Figure 1C). In addition, for the spectrum of the
packaging material (Figure 1B) the signal intensity of the identified components is
greater than in the packaged beef meat spectrum (Figure 1C), which corroborates the
fact that these components belong to the analyzed material, and they were able to
migrate into meat. The profiles presented for the samples from superficial and deeper
cuts showed no differences.
Table 1. Contaminants found in meat samples from plastic package. (a Presented
adducts are in accordance with Keller et al, 2008 (Keller, Sui, Young, & Whittal, 2008))
57
Figure 1. HRMS spectra of the beef meat samples showing the presence of five
contaminants in all pieces of beef meat that were in contact with the vacuum-plastic
packaging. A: negative control butcher's shop beef meat; B: packaging spectrum; C:
packed beef meat spectrum.
58
Regarding the elucidated compounds of interest, three are related to the
manufacturing of polymers, providing strong evidence that they came from plastic
packaging, namely phthalic anhydride (149.0235 m/z), which is used in the
manufacturing process of organic polymers (European Commission, 2011); stearamide
(284.2952 m/z), an additive that is incorporated into the polymeric substrate to provide
enhanced stability and performance of the final product (Jr., Wagner, 2016) and
polyethylene glycol (PEG) (415.2542, 437.2349 and 453.2088 m/z), which is used in
combination with other polymers to provide hardness and ductility to the structure of
the material (Chieng, Ibrahim, Then, & Loo, 2016). Complementary with plastic
manufacture, the last compound is the diisooctyl phthalate (DIOP) (391.2850 and
454.2921 m/z), which has plasticizer function.
The migration phenomenon may lead to the contamination of the conditioned
product, due to direct and indirect interactions that may occur with the food product. In
the case of packaging-environment interactions, the interface between food and the
environment may be allowed according to the permeability level of the packaging, and
in the case of packaging-food interaction, the migration of monomers, oligomers and/or
food additives may occur due to the direct contact with the food (Lau & Wong, 2000).
Currently, two migration tests are required to release the use of chemicals in food
packaging: “Quantity in Material”, for carrying out the quantity of a substance which
may be present in the packaging material, and “Specific Migration”, for assessing the
quantity of a determinate substance that may possibly migrate to the food product
(Arvanitoyannis & Bosnea, 2004).
Currently, the majority of tests to identify migrating packaging components to
food are carried out using food simulants. These are needed because of the difficulty of
analyzing the wide range of food matrices and also the actual conditions or stress during
storage (Sanches Silva et al., 2007). Some analytical methods are already standardized,
but official methods are often long, complicated and impractical in a daily routine of
quality control. Releasing or restricting the use of substances in food packaging
involves the analyses of the risks and benefits, and the quality control of packaging
materials is heavily impaired. It is on account of the existence of more than 1,000
additives and monomers that are listed as potential migrants in the regulatory list of
positive substances, many of which are authorized with specific migration restrictions
or limits, and the general objective of the legislation is to ensure consumer safety
(Arvanitoyannis & Bosnea, 2004; Gillet, Vitrac, & Desobry, 2010).
59
In an attempt to control and harmonize the legislation on food packaging, the EU
(European Union) and the FDA (Food and Drugs Administration) created a list of
positive substances, which have their permitted use, and restricted substances, as they
have a potential toxic effect (Simoneau & Hannaert, 1999). However, problems about
this list involve mainly the lack of information on the toxicity of the substances,
especially the absence of studies related to the toxicity of the final product, and not just
of a specific compound, as currently evaluated. Moreover, studies on a mixture of
substances to ascertain potential synergistic effects are required, as well as studies on
the cumulative effects of exposure to these substances (Muncke et al., 2017).
In this context, fast screening methods such as HRMS refer to the agile
identification of possible agents coming from plastic packaging that can lead to
potential health risks to consumers. Research in this area should be guided by
improvements in the current analytical methods for food packaging control, aiming at
minimal prepare os samples, using a minimal quantity of solvents, and the rapid and
effective determination of potential migrants in food. At this work we presented a
preliminary methodology for screening possible migrants from plastic into beef meat
using only HRMS technique, and the results showed the potential of the use of this
technique at food industries for identification of compounds from packaging material.
Conclusions
Through the results obtained it was possible to develop a new, simple and
effective methodology, capable of identifying the phenomenon of migration of
packaging components to the conditioned food, without the need to use food simulants,
since the application was carried out in real samples. HRMS proved to be a reliable tool
in this context, due to its speed and sensitivity, showing an even broader potential for
application in the analysis of food contaminants.
Authors Contributions
TG performed sample collection, experiments and wrote the manuscript. CM, DO and
EL performed manuscript review. RC idealized all experiments and managed the
research group.
Conflict of interest
The authors declare that the research was conducted in the absence of any commercial
or financial relationships that could be construed as a potential conflict of interest.
60
Acknowledgements and Funding
The authors would like to thank the São Paulo Research Foundation (FAPESP) for the
financial support provided through process Nos.: 2015/06809-1 (RC) and 2016/17066-2
(CM). The authors would also like to thank the Coordination for the Improvement of
Higher Education Personnel (CAPES) for the fellowships provided through process
Nos. 1489740, 1645986, 1578388.
References
Arvanitoyannis, I. S., & Bosnea, L. (2004). Migration of Substances from Food Packaging
Materials to Foods. Critical Reviews in Food Science and Nutrition, 44(2), 63–76.
https://doi.org/10.1080/10408690490424621
Arvanitoyannis, I. S., & Kotsanopoulos, K. V. (2014). Migration Phenomenon in Food
Packaging. Food-Package Interactions, Mechanisms, Types of Migrants, Testing and
Relative Legislation-A Review. Food and Bioprocess Technology.
https://doi.org/10.1007/s11947-013-1106-8
Cherif Lahimer, M., Ayed, N., Horriche, J., & Belgaied, S. (2017). Characterization of plastic
packaging additives: Food contact, stability and toxicity. Arabian Journal of Chemistry,
10, S1938–S1954. https://doi.org/10.1016/j.arabjc.2013.07.022
Chieng, B. W., Ibrahim, N. A., Then, Y. Y., & Loo, Y. Y. (2016). Mechanical, thermal, and
morphology properties of poly(lactic acid) plasticized with poly(ethylene glycol) and
epoxidized palm oil hybrid plasticizer. Polymer Engineering and Science, 56(10), 1169–
1174. https://doi.org/10.1002/pen.24350
European Commission. SCOEL/SUM/152, Pub. L. No. SCOEL/SUM/152, 24 (2011).
Fasano, E., Bono-Blay, F., Cirillo, T., Montuori, P., & Lacorte, S. (2012). Migration of
phthalates, alkylphenols, bisphenol A and di(2-ethylhexyl)adipate from food packaging.
Food Control, 27(1), 132–138. https://doi.org/10.1016/j.foodcont.2012.03.005
Gillet, G., Vitrac, O., & Desobry, S. (2010). Prediction of partition coefficients of plastic
additives between packaging materials and food simulants. Industrial and Engineering
Chemistry Research, 49(16), 7263–7280. https://doi.org/10.1021/ie9010595
Guerreiro, T. M., Gonçalves, R. F., Melo, C. F. O. R., de Oliveira, D. N., Lima, E. de O.,
Visintin, J. A., … Catharino, R. R. (2018). A Metabolomic Overview of Follicular Fluid in
Cows. Frontiers in Veterinary Science, 5(February), 1–9.
https://doi.org/10.3389/fvets.2018.00010
Jr., Wagner, J. R. (2016). Multilayer Flexible Packaging. Elsevier.
https://doi.org/10.1017/CBO9781107415324.004
Lau, O.-W., & Wong, S.-K. (2000). Contamination in food from packaging material. Journal of
Chromatography A, 882(1–2), 255–270. https://doi.org/10.1016/S0021-9673(00)00356-3
Lee, K. H., & Sun, D.-W. (2016). Handbook of frozen food processing and packaging. (D.-W.
Sun, Ed.) (Second Edi). New York: CRC Press.
Lee, K. T. (2010). Quality and safety aspects of meat products as affected by various physical
manipulations of packaging materials. Meat Science.
https://doi.org/10.1016/j.meatsci.2010.04.035
McMillin, K. W. (2017). Advancements in meat packaging. Meat Science.
https://doi.org/10.1016/j.meatsci.2017.04.015
Melo, C. F. O. R. (2017). Serum Metabolic Alterations upon Zika Infection. Frontiers in
Microbiology, 8. https://doi.org/10.3389/fmicb.2017.01954
Mercosul. MERCOSUL/GMC/RES. No 32/07, Pub. L. No. No 32/07, 4 (2007).
