7/28/2019 BPVC-VIII-2 Interpretação Vol.58 2007 http://slidepdf.com/reader/full/bpvc-viii-2-interpretacao-vol58-2007 1/3 SECTION VIII-2 Subject Interpretation File No. AD-160 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VIII-2-07-02 07-1016 AF-110 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VIII-2-01-17 02-2792 AG-121 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VIII-2-07-01 06-1272 AM-211, Fig. AM-211. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VIII-2-04-12 03-1651

Upload: lsinsp3381

Post on 03-Apr-2018

222 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BPVC-VIII-2 Interpretação Vol.58 2007

7/28/2019 BPVC-VIII-2 Interpretação Vol.58 2007

http://slidepdf.com/reader/full/bpvc-viii-2-interpretacao-vol58-2007 1/3

SECTION VIII-2

Subject Interpretation File No.

AD-160 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VIII-2-07-02 07-1016

AF-110 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VIII-2-01-17 02-2792

AG-121 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VIII-2-07-01 06-1272

AM-211, Fig. AM-211. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VIII-2-04-12 03-1651

Page 2: BPVC-VIII-2 Interpretação Vol.58 2007

7/28/2019 BPVC-VIII-2 Interpretação Vol.58 2007

http://slidepdf.com/reader/full/bpvc-viii-2-interpretacao-vol58-2007 2/3

Interpretation: VIII-2-01-17

Subject: Section VIII, Division 2 (2001 Edition), AF-110

Date Issued: April 24, 2003File: 02-2792

Question: In meeting the requirements of UG-79 of Section VIII, Division 1 and AF-111 of Section VIII,

Division 2, is the use of heat or flame permitted to correct the shape of pressure parts, provided the use of 

these techniques does not impair the physical properties of the material?

Reply: Yes.

Note: This interpretation was inadvertently omitted from Vol. 53 of the interpretations. It also appears as

VIII-1-01-157.

Interpretation: VIII-2-04-12

Subject: Section VIII, Division 2 (2001 Edition, 2002 Addenda), AM-211, Fig. AM-211

Date Issued: February 24, 2005

File: 03-1651

Question: Is it the intent to allow the rounding to the nearest whole number of the average value of the

three impact test specimens as required by UG-84(c) and Fig. UG-84.1?

Reply: Yes.

Note: This interpretation was inadvertently omitted from Vol. 56 of the interpretations.

Interpretation: VIII-2-07-01

Subject: Section VIII, Divisions 1 and 2 (2004 Edition, 2006 Addenda), AG-121

Date Issued: February 6, 2007

File: 06-1272

Question: Is it prohibited by the rules of Section VIII, Division 1 or 2 for a vessel to be constructed to

the rules of either Division 1 or 2 that is used to contain a gas that is heated by use of a nuclear fuel?

Reply: No. However, see U-1(c)(1) or footnote 1 of AG-100.

Note: This interpretation also appears as VIII-1-07-19.

Page 3: BPVC-VIII-2 Interpretação Vol.58 2007

7/28/2019 BPVC-VIII-2 Interpretação Vol.58 2007

http://slidepdf.com/reader/full/bpvc-viii-2-interpretacao-vol58-2007 3/3

Interpretation: VIII-2-07-02

Subject: Section VIII, Division 2 (2004 Edition, 2006 Addenda), AD-160

Date Issued: June 21, 2007File: 07-1016

Question: If the expected range of operating pressure variations does not exceed 20% of the design pressure

when using AD-160.2 and 15% of the design pressure when using AD-160.3, may these pressure cycles be

neglected when evaluating the exemption from fatigue analysis even though the number of cycles may be

much greater than 106?

Reply: Yes.