detailscci 1 cci 2 cci 3 cci 4 cci 5 com 0-36 v---0-36 v~ 1a a12 v r v 87654321 o n pgm status cco 5...
Post on 18-Mar-2020
7 Views
Preview:
TRANSCRIPT
myRoom
MQSE-4A1-D
Prog.Zn. 1 Zn. 2 Zn. 3 Zn. 4
lutron.com
NL N N N N DL1 DL2 DL3 DL4
MU
X
MU
X
24 V
---
CO
M
24 V--- 132 mA
100 - 120 V~
220 - 240 V~
50 / 60 Hz 4 A
220 - 240 V~
50 / 60 Hz 4 A
1 A x 4, 1 AX x 4
DIMMED LIVE - ZONE 2
DIMMED LIVE - ZONE 1
DIMMED LIVE - ZONE 3
NEUTRAL
NEUTRAL
NEUTRAL
LINE/HOT
FROM DISTRIBUTION
120 V~, 60 Hz
FROM DISTRIBUTION
PANEL
120 V~, 50/60 Hz
LINE/HOT
NEUTRAL
BEFORE AFTER
**NOTE: To control each outlet of the receptacle
independently, cut off the connecting link between
the brass screws with a wire cutter.
** SEE NOTE BELOW
CORD FROM
PLUG-IN LAMP
CORD FROM
PLUG-IN LAMP
MQSE-4A1-D
myRoom Phase Dimming Module
NTR-15-HDTR-XX
15A Half-Dimmed Receptacle
NTR-15-DDTR-XX
15A Dual-Dimmed Receptacle
CORD FROM
PLUG-IN LAMP
NOTE: BOTH FEEDS POWERING
RECEPTACLE MUST BE TIED TO
THE SAME BREAKER BY CODE.
REMOVE EXISTING PLUG FROM LAMP CORD AND
CONNECT LAMP WIRES TO TERMINAL BLOCKS
ON REPLACEMENT PLUG FROM LUTRON, MODEL
NUMBER RP-FDU-10-XX.
REMOVE EXISTING PLUG FROM LAMP CORD AND
CONNECT LAMP WIRES TO TERMINAL BLOCKS
ON REPLACEMENT PLUG FROM LUTRON, MODEL
NUMBER RP-FDU-10-XX.
REMOVE EXISTING PLUG FROM LAMP CORD AND
CONNECT LAMP WIRES TO TERMINAL BLOCKS
ON REPLACEMENT PLUG FROM LUTRON, MODEL
NUMBER RP-FDU-10-XX.
myRoom
GCU-HOSP
lutron.com
24 - 36 V---
IEC PELV/SELV/NEC Class 2
www.lutron.com/qs
R
R
1.844.LUTRON1
+ 44.(0)20.7680.4481
PWR
ERR
L1
L1
L1
L1 TX/RX
L2
L2 TX/RX
QS L2QS L1
1 2 3 4 5
COM
V+ MUX
MUX
D
1 2 3 4 5
COM
V+ MUX
MUX
D
FD/C
ol
Con/A
ctRJ45
FD/C
ol
Con/A
ctRJ45
5 43 2 1
L1L2 PCO
M
2.0 A/ L1, L2 250 mA24 - 36 V---
PWR
Input | Entrada | Entree :120 - 240 V~50 - 60 Hz0.3 - 0.8A
myRoom
TM
TM
Output | Salida | Sortie :24 V--- 1A30 PDU Max.
-
+
N L
FROM DISTRIBUTION
PANEL
120 V~, 50/60 Hz
LINE/HOT
NEUTRAL
TERMINAL 1 - COM
TERMINALS 2/3/4 - 24V--- / L1 / L2
(+)
(-)
MQSPS-DH-1-30
myRoom Power Supply
GCU-HOSP
myRoom 2-link Processor
MUX
MUX
V+
COM
MUX
MUX
V+
COM
TO DEVICES
ON QS LINK 2
TO DEVICES
ON QS LINK 1
myRoom
GCU-HOSP-1
lutron.com
24 - 36 V---
IEC PELV/SELV/NEC Class 2
www.lutron.com/qs
R
R
1.844.LUTRON1
+ 44.(0)20.7680.4481
PWR
ERR
L1
L1
L1
L1 TX/RX
QS L1
1 2 3 4 5
COM
V+ MUX
MUX
D
FD/C
ol
Con/A
ctRJ45
Input | Entrada | Entree :120 - 240 V~50 - 60 Hz0.3 - 0.8A
myRoom
TM
TM
Output | Salida | Sortie :24 V--- 1A30 PDU Max.