Muncke, J., Backhaus, T., Geueke, B., Maffini, M. V., Martin, O. V., Myers, J. P., …
Scheringer, M. (2017). Scientific challenges in the risk assessment of food contact
61
materials. Environmental Health Perspectives. https://doi.org/10.1289/EHP644
Robertson, G. L. (2006). Food Packaging: Principles and Practice. IFLA Journal (Vol. 32).
https://doi.org/10.1177/0340035206070163
Rubert, J., Zachariasova, M., & Hajslova, J. (2015). Advances in high-resolution mass
spectrometry based on metabolomics studies for food – a review. Food Additives &
Contaminants: Part A, 32(10), 1685–1708.
https://doi.org/10.1080/19440049.2015.1084539
Sanches Silva, A., Cruz, J. M., Sendón García, R., Franz, R., & Paseiro Losada, P. (2007).
Kinetic migration studies from packaging films into meat products. Meat Science, 77(2),
238–245. https://doi.org/10.1016/j.meatsci.2007.03.009
Simoneau, C., & Hannaert, P. (1999). Stability testing of selected plastics additives for food
contact in EU aqueous, fatty and alternative simulants. Food Additives and Contaminants,
16(5), 197–206. https://doi.org/10.1080/026520399284064
Tehrany, E. A., & Desobry, S. (2004). Partition coefficients in food/packaging systems: A
review. Food Additives and Contaminants. https://doi.org/10.1080/02652030400019380
Vivian, A. F., Aoyagui, C. T., de Oliveira, D. N., & Catharino, R. R. (2016). Mass spectrometry
for the characterization of brewing process. Food Research International, 89, 281–288.
https://doi.org/10.1016/j.foodres.2016.08.008
62
4.3 ARTIGO III
New Approach of QuEChERS and GC-MS Triple-Quadrupole for the
Determination of Ethyl Carbamate content in Brazilian cachaças32
Tatiane Melina Guerreiro1‡, Kumi Shiota Ozawa2‡, Estela de Oliveira Lima1, Carlos
Fernando Odir Rodrigues Melo1, Diogo Noin de Oliveira1, Simone Pereira do
Nascimento Triano2, and Rodrigo Ramos Catharino1*
1Innovare Biomarkers Laboratory, School of Pharmaceutical Sciences, University of
Campinas, Campinas, SP, Brazil. 2Agilent Technologies Brasil, São Paulo, SP, Brazil.
* Correspondence: Rodrigo Ramos Catharino ([email protected]) ‡ These authors contributed equally.
Abstract
Cachaça is a popular spirit produced in Brazil, obtained by distillation of fermented
sugarcane. Among the contaminants arising from production, ethyl carbamate is a
carcinogenic compound that occurs naturally in fermented foods and beverages; in
Brazil, the maximum limit established by current legislation is 150 μg L−1. Quality
control is usually performed using gas chromatography; however, robustness and
reproducibility of quantitative results may be severely impaired, as the addition of 6–30
g L−1 of sucrose is a common procedure for taste standardization, directly interfering in
the results. This work describes the development of a novel method to improve ethyl
carbamate quantification in cachaças using a new approach of QuEChERS extraction
based on salting-out phenomenon, to effectively separate ethanol from sugar-containing
water. Eighteen different brands of cachaça were analyzed. The proposed methodology
was able to eliminate components that contaminate the sample flow path in the gas
chromatography system, while improving precision and accuracy by using a triple-
quadrupole approach, in comparison with the methodology usually employed: direct
analysis of cachaça samples with no sample prep. Results indicate that this approach is
more effective due to the removal of sugar content, with no impact in costs per analysis.
Keywords: alcoholic beverages; cachaça; ethyl carbamate; gas chromatography-mass
spectrometry; QuEChERS
63
Introduction
Cachaça is the typical and exclusive denomination of a sugar cane spirit
produced in Brazil. Characteristics that define this product are the alcohol content
reaching 38–48% ABV (alcohol by volume) at 20°C and obtainment by distillation of
fermented sugar cane juice (1). The manufacturing process of cachaça is not
standardized in several aspects. The first is regarding the type of sugarcane used, since
there are several varieties currently used, which present great similarity in their
composition (2). In addition, grains such as corn or rice may also be added to the must
in order to provide nutrients for better development of yeasts responsible for
fermentation (3). Finally, the equipment used may be different as well, since the
distillation may be carried out in columns of distillation made from stainless steel, in the
case of industrial production, or in copper stills, in the case of artisanal production (4).
The aging process in barrels of wood is similar to that applied in the manufacturing of
wine, where oak, balm, jequitibá, jatobá, or amburana barrels may be used. This last
process is optional and aims to provide aromas, flavors, and colors from the wood to the
cachaça (5). Regarding the sensorial characteristics, it is observed that high-quality
cachaça has a characteristic aromatic bouquet from sugar cane, as well as aromas and
unique flavors. However, in addition to the organoleptic aspects, cachaça must meet
some chemical parameters to assure that, with moderate consumption, the product
causes no health hazards. Contaminants such as methanol, sec-butanol, n-butanol,
copper, and ethyl carbamate, as well as acetic acid, an off-flavor responsible for the
acidity of cachaça, are key species that are directly linked to quality impairment of this
distillate (6, 7).
According to a 2007 assessment by IARC (International Agency for Research on
Cancer), ethyl carbamate was considered carcinogenic in laboratory animals, and
therefore, has been listed as a carcinogen for humans, belonging to Group 2A on the
Classification of Carcinogenic Substances (8, 9). This compound is an ethyl ester of
carbamic acid that is formed naturally in fermentation processes, which may be derived
from several different precursors, such as hydrocyanic acid, urea, citrulline, and N-
carbamyl by reaction with ethanol (4, 9–12). Due to this feature, it is easily found in
various types of food and beverages, such as spirits, wine, beer, bread, shoyu sauce, and
yogurt (13, 14). The consumption of ethyl carbamate only from food sources may be
deemed insignificant. However, by adding the intake of alcoholic beverages on a regular
basis, exposure to this compound increases; for example, cachaça figures as the third
64
most consumed distilled beverage in the world, and in Brazil it is the second most
consumed alcoholic beverage, after beer (15). Given its wide consumption, measures
must be taken regarding the reduction of ethyl carbamate concentration in alcoholic
beverages. Canada, through the “Health and Welfare Department” in 1985, was the first
country to determine concentration limits of ethyl carbamate in wines, distilled
beverages, fruit distillates, and liqueurs. Therefore, this became a reference for the
United States and European Union, regarding the legislation on this subject (16). In
1990, the FDA published a note limiting ethyl carbamate content in American whiskeys
in 125 μg L−1 (17). According to the Brazilian Ministry of Agriculture, Livestock, and
Supply, the limit for this contaminant in cachaças is 150 μg L−1 (1). The importance of
controlling ethyl carbamate levels, therefore, must be understood as an issue concerning
not only health aspects, but also economic ones, as any out-of-specification result may
represent a barrier to exporting Brazilian cachaça to both American and European
markets.
Many different approaches using mass spectrometry (MS) have been developed
in the recent years, assessing a great diversity of quality parameters from cachaça (18–
20), as well as many protocols for ethyl carbamate analysis and extraction (9). The use
of gas chromatography (GC) coupled with single-quadrupole MS is a technique widely
used for the analysis of this contaminant, as it is capable of accurately promoting both
identification and quantification in food and beverage samples (9). However, there is a
common procedure of sucrose addition in sugar cane spirits to reduce the alcoholic
flavor of the beverage and standardize its taste, improving its final sensory quality In the
case of cachaça, the Brazilian legislation allows the addition of up to 6 g L−1, as
procedure of standardization. Nonetheless, if the label states “sweetened,” the product
may contain up to 30 g L−1 of sugar (21). As GC-MS is the method of choice for the
quality control of cachaça, high sucrose content may easily contaminate the GC flow
path, thus making the maintenance of the equipment more frequent, and compromising
the accuracy of results. In this sense, the development of a methodology capable of
coping with exceeding amounts of sucrose present in cachaça, while maintaining the
precision and accuracy of the analysis, became necessary.
Related to the preparation of samples, carbamates usually occur at very low
concentrations and in complex matrices, as the cachaça samples, because of that they
cannot be determined without some preliminary sample pretreatments. A good
procedure of sample preparation should provide the preconcentrating of analytes and
65
also the clean-up, improved in this way the determination of the analyte of interest.
Recently, the search for miniaturized methods that are efficient and do not use large
amounts of toxic solvents to perform the extraction has been in focus. Thus, different
microextraction procedures have been developed as alternatives like the QuEChERS
(quick, easy, cheap, effective, rugged, and safe) methodology, which has been widely
used in the pretreatment of complex samples. This technique is based on a two-step
method where it is first performed an extraction step based on partitioning via the
salting-out phenomenon, which is responsible for the equilibrium between an aqueous
and an organic layer. The second step is a solid phase dispersive extraction, which
involves the cleanup of the sample using combinations of different kinds of sorbents
salts or primary-secondary amines with the objective to remove interfering substances
(22, 23).
