1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 a 420 [16.5] 411 [16.2]files.danfoss.com/download/drives/mcad...
Post on 05-Aug-2020
4 Views
Preview:
TRANSCRIPT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
A
B
C
D
E
F
G
H
J
K
L
M
B
C
D
E
F
G
H
J
K
L
M
A
CRITICAL CHARACTERISTICSKEY CHARATERISTICSINSPECTIONMUST COMPLY TO ROHS DIRECTIVE 2011/65/EU
223688[ ]
251[ ]
230.9[ ]
1566.2[ ]
41116.2[ ]
42016.5[ ]
228489.9[ ]
MIN. AIRSPACEOUTLET
225 8.9[ ]
140.6[ ]
251[ ]
2359.3[ ]
38515.2[ ]4X 11
0.4[ ]
206581.3[ ]
1305.1[ ]
32012.6[ ]
1074.2[ ]
2138.4[ ]
1305.1[ ]
97338.3[ ]
1074.2[ ]
2138.4[ ]
32012.6[ ]
39615.6[ ]
251[ ]
230.9[ ]
722.8[ ]
37414.7[ ]
28011[ ]
225988.9[ ]
1626.4[ ]
140055.1[ ]
2158.5[ ]
702.8[ ]
169966.9[ ]
40616[ ]
52420.6[ ]
105�$�
147358[ ]
59123.3[ ]
31612[ ]
1 OF 6P454-1042
CONFIDENTIAL: PROPERTY OF DANFOSS A/S NORDBORG, DENMARK. NOT TO BE HANDED OVER TO BE COPIED OR BE USED BY A THIRD PARTY. TWO OR THREE DIMENSIONAL REPRODUCTION OF CONTENTS TO BE AUTHORIZED BY DANFOSS A/S.
SHEETMODEL002177R0493
REVDRAWING NUMBER
INSTALLATION DRAWING, D8H, IP21/54
CHECKED
03/28/12NDDESIGNED
08/24/16BCCHANGED
NOT VALID WITHOUT FROZEN DATE IN ID STAMP
DESCRIPTION
N/AFINISHA10.125
INTERPRET DIM. & TOL. PER ASME Y14.5M-1994ALL DIMENSIONS ARE IN MILLIMETERS
TOLERANCES UNLESS OTHERWISE SPECIFIED.X�#�1.0 .XX�#�0.50 �a��#�1.0
N/AMATERIALSIZESCALETHIRD ANGLE PROJECTION
1. MAX AIRFLOW (BACKCHANNEL) - 14 M³ / MIN (500 CFM)2. MAX AIRFLOW (CABINET) - 3.4 M³ / MIN (120 CFM)3. MAX WEIGHT = 232 KG (512 LBS)4. CENTER OF GRAVITY: APPROXIMATE LOCATION ONLY, LOCATION MAY VARY BASED ON POWER RATING AND OPTIONS ORDERED.
HEATSINK ACCESSPANEL
SEE DETAIL A CEILING
BOTTOM MOUNTING HOLES
DETAIL ATOP MOUNTING HOLES
USE M10 MTG BOLT OR3/8" MTG BOLT
002
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
A
B
C
D
E
F
G
H
J
K
L
M
B
C
D
E
F
G
H
J
K
L
M
A
69 2.7
[]
00
[]
1234.9
[]
1777
[]
2389.4
[]
29211.5
[]
34613.6
[]
49 1.9
[]
37814.9
[]
1987.8
[]
GROUND 3X 38815.3[ ]
00[ ]
GROUND 42816.9[ ]
89835.3[ ]
40115.8[ ]
52120.5[ ]
33713.3[ ]
1696.6[ ]
2228.7[ ]
1124.4[ ]
431.7[ ]
95 3.7
[]
1515.9
[]
180.7[ ]
140.5[ ]
200.8[ ]
351.4[ ]
160.6[ ]
321.3[ ]
150.6[ ]
150.6[ ]
200.8[ ]
301.2[ ]
1194.7
[]
00
[]
2529.9
[]
1275
[]
00
[]
2 OF 6P454-1042SHEETMODEL
002177R0493REVDRAWING NUMBER
MAINS TERMINAL
BRAKE / REGEN TERMINAL
NOTES: 1. PLACE CABLES THROUGH MARKED AREAS2. 185MM² (400 MCM) MAX WIRE SIZE
MAINS TERMINAL
CONTACTOR ONLY
R
S
T
U
V
W
MOTOR TERMINAL
4X M10X20 STUDWITH NUT
SECTION A-AMAINS TERMINALs
BRAKE/REGEN TERMINALS
SECTION B-BMOTOR TERMINALS
BOTTOM VIEW
MOTOR SIDE CABLE ENTRY
MAINS SIDECABLE ENTRY
BRAKE TERMINAL
M10
MOTOR TERMINAL
M10M10 NUT AND BOLT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
A
B
C
D
E
F
G
H
J
K
L
M
B
C
D
E
F
G
H
J
K
L
M
A
56722.3[ ]
00[ ]
58 2.3
[]
00
[]
1234.9
[]