-
+
N L
FROM DISTRIBUTION
PANEL
120 V~, 50/60 Hz
LINE/HOT
NEUTRAL
TERMINAL 1 - COM
TERMINAL 2 - 24V---
(+)
(-)
MQSPS-DH-1-30
myRoom Power Supply
GCU-HOSP-1
myRoom 1-link Processor
MUX
MUX
V+
COM
TO DEVICES
ON QS LINK 1
Input | Entrada | Entree :120 - 240 V~50 - 60 Hz0.3 - 0.8A
myRoom
TM
TM
Output | Salida | Sortie :24 V--- 1A30 PDU Max.
-
+
N L
FROM DISTRIBUTION
PANEL
120 V~, 50/60 Hz
LINE/HOT
NEUTRAL
myRoom
GCU-HOSP-1
lutron.com
24 - 36 V---
IEC PELV/SELV/NEC Class 2
www.lutron.com/qs
R
R
1.844.LUTRON1
+ 44.(0)20.7680.4481
PWR
ERR
L1
L1
L1
L1 TX/RX
QS L1
1 2 3 4 5
COM
V+ MUX
MUX
D
FD/C
ol
Con/A
ctRJ45
QSE-IO
lutron.com
24 - 36 V--- 100 mA
SELV/PELV/NEC Class 2
www.lutron.com/qs
R
R
+ 1.610.282.3800
QS
1234
COM
V+MUX
MUX
+ 1.800.523.9466
CCO
1 NC
CCO
1 NO
1-2 C
OMCC
O 2 N
CCC
O 2 N
OCC
O 3 N
CCC
O 3 N
O3-
4 COM
CCO
4 NC
CCO
4 NO
CCO
5 NC
CCO
5 NO
5 COM
CCI 1
CCI 2
CCI 3
CCI 4
CCI 5
COM
0-36 V---
0-36 V~
1A
A
1
2
RV
R
V
87
65 4
3 2 1
O
N PGM
CCO
5CC
O 4
CCO
3CC
O 2
CCO
1
Statu
s
0 2 7 5 5 7 6 1 3 2 3 1
MUX
MUX
V+
COM
TO DEVICES
ON QS LINK 1
MUX
MUX
V+
COM
LV16-120
myRoom 16" Enclosure with
GCU-HOSP-1
myRoom 1-link Processor
QSE-IO
Contact Closure Interface
&
MQSPS-DH-1-30
myRoom Power Supply
Input | Entrada | Entree :120 - 240 V~50 - 60 Hz0.3 - 0.8A
myRoom
TM
TM
Output | Salida | Sortie :24 V--- 1A30 PDU Max.
-
+
N L
FROM DISTRIBUTION
PANEL
120 V~, 50/60 Hz
LINE/HOT
NEUTRAL
QSE-IO
lutron.com
24 - 36 V--- 100 mA
SELV/PELV/NEC Class 2
www.lutron.com/qs
R
R
+ 1.610.282.3800
QS
1234
COM
V+MUX
MUX
+ 1.800.523.9466
CCO
1 NC
CCO
1 NO
1-2 C
OMCC
O 2 N
CCC
O 2 N
OCC
O 3 N
CCC
O 3 N
O3-
4 COM
CCO
4 NC
CCO
4 NO
CCO
5 NC
CCO
5 NO
5 COM
CCI 1
CCI 2
CCI 3
CCI 4
CCI 5
COM
0-36 V---
0-36 V~
1A
A
1
2
RV
R
V
87
65 4
3 2 1
O
N PGM
CCO
5CC
O 4
CCO
3CC
O 2
CCO
1
Statu
s
0 2 7 5 5 7 6 1 3 2 3 1
MUX
MUX
V+
COM
TO DEVICES
ON QS LINK 1
MUX
MUX
V+
COM
LV16-120
myRoom 16" Enclosure with
GCU-HOSP
myRoom 2-link Processor
QSE-IO
Contact Closure Interface
&
MQSPS-DH-1-30
myRoom Power Supply
myRoom
GCU-HOSP
lutron.com
24 - 36 V---
IEC PELV/SELV/NEC Class 2
www.lutron.com/qs
R
R
1.844.LUTRON1
+ 44.(0)20.7680.4481
PWR
ERR
L1
L1
L1
L1 TX/RX
L2
L2 TX/RX
QS L2QS L1
1 2 3 4 5
COM
V+ MUX
MUX
D
1 2 3 4 5
COM
V+ MUX
MUX
D
FD/C
ol
Con/A
ctRJ45
FD/C
ol
Con/A
ctRJ455 4 3 2 1
L1L2 PCO
M
2.0 A/ L1, L2 250 mA24 - 36 V---
PWR
WIRELESS PICO
CONTROL
MOUNTING
ADAPTER
LAMP CORD
101
DOOR
CHIME
QSE-IO
lutron.com
24 - 36 V--- 100 mA
SELV/PELV/NEC Class 2
www.lutron.com/qs
R
R
+ 1.610.282.3800
QS
1234
COM
V+MUX
MUX
+ 1.800.523.9466
CCO
1 NC
CCO
1 NO
1-2 C
OMCC
O 2 N
CCC
O 2 N
OCC
O 3 N
CCC
O 3 N
O3-
4 COM
CCO
4 NC
CCO
4 NO
CCO
5 NC
CCO
5 NO
5 COM
CCI 1
CCI 2
CCI 3
CCI 4
CCI 5
COM
0-36 V---
0-36 V~
1A
A
1
2
RV
R
V
8 7 6 5 4 3 21
O
N PGM
CCO
5CC
O 4
CCO
3CC
O 2
CCO
1
Statu
s
0 2 7 5 5 7 6 1 3 2 3 1
QSE-IO
Contact Closure Interface
24V--- POWER
Door Chime
Lutron recommends