In this work, we present a new approach of QuEChERS, based only on the
salting-out extraction, as a way to eliminate residues of sucrose and water for samples
of several brands of Brazilian cachaça, which was further corroborated by an
experiment using liquid chromatography (LC), without compromising the identification
and quantification of ethyl carbamate. Additionally, we compared this new
methodology developed by our group with the current recommended procedure for the
analysis of ethyl carbamate
Material and Methods
Reagents and standards
The standard of ethyl carbamate (99.0%) was purchased from Sigma Aldrich
(MO, USA). Potassium carbonate (99.6%) was purchased from Neon (Suzano, Brazil).
Cachaças of different Brazilian brands (9 commercial) and common sugar (sucrose)
were purchased from commercial establishments in the city of Campinas, Brazil. The
craft cachaças (9) were purchased from different artisanal producers in the countryside
of the States of São Paulo and Minas Gerais, Brazil. Ethanol was purchased from
Panreac AppliChem (Barcelona, Spain), Acetonitrile was purchased from J.T. Baker
(Xalostoc, Mexico); both were LC grade and were used with no further purification.
Deionized water was obtained with a Milli-Q system (Millipore, USA).
66
Sample preparation – New Approach of QuEChERS
In order to analyze samples of cachaça, a new methodology of QuEChERS was
developed. We performed a salting-out using 5 g of potassium carbonate added to 10
mL of sample and vortexed for 20 s. The tube was left to rest for 2 minutes until phase
separation and, after that, 1 mL of the alcoholic phase was transferred to a vial and
injected into Agilent GC/MS 7890/7000 Triple Quadrupole system. For the analysis
performed into an Agilent LC/MS/MS 6460 Triple Quadrupole system these same
samples were diluted 10 times (in water). All samples were prepared in triplicates.
LC-MS Analysis
In order to check the reduction of sucrose amount, samples were analyzed before
and after the QuEChERS with potassium carbonate. An aliquot of 100 μL of samples,
with or without QuEChERS proceeding, was diluted with 900 μL of deionized water. A
volume of 0.5 μL was injected at 65°C into an Agilent LC/MS/MS 6460 Triple
Quadrupole system. The two mobile phases used were (A). with 90% of water, and (B)
with 10% of acetonitrile. The flow rate was 0.350 mL min−1 and the column used was
an Agilent Hi-Plex Ca (USP L19) 8 μm, 4.0 mm × 250 mm. The mass spectrometer was
set to electrospray ionization mode (ESI) with capillary voltage at 5 kV. All samples
were prepared in triplicates and each of them were analyzed in triplicate
GC-MS Analysis
A stock solution of 2,000 mg L−1 was prepared using ethyl carbamate standard
diluted in ethanol. To build the calibration curve, an aliquot of the stock solution was
diluted in ethanol to yield a calibration solution with concentration of 10 mg L−1 of
ethyl carbamate. From this calibration solution, new dilutions were performed in order
to obtain six concentration points chosen for the construction of the external calibration
curve: 50, 100, 200, 500, 1,000, and 1,500 μg L−1. Concerning matrix interference, an
experiment with internal standard addition was performed, using a sandwich injection.
This experiment was performed in order to verify whether the QuEChERS approach
would clean up the sample by decreasing matrix interference and not impairing the ethyl
carbamate determination in the analyzed samples.
The instrument used was an Agilent GC/MS 7890/7000 Triple Quadrupole
system with Electron Ionization mode (EI). A volume of 2 μL of sample was injected in
split mode 1:5 at 280°C as inlet temperature. Nitrogen was used as collision gas with
67
flow rate of 1.5 mL min−1; Helium was used as carrier gas at flow rate of 1 mL min−1
and as quench gas at a flow rate of 2.25 mL min−1. The oven started at 90°C for 1 min
and the temperature increased at a rate of 10°C min−1 until the final temperature of
185°C, with a total running time of 10.5 min. The column used was Agilent VF-
WAXms 0.25 μm, 30 m × 0.25 mm and the mass spectrometer source temperature was
set to 300°C, while quadrupole Q1 and Q2 at 180°C. The Multiple Reaction Monitoring
transitions used were for the quantifier ion 62 → 44 with collision energy of 15 eV and
qualifier ion 74 → 44 with collision energy of 5 eV. All samples were analyzed in
triplicates
Sandwich Injection applied to GC-MS Analyses
The injection of the sample using the standard addition method was performed
by creating a different acquisition method for each calibration level. The first level was
composed only by the sample volume to be analyzed, thus the injection was 1 μL of
sample in split mode (1:5). The second level was the mixture between the sample and
one aliquot of standard; hence, the injection was performed by programming the
autosampler to take 1 μL of sample and 1 μL of standard. The standard vial was
prepared at concentration of 100 μg mL−1. The third level consisted of taking 1 μL of
sample and 2 μL of standard. Finally, the fourth level took again 1 μL of sample and 3
μL of standard (Figures 1 and 2). The standard was positioned in such a position in the
autosampler that the auto-injector could take the aliquot of standard solution always at
the same place. Upon each injection, the syringe was washed four times with ethanol
(40%) first, and six times with a deionized water: acetonitrile solution (80:20) after the
injection, both at the maximum volume of 10 μL.
68
Figure 1. Scheme of the solution preparation for the standard addition method.
Figure 2. Sandwich injection scheme.
69
Results and Discussion
Part I: Sucrose Content Verification by LC/MS/MS
The sugar present in cachaça, sucrose, is a naturally occurring saccharide found
in sugar cane. The solubility of sucrose in water is 1 g for 0.5 mL, and in ethanol is 1 g
for 170 mL. With the purpose of simulating the amount of sucrose in cachaça samples,
mock solutions of 0.3 and 0.06 g of sucrose in 10 mL of water were prepared, emulating
the maximum concentrations for not labeled (6 g L−1) and labeled (30 g L−1) sugar
addition. Figure 3 shows the Extracted Ion Chromatogram (EIC) 365 of sucrose (24) of
the 6 and 30 g L−1 preparations. Integration of the EIC 365 peak was performed and
compared before and after the QuEChERS extraction. Elimination of most of the sugar
was evident, since the solubility of sucrose in water is higher than in ethanol, as shown
in Figure 4 and in the data available in Table 1. This happened because when a salt is
added to an aqueous solution of a soluble organic solvent, the intermolecular
interactions are affected by the ionization of the salt because of the stronger affinity
between the ions and the water molecules. This reflects in decreased availability of
water molecules for the third component (i.e., organic solvent). Therefore, the organic
solvent is forced to increase its intermo-lecular interactions, and subsequently, at
threshold concentrations of the ionized species, the organic solvent is excluded from the
rest of the solution as a separate phase (25). This phenomenon is known as salting-out
and was applied in the development of this new approach of QuEChERS extraction
described here. In the present case, separation of ethanol from water by the QuEChERS
approach eliminates most of the sucrose due to its solubility, which was verified using
an LC/MS triple quadrupole system.
Area Before
Salting-Out
Area After
Salting-Out
Removal
Percentage
Control 6 g/L 83180455.52 405192.7900 99,51 %
Control 30 g/L 193679686.4 1906989.360 99,01 %
Cachaça Sample 82252299.47 706338.6600 99,10 %
Table 1. Sugar percentage removal by EIC peak area.
70
Figure 3. EIC chromatogram of solutions with 6 and 30 g/L of sugar and MS spectrum
of 365 (sucrose).
71
Figure 4. EIC chromatogram of 6 g/L of sugar (A) and with a sample of cachaça (B)
before and after QuEChERS extraction, injecting only the organic layer for both
samples.
72
Part II: Matrix Interference in GC/MS/MS and Standard Addition
Matrix interference is another issue involved in the analysis of ethyl carbamate
in alcoholic beverages using GC-MS. Even after sample cleanup by a diatomaceous
earth column, the identi-fication of ethyl carbamate often cannot be ascertained with
confidence by the selected ion monitoring (SIM) mode, due to inconsistent ratios of the
SIM ions 62, 74, and 44 m/z, since the qualifier ions are highly susceptible to matrix
interference (26). Therefore, the use of triple-quadrupoles for improved sensitivity and
specificity may clarify this interference.An alternative with the use of mixtures of
ethanol and water might be an option for blank samples, but they cannot compre-hend
all the potential matrix interference to the analysis. Thus, the standard addition method
is suggested to perform a quan-titative analysis approach where the standard is added
directly to the aliquots of the analyzed sample. This approach may be applied in cases
where a suitable blank sample is not available for calibration, as with cachaça samples.
