CISTERNA
ABRIGO DE GÁSLIXO
TQ-4
100 mm
TQ-1
100 mm
TQ-2
100 mm
CE
S1
CG
PVC
CE
S2
100 m
m
CE
CV-5
50 mm
i=1%
PVC 100 mm
S4
CE CE
i=1%
PVC 100 mm
i=1%
PVC 100 mm
i=1%
PVC 100 mm
i=
1%
PV
C100 m
m
i=1%
PVC 100 mm
CE
i=1%
PVC 100 mm
CE
S3
CG
PVC
CV-6
50 mm
TQ-5
100 mm
TQ-6
75 mm
AP-1
100 mm
AP-2
100 mm
AP-5
100 mm
AP-6
100 mm
TQ-3
100 mm
75 mm
i=
1%
100 m
m
CX. AR
CX. ARCX. AR
CX. AR
i=
1%
PV
C100 m
m
CX. AR
i=
1%
100 m
m
i=1%
150 mm
1
0
0
m
m
i=1%
PVC 100 mm
i
=
1
%
1
0
0
m
m
i=1%
PVC 100 mm
i=
1%
100 m
m
i=1%
PVC 100 mm
i=1%
PVC 100 mm
i=1%
PVC 100 mm
i=1%
PVC 100 mm
i
=
1
%
1
0
0
m
m
AP-4
100 mm
TQ-7
75 mm
i=1%
100 mm
i=
1%
100 m
m
i=
1%
50 m
m
i=
1%
PV
C100 m
m
i
=
1
%
5
0
m
m
i=
1%
50 m
m
i
=
1
%5
0
m
m
i=1%
PVC 100 mm
i=
1%
100 m
m
50 mm
SEGUE PARA REDE
COLETORA DE
ESGOTO CASAN
SEGUE PARA REDE
PLUVIAL DO BAIRRO
CF=-34.94
CT=7.00
CF=-64.94
CT=-23.00
CF=-54.94
CT=-13.00
CF=-63.64
CT=-13.00
CF=-82.14
CT=-22.50
CF=-70.56
CT=-13.00
CF=-89.64
CT=3.00
CF=-55.64
CT=-10.00
CF=-41.09
CT=7.00
CF=-34.94
CT=7.00
CF=-34.94
CT=7.00
CF=-36.64
CT=7.00
CF=-40.64
CT=7.00
CF=-95.11
CT=-53.17
i=1%
100 mm
-165.00
DETALHE CISTERNA
CE
i=
1%
PV
C100 m
m
i=2%
CF=-100.27
CT=-58.33
F1
F2
F3
F4
F5
F6
F7F8
F9
F10
TQ-1
ø100
TQ-2
ø100
CE
ø50
i=
2%
ø
5
0
i
=
2
%
ø
5
0
i
=
2
%
ø50
ø40
i=
2%
ø
4
0
i
=
2
%
ø
1
0
0
i
=
1
%
ø100
i=
1%
ø
1
0
0
i
=
1
%
ø100
i=1%
AP-5
ø100 ø100
i=
1%
ø
1
0
0
i
=
1
%
56 2451
CG
PVC
CE
ø50
i=
2%
ø50
i=2%
ø100
i=
1%
ø100
i=1%
ø100
i=1%
ø100
i=1%
156 132160
CE
ø
1
0
0
i
=
1
%
ø100
i=
1%
ø50
i=
2%
ø100
i=
1%
ø
5
0
i
=
2
%
ø
4
0
i
=
2
%
ø100
ø100
i=1%
ø100
i=1%
CV-6
ø50
ø50
i=
2%
ø50
i=
1%
TQ-6
ø75
AP-6
ø100
TQ-3
ø100
ø100
ø75
ø100
i=
1%
ø
7
5
i
=
2
%
ø100
i=
1%
75
12
31
14
57
30
168
AR
QU
IV
O:
DESENHO Nº:
/
PRANCHA:
DESENHISTA:DATA:
LOCALIZAÇÃO:
ESCALA:
PROPRIETÁRIO:RESPONSÁVEL TÉCNICO:
PROJETO:
PROJETO
RESPONSÁVEL TÉCNICO:
EXECUÇÃO
CPF: 375.976.399-53
PROJETO HIDROSSANITÁRIO
RODOVIA CALIL BULOS (SC-403), S/N - CONDOMÍNIO JARDIM INGLESES II, ÁREA N 07 - FLORIANÓPOLIS
EDIFICAÇÃO RESIDENCIAL
TÉRREO
PLANTA BAIXA E DETALHE ISOMÉTRICO S1, S2 E S4
INDICADA04/2017 C BELLO 01
08
12
HS
-JE
-A
1-R
1
ANDRIGO ANTONIOLLI
CREA/SC 118142-3
-
-
JOÃO EDIO MEURER
00
01
REVISÃO
04/2017 ENTREGA
DATADESCRIÇÃO
ANDRIGO
RESPONSÁVEL
PLANTA BAIXA TÉRREO
Esc. 1:50
LEGENDA
VISTA SUPERIOR DO TUBO DE QUEDA DE ESGOTO
TUBULAÇÃO DE ÁGUA PLUVIAL
TUBULAÇÃO DE ESGOTO
VISTA SUPERIOR DA DESCIDA DA COLUNA DE ÁGUA PLUVIAL
VISTA SUPERIOR DA COLUNA DE VENTILAÇÃO
TUBULAÇÃO DE VENTILAÇÃO
CAIXA DE GORDURA
JOELHO 45º
JOELHO 90º
JOELHO 90º - COLUNA
JUNÇÃO SIMPLES
RALO SIFONADO CILÍNDRICO NORMAL SAÍDA 50 MM
CAIXA DE INSPEÇÃO DE ESGOTO PVC 40x40CE
CAIXA DE PLUVIAL PVC - ÁGUA DE REUSO 40x40
CX. AR
TÊ
CG
PVC
CF
CT
CT - COTA DE TOPO
CF - COTA DE FUNDO
DETALHE S1
Esc. 1:25
DETALHE S2
Esc. 1:25
DETALHE S4
Esc. 1:25
NOTA
AS COTAS DE TOPO DAS CAIXAS DE INSPEÇÃO E PLUVIAL TEM COMO REFERÊNCIA A COTA DO NÍVEL ACABADO
DA PARTE INTERNA DA RESIDÊNCIA, NÃO O NÍVEL DA RUA.