ATW model PC-200
Corridor Sign with
door chime button
and LED indicators
Door Chime Button
with LED indicators
Lutron Recommends
EEC Switch Model 19
RED LED WIRE (CCO 1 NO)
GREEN LED WIRE (CCO 2 NO)
CCO 5 NO
COMMON
CCI 1
CCI COM
1 2 3 4
PICO-WBX-ADAPT
Wallbox adapter for Pico Controls
Pico Wireless Control
(model PJ2-4B-xxx-xx shown)
Claro Faceplate Adapter
included in model CW-1-xx
Claro Faceplate
included in model CW-1-xx
Back View
Back View Back View Back View
U.S. Style Palladiom Faceplate
and Faceplate Adapter
Included with single gang U.S. Style
Palladiom keypads
1 Gang US Backbox
(not provided by Lutron)
Single Gang Palladiom Keypad
(4-Button version shown)
Model Number MWP-U-4W-xx-E
U.S. Style Palladiom Faceplate
and Faceplate Adapter
Model Number LWT-U-PP-xx
2 Gang US Backbox
(not provided by Lutron)
(2) Palladiom Keypad base units
(4-Button version shown)
Model Number MWP-B-4W-xx-E
(3) Palladiom Keypad base units
(4-Button version shown)
Model Number MWP-B-4W-xx-E
3 Gang US Backbox
(not provided by Lutron)U.S. Style Palladiom Faceplate
and Faceplate Adapter
Model Number LWT-U-PPP-xx
4 Gang US Backbox
(not provided by Lutron)
U.S. Style Palladiom Faceplate
and Faceplate Adapter
Model Number LWT-U-PPPP-xx
(3) Palladiom Keypad base units
(4-Button version shown)
Model Number MWP-B-4W-xx-E
SINGLE GANG U.S. STYLE TWO GANG U.S. STYLE THREE GANG U.S. STYLE FOUR GANG U.S. STYLE
Back View
Two horizontal screws must be used.
Back View
Note: 2-column keypad shown.
Two 1-column keypads cannot
mount to a wallbox.
92mm
(3.6in)
Back View
Note: Two 2-column keypads shown. Four 1-column
keypads cannot mount to a wallbox.
Square Style Palladiom Faceplate
and Faceplate Adapter
Included with single & 2-column
Square Style Palladiom keypads
Single Column Square Palladiom Keypad
(4-Button version shown)
Model Number MWP-S-4W-xx-E
Square or Round Wallbox*
(provided by E.C. or Lutron)
Lutron models:
EBB-1-SQ & EBB-1-RD
*Use wallbox with 4 available
mounting screw holes for
maximum flexibility.
Square or Round Wallbox*
(provided by E.C. or Lutron)
Lutron models:
EBB-1-SQ & EBB-1-RD
*Use wallbox with 4 available
mounting screw holes for
maximum flexibility.
Square Style Palladiom Faceplate
and Faceplate Adapter
Included with single & 2-column
Square Style Palladiom keypads
Two vertical screws must be used.
2-Column Square Palladiom Keypad
(4-Button/4-Button version shown)
Model Number MWP-S-44W-xx-E
SINGLE COLUMN SQUARE STYLE 2-COLUMN SQUARE STYLE 4-COLUMN SQUARE STYLE
4-Column Square Style Palladiom Faceplate
and Faceplate Adapter
Model number LWT-S-PPPP-xx
(2) 2-Column Square Palladiom Keypad base units
(4-Button/4-Button version shown for each)
Model Number MWP-B-44W-xx-E
(2) Square or Round Wallboxes*
(provided by E.C. or Lutron)
Lutron models:
EBB-1-SQ & EBB-1-RD
*Use wallboxes with 4 available
mounting screw holes for
maximum flexibility.