Moreover, the method of standard addition can assist in identifying a target analyte in
any given chromatogram, as only the target peak increases after the addition. Figure 5
shows the overlapping chromatogram of samples added and not added with ethyl
carbamate standard. The only clear disadvantage of this method is the laborious task to
prepare the solution to determine the calibration curve. To per-form standard addition, it
is required to prepare a set of solutions that contains a same volume of sample and
increasing volume of standard solution, as shown in Figure 1. The methodology is based
in the addition of a constant volume (Vunk) of sample to each of the volumetric flasks,
with volume (Vflask), then adding a series of increasing volumes of stock solution
(Vstd). Finally, each flask is made up to the mark with solvent and mixed.
This process was further simplified by the use of sandwich injection (Figure 2)
performed by automatic injector of the GC system. This injection consists of taking an
aliquot of sample vol-ume and standard solution volume at the same time injecting both
the solution together, thus avoiding the preparation of the standard solution with varied
concentrations. Since the solvent is evapo-rated in GC injection port, the calibration
curve is based on mass injected in the column, instead of the concentration established
in the volumetric flask. Results compare the final concentration (FC) obtained by
standard addition and external calibration method.
73
Figure 5. Overlapping chromatogram of standard addition method, which shows the
gradual increase of the peak area of ethyl carbamate
Part III: Quantification of Ethyl Carbamate
The blank samples were prepared with ultrapure water and ethanol, with a FC of
40% ethanol. The samples were spiked with concentrations of 50, 100, and 200 μg L−1
of the standard. As the solubility of ethyl carbamate in ethanol (1.2 g mL−1) is higher
than in water (0.1 g mL−1), the FC in ethanol, after the QuEChERS extraction step, will
be proportional to that volume. For example, when adding 100 μL of a solution with a
concentra-tion of 10 ng μL−1 of ethyl carbamate, it is in the same proportion as 1,000
ng of ethyl carbamate in 10 mL of sample solution. After the QuEChERS extraction
step, 1,000 ng of ethyl carbamate will be present almost exclusively in the ethanol layer.
Thus, the FC in 1 mL of the upper layer (ethanol) will be approximately of 250 ng
μL−1, as shown in equation below. This was corroborated using the calibration curve
prepared in blank matrix:
C = 1000 ng / 4 mL(ethanol) = 250 ng µL-1 or 250 µg L-1
The recovery (Rec) was verified by spiking 50, 100, and 200 μL of intermediate
solution in 10 mL blank samples already cor-rected as per the equation above. For this
reason, the expected concentration for 50, 100, and 200 μg L−1 would be 125, 250, and
500 μg L−1, respectively. Although SD is higher by using the standard addition method,
recuperation results are close to 100% when this method is applied to real sample,
according to Table 2.
74
Table 2. Recovery results by standard addition and external calibration methods. (n=3)
This is because all matrix constituents were considered, including any inherent
interference, in quantitation results. For real cachaça samples, water composition may
vary from 38 to 48%. Considering that, Rec was within the acceptable range of 70–
120% according to document SANTE (27). For quantification of the ethyl carbamate in
the actual samples of cachaça, two calibration curves, the external calibration curve
(related to the current recommended procedure) and the stand-ard addition curve (new
methodology), were used to make it possible to compare and validate the proposed
methodology. The retention time of the analyte was 7.727 min, and remained stable
across all different samples, with a variation coefficient equal 0.02% (Figure 5). A
calibration curve with the standard addition was prepared by the linear regression
method. The amount of the analyte in the sample without addition of ethyl carbamate
was calculated from the calibration curve. A correlation coefficient of at least 0.995
generally indicates acceptable characterization of the curve; the proposed method was
capable to obtain excellent linearity, with typical values for the correlation coefficient
(R2) around 0.999 (Figure 6). As shown in Table 3, out of the 18 samples tested, 9
commercial and 9 craft, only one showed an amount of ethyl carbamate above that
allowed by the Brazilian legislation. In addition, we may observe that there is not a
significant error between the measure-ments among commercials brands. Regarding the
craft products, higher values of error were observed between the measurements
presented, which may be related to the method of manufacturing this type of cachaça;
since this is an artisanal product, it may be expected that there is less homogeneity
among the final products. In this way, it is possible to verify that the developed
methodol-ogy could be applied instead of the usual methodology because, despite the
inclusion of sample preparation, it is simple and fast due to the use of QuEChERS.
Standard Addition External Calibration
Day 1* Day 2* ∑ Day 1* Day 2* ∑
Rec (50 ppb) 124% 116% 120% 98% 91% 94%
RSD 3% 9% 7% 0% 2% 4% Rec (100ppb) 104% 106% 105% 81% 84% 83%
RSD 8% 10% 9% 3% 1% 3% Rec (210ppb) 85% 103% 94% 79% 81% 80%
RSD 1% 1% 9% 2% 0% 2%
75
.
Figure 6. Comparison between the standard addition curve (A) and the external
calibration curve (B) for quantification of the ethyl carbamate.
76
Sample MC (ppb) Error (%) FC (ppb)
Comm1 212,4429 0% 53,1107
Comm2 117,1811 0% 29,2953
Comm3 26,8651 2% 6,7163
Comm4 245,4955 2% 61,3739
Comm5 250,6639 1% 62,6660
Comm6 186,6799 2% 46,6700
Comm7 105,0681 0% 26,2670
Comm8 493,4672 6% 123,3668
Comm9 250,0942 0% 62,5236
Craft1 530,7167 3% 132,6792
Craft2 604,5791 5% 151,1448
Craft3 306,7847 1% 76,6962
Craft4 467,9504 29% 116,9876
Craft5 176,5997 5% 44,1499
Craft6 61,9448 1% 15,4862
Craft7 205,4501 17% 51,3625
Craft8 54,0808 2% 13,5202
Craft9 138,3081 1% 34,5770
Table 3. Mean concentration (MC, n=3), absolute error of the measurements (n=3) and
final concentration (FC) of ethyl carbamate in the tested cachaças samples [commercial
(Comm) and craft].
Conclusions
The issue of ethyl carbamate concentration in beverage led to a required
monitoring during manufacturing process and in the final product. Beverage industries
must analyze each production batch to check if it is in accordance with the maximum
allowed limit. In order to control all the production, the method must be easy and robust
as possible. The presence of sucrose in many cachaças makes this task very
complicated, in addition to other matrix components that may interfere in the analysis.
This study presented a simple and effective methodology for identification and
quantification of ethyl carbamate in cachaças, presenting a new approach of QuEChERS
based on the salting-out phenomenon, with leads to minimal sample preparation, and
setup of standard addition method that may be easily prepared by an automatic injector
system. This new methodology showed an increased level of efficacy, with a cost per
analysis of approximately US$ 1.00, which can be considered a cost-effective approach
when compared to the current recommended methodology. In this way, the dem-
onstrated method can be understood as a valid alternative for the identification and
quantification of ethyl carbamate in cachaças.
77
Authors Contributions
TG, KO and ST performed experiments. TG and KO wrote the manuscript and
performed data analysis. CM, DO and EL performed manuscript review. RC idealized
all experiments and managed the research group.
Conflict of interest
The authors Kumi Shiota Ozawa and Simone Pereira do Nascimento Triano were
employed by company Agilent Technologies. All other authors declare no competing
interests of any kind.
Acknowledgments
Innovare Biomarkers Laboratory would like to thank Agilent Technologies for the
technical support and partnership during the experimental process. We also
acknowledge the São Paulo Research Foundation (FAPESP, Process Nos. 11/50400-0
and 15/06809-1 for RRC). We also thank Coordination for the Improvement of Higher
Level Personnel (CAPES) for the fellowships from TMG (PROEX: 1489740), CFORM
(PROEX: 1645986), EOL (PNPD: 1578388) and DNO (88887.137889/2017-00).
References
1. Ministério da Agricultura, P.e.A. Instrução Normativa n° 13, de 29 de Junho de 2005.
Brasília, Brazil: Diário Oficial da União (2005).
2. Cheavegatti-Gianotto A, de Abreu HMC, Arruda P, Bespalhok Filho JC, Burnquist WL,
Creste S, et al. Sugarcane (Saccharum X officinarum): a reference study for the regulation of
genetically modified cultivars in Brazil. Trop Plant Biol (2011) 4(1):62–89.
doi:10.1007/s12042-011-9068-3
3. Campos C, Silva C, Dias D, Basso L, Amorim H, Schwan R. Features of Saccharomyces
cerevisiae as a culture starter for the production of the distilled sugar cane beverage, cachaça in
Brazil. J Appl Microbiol (2010) 108(6):1871–9. doi:10.1111/j.1365-2672.2009.04587.x
4. Riachi L, Santos A, Moreira R, De Maria C. A review of ethyl carbamate and polycyclic
aromatic hydrocarbon contamination risk in cachaça and other Brazilian sugarcane spirits. Food
Chem (2014) 149:159–69. doi:10.1016/j.foodchem.2013.10.088
5. Catão CG, Paes JB, Gomes JP, Araújo GT. Qualidade da madeira de cinco espécies florestais
para o envelhecimento da cachaça. Revista Brasileira de Engenharia Agrícola e Ambiental
(2011) 15(7):741–8. doi:10.1590/S1415-43662011000700013
6. Ministério da Agricultura, P.e.A. Instrução Normativa n° 24, de 8 de setembro de 2005.
(2005).