1887.4
[]
230.9[ ]
19.50.8[ ]
391.5[ ]
66926.3[ ]
00[ ]
2469.7
[]
00
[]
25610.1
[]
00
[]
3 OF 6P454-1042SHEETMODEL
002177R0493REVDRAWING NUMBER
MAINS TERMINAL
CONTACTOR AND DISCONNECT
MAINS TERMINAL
NOTES: 1. REFER SHEET 2 FOR BRAKE AND MOTOR TERMINAL DEAILS
R
S
T
SECTION C-CMAINS TERMINALS
M10 NUT AND BOLT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
A
B
C
D
E
F
G
H
J
K
L
M
B
C
D
E
F
G
H
J
K
L
M
A
76730.2[ ]
00[ ]
00
[]
85 3.3
[]
00
[]
1556.1
[]
2258.8
[]
00[ ]
55121.7[ ]
2128.3
[]
1124.4
[]
00
[]
200.8[ ]
401.6[ ]
150.6[ ]
4 OF 6P454-1042SHEETMODEL
002177R0493REVDRAWING NUMBER
MAINS TERMINAL
CIRCUIT BREAKER
NOTES: 1. REFER SHEET 2 FOR BRAKE AND MOTOR TERMINAL DEAILS
R
S
T
SECTION D-DMAINS TERMINALS
MAINS TERMINALSCALE 1.000
M10
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
A
B
C
D
E
F
G
H
J
K
L
M
B
C
D
E
F
G
H
J
K
L
M
A
5 OF 6P454-1042SHEETMODEL
002177R0493REVDRAWING NUMBER
NOTES: 1) GLAND PLATE MUST BE INSTALLED BEFORE PEDESTAL 2) SEE PAGE 1 FOR FLOOR MOUNTING DIMENSIONS
PEDESTAL INSTALLATION
SEE DETAIL B
SEE DETAIL C
DETAIL BSCALE 0.400
USE (4) 681X9143 M5 SCREWS THROUGH FRONT PEDESTAL FLANGE INTO FRONT
GLAND PLATE MOUNTING HOLES
USE (2) 681X9143 M5 SCREWS THROUGH BACK PEDESTAL FLANGE INTO PEDESTAL DRIVE MOUNTING BRACKET
USE (2) 26516 M10 NUTS TO ATTACH PEDESTAL TO BRIVE BACK CHANNEL
DETAIL CSCALE 0.400
SLIDE PEDESTAL WALL SPACER BEHIND TOP DRIVE MOUNTING FLANGE BEFORE
ATTACHING ENCLOSURE TO WALL
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
A
B
C
D
E
F
G
H
J
K
L
M
B
C
D
E
F
G
H
J
K
L
M
A
690V D8H D8H D8H D8H
525V D8H D8H D8H D8H
500V D8H D8H D8H
400V D8H D8H D8H
KW NORMAL OVERLOAD
160 200 250 315 355 400
KW HIGH OVERLOAD
132 160 200 250 315 315
KW RATED DRIVES
575V D8H D8H D8H D8H
460V D8H D8H D8H
HP NORMAL OVERLOAD
250 300 350 400 450
HP HIGH OVERLOAD
200 250 300 350 350
HORSEPOWER RATED DRIVES
PLATFORM VOLTAGE MODEL/TYPECODE FRAME(IP21/IP54)
HVAC
T4
FC-102N200T4
D8H
FC-102N250T4
FC-102N315T4
T7
FC-102N200T7
FC-102N250T7
FC-102N315T7
FC-102N400T7
AQUA
T4
FC-202N200T4
FC-202N250T4
FC-202N315T4
T7
FC-202N200T7
FC-202N250T7
FC-202N315T7
FC-202N400T7
AUTOMATION
T5
FC-302N160T5
FC-302N200T5
FC-302N250T5
T7
FC-302N160T7
FC-302N200T7
FC-302N250T7
FC-302N315T7
6 OF 6P454-1042SHEETMODEL
002177R0493REVDRAWING NUMBER
THE TABLES BELOW ARE USED TO DETERMINE THE FRAME SIZE FOR A GIVEN POWER AND VOLTAGE RATING, WITH A CIRCUIT BREAKER, CONTACTOR OR DISCONNECT + CONTACTOR.1) IDENTIFY THE POWER IN NORMAL OVERLOAD (N.O.) OR HIGH OVERLOAD (H.O.), KILOWATTS (KW) OR HORSEPOWER (HP). 2) READ DOWN THE COLUMN TO THE ROW WITH THE CORRECT VOLTAGE TO IDENTIFY THE FRAME SIZE.THIS DRAWING IS FOR D8H FRAMES,
THE TABLE BELOW CAN BE USED TO DETERMINE THE FRAME SIZE IF THE SPECIFIC MODEL/TYPE CODE WITH A CIRCUIT BREAKER, CONTACTOR OR DISCONNECT + CONTACTOR IS KNOWN.
top related