QSE-IO
lutron.com
24 - 36 V--- 100 mA
SELV/PELV/NEC Class 2
www.lutron.com/qs
R
R
+ 1.610.282.3800
QS
1234
COM
V+MUX
MUX
+ 1.800.523.9466
CCO
1 NC
CCO
1 NO
1-2 C
OMCC
O 2 N
CCC
O 2 N
OCC
O 3 N
CCC
O 3 N
O3-
4 COM
CCO
4 NC
CCO
4 NO
CCO
5 NC
CCO
5 NO
5 COM
CCI 1
CCI 2
CCI 3
CCI 4
CCI 5
COM
0-36 V---
0-36 V~
1A
A
1
2
RV
R
V
8 7 6 5 4 3 2 1
O
N PGM
CCO
5CC
O 4
CCO
3CC
O 2
CCO
1
Statu
s
0 2 7 5 5 7 6 1 3 2 3 1
Magnetic Door Contact
(not provided by Lutron)
CCI 1
CCI COM
QSE-IO
Contact Closure Interface
myRoom
MQSE-4S1-D
Prog.Zn. 1 Zn. 2 Zn. 3 Zn. 4
lutron.com
NL N N N N
MU
X
MU
X
24 V
---
CO
M
24 V--- 132 mA
100 - 120 V~
220 - 240 V~
50 / 60 Hz 4 A
220 - 240 V~
50 / 60 Hz 4 A
1 A
CC
O C
OM
CC
O N
.C
.
CC
O N
.O
.
CC
I C
OM
CC
I
+1.844.LUTRON1
+44.(0)20.7702.0657
1 2 3 4
IEC SELV
NEC Class 2R
R
Inc. Cont. Eq. 243C
1 AX, 1 FLA / 6 LRA
Magnetic Door Contact
(not provided by Lutron)
CCI
CCI COM
MQSE-4S1-D
myRoom Switching Module
with (1) contact closure input
Lutron Palladiom Thermostat
MWP-T-OHW-xxx-A
(Rear View)
Lutron Fan Coil Unit Controller
SMCxx-HOSP
Gray (G) (Com)
White (+) (MUX)
Black (-) (MUX)
Wire harness for thermostat
communication link (included
in wire harness kit)
Note: Refer to Fan Coil Unit Controller
specification sheet for wiring diagrams between
controller and Fan Coil Unit control board.
1 2 3 4
MUX
MUX
V+
COM
TO MYROOM
SYSTEM QS LINK
- + G
SELV/PELV/NEC Class 2:
One or two 18 AWG (1.0 mm
2
)
1: Common (Black)
2: V+ (Red)
Data Link:
One Shielded, Twisted Pair
18 AWG to 22 AWG (1.0 mm
2
to 0.5mm
2
)
3: MUX (Purple)
4: MUX (White)
Drain Shield
SELV/PELV/NEC Class 2:
One 18 AWG (1.0 mm
2
)
1: Common (Black)
2: V+ (Red)
Data Link:
One Shielded, Twisted Pair
18 AWG to 22 AWG (1.0 mm
2
to 0.5mm
2
)
3: MUX (Purple)
4: MUX (White)
Drain Shield
Two 12 AWG
(2.5 mm
2
)
LINK WIRING LESS THAN 500' (153 m) LINK WIRING 500' TO 2000 FT(153 M TO 610 M)
FROM MYROOM
SYSTEM QS LINK
MUX
MUX
COM
MUX
MUX
COM
TO ADDITIONAL
DEVICES ON QS LINK
MUX
MUX
35 V
COM
Terminal Block
4-pin EDU Connector
Standard Duplex Receptacle
Lutron Plug-in Power Supply
QSPS-P1-1-35V
Alena QS Drapery Track Drive Unit
1
Dimmed Receptacles from MQSE-4A1-D Dimming Module
2
Power Supply Connections to myRoom Processors
3
LV16-120 with MQSPS-DH-1-30, GCU-HOSP-1, & QSE-IO
4
LV16-120 with MQSPS-DH-1-30, GCU-HOSP, & QSE-IO
PICO-CORDMOUNT-CPN6969 ASSEMBLY DIAGRAM
7
CONNECTION TO ILLUMINATED DOORBELL BUTTON & DOOR CHIME
9
PICO MOUNTING WITH WALLBOX ADAPTER & FACEPLATE
8
SQUARE STYLE PALLADIOM KEYPAD ASSEMBLY DIAGRAMS
6
U.S. STYLE PALLADIOM KEYPAD ASSEMBLY DIAGRAMS
5
DOOR CONTACT TO QSE-IO
10
DOOR CONTACT TO MQSE-4S1-D
11
PALLADIOM THERMOSTAT TO FCU CONTROLLER
13
PALLADIOM KEYPAD WIRING
12
ALENA QS DRAPERY TRACK WIRING
14