7. Alcarde AR, Araújo de Souza P, de Souza Belluco AE. Aspectos da composição química e
aceitação sensorial da aguardente de cana-de-açúcar envelhecida em tonéis de diferentes
madeiras. Ciência e Tecnologia de Alimentos (2010) 30(1):226–32. doi:10.1590/S0101-
20612010000500035
8. Baan R, Straif K, Grosse Y, Secretan B, El Ghissassi F, Bouvard V, et al. Carcinogenicity of
alcoholic beverages. Lancet Oncol (2007) 8(4):292. doi:10.1016/S1470-2045(07)70099-2
78
9. Weber J, Sharypov V. Ethyl carbamate in foods and beverages: a review. Environ Chem Lett
(2009) 7(3):233–47. doi:10.1007/s10311-008-0168-8
10. Dennis M, Howarth N, Key P, Pointer M, Massey R. Investigation of ethyl carbamate levels
in some fermented foods and alcoholic beverages. Food Add Contam (1989) 6(3):383–9.
doi:10.1080/02652038909373794
11. Vahl M. A survey of ethyl carbamate in beverages, bread and acidified milks sold in
Denmark. Food Add Contam (1993) 10(5):585–92. doi:10.1080/02652039309374182
12. Beland FA, Benson RW, Mellick PW, Kovatch RM, Roberts DW, Fang J-L, et al. Effect of
ethanol on the tumorigenicity of urethane (ethyl carbamate) in B6C3F 1 mice. Food Chem
Toxicol (2005) 43(1):1–19. doi:10.1016/j.fct.2004.07.018
13. Alexander J, Auounsson G, Benford D, Cockburn A, Cravedi J, Doglitti E. Ethyl carbamate
and hydrocyanic acid in food and beverages. Scientific opinion of the panel on contaminants.
EFSA J (2007) 551:1–44. doi:10.2903/j.efsa.2007.551
14. Chung SW-C, Kwong KP, Chen BL-S. Determination of ethyl carbamate in fermented
foods by GC-HRMS. Chromatographia (2010) 72(5–6):571–5. doi:10.1365/s10337-010-1694-7
15. Rodrigues Neto A, Freitas LSD. Analysis of strategic adaptation process of a sugar cane
brandy company producer under the light of institutional theory and resource-based view. REAd
(2012) 18(1):211–41. doi:10.1590/S1413-23112012000100008
16. Tegmo-Larsson IM, Spittler TD. Temperature and light effects on ethyl carbamate
formation in wine during storage. J Food Sci (1990) 55(4):1166–7. doi:10.1111/j.1365-
2621.1990.tb01624.x
17. Zhao X, Du G, Zou H, Fu J, Zhou J, Chen J. Progress in preventing the accumulation of
ethyl carbamate in alcoholic beverages. Trends in Food Science and Technology (2013)
32(2):97–107. doi:10.1016/j.tifs.2013.05.009
18. de Souza PP, Siebald HGL, Augusti DV, Neto WB, Amorim VM, Catharino RR, et al.
Electrospray ionization mass spectrometry fingerprinting of Brazilian Artisan Cachaça Aged in
different wood casks. J Agric Food Chem (2007) 55(6):2094–102. doi:10.1021/jf062920s
19. de Souza PP, de Oliveira LCA, Catharino RR, Eberlin MN, Augusti DV, Siebald HGL, et
al. Brazilian cachaça: “Single shot” typification of fresh alembic and industrial samples via
electrospray ionization mass spectrometry fingerprinting. Food Chem (2009) 115(3):1064–8.
doi:10.1016/j.foodchem.2008.12.026
20. de Souza PP, Resende AMM, Augusti DV, Badotti F, Gomes FD, Catharino RR, et al.
Artificially-aged cachaça samples characterised by direct infusion electrospray ionisation mass
spectrometry. Food Chem (2014) 143:77–81. doi:10.1016/j.foodchem.2013.07.111
21. dos Santos VR, Faria JB. Efeito Da Adição De Açúcar Na Qualidade Sensorial De Cachaça
Obtida Tradicionalmente E Redestilada. Braz J Food Nutr (2011) 22(3):489–97.
22. Santaladchaiyakit Y, Srijaranai S, Burakham R. Methodological aspects of sample
preparation for the determination of carbamate residues: a review. J Sep Sci (2012)
35(18):2373–89. doi:10.1002/jssc.201200431
23. Nantia EA, Moreno-González D, Manfo FP, Gámiz-Gracia L, García- Campaña AM.
QuEChERS-based method for the determination of carbamate residues in aromatic herbs by
UHPLC-MS/MS. Food Chem (2017) 216:334–41. doi:10.1016/j.foodchem.2016.08.038
24. Alcarde AR, Souza L, Bortoletto A. Ethyl carbamate kinetics in double distillation of sugar
cane spirit. J Inst Brew (2012) 118(1):27–31. doi:10.1002/jib.14
25. Nemati-Kande E, Shekaari H. Salting-out effect of sodium, potassium, carbonate, sulfite,
tartrate and thiosulfate ions on aqueous mixtures of acetonitrile or 1-methyl-2-pyrrolidone: a
liquid–liquid equilibrium study. Fluid Phase Equilib (2013) 360:357–66.
doi:10.1016/j.fluid.2013.09.028
26. Matías J, González J, Royano L, Barrena RA. Analysis of sugars by liquid chromatography-
mass spectrometry in Jerusalem artichoke tubers for bioethanol production optimization.
Biomass Bioenergy (2011) 35(5):2006–12. doi:10.1016/j.biombioe.2011.01.056
27. Dg-sanco E. Guidance Document on Analytical Quality Control and Validation Procedures
for Pesticide Residues Analysis in Food and Feed. Brussels, Belgium: European Commission
(2013). SANCO/12571.
80
5. DISCUSSÃO GERAL
A análise de contaminantes químicos é parte essencial dentro da de segurança
alimentar, visto que tem como objetivos garantir a segurança do consumidor e a
conformidade com os limites estipulados pelos órgãos resuladores. Desta forma, o
desenvolvimento de novas técnicas analíticas capazes de auxiliar na identificação de
contaminantes em alimentos é crucial para que estas substâncias sejam reguladas de
maneira eficiente e concisa, garantindo assim a saúde da população.
Ao analisar os resultados apresentados, temos que a proposta de
desenvolvimento de metodologias capazes de realizar a identificação de contaminantes
presentes em diversas matrizes alimentícias se mostrou satisfatória e eficaz. Através da
combinação de técnicas de MS com a metabolômica foi possível identificar marcadores
químicos responsáveis por diferenciar o grupo de amostras contaminadas do grupo de
amostras sem alterações. Além disso, ao observarmos os resultados presentes nas
análises estatísticas temos que foi possível identificarmos diversos tipos de marcadores
químicos relacionados aos alimentos aqui analisados.
Detalhando especificamente alguns pontos sobre cada um dos temas aqui
estudados, começando com o trabalho de adulterantes no leite, é importante mencionar
que a idéia de um novo enfoque sobre o tema de adulteração de alimentos, baseado nos
efeitos que estes adulterantes podem causar aos nutrientes do leite, foi uma maneira
diferente de se conduzir tal estudo. Temos que dentro dessa temática majoritariamente
observamos trabalhos que tratam exclusivamente da identificação dos adulterantes, sem
pensar nas alterações nutricionais advindas da interação nutriente-adulterante. Além
disso, o uso da análise multivariada PLS-DA foi determinante para seleção das razões
m/z que foram investigadas. Com isso, este trabalho foi importante para destacar uma
frente de estudos singular quando se trata de adulterações em alimentos.
Acerca do trabalho de migração de componentes da embalagem para carne
bovina, temos que os métodos analíticos utilizados para este tipo de análise envolvem o
uso de simulantes de alimentos, que são substâncias que possuem a função de
mimetitizar a composição de um determinado alimento. Apesar destes modelos serem
úteis estes não são capazes de se comportar fielmente como a matriz complexa inerente
de um alimento. Desta forma, para o trabalho aqui apresentado buscamos utilizar
amostras reais de carne vermelha. Para consolidar a metodologia final foram feitos
diversos ensaios previamente para o preparo da amostra, onde foram variados o solvente
orgânico utilizado, o tempo de extração, os volumes empregados e o preparo da carne
81
(se macerada ou em pedaços). Desta forma, temos que o desenvolvimento analítico
neste trabalho foi bastante voltado para elaboração de um preparo de amostra sucinto e
eficaz, de maneira que a análise pudesse ser realizada sem o uso de simulantes. Assim,
conseguimos demonstrar o fenômeno de migração através da HRMS destacando-se aqui
a não necessidade de simulantes, visto que trabalhamos com amostras reais de carne
vermelha, sendo este fato de grande relevância para o campo de análise de alimentos.
Referente ao último trabalho, que tratou da determinação de etil carbamato em
cachaças brasileiras, temos que a problemática que delineou todo o estudo foi a
necessidade de eliminação da interferência da sacarose para este tipo de análise. Grande
parte do desenvolvimento desta metodologia envolveu a busca de alternativas para
contornar este problema e a aplicação do conceito de QuEChERS foi o que nos orientou
para definir a metodologia final. Este trabalho é revolucionário para a área, envolvendo
uma grande contribuição aos pesquisadores de bebidas alcoólicas.
Desta forma, o estudo dos diferentes produtos alimentícios apresentados (leite,
carne vermelha e cachaça) abrange grande parte de processos presentes em atividades
de grande importância no país. Por isso, o desenvolvimento e a implementação de
estratégias metabolômicas simples, seletivas e eficazes foram empregados para auxiliar
na identificação de marcadores de qualidade do leite, identificação de contaminantes de
embalagem em carne vermelha e determinação do contaminante etil carbamato em
cachaças. Desta forma, a alta diversidade e a dinâmica das estratégias metabolômicas
nos permite desenvolver projetos de pesquisa que sejam capazes de ser empregados na
rotina de controle de qualidade de alimentos.
82
6. CONCLUSÃO
Os trabalhos apresentados demonstram que o objetivo proposto foi alcançado
pois as metodologias desenvolvidas apresentam muitas vantagens em relação às técnicas
comumente utilizadas. Algumas dessas vantagens são o mínimo preparo de amostra e o
tempo de análise reduzido. Estas características são relevantes quando pensamos no
ramo da ciência aplicada, que busca solucionar as adversidades analíticas rotineiras.
Deste modo, a identificação eficaz de contaminantes apresentada pelas metodologias
desenvolvidas possibilita seu uso tanto para verificação de fraudes ou adulterações
quanto para verificação da qualidade dos alimentos. Além disso, este tipo de estudos
podem inclusive contribuir para que futuramente laboratórios ou órgãos reguladores
possam empregar tais métodos em sua rotina visando atender às necessidades de
segurança dos consumidores, garantindo assim a saúde e segurança alimentar.
83
7. REFERÊNCIAS
1. Gupta K, Jain V, Jain S, Dhawan K & Talwar G. Analysis of Food. (B. Caballero, Ed.),
Encyclopedia of Food Sciences and Nutrition (Second ed) (2003) (pp 213-222). Oxford:
Elsevier B.V. https://doi.org/http://dx.doi.org/10.1016/B0-12-227055-X/00044-4.
2. Ramos L. Basics and Advances in Sampling and Sample Preparation. In Chemical Analysis
of Food: Techniques and Applications (2012) (pp. 3–24). https://doi.org/10.1016/B978-0-12-
384862-8.00001-7.
3. Fenn JB, Mann M, Meng CK, Wong SF, Whitehouse CM. Electrospray ionization for mass
spectrometry of large biomolecules. Science. 1989 Oct 6;246(4926):64-71.
4. Karas M, Hillenkamp F. Laser desorption ionization of proteins with molecular masses
exceeding 10,000 daltons. Analytical chemistry. 1988 Oct 1;60(20):2299-301.
5. Oms-Oliu G, Odriozola-Serrano I, Martín-Belloso O. Metabolomics for assessing safety and
quality of plant-derived food. Food research international. 2013 Nov 1;54(1):1172-83.
6. Patti GJ, Yanes O, Siuzdak G. Innovation: Metabolomics: the apogee of the omics trilogy.
Nature reviews Molecular cell biology. 2012 Apr;13(4):263.
7. Mazzei P, Piccolo A. 1H HRMAS-NMR metabolomic to assess quality and traceability of
mozzarella cheese from Campania buffalo milk. Food Chemistry. 2012 Jun 1;132(3):1620-7.
8. Marriott NG, Schilling MW, Gravani RB. Food contamination sources. InPrinciples of Food
Sanitation 2018 (pp. 83-91). Springer, Cham.
9. Joint FAO/WHO Expert Committee on Food Additives. Meeting, World Health
Organization. Safety evaluation of certain food additives. World Health Organization; 2006.
10. Robertson LJ, Sprong H, Ortega YR, van der Giessen JW, Fayer R. Impacts of globalisation
on foodborne parasites. Trends in Parasitology. 2014 Jan 1;30(1):37-52.
11. Song Q, Zheng YJ, Xue Y, Sheng WG, Zhao MR. An evolutionary deep neural network for
predicting morbidity of gastrointestinal infections by food contamination. Neurocomputing.
2017 Feb 22;226:16-22.
12. Giacometti J, Tomljanović AB, Josić D. Application of proteomics and metabolomics for
investigation of food toxins. Food research international. 2013 Nov 1;54(1):1042-51.
13. Dervilly‐Pinel G, Courant F, Chéreau S, Royer AL, Boyard‐Kieken F, Antignac JP, Monteau
F, Le Bizec B. Metabolomics in food analysis: application to the control of forbidden
substances. Drug testing and analysis. 2012 Aug;4:59-69.
14. Gallart-Ayala H, Chéreau S, Dervilly-Pinel G, Bizec BL. Potential of mass spectrometry
metabolomics for chemical food safety. Bioanalysis. 2015 Jan;7(1):133-46.
15. Kaddurah-Daouk R, Kristal BS, Weinshilboum RM. Metabolomics: a global biochemical
approach to drug response and disease. Annu. Rev. Pharmacol. Toxicol.. 2008 Feb
10;48:653-83.
16. Mamas M, Dunn WB, Neyses L, Goodacre R. The role of metabolites and metabolomics in
clinically applicable biomarkers of disease. Archives of toxicology. 2011 Jan 1;85(1):5-17.
17. Lei Z, Huhman D, Sumner LW. Mass spectrometry strategies in metabolomics. Journal of
Biological Chemistry. 2011 Jun 1:jbc-R111.
18. Wu H, Xue R, Lu C, Deng C, Liu T, Zeng H, Wang Q, Shen X. Metabolomic study for
diagnostic model of oesophageal cancer using gas chromatography/mass spectrometry.
Journal of Chromatography B. 2009 Oct 1;877(27):3111-7.
19. Van Ravenzwaay B, Herold M, Kamp H, Kapp MD, Fabian E, Looser R, Krennrich G,
Mellert W, Prokoudine A, Strauss V, Walk T. Metabolomics: a tool for early detection of
toxicological effects and an opportunity for biology based grouping of chemicals—from
QSAR to QBAR. Mutation Research/Genetic Toxicology and Environmental Mutagenesis.
2012 Aug 15;746(2):144-50.
20. Glauser G, Veyrat N, Rochat B, Wolfender JL, Turlings TC. Ultra-high pressure liquid
chromatography–mass spectrometry for plant metabolomics: A systematic comparison of
high-resolution quadrupole-time-of-flight and single stage Orbitrap mass spectrometers.
Journal of Chromatography A. 2013 May 31;1292:151-9.
21. Orešič M. Metabolomics, a novel tool for studies of nutrition, metabolism and lipid
dysfunction. Nutrition, Metabolism and Cardiovascular Diseases. 2009 Dec 1;19(11):816-24.
84
22. Vivian AF, Aoyagui CT, de Oliveira DN, Catharino RR. Mass spectrometry for the
characterization of brewing process. Food Research International. 2016 Nov 1;89:281-8.
23. De Oliveira DN, de Bona Sartor S, Ferreira MS, Catharino RR. Cosmetic analysis using
matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI).
Materials. 2013 Mar 13;6(3):1000-10.
24. Scalbert A, Brennan L, Fiehn O, Hankemeier T, Kristal BS, van Ommen B, Pujos-Guillot E,
Verheij E, Wishart D, Wopereis S. Mass-spectrometry-based metabolomics: limitations and
recommendations for future progress with particular focus on nutrition research.
Metabolomics. 2009 Dec 1;5(4):435.
25. Dragsted LO. Biomarkers of meat intake and the application of nutrigenomics. Meat science.
2010 Feb 1;84(2):301-7.
26. Cajka T, Fiehn O. Toward merging untargeted and targeted methods in mass spectrometry-
based metabolomics and lipidomics. Analytical chemistry. 2015 Dec 16;88(1):524-45.
27. Cevallos-Cevallos JM, Reyes-De-Corcuera JI. Metabolomics in food science. InAdvances in
food and nutrition research 2012 Jan 1 (Vol. 67, pp. 1-24). Academic Press.
28. Cubero-Leon E, Peñalver R, Maquet A. Review on metabolomics for food authentication.
Food Research International. 2014 Jun 1;60:95-107.
29. Scalbert A, Brennan L, Manach C, Andres-Lacueva C, Dragsted LO, Draper J, Rappaport
SM, van der Hooft JJ, Wishart DS. The food metabolome: a window over dietary exposure–.
The American journal of clinical nutrition. 2014 Apr 23;99(6):1286-308.
30. Cifuentes A. Food analysis: present, future, and foodomics. ISRN Analytical Chemistry.
2012 Nov 26;2012.
31. González-Curbelo MÁ, Socas-Rodríguez B, Herrera-Herrera AV, González-Sálamo J,
Hernández-Borges J, Rodríguez-Delgado MÁ. Evolution and applications of the QuEChERS
method. TrAC Trends in Analytical Chemistry. 2015 Sep 1;71:169-85.
32. Guerreiro TM, Ozawa KS, Lima ED, Melo CF, de Oliveira DN, Triano SP, Catharino RR.
New Approach of QuEChERS and GC-MS Triple-Quadrupole for the Determination of
Ethyl Carbamate Content in Brazilian cachaças. Frontiers in nutrition. 2018 Apr 6;5:21.
33. Koesukwiwat U, Sanguankaew K, Leepipatpiboon N. Evaluation of a modified QuEChERS
method for analysis of mycotoxins in rice. Food chemistry. 2014 Jun 15;153:44-51.
34. Keshet U, Alon T, Fialkov AB, Amirav A. Open Probe fast GC–MS—combining ambient
sampling ultra‐fast separation and in‐vacuum ionization for real‐time analysis. Journal of
Mass Spectrometry. 2017 Jul;52(7):417-26.
35. Harris DC. Quantitative chemical analysis. Macmillan; 2010 Apr 30.
36. Hu YL, Chen ZP, Chen Y, Shi CX, Yu RQ. Generalized multiple internal standard method
for quantitative liquid chromatography mass spectrometry. Journal of Chromatography A.
2016 May 6;1445:112-7.
37. Giorgi G. Mass Spectrometry and High Resolution Mass Spectrometry: An Overview.
InMolecular Technologies for Detection of Chemical and Biological Agents 2017 (pp. 89-
101). Springer, Dordrecht.
38. Wishart DS. Metabolomics: applications to food science and nutrition research. Trends in
Food Science & Technology. 2008 Sep 1;19(9):482-93.
39. Gross JH. Mass spectrometry: a textbook. Springer Science & Business Media; 2006 Sep 21.
40. Griffiths J. A brief history of mass spectrometry. Anal Chem. 2008 Aug 1;80(15):5678-83.
41. Konermann L, Ahadi E, Rodriguez AD, Vahidi S. Unraveling the mechanism of electrospray
ionization. 2012: 2-9
42. Cech NB, Enke CG. Practical implications of some recent studies in electrospray ionization
fundamentals. Mass spectrometry reviews. 2001;20(6):362-87.
43. Giorgi G. Mass Spectrometry and Tandem Mass Spectrometry: An Overview. InDetection of
Chemical, Biological, Radiological and Nuclear Agents for the Prevention of Terrorism 2014
(pp. 17-31). Springer, Dordrecht.
44. Bosco GL. The development of LC-MS–the marriage of the bird and the fish. TrAC Trends
in Analytical Chemistry. 2010 Sep 1;29(8):781-94.
45. Huang CH, Sedlak DL. Analysis of estrogenic hormones in municipal wastewater effluent
and surface water using enzyme‐linked immunosorbent assay and gas
85
chromatography/tandem mass spectrometry. Environmental Toxicology and Chemistry: An
International Journal. 2001 Jan;20(1):133-9.
46. Tranchida PQ, Franchina FA, Zoccali M, Pantò S, Sciarrone D, Dugo P, Mondello L.
Untargeted and targeted comprehensive two-dimensional GC analysis using a novel unified
high-speed triple quadrupole mass spectrometer. Journal of Chromatography A. 2013 Feb
22;1278:153-9.
47. Picotti P, Aebersold R. Selected reaction monitoring–based proteomics: workflows,
potential, pitfalls and future directions. Nature methods. 2012 Jun;9(6):555.
48. Yao X, McShane AJ, Castillo MJ. Quantitative Proteomics in Development of Disease
Protein Biomarkers. InProteomic and Metabolomic Approaches to Biomarker Discovery
2013 (pp. 259-278).
49. Yao X, Bajrami B, Shi Y. Ultrathroughput multiple reaction monitoring mass spectrometry.
Analytical chemistry. 2010 Jan 11;82(3):794-7.
50. Cooper HJ, Marshall AG. Electrospray ionization Fourier transform mass spectrometric
analysis of wine. Journal of Agricultural and Food Chemistry. 2001 Dec 17;49(12):5710-8.
51. Pereira PC. Milk nutritional composition and its role in human health. Nutrition. 2014 Jun
1;30(6):619-27.
52. United States Department of Agriculture (USDA). Dairy: World Markets and Trade. Foreign
Agricultural Service/Office of Global Analysis, 2017. Retrieved from
https://apps.fas.usda.gov/psdonline/circulars/dairy.pdf
53. Fox PF, Guinee TP, Cogan TM, McSweeney PL. Overview of cheese manufacture.
InFundamentals of cheese science 2017 (pp. 11-25). Springer, Boston, MA.
54. Walstra P, Geurts TJ, Noomen A, Jellema A & van Boekel MAJS. Principles of Milk
Properties and Processes in Dairy science and technology. CRC press; 2005 Sep 29.
55. Martin NH, Ranieri ML, Murphy SC, Ralyea RD, Wiedmann M, Boor KJ. Results from raw
milk microbiological tests do not predict the shelf-life performance of commercially
pasteurized fluid milk. Journal of dairy science. 2011 Mar 1;94(3):1211-22.
56. McAllister AJ. Is Crossbreeding the Answer to Questions of Dairy Breed Utilization? 1.
Journal of Dairy Science. 2002 Sep 1;85(9):2352-7.
57. Schnier C, Hielm S, Saloniemi HS. Comparison of the breeding performance of cows in cold
and warm loose-housing systems in Finland. Preventive veterinary medicine. 2004 Feb
26;62(2):135-51.
58. Dash S, Chakravarty AK, Singh A, Upadhyay A, Singh M, Yousuf S. Effect of heat stress on
reproductive performances of dairy cattle and buffaloes: A review. Veterinary world. 2016
Mar;9(3):235.
59. West JW, Mullinix BG, Bernard JK. Effects of hot, humid weather on milk temperature, dry
matter intake, and milk yield of lactating dairy cows. Journal of Dairy Science. 2003 Jan
1;86(1):232-42.
60. Teodoro RL, Madalena FE. Evaluation of crosses of Holstein, Jersey or Brown Swiss sires x
Holstein-Friesian/Gir dams. 3. Lifetime performance and economic evaluation. Genetics and
Molecular Research. 2005 Mar 31;4(1):84-93.
61. Khan MS, Shook GE. Effects of age on milk yield: Time trends and method of adjustment.
Journal of dairy science. 1996 Jun 1;79(6):1057-64.
62. Jenkins TC, McGuire MA. Major advances in nutrition: impact on milk composition. Journal
of Dairy Science. 2006 Apr 1;89(4):1302-10.
63. Beckman JL, Weiss WP. Nutrient digestibility of diets with different fiber to starch ratios
when fed to lactating dairy cows. Journal of Dairy Science. 2005 Mar 1;88(3):1015-23.
64. Tolkamp BJ, Friggens NC, Emmans GC, Kyriazakis I, Oldham JD. Meal patterns of dairy
cows consuming mixed foods with a high or a low ratio of concentrate to grass silage.
Animal Science. 2002 Apr;74(2):369-82.
65. Ministério da Agricultura Pecuária e Abastecimento (MAPA). Mapa e Embrapa
desenvolvem sistema que qualifica políticas públicas para o leite. (2016). Retrieved from
http://www.agricultura.gov.br/noticias/mapa-e-embrapa-desenvolvem-sistema-que-qualifica-
politicas-publicas-para-o-leite
86
66. European Commission. (2006a). Regulation (EC) No 509/2006. Official Journal of the
European Union, L93, 1.
67. European Commission. (2006b). Regulation (EC) No 510/2006. Offical Journal of the
European Union, L93, 12.
68. Nascimento CF, Santos PM, Pereira-Filho ER, Rocha FR. Recent advances on determination
of milk adulterants. Food chemistry. 2017 Apr 15;221:1232-44.
69. Jeong HS, Chung H, Song SH, Kim CI, Lee JG, Kim YS. Validation and determination of
the contents of acetaldehyde and formaldehyde in foods. Toxicological research. 2015
Sep;31(3):273.
70. Guerreiro TM, de Oliveira DN, Ferreira MS, Catharino RR. High-throughput analysis by SP-
LDI-MS for fast identification of adulterations in commercial balsamic vinegars. Analytica
chimica acta. 2014 Aug 1;838:86-92.
71. Riccio MF, Sawaya AC, Abdelnur PV, Saraiva SA, Haddad R, Eberlin MN, Catharino RR.
Easy ambient sonic-spray ionization mass spectrometric of olive oils: quality control and
certification of geographical origin. Analytical Letters. 2011 May 1;44(8):1489-97.
72. IBGE. Censo Agropecuário 2006. IBGE - Instituto Brasileiro de Geografia E Estatística,
777. 2009. Retrieved from https://doi.org/0103-6157
73. Brazilian Association of Meat Exporters. Report of Brazilian Beef Exports - Jan/2017 -
Dez/2017. Retrieved from http://www.abiec.com.br/download/Anual-jan-dez-2017.pdf
74. Fasano E, Bono-Blay F, Cirillo T, Montuori P, Lacorte S. Migration of phthalates,
alkylphenols, bisphenol A and di (2-ethylhexyl) adipate from food packaging. Food Control.
2012 Sep 1;27(1):132-8.
75. Wagner M, Oehlmann J. Endocrine disruptors in bottled mineral water: estrogenic activity in
the E-Screen. The Journal of steroid biochemistry and molecular biology. 2011 Oct 1;127(1-
2):128-35.
76. European Commission. (2004). Regulation (EC) No 1935/2004. Official Jurnal of the
European Union, L338/4(1935), 4–17.
77. European Commission. (2011). Commission Regulation (EU) No 10/2011 on plastic
materials and articles intended to come into contact with food. Offical Journal of the
European Union, 15(1), 12–88. https://doi.org/10.1016/j.nucengdes.2011.01.052
78. Ribeiro‐Santos R, de Melo NR, Andrade M, Sanches‐Silva A. Potential of migration of
active compounds from protein‐based films with essential oils to a food and a food simulant.
Packaging Technology and Science. 2017 Dec;30(12):791-8.
79. Agência Nacional de Vigilância Sanitária (ANVISA). Resolução da Diretoria Colegiada –
RDC no 56, de 16 de novembro de 2012. Diário Oficial Da União, 57. 2012. Retrieved from
http://file.abiplast.org.br/download/2017/Res-RDC56_16novembro2012.pdf
80. De Oliveira DN, Catharino RR. Direct metabolic fingerprinting of olive oils using STELDI-
MS. Journal of Food Composition and Analysis. 2015 Mar 1;38:131-4.
81. Ministério da Agricultura, Pecuária e Abasteciemnto. (2005a) Instrução Normativa n° 13, de
29 de Junho de 2005. Brasília, Brazil: Diário Oficial da União
82. Andrade LAB. Cultura da cana-de-açúcar. In: Cardoso MG. Produção de aguardente de
cana. 3. ed. ampl. e revis. Lavras: Editora UFLA, 2013. p. 26-56.
83. Campos CR, Silva CF, Dias DR, Basso LC, Amorim HV, Schwan RF. Features of
Saccharomyces cerevisiae as a culture starter for the production of the distilled sugar cane
beverage, cachaça in Brazil. Journal of applied microbiology. 2010 Jun;108(6):1871-9.
84. Catão CG, Paes JB, Gomes JP, Araújo GT. Qualidade da madeira de cinco espécies
florestais para o envelhecimento da cachaça. Revista Brasileira de Engenharia Agricola e
Ambiental-Agriambi. 2011 Jul 1;15(7).
85. Ministério da Agricultura, Pecuária e Abasteciemnto. (2005b) Instrução Normativa n° 24, de
8 de Setembro de 2005. Brasília, Brazil: Diário Oficial da União
86. Alcarde AR, Souza PA, Belluco AE. Aspectos da composição química e aceitação sensorial
da aguardente de cana-de-açúcar envelhecida em tonéis de diferentes madeiras. Ciência e
Tecnologia de Alimentos. 2010;30(suppl 1):226-32.
87. Baan R, Straif K, Grosse Y, Secretan B, El Ghissassi F, Bouvard V, Altieri A, Cogliano V.
Carcinogenicity of alcoholic beverages. The lancet oncology. 2007 Apr 1;8(4):292-3.
87
88. Weber JV, Sharypov VI. Ethyl carbamate in foods and beverages–a review. InClimate
change, intercropping, pest control and beneficial microorganisms 2009 (pp. 429-452).
Springer, Dordrecht.
89. European Food Safety Authority (EFSA). Ethyl carbamate and hydrocyanic acid in food and
beverages‐Scientific Opinion of the Panel on Contaminants. EFSA Journal. 2007
Oct;5(10):551.
90. Rodrigues Neto A & Freitas LSD. Analysis of strategic adaptation process of a sugar cane
brandy company producer under the light of institutional theory and resource-based view.
(2012) REAd 18(1):211–41.
91. Tegmo‐Larsson IM, Spittler TD. Temperature and light effects on ethyl carbamate formation
in wine during storage. Journal of Food Science. 1990 Jul;55(4):1166-7.
92. Dyer RH. Determination of ethyl carbamate (urethane) in alcoholic beverages using capillary
gas chromatography with thermal energy analyzer detection: Collaborative study. Journal of
AOAC International (USA). 1994.
93. de Souza PP, Resende AM, Augusti DV, Badotti F, Fátima de Cássia OG, Catharino RR,
Eberlin MN, Augusti R. Artificially-aged cachaça samples characterised by direct infusion
electrospray ionisation mass spectrometry. Food chemistry. 2014 Jan 15;143:77-81.
94. de Souza PP, de Oliveira LC, Catharino RR, Eberlin MN, Augusti DV, Siebald HG, Augusti
R. Brazilian cachaça:“Single shot” typification of fresh alembic and industrial samples via
electrospray ionization mass spectrometry fingerprinting. Food Chemistry. 2009 Aug
1;115(3):1064-8.
95. de Souza PP, Siebald HG, Augusti DV, Neto WB, Amorim VM, Catharino RR, Eberlin MN,
Augusti R. Electrospray ionization mass spectrometry fingerprinting of Brazilian artisan
cachaca aged in different wood casks. Journal of agricultural and food chemistry. 2007 Mar
21;55(6):2094-102.
96. dos Santos VR & Faria JB. Efeito da adição de açúcar na qualidade sensorial de cachaça
obtida tradicionalmente e redestilada. Brazilian Journal of Food & Nutrition/Alimentos e
Nutrição. 2011 Sep 1;22(3).
97. Santaladchaiyakit Y, Srijaranai S, Burakham R. Methodological aspects of sample
preparation for the determination of carbamate residues: a review. Journal of separation
science. 2012 Sep;35(18):2373-89.
98. Nantia EA, Moreno-González D, Manfo FP, Gámiz-Gracia L, García-Campaña AM.
QuEChERS-based method for the determination of carbamate residues in aromatic herbs by
UHPLC-MS/MS. Food chemistry. 2017 Feb 1;216:334-41.
99. Xia J, Sinelnikov IV, Han B, Wishart DS. MetaboAnalyst 3.0—making metabolomics more
meaningful. Nucleic acids research. 2015 Apr 20;43(W1):W251-7.
100. Guerreiro TM, de Oliveira DN, Melo CF, de Oliveira Lima E, da Silva Ribeiro M, Catharino
RR. Evaluating the effects of the adulterants in milk using direct-infusion high-resolution
mass spectrometry. Food Research International. 2018 Jun 1;108:498-504.
101. Guerreiro TM, de Oliveira DN, Melo CF, de Oliveira Lima E, Catharino RR. Migration from
plastic packaging into meat. Food Research International. 2018 Jul 1;109:320-4.)
88
8. ANEXOS
Os documentos anexados a seguir são referentes à permissão/autorização do uso
dos trabalhos publicados junto às respectivas editoras para a inclusão dos artigos
apresentados nesta tese, em atendimento à legislação que rege o direito autoral.
Conforme apresentado nos documentos a seguir não é necessária permissão para o uso
dos artigos, apenas que os trabalhos sejam citado de acordo, conforme consta na seção
7. Referências.
8.1 Autorização de uso – Artigo do Leite
89
8.2 Autorização de uso – Artigo da Carne
90
8.3 Autorização de uso – Artigo da Cachaça